High-resolution dose–response screening using droplet-based microfluidics
Open accessThe DOI matches its Crossref record; 49 of the 49 references it cites were found in a registry or an index.
Abstract
A critical early step in drug discovery is the screening of a chemical library. Typically, promising compounds are identified in a primary screen and then more fully characterized in a dose–response analysis with 7–10 data points per compound. Here, we describe a robust microfluidic approach that increases the number of data points to approximately 10,000 per compound. The system exploits Taylor–Aris dispersion to create concentration gradients, which are then segmented into picoliter microreactors by droplet-based microfluidics. The large number of data points results in IC 50 values that are highly precise (± 2.40% at 95% confidence) and highly reproducible (CV = 2.45%,n = 16). In addition, the high resolution of the data reveals complex dose–response relationships unambiguously. We used this system to screen a chemical library of 704 compounds against protein tyrosine phosphatase 1B, a diabetes, obesity, and cancer target. We identified a number of novel inhibitors, the most potent being sodium cefsulodine, which has an IC 50 of 27 ± 0.83 μM.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Zhang, J.-H., Chung, T. D. Y., & Oldenburg, K. R. (1999) · SLAS Discovery · doi:10.1177/108705719900400206 · Cited by 6,847
Rapid Prototyping of Microfluidic Systems in Poly(dimethylsiloxane)
Duffy, D. C., McDonald, J. C., Schueller, O. J. A., & Whitesides, G. M. (1998) · Analytical Chemistry · doi:10.1021/ac980656z · Cited by 5,288
Dispersion of soluble matter in solvent flowing slowly through a tube
Taylor, G. I. (1953) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1953.0139 · Cited by 5,109
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
On the dispersion of a solute in a fluid flowing through a tube
Aris, R. (1956) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1956.0065 · Cited by 2,835
Formation of dispersions using “flow focusing” in microchannels
Anna, S. L., Bontoux, N., & Stone, H. A. (2003) · Applied Physics Letters · doi:10.1063/1.1537519 · Cited by 2,302
The possible effects of the aggregation of the molecules of haemoglobin on its dissociation curves
Hill, A. V., Hill, A. L., & Hill, A. V. (1910) · The Journal of Physiology · Cited by 2,181
Droplet microfluidic technology for single-cell high-throughput screening
Brouzes, E., Medkova, M., Savenelli, N., Marran, D., Twardowski, M., Hutchison, J. B., Rothberg, J. M., Link, D. R., Perrimon, N., & Samuels, M. L. (2009) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0903542106 · Cited by 1,069
Self-citationMicrodroplets in Microfluidics: An Evolving Platform for Discoveries in Chemistry and Biology
Theberge, A. B., Courtois, F., Schaerli, Y., Fischlechner, M., Abell, C., Hollfelder, F., & Huck, W. T. S. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200906653 · Cited by 1,059
Inglese, J., Auld, D. S., Jadhav, A., Johnson, R. L., Simeonov, A., Yasgar, A., Zheng, W., & Austin, C. P. (2006) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0604348103 · Cited by 792
Taylor, G. I. (1954) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1954.0216 · Cited by 779
Statistical practice in high-throughput screening data analysis
Malo, N., Hanley, J. A., Cerquozzi, S., Pelletier, J., & Nadon, R. (2006) · Nature Biotechnology · doi:10.1038/nbt1186 · Cited by 721 · cited 1×
“This results in high numbers of false positives and false negatives (2), as well as the inability to identify subtle, complex pharmacology, such as partial agonism or antagonism.”
BackgroundClausell-Tormos, J., Lieber, D., Baret, J.-C., El-Harrak, A., Miller, O. J., Frenz, L., Blouwolff, J., Humphry, K. J., Köster, S., Duan, H., et al. (2008) · Chemistry & Biology · doi:10.1016/j.chembiol.2008.04.004 · Cited by 720
Self-citationNovel trends in high-throughput screening
Mayr, L. M., & Bojanic, D. (2009) · Current Opinion in Pharmacology · doi:10.1016/j.coph.2009.08.004 · Cited by 694
Millisecond Kinetics on a Microfluidic Chip Using Nanoliters of Reagents
Song, H., & Ismagilov, R. F. (2003) · Journal of the American Chemical Society · doi:10.1021/ja0354566 · Cited by 693 · cited 2×
“Several of these techniques generate droplets containing different concentrations of a compound by varying the relative flow rates of two or more aqueous streams (13, 18).”
BackgroundBiocompatible surfactants for water-in-fluorocarbon emulsions
Holtze, C., Rowat, A. C., Agresti, J. J., Hutchison, J. B., Angilè, F. E., Schmitz, C. H. J., Köster, S., Duan, H., Humphry, K. J., Scanga, R. A., et al. (2008) · Lab on a Chip · doi:10.1039/b806706f · Cited by 670
Protein tyrosine phosphatase 1B inhibitors for diabetes
Johnson, T. O., Ermolieff, J., & Jirousek, M. R. (2002) · Nature Reviews Drug Discovery · doi:10.1038/nrd895 · Cited by 653
PTP1B as a drug target: recent developments in PTP1B inhibitor discovery
Zhang, S., & Zhang, Z.-Y. (2007) · Drug Discovery Today · doi:10.1016/j.drudis.2007.03.011 · Cited by 558
A microfluidic 3D hepatocyte chip for drug toxicity testing
Toh, Y.-C., Lim, T. C., Tai, D., Xiao, G., van Noort, D., & Yu, H. (2009) · Lab on a Chip · doi:10.1039/b900912d · Cited by 419
Combs, A. P. (2010) · Journal of Medicinal Chemistry · doi:10.1021/jm901090b · Cited by 317
Interpreting steep dose-response curves in early inhibitor discovery.
Shoichet, B. K. (2006) · Journal of Medicinal Chemistry · doi:10.1021/jm061103g · Cited by 304 · cited 1×
“Being able to clearly observe this kind of behavior, including the pathologically steep Hill slope (28), will be an aid to maximizing the quality of lead compounds coming out of a screen.”
BackgroundPTP1B: a double agent in metabolism and oncogenesis
Yip, S.-C., Saha, S., & Chernoff, J. (2010) · Trends in Biochemical Sciences · doi:10.1016/j.tibs.2010.03.004 · Cited by 266
Calabrese, E. J. (2008) · British Journal of Clinical Pharmacology · doi:10.1111/j.1365-2125.2008.03243.x · Cited by 262
Permeability of Single Nuclear Pores
Keminer, O., & Peters, R. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)76883-9 · Cited by 249
A microdroplet dilutor for high-throughput screening
Niu, X., Gielen, F., Edel, J. B., & deMello, A. J. (2011) · Nature Chemistry · doi:10.1038/nchem.1046 · Cited by 199
Shen, K., Keng, Y.-F., Wu, L., Guo, X.-L., Lawrence, D. S., & Zhang, Z.-Y. (2001) · Journal of Biological Chemistry · doi:10.1074/jbc.m106568200 · Cited by 183
Reliable microfluidic on-chip incubation of droplets in delay-lines
Frenz, L., Blank, K., Brouzes, E., & Griffiths, A. D. (2009) · Lab Chip · doi:10.1039/b816049j · Cited by 170
Self-citationJoensson, H. N., Samuels, M. L., Brouzes, E. R., Medkova, M., Uhlén, M., Link, D. R., & Svahn, H. A. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200804326 · Cited by 154
Self-citationA Robotic Platform for Quantitative High-Throughput Screening
Michael, S., Auld, D., Klumpp, C., Jadhav, A., Zheng, W., Thorne, N., Austin, C. P., Inglese, J., & Simeonov, A. (2008) · ASSAY and Drug Development Technologies · doi:10.1089/adt.2008.150 · Cited by 153
Joensson, H. N., Samuels, M. L., Brouzes, E. R., Medkova, M., Uhlén, M., Link, D. R., & Svahn, H. A. (2009) · Angewandte Chemie · doi:10.1002/ange.200804326 · Cited by 131
Self-citationQuantitative Cell-Based Reporter Gene Assays Using Droplet-Based Microfluidics
Baret, J., Beck, Y., Billas, I. M. L., Moras, D., & Griffiths, A. D. (2010) · Chemistry & Biology · doi:10.1016/j.chembiol.2010.04.010 · Cited by 121
Self-citationZhang, Y.-L., Keng, Y., Zhao, Y. C., Wu, L., & Zhang, Z. (1998) · Journal of Biological Chemistry · doi:10.1074/jbc.273.20.12281 · Cited by 113
Sharma, U., Gleason, N. J., & Carbeck, J. D. (2005) · Analytical Chemistry · doi:10.1021/ac048846z · Cited by 110
Clausell-Tormos, J., Griffiths, A. D., & Merten, C. A. (2010) · Lab on a Chip · doi:10.1039/b921754a · Cited by 105
Self-citationCompartmentalization of Chemically Separated Components into Droplets
Edgar, J. S., Milne, G., Zhao, Y., Pabbati, C. P., Lim, D. S. W., & Chiu, D. T. (2009) · Angewandte Chemie International Edition · doi:10.1002/anie.200805396 · Cited by 99
Cell-Free Protein Expression and Functional Assay in Nanowell Chip Format
Angenendt, P., Nyársik, L., Szaflarski, W., Glökler, J., Nierhaus, K. H., Lehrach, H., Cahill, D. J., & Lueking, A. (2004) · Analytical Chemistry · doi:10.1021/ac035114i · Cited by 97
Automated Microfluidic Screening Assay Platform Based on DropLab
Du, W., Sun, M. Z., Gu, S., Zhu, Y., & Fang, Q. (2010) · Analytical Chemistry · doi:10.1021/ac1020479 · Cited by 88
1,2,3,4-Tetrahydroisoquinolinyl sulfamic acids as phosphatase PTP1B inhibitors
Klopfenstein, S. R., Evdokimov, A. G., Colson, A., Fairweather, N. T., Neuman, J. J., Maier, M. B., Gray, J. L., Gerwe, G. S., Stake, G. E., Howard, B. W., et al. (2006) · Bioorganic & Medicinal Chemistry Letters · doi:10.1016/j.bmcl.2005.12.051 · Cited by 86
What's wrong with drug screening today
Nolan, G. P. (2007) · Nature Chemical Biology · doi:10.1038/nchembio0407-187 · Cited by 81
Simultaneous measurement of reactions in microdroplets filled by concentration gradients
Damean, N., Olguin, L. F., Hollfelder, F., Abell, C., & Huck, W. T. S. (2009) · Lab on a Chip · doi:10.1039/b821021g · Cited by 69
Screening for content—the evolution of high throughput
Dove, A. (2003) · Nature Biotechnology · doi:10.1038/nbt0803-859 · Cited by 66
Theberge, A. B., Whyte, G., & Huck, W. T. S. (2010) · Analytical Chemistry · doi:10.1021/ac1005316 · Cited by 50
A microfluidic gradient maker for toxicity testing of bupivacaine and lidocaine
Tirella, A., Marano, M., Vozzi, F., & Ahluwalia, A. D. (2008) · Toxicology in Vitro · doi:10.1016/j.tiv.2008.09.016 · Cited by 45
Simultaneous generation of multiple aqueous droplets in a microfluidic device
Lorenz, R. M., Fiorini, G. S., Jeffries, G. D. M., Lim, D. S. W., He, M., & Chiu, D. T. (2008) · Analytica Chimica Acta · doi:10.1016/j.aca.2008.10.009 · Cited by 41
Hussain, M., Ahmed, V. F., Hill, B., Ahmed, Z., & Taylor, S. D. (2008) · Bioorganic & Medicinal Chemistry · doi:10.1016/j.bmc.2008.05.062 · Cited by 35
Mahto, S. K., Yoon, T. H., Shin, H., & Rhee, S. W. (2008) · Biomedical Microdevices · doi:10.1007/s10544-008-9246-8 · Cited by 25
2-layer based microfluidic concentration generator by hybrid serial and volumetric dilutions
Lee, K., Kim, C., Kim, Y., Jung, K., Ahn, B., Kang, J. Y., & Oh, K. W. (2010) · Biomedical Microdevices · doi:10.1007/s10544-009-9385-6 · Cited by 24
Practical Robust Fit of Enzyme Inhibition Data
Kuzmič, P., Hill, C. M., & Janc, J. W. (2004) · Methods in enzymology on CD-ROM/Methods in enzymology · doi:10.1016/s0076-6879(04)83015-5 · Cited by 13
Advances in functional assays for high-throughput screening of ion channels targets
Trivedi, S., Liu, J., Liu, R., & Bostwick, R. J. (2010) · Expert Opinion on Drug Discovery · doi:10.1517/17460441.2010.513377 · Cited by 10
Cited by
Emerging Droplet Microfluidics
Shang, L., Cheng, Y., & Zhao, Y. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00848 · Cited by 1,584
Single-cell analysis and sorting using droplet-based microfluidics
Mazutis, L., Gilbert, J., Ung, W. L., Weitz, D. A., Griffiths, A. D., & Heyman, J. A. (2013) · Nature Protocols · doi:10.1038/nprot.2013.046 · Cited by 1,355
Self-citationDroplet Microfluidics—A Tool for Single‐Cell Analysis
Joensson, H. N., & Andersson Svahn, H. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201200460 · Cited by 557
Droplet microfluidics for microbiology: techniques, applications and challenges
Kaminski, T. S., Scheler, O., & Garstecki, P. (2016) · Lab on a Chip · doi:10.1039/c6lc00367b · Cited by 424
Effect-directed analysis supporting monitoring of aquatic environments — An in-depth overview
Brack, W., Ait-Aissa, S., Burgess, R. M., Busch, W., Creusot, N., Di Paolo, C., Escher, B. I., Mark Hewitt, L., Hilscherova, K., Hollender, J., et al. (2016) · Science of The Total Environment · doi:10.1016/j.scitotenv.2015.11.102 · Cited by 413
Metadata
- Authors
- Miller, O. J., Harrak, A. E., Mangeat, T., Baret, J.-C., Frenz, L., Debs, B. E., Mayot, E., Samuels, M. L., Rooney, E. K., Dieu, P., Galvan, M., Link, D. R., & Griffiths, A. D.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2011-12-27
- Volume
- 109
- Issue
- 2
- Pages
- 378-383
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2041677432
- Cited by
- 286
- References
- 49
- FWCI
- 12.76
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.