Three-dimensional microfluidic model for tumor cell intravasation and endothelial barrier function
Open accessThe DOI matches its Crossref record; 46 of the 46 references it cites were found in a registry or an index.
Abstract
Entry of tumor cells into the blood stream is a critical step in cancer metastasis. Although significant progress has been made in visualizing tumor cell motility in vivo, the underlying mechanism of cancer cell intravasation remains largely unknown. We developed a microfluidic-based assay to recreate the tumor-vascular interface in three-dimensions, allowing for high resolution, real-time imaging, and precise quantification of endothelial barrier function. Studies are aimed at testing the hypothesis that carcinoma cell intravasation is regulated by biochemical factors from the interacting cells and cellular interactions with macrophages. We developed a method to measure spatially resolved endothelial permeability and show that signaling with macrophages via secretion of tumor necrosis factor alpha results in endothelial barrier impairment. Under these conditions intravasation rates were increased as validated with live imaging. To further investigate tumor-endothelial (TC-EC) signaling, we used highly invasive fibrosarcoma cells and quantified tumor cell migration dynamics and TC-EC interactions under control and perturbed (with tumor necrosis factor alpha) barrier conditions. We found that endothelial barrier impairment was associated with a higher number and faster dynamics of TC-EC interactions, in agreement with our carcinoma intravasation results. Taken together our results provide evidence that the endothelium poses a barrier to tumor cell intravasation that can be regulated by factors present in the tumor microenvironment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“In another recent study, a macrophage cell line (RAW 264.7) seeded in a 3D collagen gel in a microfluidic device was shown to assist and increase the intravasation of breast cancer cells through an endothelial monolayer[18], as has been observed in vivo[63].”
From Microfluidics: A New Tool for Modeling Cancer–Immune Interactions (2016) · cites this paper as [18]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“These systems enable continuous delivery of oxygen, nutrients, and therapeutic agents while introducing shear stress and directional mass transport, thereby allowing the investigation of flow-regulated processes within a tumor-relevant architecture [224,225,226,227,228].”
From Modeling Tumor Microenvironment Complexity In Vitro: Spheroids as Physiologically Relevant Tumor Models and Strategies for Their Analysis (2025) · cites this paper as [226]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“For example, by using a sandwiched design, Altemus et al. observed the whole process of breast tumor metastasis to the brain and found that the integrity of BBB could be compromised by invading cancer cells.”
From 3D Biomimetic Models to Reconstitute Tumor Microenvironment In Vitro: Spheroids, Organoids, and Tumor‐on‐a‐Chip (2023) · cites this paper as [156]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“To the best of our knowledge, only a limited number of recent studies have employed microfluidics to investigate immune-cancer cell interactions[18, 48–52], possibly because microfluidic models are not yet widely available to cancer researchers.”
From Microfluidics: A New Tool for Modeling Cancer–Immune Interactions (2016) · cites this paper as [18]
The cited source says what the claim attributes to it.
In the citing paper
“Microfluidic assays have been designed to replicate certain aspects of several of these steps, such as EMT[13, 14], cancer cell invasion and adhesion[15–17], and intra-[18, 19] and extravasation[17, 20– 22] (see Text Box 3).”
From Microfluidics: A New Tool for Modeling Cancer–Immune Interactions (2016) · cites this paper as [18]
Experimental — accuracy not yet measured
5 more claims about this paper
Create a free account to see every claim other papers make about this one.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Cancer Metastasis: Building a Framework
Gupta, G. P., & Massagué, J. (2006) · Cell · doi:10.1016/j.cell.2006.11.001 · Cited by 4,247
Microenvironmental regulation of metastasis
Joyce, J. A., & Pollard, J. W. (2009) · Nature Reviews Cancer · doi:10.1038/nrc2618 · Cited by 3,684 · cited 1×
“Cell-cell communication and chemotaxis (5) are key to this process and can occur via paracrine signals and/or direct contact between different cell types during tumor cell invasion (6) and metastatic colonization (7).”
BackgroundMacrophages: Obligate Partners for Tumor Cell Migration, Invasion, and Metastasis
Condeelis, J., & Pollard, J. W. (2006) · Cell · doi:10.1016/j.cell.2006.01.007 · Cited by 2,695
Self-citationMetastasis: from dissemination to organ-specific colonization
Nguyen, D. X., Bos, P. D., & Massagué, J. (2009) · Nature Reviews Cancer · doi:10.1038/nrc2622 · Cited by 2,649
Tumor metastasis: mechanistic insights and clinical challenges
Steeg, P. S. (2006) · Nature Medicine · doi:10.1038/nm1469 · Cited by 2,134 · cited 1×
“Cancer cell intravasation is a rate-limiting step in metastasis that regulates the number of circulating tumor cells and thus presents high risk for the formation of secondary tumors (1, 2).”
BackgroundCancer Invasion and the Microenvironment: Plasticity and Reciprocity
Friedl, P., & Alexander, S. (2011) · Cell · doi:10.1016/j.cell.2011.11.016 · Cited by 1,940 · cited 1×
“During the metastatic process tumor cells migrate out of the primary tumor (3), navigate into a complex tumor microenvironment, and enter into blood vessels (4).”
BackgroundOpenings Between Defective Endothelial Cells Explain Tumor Vessel Leakiness
Hashizume, H., Baluk, P., Morikawa, S., McLean, J. W., Thurston, G., Roberge, S., Jain, R. K., & McDonald, D. M. (2000) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)65006-7 · Cited by 1,689 · cited 2×
“Because tumor blood vessels are structurally (18) and functionally (19) abnormal, we hypothesized that endothelial barrier function impairment contributes to tumor cell intravasation.”
BackgroundDirect Visualization of Macrophage-Assisted Tumor Cell Intravasation in Mammary Tumors
Wyckoff, J. B., Wang, Y., Lin, E. Y., Li, J.-F., Goswami, S., Stanley, E. R., Segall, J. E., Pollard, J. W., & Condeelis, J. (2007) · Cancer Research · doi:10.1158/0008-5472.can-06-1823 · Cited by 1,053 · cited 4×
“Although in vivo imaging studies in animals have demonstrated the highly dynamic interaction between tumor and endothelial cells (9, 10, 12, 20), quantitation of, or control over, vessel permeability and tumor microenvironmental factors is challenging.”
BackgroundResultInfluentialSelf-citationTumor Vascular Permeability, Accumulation, and Penetration of Macromolecular Drug Carriers
Dreher, M. R., Liu, W., Michelich, C. R., Dewhirst, M. W., Yuan, F., & Chilkoti, A. (2006) · JNCI: Journal of the National Cancer Institute · doi:10.1093/jnci/djj070 · Cited by 920 · cited 1×
“2C, PD ∼ 10−6 cm∕s) as those measured in murine tumors with 70 kDa dextran (40).”
BackgroundRoussos, E. T., Condeelis, J. S., & Patsialou, A. (2011) · Nature Reviews Cancer · doi:10.1038/nrc3078 · Cited by 896 · cited 1×
“Cell-cell communication and chemotaxis (5) are key to this process and can occur via paracrine signals and/or direct contact between different cell types during tumor cell invasion (6) and metastatic colonization (7).”
BackgroundSelf-citation
Cited by
Items 101–200 of 863
Microfluidic Tumor–Vascular Model to Study Breast Cancer Cell Invasion and Intravasation
Nagaraju, S., Truong, D., Mouneimne, G., & Nikkhah, M. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701257 · Cited by 147
Review: in vitro microvessel models
Bogorad, M. I., DeStefano, J., Karlsson, J., Wong, A. D., Gerecht, S., & Searson, P. C. (2015) · Lab on a Chip · doi:10.1039/c5lc00832h · Cited by 145
Flow-induced stress on adherent cells in microfluidic devices
Shemesh, J., Jalilian, I., Shi, A., Heng Yeoh, G., Knothe Tate, M. L., & Ebrahimi Warkiani, M. (2015) · Lab on a Chip · doi:10.1039/c5lc00633c · Cited by 144
Young, E. W. K. (2013) · Integrative Biology · doi:10.1039/c3ib40076j · Cited by 143
Buchanan, C. F., Voigt, E. E., Szot, C. S., Freeman, J. W., Vlachos, P. P., & Rylander, M. N. (2014) · Tissue Engineering Part C: Methods · doi:10.1089/ten.tec.2012.0731 · Cited by 143
“State-of-the-art microfluidic devices for tissue engineering and cancer research have been primarily based on microchannels formed by soft lithography in PDMS and sealed with glass coverslips for image acquisition.(17,35,36,65,78,83,84) While these systems provide dynamic 3D cell culture environments with complex plan…”
Anguiano, M., Castilla, C., Maška, M., Ederra, C., Peláez, R., Morales, X., Muñoz-Arrieta, G., Mujika, M., Kozubek, M., Muñoz-Barrutia, A., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0171417 · Cited by 143
Complex Tissue and Disease Modeling using hiPSCs
Passier, R., Orlova, V., & Mummery, C. (2016) · Cell Stem Cell · doi:10.1016/j.stem.2016.02.011 · Cited by 142
Bone-on-a-chip: Microfluidic technologies and microphysiologic models of bone tissue
Mansoorifar, A., Gordon, R., Bergan, R. C., & Bertassoni, L. E. (2021) · Advanced Functional Materials · doi:10.1002/adfm.202006796 · Cited by 142
Three-dimensional cancer models mimic cell-matrix interactions in the tumour microenvironment
Herrmann, D., Conway, J. R. W., Vennin, C., Magenau, A., Hughes, W. E., Morton, J. P., & Timpson, P. (2014) · Carcinogenesis · doi:10.1093/carcin/bgu108 · Cited by 144
Vascular permeability changes involved in tumor metastasis
García-Román, J., & Zentella‐Dehesa, A. (2013) · Cancer Letters · doi:10.1016/j.canlet.2013.03.005 · Cited by 151
Therapy response testing of breast cancer in a 3D high-throughput perfused microfluidic platform
Lanz, H. L., Saleh, A., Kramer, B., Cairns, J., Ng, C. P., Yu, J., Trietsch, S. J., Hankemeier, T., Joore, J., Vulto, P., et al. (2017) · BMC Cancer · doi:10.1186/s12885-017-3709-3 · Cited by 135
Breast Cancer Cell Invasion into a Three Dimensional Tumor-Stroma Microenvironment
Truong, D., Puleo, J., Llave, A., Mouneimne, G., Kamm, R. D., & Nikkhah, M. (2016) · Scientific Reports · doi:10.1038/srep34094 · Cited by 135
Self-citationFabrication of 3D Biomimetic Microfluidic Networks in Hydrogels
Heintz, K. A., Bregenzer, M. E., Mantle, J. L., Lee, K. H., West, J. L., & Slater, J. H. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201600351 · Cited by 137
Shirure, V. S., & George, S. C. (2017) · Lab on a Chip · doi:10.1039/c6lc01401a · Cited by 135
Development and characterization of a microfluidic model of the tumour microenvironment
Ayuso, J. M., Virumbrales-Muñoz, M., Lacueva, A., Lanuza, P. M., Checa-Chavarria, E., Botella, P., Fernández, E., Doblare, M., Allison, S. J., Phillips, R. M., et al. (2016) · Scientific Reports · doi:10.1038/srep36086 · Cited by 134
New experimental models of the blood-brain barrier for CNS drug discovery
Kaisar, M. A., Sajja, R. K., Prasad, S., Abhyankar, V. V., Liles, T., & Cucullo, L. (2017) · Expert Opinion on Drug Discovery · doi:10.1080/17460441.2017.1253676 · Cited by 135
“cell proliferation, cell migration [68,74], inflammation [67], drug toxicity [75], and tumor cell invasion [79].”
BackgroundEngineered models to parse apart the metastatic cascade
Hapach, L. A., Mosier, J. A., Wang, W., & Reinhart‐King, C. A. (2019) · npj Precision Oncology · doi:10.1038/s41698-019-0092-3 · Cited by 160
Live-Cell Imaging of Invasion and Intravasation in an Artificial Microvessel Platform
Wong, A. D., & Searson, P. C. (2014) · Cancer Research · doi:10.1158/0008-5472.can-14-1042 · Cited by 132
“Intravasation has been less well studied and until now has been largely limited to in vivo observations and 2D in vitro assays lacking physiologic shear stress and a relevant geometry (16, 26, 27).”
3D-printed fluidic networks as vasculature for engineered tissue
Kinstlinger, I. S., & Miller, J. S. (2016) · Lab on a Chip · doi:10.1039/c6lc00193a · Cited by 131
Lin, Z., Luo, G., Du, W., Kong, T., Liu, C., & Liu, Z. (2019) · Small · doi:10.1002/smll.201903899 · Cited by 138
The fluid shear stress sensor TRPM7 regulates tumor cell intravasation
Yankaskas, C. L., Bera, K., Stoletov, K. V., Serra, S. A., Carrillo-García, J., Tuntithavornwat, S., Mistriotis, P., Lewis, J. D., Valverde, M. A., & Κωνσταντόπουλος, Κ. (2021) · Science Advances · doi:10.1126/sciadv.abh3457 · Cited by 137
Enabling personalized implant and controllable biosystem development through 3D printing
Nagarajan, N., Dupret‐Bories, A., Karabulut, E., Zorlutuna, P., & Vrana, N. E. (2018) · Biotechnology Advances · doi:10.1016/j.biotechadv.2018.02.004 · Cited by 143
A microfluidic platform for quantitative analysis of cancer angiogenesis and intravasation
Lee, H., Park, W., Ryu, H., & Jeon, N. L. (2014) · Biomicrofluidics · doi:10.1063/1.4894595 · Cited by 130
New materials for microfluidics in biology
Ren, K., Chen, Y., & Wu, H. (2013) · Current Opinion in Biotechnology · doi:10.1016/j.copbio.2013.09.004 · Cited by 156
“Kamm demonstrated the use of similar design in the study of tumor cell intravasation and endothelial barrier function [31].”
MethodTumor-on-chip modeling of organ-specific cancer and metastasis
Del Piccolo, N., Shirure, V. S., Bi, Y., Goedegebuure, S. P., Gholami, S., Hughes, C. C. W., Fields, R. C., & George, S. C. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.05.008 · Cited by 126
“Microfluidic models that incorporate the microvasculature—either through patterning techniques [73,74] or self-organization of ECs [75,76]—enable study of angiogenesis and intravasation in the BC TME.”
BackgroundMethodApplications of tumor chip technology
Hachey, S. J., & Hughes, C. C. W. (2018) · Lab on a Chip · doi:10.1039/c8lc00330k · Cited by 128
LumeNEXT: A Practical Method to Pattern Luminal Structures in ECM Gels
Jiménez‐Torres, J. A., Peery, S. L., Sung, K. E., & Beebe, D. J. (2016) · Advanced Healthcare Materials · doi:10.1002/adhm.201500608 · Cited by 132
Microengineered cancer-on-a-chip platforms to study the metastatic microenvironment
Portillo-Lara, R., & Annabi, N. (2016) · Lab on a Chip · doi:10.1039/c6lc00718j · Cited by 127
Digital Light Processing Bioprinting Advances for Microtissue Models
Hosseinabadi, H. G., Dogan, E., Miri, A. K., & Ionov, L. (2022) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.1c01509 · Cited by 144
Biomimetic Model of Tumor Microenvironment on Microfluidic Platform
Chung, M., Ahn, J., Son, K., Kim, S., & Jeon, N. L. (2017) · Advanced Healthcare Materials · doi:10.1002/adhm.201700196 · Cited by 126
Endothelial Regulation of Drug Transport in a 3D Vascularized Tumor Model
Haase, K., Offeddu, G. S., Gillrie, M. R., & Kamm, R. D. (2020) · Advanced Functional Materials · doi:10.1002/adfm.202002444 · Cited by 127
Self-citationApplications of Microfluidics and Organ-on-a-Chip in Cancer Research
Regmi, S., Poudel, C., Adhikari, R., & Luo, K. Q. (2022) · Biosensors · doi:10.3390/bios12070459 · Cited by 143
Polysaccharide matrices used in 3D in vitro cell culture systems
Diekjürgen, D., & Grainger, D. W. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.06.020 · Cited by 125
3D Bioprinting at the Frontier of Regenerative Medicine, Pharmaceutical, and Food Industries
Ramadan, Q., & Zourob, M. M. (2021) · Frontiers in Medical Technology · doi:10.3389/fmedt.2020.607648 · Cited by 142
Metastasis in context: modeling the tumor microenvironment with cancer-on-a-chip approaches
Sleeboom, J. J. F., Eslami Amirabadi, H., Nair, P., Sahlgren, C. M., & den Toonder, J. M. J. (2018) · Disease Models & Mechanisms · doi:10.1242/dmm.033100 · Cited by 122
“For example, the previously mentioned compartmentalized chip from Zervantonakis et al. (2012) contains a rectangular channel lined with ECs.”
Hydrogels: The Next Generation Body Materials for Microfluidic Chips?
Nie, J., Fu, J., & He, Y. (2020) · Small · doi:10.1002/smll.202003797 · Cited by 130
Belair, D. G., Whisler, J. A., Valdez, J., Velazquez, J., Molenda, J. A., Vickerman, V., Lewis, R., Daigh, C., Hansen, T. D., Mann, D. A., et al. (2015) · Stem Cell Reviews and Reports · doi:10.1007/s12015-014-9549-5 · Cited by 120
Self-citationKim, J., Lee, C., Kim, I., Ro, J., Kim, J., Min, Y. H., Park, J., Sunkara, V., Park, Y.-S., Michael, I. J., et al. (2020) · ACS Nano · doi:10.1021/acsnano.0c04778 · Cited by 135
Li, W., Zhou, Z., Zhou, X., Khoo, B. L., Gunawan, R., Chin, Y. R., Zhang, L., Yi, C., Guan, X., & Yang, M. (2023) · Advanced Healthcare Materials · doi:10.1002/adhm.202202609 · Cited by 119
Role of Microenvironment in Glioma Invasion: What We Learned from In Vitro Models
Manini, I., Caponnetto, F., Bartolini, A., Ius, T., Mariuzzi, L., Loreto, C. D., Beltrami, A. P., & Cesselli, D. (2018) · International Journal of Molecular Sciences · doi:10.3390/ijms19010147 · Cited by 139
“This model represents a platform that can be studied by high resolution live cell imaging [193].”
BackgroundXiao, Y., Kim, D., Dura, B., Zhang, K., Yan, R., Li, H., Han, E., Ip, J., Zou, P., Liu, J., et al. (2019) · Advanced Science · doi:10.1002/advs.201801531 · Cited by 115
In Vitro Strategies to Vascularize 3D Physiologically Relevant Models
Dellaquila, A., Le Bao, C., Letourneur, D., & Simon‐Yarza, T. (2021) · Advanced Science · doi:10.1002/advs.202100798 · Cited by 115
Evaluating Biomaterial- and Microfluidic-Based 3D Tumor Models
Carvalho, M. R., Lima, D., Reis, R. L., Correlo, V. M., & Oliveira, J. M. (2015) · Trends in biotechnology · doi:10.1016/j.tibtech.2015.09.009 · Cited by 122
“However, an in vitro 3D microfluidic model of the tumor– vascular interface was designed to integrate live imaging, precise control of microenvironmental factors, and endothelial barrier measurement [52].”
Cancer Modeling‐on‐a‐Chip with Future Artificial Intelligence Integration
Fetah, K., DiPardo, B. J., Kongadzem, E.-M. L., Tomlinson, J. S., Elzagheid, A. I., Elmusrati, M. S., Khademhosseini, A., & Ashammakhi, N. A. (2019) · Small · doi:10.1002/smll.201901985 · Cited by 121
Engineering the vasculature for islet transplantation
Bowers, D. T., Song, W., Wang, L.-H., & Ma, M. (2019) · Acta Biomaterialia · doi:10.1016/j.actbio.2019.05.051 · Cited by 115
Modulation of the Tumor Microenvironment for Cancer Treatment: A Biomaterials Approach
Adjei, I. M., & Sharma, B. (2015) · Journal of Functional Biomaterials · doi:10.3390/jfb6010081 · Cited by 133
“One such model utilizes a 3D ECM-hollow endothelial channel that allows the monitoring of cancer cell movement across the lumen [91].”
MethodBruce, A., Evans, R., Mezan, R., Shi, L., Moses, B. S., Martin, K. H., Gibson, L. F., & Yang, Y. (2015) · PLOS ONE · doi:10.1371/journal.pone.0140506 · Cited by 112
Engineering Breast Cancer Microenvironments and 3D Bioprinting
Belgodere, J. A., King, C. T., Bursavich, J. B., Burow, M. E., Martin, E. C., & Jung, J. P. (2018) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2018.00066 · Cited by 109
“Utilizing the precise patterning and control of microfluidics, 3D vascular networks can be constructed to examine how cancer cells extravasate (Chen et al., 2013; Jeon et al., 2015) and intravasate (Zervantonakis et al., 2012) during metastasis.”
BackgroundAdaptive Stress Responses During Tumor Metastasis and Dormancy
Senft, D., & Ronai, Z. A. (2016) · Trends in cancer · doi:10.1016/j.trecan.2016.06.004 · Cited by 124
“Because tumor blood vessels differ from the normal vasculature in terms of endothelial barrier function, angiogenesis may increase invasion [107].”
BackgroundZhang, J., Tavakoli, H., Ma, L., Li, X., Han, L., & Li, X. (2022) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2022.114365 · Cited by 114
Organ-on-a-chip platforms for accelerating the evaluation of nanomedicine
Chen, X., Zhang, Y. S., Zhang, X., & Liu, C. (2021) · Bioactive Materials · doi:10.1016/j.bioactmat.2020.09.022 · Cited by 107
Wang, X., Sun, Q., & Pei, J. (2018) · Micromachines · doi:10.3390/mi9100493 · Cited by 106
“They found that macrophage-secreted tumor necrosis factor alpha (TNF-α) could enhance breast cancer cell intravasation due to impaired endothelial barrier function [124].”
BackgroundMethodGel integration for microfluidic applications
Zhang, X., Li, L., & Luo, C. (2016) · Lab on a Chip · doi:10.1039/c6lc00247a · Cited by 117
Integrating Organs-on-Chips: Multiplexing, Scaling, Vascularization, and Innervation
Park, D., Lee, J., Chung, J. J., Jung, Y., & Kim, S. H. (2020) · Trends in Biotechnology · doi:10.1016/j.tibtech.2019.06.006 · Cited by 105
Lugo-Cintrón, K. M., Gong, M. M., Ayuso, J. M., Tomko, L. A., Beebe, D. J., Virumbrales-Muñoz, M., & Ponik, S. M. (2020) · Cancers · doi:10.3390/cancers12051173 · Cited by 103
“In the context of breast cancer migration, microfluidic models have been developed to co-culture cancer cells with components, such as blood vessels [34], lymphatic vessels [35] and immune cells [36].”
MethodOrgan-on-a-chip engineering: Toward bridging the gap between lab and industry
Ramadan, Q., & Zourob, M. M. (2020) · Biomicrofluidics · doi:10.1063/5.0011583 · Cited by 113
Badr-Eldin, S. M., Aldawsari, H. M., Kotta, S., Deb, P. K., & Venugopala, K. N. (2022) · Pharmaceuticals · doi:10.3390/ph15080926 · Cited by 119
“The small amount of microfluidics for the fabrication of a small number of cells can result in the production of biomimetic models with in vivo tumor microenvironment [85], different types of cells [86], and biochemical gradients [87].”
BackgroundHo, Y. T., Kamm, R. D., & Kah, J. C. Y. (2018) · Nanoscale · doi:10.1039/c8nr02393j · Cited by 102
Self-citationTang, Y., Soroush, F., Sheffield, J. B., Wang, B., Prabhakarpandian, B., & Kiani, M. F. (2017) · Scientific Reports · doi:10.1038/s41598-017-09815-9 · Cited by 102
Advanced model systems and tools for basic and translational human immunology
Wagar, L. E., DiFazio, R. M., & Davis, M. M. (2018) · Genome Medicine · doi:10.1186/s13073-018-0584-8 · Cited by 102
Li, R., Hebert, J. D., Lee, T. A., Xing, H., Boussommier-Calleja, A., Hynes, R. O., Lauffenburger, D. A., & Kamm, R. D. (2017) · Cancer Research · doi:10.1158/0008-5472.can-16-0442 · Cited by 100
“Moreover, in vivo and in vitro studies have shown that macrophages enhance cancer cell intravasation (11,12) and invasion through various signaling pathways (13,14).”
BackgroundSelf-citationSimultaneous or Sequential Orthogonal Gradient Formation in a 3D Cell Culture Microfluidic Platform
Uzel, S. G. M., Amadi, O. C., Pearl, T. M., Lee, R. T., So, P. T. C., & Kamm, R. D. (2016) · Small · doi:10.1002/smll.201501905 · Cited by 100
Self-citationThe emergence of 3D bioprinting in organ-on-chip systems
Fetah, K., Tebon, P., Goudie, M. J., Eichenbaum, J., Ren, L., Barros, N., Nasiri, R., Ahadian, S., Ashammakhi, N., Dokmeci, M. R., et al. (2019) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/ab23df · Cited by 98
Grafting of 3D Bioprinting to In Vitro Drug Screening: A Review
Nie, J., Gao, Q., Fu, J., & He, Y. (2020) · Advanced Healthcare Materials · doi:10.1002/adhm.201901773 · Cited by 106
A Microvascularized Tumor-mimetic Platform for Assessing Anti-cancer Drug Efficacy
Pradhan, S., Smith, A. M., Garson, C. J., Hassani, I., Seeto, W. J., Pant, K., Arnold, R. D., Prabhakarpandian, B., & Lipke, E. A. (2018) · Scientific Reports · doi:10.1038/s41598-018-21075-9 · Cited by 96
Circulating tumor cells: Blood-based detection, molecular biology, and clinical applications
Dai, C. S., Mishra, A., Edd, J., Toner, M., Maheswaran, S., & Haber, D. A. (2025) · Cancer Cell · doi:10.1016/j.ccell.2025.07.008 · Cited by 129
A microfluidics assay to study invasion of human placental trophoblast cells
Abbas, Y., Oefner, C. M., Polacheck, W. J., Gardner, L., Farrell, L. E., Sharkey, A., Kamm, R. D., Moffett, A., & Oyen, M. L. (2017) · Journal of The Royal Society Interface · doi:10.1098/rsif.2017.0131 · Cited by 106
Self-citationvan Dijk, C. G. M., Brandt, M. M., Poulis, N., Anten, J., van der Moolen, M., Kramer, L., Homburg, E. F. G. A., Louzao-Martinez, L., Pei, J., Krebber, M. M., et al. (2020) · Lab on a Chip · doi:10.1039/d0lc00059k · Cited by 103
3D cancer models: One step closer to in vitro human studies
Manduca, N., Maccafeo, E., Maria, R. D., Sistigu, A., & Musella, M. (2023) · Frontiers in Immunology · doi:10.3389/fimmu.2023.1175503 · Cited by 111
Engineering approaches for studying immune-tumor cell interactions and immunotherapy
Shelton, S. E., Nguyen, H. T., Barbie, D. A., & Kamm, R. D. (2021) · iScience · doi:10.1016/j.isci.2020.101985 · Cited by 93
“One such study examined the role of immune cells in metastasis to observe the process by which macrophages assist tumor cells intravasation (Zervantonakis et al., 2012).”
BackgroundSelf-citationMicrofluidic-based vascularized microphysiological systems
Lee, S., Ko, J., Park, D., Lee, S.-R., Chung, M., Lee, Y., & Jeon, N. L. (2018) · Lab on a Chip · doi:10.1039/c8lc00285a · Cited by 91
Current Advances in 3D Bioprinting for Cancer Modeling and Personalized Medicine
Germain, N., Dhayer, M., Dekiouk, S., & Marchetti, P. (2022) · International Journal of Molecular Sciences · doi:10.3390/ijms23073432 · Cited by 103
“, 3D breast adenocarcinoma bioprinted models associated with microfluidics can recapitulate changes in the endothelial barrier caused by tumor–endothelial cells interactions and model the process of intravasation [161].”
BackgroundPeela, N., Truong, D., Saini, H., Chu, H., Mashaghi, S., Ham, S. L., Singh, S., Tavana, H., Mosadegh, B., & Nikkhah, M. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.04.017 · Cited by 91
“Moreover, the endothelium was treated with TNF-a to study the effect of pro-inflammatory cues on the endothelial barrier, which subsequently resulted in increased permeability and cancer extravasation rate.”
BackgroundInfluentialSaha, B., Mathur, T., Tronolone, J. J., Chokshi, M., Lokhande, G. K., Selahi, A., Gaharwar, A. K., Afshar-Kharghan, V., Sood, A. K., Bao, G., et al. (2021) · Science Advances · doi:10.1126/sciadv.abg5283 · Cited by 90
“This relative simplicity and a provision to do analytics is a strength of our OTME-Chip, which is also not radically different from its prior versions (20) and consistent with prior models (39).”
ResultEngineered Liver Platforms for Different Phases of Drug Development
Ware, B. R., & Khetani, S. R. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2016.08.001 · Cited by 90
“Similar techniques have been used with liver-tumor interactions for studying endothelial permeability [69].”
MethodAntmen, E., Vrana, N. E., & Hasırcı, V. (2021) · Biomaterials Science · doi:10.1039/d1bm00840d · Cited by 97
Nie, J., Gao, Q., Xie, C., Lv, S., Qiu, J., Liu, Y., Guo, M. A., Guo, R., Fu, J., & He, Y. (2020) · Materials Horizons · doi:10.1039/c9mh01283d · Cited by 91
Microfluidic platform for studying osteocyte mechanoregulation of breast cancer bone metastasis
Mei, X., Middleton, K., Shim, D., Wan, Q., Xu, L., Ma, Y.-H. V., Devadas, D., Walji, N., Wang, L., Young, E. W. K., et al. (2019) · Integrative Biology · doi:10.1093/intbio/zyz008 · Cited by 87
A bioengineered array of 3D microvessels for vascular permeability assay
Lee, H., Kim, S., Chung, M., Kim, J. H., & Jeon, N. L. (2013) · Microvascular Research · doi:10.1016/j.mvr.2013.12.001 · Cited by 99
Ozcelikkale, A., Moon, H., Linnes, M., & Han, B. (2017) · WIREs Nanomedicine and Nanobiotechnology · doi:10.1002/wnan.1460 · Cited by 87
Song, J., Miermont, A., Lim, C. T., & Kamm, R. D. (2018) · Scientific Reports · doi:10.1038/s41598-018-36381-5 · Cited by 87
Self-citationGill, B. J., & West, J. L. (2014) · Journal of Biomechanics · doi:10.1016/j.jbiomech.2013.09.029 · Cited by 86
“Tumor co-culture with angiogenic cells in naturally derived materials have also been deployed in microfluidic systems by the Kamm lab and others (Polacheck et al., 2011; Zervantonakis et al., 2012).”
MethodStudying the influence of angiogenesis in in vitro cancer model systems
Roudsari, L. C., & West, J. L. (2015) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2015.11.004 · Cited by 98
“It was observed that RPMI 7951, amelanoma cell line derived from a lymph nodemetastasis, enhanced angiogenesis and HUVEC migration, while other melanoma cell lines (primary tumor-derived A375 and SK MEL 28; lung metastasis-derived Malme 3 M) did not.”
BackgroundMethodInfluentialControlling Differentiation of Stem Cells for Developing Personalized Organ‐on‐Chip Platforms
Geraili, A., Jafari, P., Hassani, M. S., Araghi, B. H., Mohammadi, M. H., Ghafari, A. M., Tamrin, S. H., Modarres, H. P., Kolahchi, A. R., Ahadian, S., et al. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201700426 · Cited by 88
Engineering and monitoring cellular barrier models
Yeste, J., Illa, X., Álvarez, M., & Villa, R. (2018) · Journal of Biological Engineering · doi:10.1186/s13036-018-0108-5 · Cited by 100
“, migration towards blood vessels) under TNFα exposure [122] or tumour cell extravasation (i.”
Background3D tumor angiogenesis models: recent advances and challenges
Bhat, S. M., Badiger, V. A., Vasishta, S., Chakraborty, J., Seetharam, P., Ghosh, S., & Joshi, M. B. (2021) · Journal of Cancer Research and Clinical Oncology · doi:10.1007/s00432-021-03814-0 · Cited by 95
Cancer cells remodel themselves and vasculature to overcome the endothelial barrier
Shenoy, A. K., & Lu, J. (2014) · Cancer Letters · doi:10.1016/j.canlet.2014.10.031 · Cited by 93
Fu, C.-Y., Tseng, S.-Y., Yang, S.-M., Hsu, L., Liu, C.-H., & Chang, H.-Y. (2014) · Biofabrication · doi:10.1088/1758-5082/6/1/015009 · Cited by 86
“For example, a tumor cell intravasation model for endothelial barrier function analysis has been established in a microfluidic chip [25].”
BackgroundTransforming Nanomedicines From Lab Scale Production to Novel Clinical Modality
Landesman-Milo, D., & Peer, D. (2016) · Bioconjugate Chemistry · doi:10.1021/acs.bioconjchem.5b00607 · Cited by 86
Sabhachandani, P., Sarkar, S., Mckenney, S., Ravi, D., Evens, A. M., & Konry, T. (2019) · Journal of Controlled Release · doi:10.1016/j.jconrel.2018.12.010 · Cited by 87
Microfluidic co-culture system for cancer migratory analysis and anti-metastatic drugs screening
Mi, S., Du, Z., Xu, Y., Wu, Z., Qian, X., Zhang, M., & Sun, W. (2016) · Scientific Reports · doi:10.1038/srep35544 · Cited by 83
“…based on microfluidic devices, and some scholars have established co-culture tumour models in microfluidic devices to solely study cancer cell migration 11,27 , only a few studies have focused on the interaction between cells and studied the role of normal cells in breast cancer migration 10,28 .”
Recent advances in microfluidic technologies for organ-on-a-chip
Tian, C., Tu, Q., Liu, W., & Wang, J. (2019) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2019.06.005 · Cited by 90
Polymeric Biomaterials for In Vitro Cancer Tissue Engineering and Drug Testing Applications
Pradhan, S., Hassani, I., Clary, J. M., & Lipke, E. A. (2016) · Tissue Engineering Part B: Reviews · doi:10.1089/ten.teb.2015.0567 · Cited by 86
Microphysiological Systems: Design, Fabrication, and Applications
Wang, K., Man, K., Liu, J., Liu, Y., Chen, Q., Zhou, Y., & Yang, Y. S. (2020) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.9b01667 · Cited by 90
Lim, J., Ching, H., Yoon, J., Jeon, N. L., & Kim, Y. (2021) · Nano Convergence · doi:10.1186/s40580-021-00261-y · Cited by 91
Assembly of complex cell microenvironments using geometrically docked hydrogel shapes
Eng, G. M., Lee, B. W., Parsa, H., Chin, C. D., Schneider, J., Linkov, G., Sia, S. K., & Vunjak‐Novakovic, G. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1300569110 · Cited by 89
Immunocompetent cancer-on-chip models to assess immuno-oncology therapy
Maulana, T. I., Kromidas, E., Wallstabe, L., Cipriano, M., Alb, M., Zaupa, C., Hudecek, M., Fogal, B., & Loskill, P. (2021) · Advanced Drug Delivery Reviews · doi:10.1016/j.addr.2021.03.015 · Cited by 93
Techniques and assays for the study of angiogenesis
Irvin, M., Zijlstra, A., Wikswo, J. P., & Pozzi, A. (2014) · Experimental Biology and Medicine · doi:10.1177/1535370214529386 · Cited by 94
“They are also well suited for the study of tumor cell intravasation and endothelial permeability.(60) The three-dimensional printing of trees has been largely limited to large-diameter networks, primarily by the spatial resolution with which three-dimensional printing can deliver living cells and matrix.”
Rodenhizer, D., Dean, T., D'Arcangelo, E., & McGuigan, A. P. (2018) · Advanced Healthcare Materials · doi:10.1002/adhm.201701174 · Cited by 80
Complex 3D microfluidic architectures formed by mechanically guided compressive buckling
Luan, H., Zhang, Q., Liu, T., Wang, X. S., Zhao, S., Wang, H., Yao, S., Xue, Y., Kwak, J. W., Bai, W., et al. (2021) · Science Advances · doi:10.1126/sciadv.abj3686 · Cited by 84
Metadata
- Authors
- Zervantonakis, I. K., Hughes-Alford, S. K., Charest, J. L., Condeelis, J. S., Gertler, F. B., & Kamm, R. D.
- Affiliations
- Massachusetts Institute of Technology (US)
- Biological Engineering, and
- Draper Laboratory (US)
- Albert Einstein College of Medicine (US)
- Koch Institute for Integrative Cancer Research At MIT (US)
- Departments of Mechanical Engineering,
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2012-08-06
- Volume
- 109
- Issue
- 34
- Pages
- 13515-13520
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC3427099
- OpenAlex
- W2088004044
- Cited by
- 872
- References
- 46
- Citations by year
- 2026: 34 · 2025: 35 · 2024: 45 · 2023: 51 · 2022: 54 · 2021: 87 · 2020: 98 · 2019: 75 · 2018: 75 · 2017: 76 · 2016: 82 · 2015: 58 · 2014: 56 · 2013: 37 · 2012: 7
- FWCI
- 24.99
- Type
- journal article
- Language
- en
- Open access
- green
- www.ncbi.nlm.nih.gov
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion)
- Europe PMC (PubMed Central) (publishedVersion)
- PubMed Central (publishedVersion)
- PubMed (publishedVersion)
- DSpace@MIT (Massachusetts Institute of Technology) (submittedVersion, cc-by-nc)
- Funders
- National Cancer Institute (P01CA100324, R21CA140096, CA 100324)
- National Institute of General Medical Sciences (GM-58801, R01GM058801)
- Topics
- Health Sciences › Medicine › Oncology › Cancer Cells and Metastasis
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Molecular Biology › Angiogenesis and VEGF in Cancer
- Life Sciences › Neuroscience › Neurology › Barrier Structure and Function Studies
- Keywords
- tumor cell intravasation, endothelial barrier function, metastasis, TNF-α, macrophages, endothelial permeability, tumor microenvironment, fibrosarcoma cells, tumor cell migration, microfluidic assay, 3D model
- MeSH terms
- Cell Communication, Cell Movement, Humans, Macrophages, Neoplasm Metastasis, Neoplasms, Permeability, Tumor Necrosis Factor-alpha, Signal Transduction, Hydrogel, Polyethylene Glycol Dimethacrylate, Imaging, Three-Dimensional, Endothelial Cells, Microfluidics, Cell Line, Tumor
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.