Counting single photoactivatable fluorescent molecules by photoactivated localization microscopy (PALM)
Open accessThe DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
We present a single molecule method for counting proteins within a diffraction-limited area when using photoactivated localization microscopy. The intrinsic blinking of photoactivatable fluorescent proteins mEos2 and Dendra2 leads to an overcounting error, which constitutes a major obstacle for their use as molecular counting tags. Here, we introduce a kinetic model to describe blinking and show that Dendra2 photobleaches three times faster and blinks seven times less than mEos2, making Dendra2 a better photoactivated localization microscopy tag than mEos2 for molecular counting. The simultaneous activation of multiple molecules is another source of error, but it leads to molecular undercounting instead. We propose a photoactivation scheme that maximally separates the activation of different molecules, thus helping to overcome undercounting. We also present a method that quantifies the total counting error and minimizes it by balancing over- and undercounting. This unique method establishes that Dendra2 is better for counting purposes than mEos2, allowing us to count in vitro up to 200 molecules in a diffraction-limited spot with a bias smaller than 2% and an uncertainty less than 6% within 10 min. Finally, we demonstrate that this counting method can be applied to protein quantification in vivo by counting the bacterial flagellar motor protein FliM fused to Dendra2.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Precise Nanometer Localization Analysis for Individual Fluorescent Probes
Thompson, R. E., Larson, D. R., & Webb, W. W. (2002) · Biophysical Journal · doi:10.1016/s0006-3495(02)75618-x · Cited by 2,320
Quantifying E. coli Proteome and Transcriptome with Single-Molecule Sensitivity in Single Cells
Taniguchi, Y., Choi, P. J., Li, G.-W., Chen, H., Babu, M., Hearn, J., Emili, A., & Xie, X. S. (2010) · Science · doi:10.1126/science.1188308 · Cited by 1,982 · cited 1×
“Optical microscopy with fluorescent proteins provides a much less invasive alternative and allows quantification of proteins with single molecule sensitivity (1, 2).”
BackgroundSubunit counting in membrane-bound proteins
Ulbrich, M. H., & Isacoff, E. Y. (2007) · Nature Methods · doi:10.1038/nmeth1024 · Cited by 690
Photoactivatable mCherry for high-resolution two-color fluorescence microscopy
Subach, F. V., Patterson, G. H., Manley, S., Gillette, J. M., Lippincott-Schwartz, J., & Verkhusha, V. V. (2009) · Nature Methods · doi:10.1038/nmeth.1298 · Cited by 607
Single-molecule high-resolution imaging with photobleaching
Gordon, M. P., Ha, T., & Selvin, P. R. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0401638101 · Cited by 372
Greenfield, D., McEvoy, A. L., Shroff, H., Crooks, G. E., Wingreen, N. S., Betzig, E., & Liphardt, J. (2009) · PLoS Biology · doi:10.1371/journal.pbio.1000137 · Cited by 328
Sourjik, V., & Berg, H. C. (2000) · Molecular Microbiology · doi:10.1046/j.1365-2958.2000.02044.x · Cited by 311
Nanometer-localized multiple single-molecule fluorescence microscopy
Qu, X., Wu, D., Mets, L., & Scherer, N. F. (2004) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0402155101 · Cited by 304
Quantitative Photo Activated Localization Microscopy: Unraveling the Effects of Photoblinking
Annibale, P., Vanni, S., Scarselli, M., Rothlisberger, U., & Radenovic, A. (2011) · PLoS ONE · doi:10.1371/journal.pone.0022678 · Cited by 262
Identification of clustering artifacts in photoactivated localization microscopy
Annibale, P., Vanni, S., Scarselli, M., Rothlisberger, U., & Radenovic, A. (2011) · Nature Methods · doi:10.1038/nmeth.1627 · Cited by 212
Signal-dependent turnover of the bacterial flagellar switch protein FliM
Delalez, N. J., Wadhams, G. H., Rosser, G., Xue, Q., Brown, M. T., Dobbie, I. M., Berry, R. M., Leake, M. C., & Armitage, J. P. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1000284107 · Cited by 173
A Stroboscopic Approach for Fast Photoactivation−Localization Microscopy with Dronpa Mutants
Flors, C., Hotta, J., Uji‐i, H., Dedecker, P., Ando, R., Mizuno, H., Miyawaki, A., & Hofkens, J. (2007) · Journal of the American Chemical Society · doi:10.1021/ja074704l · Cited by 158
Quantifying E. coli Proteome and Transcriptome with Single-molecule Sensitivity in Single Cells
Taniguchi, Y. (2011) · Seibutsu Butsuri · doi:10.2142/biophys.51.136 · Cited by 157
Rotational symmetry of the C ring and a mechanism for the flagellar rotary motor
Thomas, D. R., Morgan, D. G., & DeRosier, D. J. (1999) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.96.18.10134 · Cited by 141
McEvoy, A. L., Greenfield, D., Shroff, H., Crooks, G. E., Wingreen, N. S., Betzig, E., & Liphardt, J. (2010) · Biophysical Journal · doi:10.1016/j.bpj.2009.12.4175 · Cited by 126
Assembly and stability of flagellar motor in Escherichia coli
Li, H., & Sourjik, V. (2011) · Molecular Microbiology · doi:10.1111/j.1365-2958.2011.07557.x · Cited by 120
Dynamic SpoIIIE assembly mediates septal membrane fission during Bacillus subtilis sporulation
Fleming, T. C., Shin, J. Y., Lee, S.-H., Becker, E. C., Huang, K. C., Bustamante, C., & Pogliano, K. (2010) · Genes & Development · doi:10.1101/gad.1925210 · Cited by 72
Self-citationVariable Symmetry in Salmonella typhimurium Flagellar Motors
Young, H. S., Dang, H., Lai, Y., DeRosier, D. J., & Khan, S. (2003) · Biophysical Journal · doi:10.1016/s0006-3495(03)74877-2 · Cited by 64
Cited by
Super-resolution microscopy with DNA-PAINT
Schnitzbauer, J., Strauss, M. T., Schlichthaerle, T., Schueder, F., & Jungmann, R. (2017) · Nature Protocols · doi:10.1038/nprot.2017.024 · Cited by 1,047
Fluorescence nanoscopy in cell biology
Sahl, S. J., Hell, S. W., & Jakobs, S. (2017) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2017.71 · Cited by 990
Single-molecule localization microscopy
Lelek, M., Gyparaki, M. T., Beliu, G., Schueder, F., Griffié, J., Manley, S., Jungmann, R., Sauer, M., Lakadamyali, M., & Zimmer, C. (2021) · Nature Reviews Methods Primers · doi:10.1038/s43586-021-00038-x · Cited by 954
Visualizing and discovering cellular structures with super-resolution microscopy
Sigal, Y. M., Zhou, R., & Zhuang, X. (2018) · Science · doi:10.1126/science.aau1044 · Cited by 718
SR-Tesseler: a method to segment and quantify localization-based super-resolution microscopy data
Levet, F., Hosy, E., Kechkar, A., Butler, C., Beghin, A., Choquet, D., & Sibarita, J.-B. (2015) · Nature Methods · doi:10.1038/nmeth.3579 · Cited by 502
Metadata
- Authors
- Lee, S.-H., Shin, J. Y., Lee, A., & Bustamante, C.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2012-10-08
- Volume
- 109
- Issue
- 43
- Pages
- 17436-17441
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2139868016
- Cited by
- 379
- References
- 19
- FWCI
- 14.48
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.