The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Three-dimensional, single-molecule fluorescence imaging beyond the diffraction limit by using a double-helix point spread function
Open accessAbstract
We demonstrate single-molecule fluorescence imaging beyond the optical diffraction limit in 3 dimensions with a wide-field microscope that exhibits a double-helix point spread function (DH-PSF). The DH-PSF design features high and uniform Fisher information and has 2 dominant lobes in the image plane whose angular orientation rotates with the axial ( z ) position of the emitter. Single fluorescent molecules in a thick polymer sample are localized in single 500-ms acquisitions with 10- to 20-nm precision over a large depth of field (2 μm) by finding the center of the 2 DH-PSF lobes. By using a photoactivatable fluorophore, repeated imaging of sparse subsets with a DH-PSF microscope provides superresolution imaging of high concentrations of molecules in all 3 dimensions. The combination of optical PSF design and digital postprocessing with photoactivatable fluorophores opens up avenues for improving 3D imaging resolution beyond the Rayleigh diffraction limit.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Ultra-High Resolution Imaging by Fluorescence Photoactivation Localization Microscopy
Hess, S. T., Girirajan, T. P. K., & Mason, M. D. (2006) · Biophysical Journal · doi:10.1529/biophysj.106.091116 · Cited by 3,605
Three-Dimensional Super-Resolution Imaging by Stochastic Optical Reconstruction Microscopy
Huang, B., Wang, W., Bates, M., & Zhuang, X. (2008) · Science · doi:10.1126/science.1153529 · Cited by 2,796
Beiträge zur Theorie des Mikroskops und der mikroskopischen Wahrnehmung
Abbe, E. (1873) · Archiv für Mikroskopische Anatomie · doi:10.1007/bf02956173 · Cited by 2,724
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
Myosin V Walks Hand-Over-Hand: Single Fluorophore Imaging with 1.5-nm Localization
Yildiz, A., Forkey, J. N., McKinney, S. A., Ha, T., Goldman, Y. E., & Selvin, P. R. (2003) · Science · doi:10.1126/science.1084398 · Cited by 1,837
Wide-field subdiffraction imaging by accumulated binding of diffusing probes
Sharonov, A., & Hochstrasser, R. M. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0609643104 · Cited by 1,151
Tracking kinesin-driven movements with nanometre-scale precision
Gelles, J., Schnapp, B. J., & Sheetz, M. P. (1988) · Nature · doi:10.1038/331450a0 · Cited by 819
Three-dimensional sub–100 nm resolution fluorescence microscopy of thick samples
Juette, M. F., Gould, T. J., Lessard, M. D., Mlodzianoski, M. J., Nagpure, B. S., Bennett, B. T., Hess, S. T., & Bewersdorf, J. (2008) · Nature Methods · doi:10.1038/nmeth.1211 · Cited by 812
Localization Accuracy in Single-Molecule Microscopy
Ober, R. J., Ram, S., & Ward, E. S. (2004) · Biophysical Journal · doi:10.1016/s0006-3495(04)74193-4 · Cited by 587
Shroff, H., Galbraith, C. G., Galbraith, J. A., White, H., Gillette, J., Olenych, S., Davidson, M. W., & Betzig, E. (2007) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0710517105 · Cited by 498
Kao, H. P., & Verkman, A. S. (1994) · Biophysical Journal · doi:10.1016/s0006-3495(94)80601-0 · Cited by 420
The physical principles of the quantum theory
Temple, G. (1932) · Proceedings of the Royal Society of London. Series A, Containing Papers of a Mathematical and Physical Character · doi:10.1098/rspa.1932.0197 · Cited by 380
Position measurement with a resolution and noise-limited instrument
Bobroff, N. (1986) · Review of Scientific Instruments · doi:10.1063/1.1138619 · Cited by 375
Superresolution by localization of quantum dots using blinking statistics
Lidke, K. A., Rieger, B., Jovin, T. M., & Heintzmann, R. (2005) · Optics Express · doi:10.1364/opex.13.007052 · Cited by 361
Ambrose, W. P., Basché, T., & Moerner, W. E. (1991) · The Journal of Chemical Physics · doi:10.1063/1.461392 · Cited by 350
Self-citationRam, S., Prabhat, P., Chao, J., Sally Ward, E., & Ober, R. J. (2008) · Biophysical Journal · doi:10.1529/biophysj.108.140392 · Cited by 259
Nanometric three-dimensional tracking of individual quantum dots in cells
Holtzer, L., Meckel, T., & Schmidt, T. (2007) · Applied Physics Letters · doi:10.1063/1.2437066 · Cited by 253
Pavani, S. R. P., & Piestun, R. (2008) · Optics Express · doi:10.1364/oe.16.022048 · Cited by 220
Self-citationA Photoactivatable Push−Pull Fluorophore for Single-Molecule Imaging in Live Cells
Lord, S. J., Conley, N. R., Lee, H.-L. D., Samuel, R., Liu, N., Twieg, R. J., & Moerner, W. E. (2008) · Journal of the American Chemical Society · doi:10.1021/ja802883k · Cited by 216
Self-citation3-Dimensional super-resolution by spectrally selective imaging
van Oijen, A. M., Köhler, J., Schmidt, J., Müller, M., & Brakenhoff, G. J. (1998) · Chemical Physics Letters · doi:10.1016/s0009-2614(98)00673-3 · Cited by 200
Multilayer three-dimensional super resolution imaging of thick biological samples
Vaziri, A., Tang, J., Shroff, H., & Shank, C. V. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0810636105 · Cited by 180
Propagation-invariant wave fields with finite energy
Piestun, R., Schechner, Y. Y., & Shamir, J. (2000) · Journal of the Optical Society of America A · doi:10.1364/josaa.17.000294 · Cited by 161
Self-citationVisualization of the movement of single histidine kinase molecules in live Caulobacter cells
Deich, J., Judd, E. M., McAdams, H. H., & Moerner, W. E. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0404200101 · Cited by 132
Self-citationNovel Fluorophores for Single-Molecule Imaging
Willets, K. A., Ostroverkhova, O., He, M., Twieg, R. J., & Moerner, W. E. (2003) · Journal of the American Chemical Society · doi:10.1021/ja029100q · Cited by 106
Self-citation
Cited by
ATPase-Modulated Stress Granules Contain a Diverse Proteome and Substructure
Jain, S., Wheeler, J. R., Walters, R. W., Agrawal, A., Barsic, A., & Parker, R. (2016) · Cell · doi:10.1016/j.cell.2015.12.038 · Cited by 1,590
A guide to super-resolution fluorescence microscopy
Schermelleh, L., Heintzmann, R., & Leonhardt, H. (2010) · Journal of Cell Biology · doi:10.1083/jcb.201002018 · Cited by 1,255
Super-resolution microscopy demystified
Schermelleh, L., Ferrand, A., Huser, T., Eggeling, C., Sauer, M., Biehlmaier, O., & Drummen, G. P. C. (2019) · Nature Cell Biology · doi:10.1038/s41556-018-0251-8 · Cited by 1,211
Breaking the Diffraction Barrier: Super-Resolution Imaging of Cells
Huang, B., Babcock, H., & Zhuang, X. (2010) · Cell · doi:10.1016/j.cell.2010.12.002 · Cited by 1,156
Direct stochastic optical reconstruction microscopy with standard fluorescent probes
van de Linde, S., Löschberger, A., Klein, T., Heidbreder, M., Wolter, S., Heilemann, M., & Sauer, M. (2011) · Nature Protocols · doi:10.1038/nprot.2011.336 · Cited by 1,071
Metadata
- Authors
- Pavani, S. R. P., Thompson, M. A., Biteen, J. S., Lord, S. J., Liu, N., Twieg, R. J., Piestun, R., & Moerner, W. E.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2009-03-03
- Volume
- 106
- Issue
- 9
- Pages
- 2995-2999
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W4231350070
- Cited by
- 1,040
- References
- 26
- FWCI
- 30.56
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.