The DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Mechanisms of sampling interstitial fluid from skin using a microneedle patch
Open accessAbstract
Significance: Diagnosis and monitoring of disease is often done by measuring biomarkers found in blood, urine, saliva, and other bodily fluids. Another rich source of biomarkers is the interstitial fluid that surrounds cells and tissues in the body, but difficulty in accessing this fluid has limited its use in research and medicine. Here, we conducted experimental studies coupled with theoretical modeling to design a patch containing microscopic needles that puncture into superficial layers of skin and thereby enable withdrawal of interstitial fluid through micropores in a simple, minimally invasive manner. This patch can help researchers access interstitial fluid to advance discovery of novel biomarkers and enable doctors to use interstitial fluid for possible future diagnosis and monitoring of disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chang, H., Zheng, M., Yu, X., Than, A., Seeni, R. Z., Kang, R., Tian, J., Khanh, D. P., Liu, L., Chen, P., et al. (2017) · Advanced Materials · doi:10.1002/adma.201702243 · Cited by 462
Suction Blister Device for Separation of Viable Epidermis from Dermis*
Kiistala, U. (1968) · Journal of Investigative Dermatology · doi:10.1038/jid.1968.15 · Cited by 448
Engineering Microneedle Patches for Vaccination and Drug Delivery to Skin
Prausnitz, M. R. (2017) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-060816-101514 · Cited by 439
Self-citationSkin models for the testing of transdermal drugs
Abd, E., Yousuf, S., Pastore, M., Telaprolu, K., Mohammed, Y., Namjoshi, S., Grice, J., & Roberts, M. (2016) · Clinical Pharmacology: Advances and Applications · doi:10.2147/cpaa.s64788 · Cited by 413
Interstitial fluid volume: local regulatory mechanisms.
Aukland, K., & Nicolaysen, G. (1981) · Physiological Reviews · doi:10.1152/physrev.1981.61.3.556 · Cited by 402
Slupsky, C. M., Rankin, K. N., Wagner, J., Fu, H., Chang, D., Weljie, A. M., Saude, E. J., Lix, B., Adamko, D. J., Shah, S., et al. (2007) · Analytical Chemistry · doi:10.1021/ac0708588 · Cited by 401
Microneedle array for transdermal biological fluid extraction and in situ analysis
Mukerjee, E. V., Collins, S. D., Isseroff, R. R., & Smith, R. L. (2004) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2003.11.008 · Cited by 340
Clinical and diagnostic utility of saliva as a non-invasive diagnostic fluid: a systematic review
Soares Nunes, L. A., Mussavira, S., & Sukumaran Bindhu, O. (2015) · Biochemia Medica · doi:10.11613/bm.2015.018 · Cited by 333
Prausnitz, M. R., Mikszta, J. A., Cormier, M., & Andrianov, A. K. (2009) · Current Topics in Microbiology and Immunology · doi:10.1007/978-3-540-92165-3_18 · Cited by 314
Self-citationComposition of interstitial fluid
Fogh-Andersen, N., Altura, B. M., Altura, B. T., & Siggaard-Andersen, O. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.10.1522 · Cited by 309
Minimally Invasive Extraction of Dermal Interstitial Fluid for Glucose Monitoring Using Microneedles
Wang, P. M., Cornwell, M., & Prausnitz, M. R. (2005) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2005.7.131 · Cited by 267
Self-citationCapillary Fluid Exchange: Regulation, Functions, and Pathology
Scallan, J., Huxley, V. H., & Korthuis, R. J. (2010) · Colloquium Series on Integrated Systems Physiology: From Molecule to Function · doi:10.4199/c00006ed1v01y201002isp003 · Cited by 256
An Updated Review of the Efficacy of Cupping Therapy
Cao, H., Li, X., & Liu, J. (2012) · PLoS ONE · doi:10.1371/journal.pone.0031793 · Cited by 240
Arya, J., Henry, S., Kalluri, H., McAllister, D. V., Pewin, W. P., & Prausnitz, M. R. (2017) · Biomaterials · doi:10.1016/j.biomaterials.2017.02.040 · Cited by 237
Self-citationEWMA Document: Negative Pressure Wound Therapy: Overview, Challenges and Perspectives
Apelqvist, J., Willy, C., Fagerdahl, A.-M., Fraccalvieri, M., Malmsjö, M., Piaggesi, A., Probst, A., & Vowden, P. (2017) · Journal of Wound Care · doi:10.12968/jowc.2017.26.sup3.s1 · Cited by 215
Garg, S. K., Potts, R. O., Ackerman, N. R., Fermi, S. J., Tamada, J. A., & Chase, H. P. (1999) · Diabetes Care · doi:10.2337/diacare.22.10.1708 · Cited by 201
Design, Development, and Evaluation of a Novel Microneedle Array-based Continuous Glucose Monitor
Jina, A., Tierney, M. J., Tamada, J. A., McGill, S., Desai, S., Chua, B., Chang, A., & Christiansen, M. (2014) · Journal of Diabetes Science and Technology · doi:10.1177/1932296814526191 · Cited by 176
Caffarel-Salvador, E., Brady, A. J., Eltayib, E., Meng, T., Alonso-Vicente, A., Gonzalez-Vazquez, P., Torrisi, B. M., Vicente-Perez, E. M., Mooney, K., Jones, D. S., et al. (2015) · PLOS ONE · doi:10.1371/journal.pone.0145644 · Cited by 174
Baker, M. (2005) · Nature Biotechnology · doi:10.1038/nbt0305-297 · Cited by 150
Agache, P. G., & Humbert, P. G. (2004) · Springer eBooks · doi:10.1007/978-3-662-08585-1 · Cited by 148
Bolincier, J., Ungerstedt, U., & Arner, P. (1992) · Diabetologia · doi:10.1007/bf00401374 · Cited by 142
Humbert, P. G., Maibach, H. I., Fanian, F., & Agache, P. G. (2011) · Medical Entomology and Zoology · Cited by 139
Microneedle-based sensors for medical diagnosis
Miller, P. R., Narayan, R. J., & Polsky, R. (2016) · Journal of Materials Chemistry B · doi:10.1039/c5tb02421h · Cited by 137
Drop-to-Drop Variation in the Cellular Components of Fingerprick Blood
Bond, M. M., & Richards‐Kortum, R. (2015) · American Journal of Clinical Pathology · doi:10.1309/ajcp1l7dkmpchpeh · Cited by 128
Collection of Analytes from Microneedle Patches
Romanyuk, A. V., Zvezdin, V., Samant, P. P., et al. (2014) · Analytical Chemistry · doi:10.1021/ac503823p · Cited by 124
Self-citationSieg, A., Guy, R. H., & Delgado-Charro, M. B. (2004) · Clinical Chemistry · doi:10.1373/clinchem.2004.032862 · Cited by 119
Suction blister fluid as potential body fluid for biomarker proteins
Kool, J., Reubsaet, L., Wesseldijk, F., Maravilha, R. T., Pinkse, M. W. H., D’Santos, C. S., van Hilten, J. J., Zijlstra, F. J., & Heck, A. J. R. (2007) · PROTEOMICS · doi:10.1002/pmic.200600938 · Cited by 118
Open Flow Microperfusion as a Dermal Pharmacokinetic Approach to Evaluate Topical Bioequivalence
Bodenlenz, M., Tiffner, K., Raml, R., Augustin, T., Dragatin, C., Birngruber, T., Schimek, D., Schwagerle, G., Pieber, T. R., Raney, S. G., et al. (2016) · Clinical Pharmacokinetics · doi:10.1007/s40262-016-0442-z · Cited by 104
Microdialysis methodology for the measurement of dermal interstitial fluid in humans
Krogstad, A., Jansson, P., GISSLÉN, P., & Lönnroth, P. (1996) · British Journal of Dermatology · doi:10.1046/j.1365-2133.1996.d01-893.x · Cited by 98
Microneedle-Mediated Minimally Invasive Patient Monitoring
Donnelly, R. F., Mooney, K. M., Caffarel–Salvador, E., Torrisi, B. M., Eltayib, E. M., & McElnay, J. C. (2013) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000000022 · Cited by 93
Matsui, T., Hayashi-Kisumi, F., Kinoshita, Y., Katahira-Tayama, S., Morita, K., Miyachi, Y., Ono, Y., Imai, T., Tanigawa, Y., Komiya, T., et al. (2004) · Genomics · doi:10.1016/j.ygeno.2004.03.010 · Cited by 86
Müller, A. C., Breitwieser, F. P., Fischer, H., Schuster, C., Brandt, O., Colinge, J., Superti‐Furga, G., Stingl, G., Elbe‐Bürger, A., & Bennett, K. L. (2012) · Journal of Proteome Research · doi:10.1021/pr3002035 · Cited by 86
Accuracy and Reliability of Continuous Glucose Monitoring Systems: A Head-to-Head Comparison
Luijf, Y. M., Mader, J. K., Doll, W., Pieber, T. R., Farret, A., Place, J., Renard, É., Bruttomesso, D., Filippi, A., Avogaro, A., et al. (2013) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2013.0049 · Cited by 82
Tumor interstitial fluid — A treasure trove of cancer biomarkers
Gromov, P., Gromova, I., Olsen, C. J., Wielenga, V. T., Talman, M.-L., Serizawa, R., & Moreira, J. M. A. (2013) · Biochimica et Biophysica Acta (BBA) - Proteins and Proteomics · doi:10.1016/j.bbapap.2013.01.013 · Cited by 78
Muller, D. A., Corrie, S. R., Coffey, J. W., Young, P. R., & Kendall, M. A. F. (2012) · Analytical Chemistry · doi:10.1021/ac2034387 · Cited by 75
Corrie, S. R., Fernando, G. J. P., Crichton, M. L., Brunck, M. E. G., Anderson, C. D., & Kendall, M. A. F. (2010) · Lab on a Chip · doi:10.1039/c0lc00068j · Cited by 74
Parikh, P., Greenberger, H. M., & Mosca, L. J. (2009) · American Journal of Health Promotion · doi:10.4278/ajhp.071221140 · Cited by 64
Peeling off the layers: Skin taping and a novel proteomics approach to study atopic dermatitis
Broccardo, C. J., Mahaffey, S. B., Strand, M. J., Reisdorph, N. A., & Leung, D. Y. M. (2009) · Journal of Allergy and Clinical Immunology · doi:10.1016/j.jaci.2009.07.057 · Cited by 61
Micropore closure kinetics are delayed following microneedle insertion in elderly subjects
Kelchen, M. N., Siefers, K., Converse, C. C., Farley, M. J., Holdren, G. O., & Brogden, N. K. (2016) · Journal of Controlled Release · doi:10.1016/j.jconrel.2016.01.051 · Cited by 47
Hollow Microneedle-based Sensor for Multiplexed Transdermal Electrochemical Sensing
Miller, P. R., Skoog, S. A., Edwards, T. L., Wheeler, D. R., Xiao, X., Brozik, S. M., Polsky, R., & Narayan, R. J. (2012) · Journal of Visualized Experiments · doi:10.3791/4067 · Cited by 36
Cited by
Wearable chemical sensors for biomarker discovery in the omics era
Sempionatto, J. R., Lasalde-Ramírez, J. A., Mahato, K., Wang, J., & Gao, W. (2022) · Nature Reviews Chemistry · doi:10.1038/s41570-022-00439-w · Cited by 613
Wearable Electrochemical Sensors for the Monitoring and Screening of Drugs
Teymourian, H., Parrilla, M., Sempionatto, J. R., Montiel, N. F., Barfidokht, A., Van Echelpoel, R., De Wael, K., & Wang, J. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01318 · Cited by 423
Hydrogel‐Forming Microneedles: Current Advancements and Future Trends
Turner, J. G., White, L. R., Estrela, P., & Leese, H. S. (2021) · Macromolecular Bioscience · doi:10.1002/mabi.202000307 · Cited by 413
Artificial intelligence biosensors: Challenges and prospects
Jin, X., Liu, C., Xu, T., Su, L., & Zhang, X. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112412 · Cited by 399
Microneedle patch for the ultrasensitive quantification of protein biomarkers in interstitial fluid
Wang, Z., Luan, J., Seth, A., Liu, L., You, M., Gupta, P., Rathi, P., Wang, Y., Cao, S., Jiang, Q., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00672-y · Cited by 386
Metadata
- Authors
- Samant, P. P., & Prausnitz, M. R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2018-04-16
- Volume
- 115
- Issue
- 18
- Pages
- 4583-4588
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2799391791
- Cited by
- 363
- References
- 40
- FWCI
- 12.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.