Biological imaging by soft x-ray diffraction microscopy
Open accessThe DOI matches its Crossref record; 15 of the 15 references it cites were found in a registry or an index.
Abstract
We have used the method of x-ray diffraction microscopy to image the complex-valued exit wave of an intact and unstained yeast cell. The images of the freeze-dried cell, obtained by using 750-eV x-rays from different angular orientations, portray several of the cell's major internal components to 30-nm resolution. The good agreement among the independently recovered structures demonstrates the accuracy of the imaging technique. To obtain the best possible reconstructions, we have implemented procedures for handling noisy and incomplete diffraction data, and we propose a method for determining the reconstructed resolution. This work represents a previously uncharacterized application of x-ray diffraction microscopy to a specimen of this complexity and provides confidence in the feasibility of the ultimate goal of imaging biological specimens at 10-nm resolution in three dimensions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Miao, J., Charalambous, P., Kirz, J., & Sayre, D. (1999) · Nature · doi:10.1038/22498 · Cited by 1,976
Self-citationReconstruction of an object from the modulus of its Fourier transform
Fienup, J. R. (1978) · Optics Letters · doi:10.1364/ol.3.000027 · Cited by 1,836
X-ray image reconstruction from a diffraction pattern alone
Marchesini, S., He, H., Chapman, H. N., Hau-Riege, S. P., Noy, A., Howells, M. R., Weierstall, U., & Spence, J. C. H. (2003) · Physical Review B · doi:10.1103/physrevb.68.140101 · Cited by 883
Self-citationMacromolecular Architecture in Eukaryotic Cells Visualized by Cryoelectron Tomography
Medalia, O., Weber, I., Frangakis, A. S., Nicastro, D., Gerisch, G., & Baumeister, W. (2002) · Science · doi:10.1126/science.1076184 · Cited by 837
Phase retrieval by iterated projections
Elser, V. (2003) · Journal of the Optical Society of America A · doi:10.1364/josaa.20.000040 · Cited by 737
Self-citationAn assessment of the resolution limitation due to radiation-damage in X-ray diffraction microscopy
Howells, M. R., Beetz, T., Chapman, H. N., Cui, C., Holton, J. M., Jacobsen, C. J., Kirz, J., Lima, E., Marchesini, S., Miao, H., et al. (2009) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/j.elspec.2008.10.008 · Cited by 524
Self-citationTyers, M., Tokiwa, G., & Futcher, B. (1993) · The EMBO Journal · doi:10.1002/j.1460-2075.1993.tb05845.x · Cited by 475
High Resolution 3D X-Ray Diffraction Microscopy
Miao, J., Ishikawa, T., Johnson, B., Anderson, E. H., Lai, B., & Hodgson, K. O. (2002) · Physical Review Letters · doi:10.1103/physrevlett.89.088303 · Cited by 331
Three-Dimensional Imaging of Microstructure in Au Nanocrystals
Williams, G. J., Pfeifer, M. A., Vartanyants, I. A., & Robinson, I. K. (2003) · Physical Review Letters · doi:10.1103/physrevlett.90.175501 · Cited by 306
Larabell, C. A., & Le Gros, M. A. (2004) · Molecular Biology of the Cell · doi:10.1091/mbc.e03-07-0522 · Cited by 282
Cited by
High-Resolution Scanning X-ray Diffraction Microscopy
Thibault, P., Dierolf, M., Menzel, A., Bunk, O., David, C., & Pfeiffer, F. (2008) · Science · doi:10.1126/science.1158573 · Cited by 1,321
Self-citationFemtosecond diffractive imaging with a soft-X-ray free-electron laser
Chapman, H. N., Barty, A., Bogan, M. J., Boutet, S., Frank, M., Hau-Riege, S. P., Marchesini, S., Woods, B. W., Bajt, S., Benner, W. H., et al. (2006) · Nature Physics · doi:10.1038/nphys461 · Cited by 1,026
Self-citationSingle mimivirus particles intercepted and imaged with an X-ray laser
Seibert, M. M., Ekeberg, T., Maia, F. R. N. C., Svenda, M., Andreasson, J., Jönsson, O., Odić, D., Iwan, B., Rocker, A., Westphal, D., et al. (2011) · Nature · doi:10.1038/nature09748 · Cited by 904
Hard-X-Ray Lensless Imaging of Extended Objects
Rodenburg, J. M., Hurst, A. C., Cullis, A. G., Dobson, B. R., Pfeiffer, F., Bunk, O., David, C., Jefimovs, K., & Johnson, I. (2007) · Physical Review Letters · doi:10.1103/physrevlett.98.034801 · Cited by 855
Beyond crystallography: Diffractive imaging using coherent x-ray light sources
Miao, J., Ishikawa, T., Robinson, I. K., & Murnane, M. M. (2015) · Science · doi:10.1126/science.aaa1394 · Cited by 808
Probe retrieval in ptychographic coherent diffractive imaging
Thibault, P., Dierolf, M., Bunk, O., Menzel, A., & Pfeiffer, F. (2009) · Ultramicroscopy · doi:10.1016/j.ultramic.2008.12.011 · Cited by 717
Self-citationHigh-resolution ab initio three-dimensional x-ray diffraction microscopy
Chapman, H. N., Barty, A., Marchesini, S., Noy, A., Hau-Riege, S. P., Cui, C., Howells, M. R., Rosen, R., He, H., Spence, J. C. H., et al. (2006) · Journal of the Optical Society of America A · doi:10.1364/josaa.23.001179 · Cited by 592
Self-citationCoherent lensless X-ray imaging
Chapman, H. N., & Nugent, K. A. (2010) · Nature Photonics · doi:10.1038/nphoton.2010.240 · Cited by 591
Invited Article: A unified evaluation of iterative projection algorithms for phase retrieval
Marchesini, S. (2007) · Review of Scientific Instruments · doi:10.1063/1.2403783 · Cited by 573
An assessment of the resolution limitation due to radiation-damage in X-ray diffraction microscopy
Howells, M. R., Beetz, T., Chapman, H. N., Cui, C., Holton, J. M., Jacobsen, C. J., Kirz, J., Lima, E., Marchesini, S., Miao, H., et al. (2009) · Journal of Electron Spectroscopy and Related Phenomena · doi:10.1016/j.elspec.2008.10.008 · Cited by 524
Self-citationCoherent methods in the X-ray sciences
Nugent, K. A. (2010) · Advances in Physics · doi:10.1080/00018730903270926 · Cited by 476
Imaging Atomic Structure and Dynamics with Ultrafast X-ray Scattering
Gaffney, K. J., & Chapman, H. N. (2007) · Science · doi:10.1126/science.1135923 · Cited by 393
Magnetism in curved geometries
Streubel, R., Fischer, P., Kronast, F., Kravchuk, V. P., Sheka, D. D., Gaididei, Y., Schmidt, O. G., & Makarov, D. (2016) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/49/36/363001 · Cited by 371
Three-Dimensional Reconstruction of the Giant Mimivirus Particle with an X-Ray Free-Electron Laser
Ekeberg, T., Svenda, M., Abergel, C., Maia, F. R. N. C., Seltzer, V., Claverie, J.-M., Hantke, M., Jönsson, O., Nettelblad, C., van der Schot, G., et al. (2015) · Physical Review Letters · doi:10.1103/physrevlett.114.098102 · Cited by 344
Lensless Diffractive Imaging Using Tabletop Coherent High-Harmonic Soft-X-Ray Beams
Sandberg, R. L., Paul, A., Raymondson, D. A., Hädrich, S., Gaudiosi, D. M., Holtsnider, J., Tobey, R. I., Cohen, O., Murnane, M. M., Kapteyn, H. C., et al. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.098103 · Cited by 331
Influence of the overlap parameter on the convergence of the ptychographical iterative engine
Bunk, O., Dierolf, M., Kynde, S., Johnson, I., Marti, O., & Pfeiffer, F. (2008) · Ultramicroscopy · doi:10.1016/j.ultramic.2007.08.003 · Cited by 307
Three-Dimensional Visualization of a Human Chromosome Using Coherent X-Ray Diffraction
Nishino, Y., Takahashi, Y., Imamoto, N., Ishikawa, T., & Maeshima, K. (2009) · Physical Review Letters · doi:10.1103/physrevlett.102.018101 · Cited by 306
Polarized X-ray scattering reveals non-crystalline orientational ordering in organic films
Collins, B. A., Cochran, J. E., Yan, H., Gann, E., Hub, C., Fink, R., Wang, C., Schuettfort, T., McNeill, C. R., Chabinyc, M. L., et al. (2012) · Nature Materials · doi:10.1038/nmat3310 · Cited by 302
Reconstruction algorithm for single-particle diffraction imaging experiments
Loh, N.-T. D., & Elser, V. (2009) · Physical Review E · doi:10.1103/physreve.80.026705 · Cited by 292
Self-citationLombi, E., & Susini, J. (2009) · Plant and Soil · doi:10.1007/s11104-008-9876-x · Cited by 263
Femtosecond time-delay X-ray holography
Chapman, H. N., Hau-Riege, S. P., Bogan, M. J., Bajt, S., Barty, A., Boutet, S., Marchesini, S., Frank, M., Woods, B. W., Benner, W. H., et al. (2007) · Nature · doi:10.1038/nature06049 · Cited by 262
Self-citationMiao, J., Ishikawa, T., Shen, Q., & Earnest, T. (2008) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.59.032607.093642 · Cited by 241
High-resolution three-dimensional partially coherent diffraction imaging
Clark, J. N., Huang, X., Harder, R., & Robinson, I. K. (2012) · Nature Communications · doi:10.1038/ncomms1994 · Cited by 232
Phase retrieval by coherent modulation imaging
Zhang, F., Chen, B., Morrison, G. R., Vila-Comamala, J., Guizar-Sicairos, M., & Robinson, I. K. (2016) · Nature Communications · doi:10.1038/ncomms13367 · Cited by 216
Imaging live cell in micro-liquid enclosure by X-ray laser diffraction
Kimura, T., Joti, Y., Shibuya, A., Song, C., Kim, S., Tono, K., Yabashi, M., Tamakoshi, M., Moriya, T., Oshima, T., et al. (2014) · Nature Communications · doi:10.1038/ncomms4052 · Cited by 208
Quantitative Imaging of Single, Unstained Viruses with Coherent X Rays
Song, C., Jiang, H., Mancuso, A., Amirbekian, B., Peng, L., Sun, R., Shah, S. S., Zhou, Z. H., Ishikawa, T., & Miao, J. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.158101 · Cited by 199
Quantitative phase tomography of Arabidopsis seeds reveals intercellular void network
Cloetens, P., Mache, R., Schlenker, M., & Lerbs-Mache, S. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0603490103 · Cited by 188
Simultaneous cryo X-ray ptychographic and fluorescence microscopy of green algae
Deng, J., Vine, D. J., Chen, S., Nashed, Y. S. G., Jin, Q., Phillips, N. W., Peterka, T., Ross, R., Vogt, S., & Jacobsen, C. J. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1413003112 · Cited by 180
“ratio (14)] is a commonly used method to assess resolution by finding the finest periodicity at which phases are consistent in iterative phase retrieval (Fig.”
MethodResultSelf-citationCoherent X-Ray Diffraction Imaging
Miao, J., Sandberg, R. L., & Song, C. (2012) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2011.2157306 · Cited by 172
“viruses, and biomaterials [21], [24], [30], [33]–[37], [40]–[42], and a highest resolution of 10–15 nm has been achieved on biological samples [41].”
BackgroundCoherent X-Ray Diffraction Imaging with Nanofocused Illumination
Schroer, C. G., Boye, P., Feldkamp, J. M., Patommel, J., Schropp, A., Schwab, A., Stephan, S., Burghammer, M., Schöder, S., & Riekel, C. (2008) · Physical Review Letters · doi:10.1103/physrevlett.101.090801 · Cited by 170
Imaging Catalysts at Work: A Hierarchical Approach from the Macro‐ to the Meso‐ and Nano‐scale
Grunwaldt, J., Wagner, J. B., & Dunin‐Borkowski, R. E. (2013) · ChemCatChem · doi:10.1002/cctc.201200356 · Cited by 164
Nuclear microscopy: A tool for imaging elemental distribution and percutaneous absorption in vivo
Veríssimo, A., Alves, L. C., Filipe, P., Silva, J. N., Silva, R., Dolores YNSA, M., Gontier, E., Moretto, P., Pallon, J., & Pinheiro, T. (2007) · Microscopy Research and Technique · doi:10.1002/jemt.20402 · Cited by 42
“This approach makes it possible to image hydrated or frozen-hydrated biological specimens and cells at 10-nm resolution in two or three dimensions (Johansson et al., 2004; Shapiro et al., 2005 ).”
Metadata
- Authors
- Shapiro, D., Thibault, P., Beetz, T., Elser, V., Howells, M., Jacobsen, C., Kirz, J., Lima, E., Miao, H., Neiman, A. M., & Sayre, D.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2005-10-11
- Volume
- 102
- Issue
- 43
- Pages
- 15343-15346
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2114520361
- Cited by
- 554
- References
- 15
- FWCI
- 30.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.