Mechanisms of sampling interstitial fluid from skin using a microneedle patch
Open accessThe DOI matches its Crossref record; 40 of the 40 references it cites were found in a registry or an index.
Abstract
Significance: Diagnosis and monitoring of disease is often done by measuring biomarkers found in blood, urine, saliva, and other bodily fluids. Another rich source of biomarkers is the interstitial fluid that surrounds cells and tissues in the body, but difficulty in accessing this fluid has limited its use in research and medicine. Here, we conducted experimental studies coupled with theoretical modeling to design a patch containing microscopic needles that puncture into superficial layers of skin and thereby enable withdrawal of interstitial fluid through micropores in a simple, minimally invasive manner. This patch can help researchers access interstitial fluid to advance discovery of novel biomarkers and enable doctors to use interstitial fluid for possible future diagnosis and monitoring of disease.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Chang, H., Zheng, M., Yu, X., Than, A., Seeni, R. Z., Kang, R., Tian, J., Khanh, D. P., Liu, L., Chen, P., et al. (2017) · Advanced Materials · doi:10.1002/adma.201702243 · Cited by 462
Suction Blister Device for Separation of Viable Epidermis from Dermis*
Kiistala, U. (1968) · Journal of Investigative Dermatology · doi:10.1038/jid.1968.15 · Cited by 448
Engineering Microneedle Patches for Vaccination and Drug Delivery to Skin
Prausnitz, M. R. (2017) · Annual Review of Chemical and Biomolecular Engineering · doi:10.1146/annurev-chembioeng-060816-101514 · Cited by 439
Self-citationSkin models for the testing of transdermal drugs
Abd, E., Yousuf, S., Pastore, M., Telaprolu, K., Mohammed, Y., Namjoshi, S., Grice, J., & Roberts, M. (2016) · Clinical Pharmacology: Advances and Applications · doi:10.2147/cpaa.s64788 · Cited by 413
Interstitial fluid volume: local regulatory mechanisms.
Aukland, K., & Nicolaysen, G. (1981) · Physiological Reviews · doi:10.1152/physrev.1981.61.3.556 · Cited by 402
Slupsky, C. M., Rankin, K. N., Wagner, J., Fu, H., Chang, D., Weljie, A. M., Saude, E. J., Lix, B., Adamko, D. J., Shah, S., et al. (2007) · Analytical Chemistry · doi:10.1021/ac0708588 · Cited by 401
Microneedle array for transdermal biological fluid extraction and in situ analysis
Mukerjee, E. V., Collins, S. D., Isseroff, R. R., & Smith, R. L. (2004) · Sensors and Actuators A: Physical · doi:10.1016/j.sna.2003.11.008 · Cited by 340
Clinical and diagnostic utility of saliva as a non-invasive diagnostic fluid: a systematic review
Soares Nunes, L. A., Mussavira, S., & Sukumaran Bindhu, O. (2015) · Biochemia Medica · doi:10.11613/bm.2015.018 · Cited by 333
Prausnitz, M. R., Mikszta, J. A., Cormier, M., & Andrianov, A. K. (2009) · Current Topics in Microbiology and Immunology · doi:10.1007/978-3-540-92165-3_18 · Cited by 314
Self-citationComposition of interstitial fluid
Fogh-Andersen, N., Altura, B. M., Altura, B. T., & Siggaard-Andersen, O. (1995) · Clinical Chemistry · doi:10.1093/clinchem/41.10.1522 · Cited by 309
Cited by
Wearable chemical sensors for biomarker discovery in the omics era
Sempionatto, J. R., Lasalde-Ramírez, J. A., Mahato, K., Wang, J., & Gao, W. (2022) · Nature Reviews Chemistry · doi:10.1038/s41570-022-00439-w · Cited by 613
Wearable Electrochemical Sensors for the Monitoring and Screening of Drugs
Teymourian, H., Parrilla, M., Sempionatto, J. R., Montiel, N. F., Barfidokht, A., Van Echelpoel, R., De Wael, K., & Wang, J. (2020) · ACS Sensors · doi:10.1021/acssensors.0c01318 · Cited by 423
Hydrogel‐Forming Microneedles: Current Advancements and Future Trends
Turner, J. G., White, L. R., Estrela, P., & Leese, H. S. (2021) · Macromolecular Bioscience · doi:10.1002/mabi.202000307 · Cited by 413
Artificial intelligence biosensors: Challenges and prospects
Jin, X., Liu, C., Xu, T., Su, L., & Zhang, X. (2020) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112412 · Cited by 399
Microneedle patch for the ultrasensitive quantification of protein biomarkers in interstitial fluid
Wang, Z., Luan, J., Seth, A., Liu, L., You, M., Gupta, P., Rathi, P., Wang, Y., Cao, S., Jiang, Q., et al. (2021) · Nature Biomedical Engineering · doi:10.1038/s41551-020-00672-y · Cited by 386
Sampling interstitial fluid from human skin using a microneedle patch
Samant, P. P., Niedzwiecki, M. M., Raviele, N., Tran, V., Mena-Lapaix, J., Walker, D. I., Felner, E. I., Jones, D. P., Miller, G. W., & Prausnitz, M. R. (2020) · Science Translational Medicine · doi:10.1126/scitranslmed.aaw0285 · Cited by 379
Self-citationOpportunities and challenges in the diagnostic utility of dermal interstitial fluid
Friedel, M., Thompson, I. A. P., Kasting, G., Polsky, R., Cunningham, D., Soh, H. T., & Heikenfeld, J. (2023) · Nature Biomedical Engineering · doi:10.1038/s41551-022-00998-9 · Cited by 360
Teymourian, H., Moonla, C., Tehrani, F., Vargas, E., Aghavali, R., Barfidokht, A., Tangkuaram, T., Mercier, P. P., Dassau, E., & Wang, J. (2020) · Analytical Chemistry · doi:10.1021/acs.analchem.9b05109 · Cited by 278
Wearable electrochemical biosensors in North America
Min, J., Sempionatto, J. R., Teymourian, H., Wang, J., & Gao, W. (2021) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2020.112750 · Cited by 278
Transdermal electroosmotic flow generated by a porous microneedle array patch
Kusama, S., Sato, K., Matsui, Y., Kimura, N., Abe, H., Yoshida, S., & Nishizawa, M. (2021) · Nature Communications · doi:10.1038/s41467-021-20948-4 · Cited by 260
Chen, Z., Li, H., Bian, Y., Wang, Z., Chen, G., Zhang, X., Miao, Y., Wen, D., Wang, J., Wan, G., et al. (2021) · Nature Nanotechnology · doi:10.1038/s41565-021-00910-7 · Cited by 256
Lin, S., Cheng, X., Zhu, J., Wang, B., Jelinek, D., Zhao, Y., Wu, T.-Y., Horrillo, A., Tan, J., Yeung, J., et al. (2022) · Science Advances · doi:10.1126/sciadv.abq4539 · Cited by 255
Encoded Microneedle Arrays for Detection of Skin Interstitial Fluid Biomarkers
Zhang, X., Chen, G., Bian, F., Cai, L., & Zhao, Y. (2019) · Advanced Materials · doi:10.1002/adma.201902825 · Cited by 252
Biomolecular sensors for advanced physiological monitoring
Flynn, C. D., Chang, D., Mahmud, A., Yousefi, H., Das, J., Riordan, K. T., Sargent, E. H., & Kelley, S. O. (2023) · Nature Reviews Bioengineering · doi:10.1038/s44222-023-00067-z · Cited by 226
Bioadhesive Technology Platforms
Wu, S. J., & Zhao, X. (2023) · Chemical Reviews · doi:10.1021/acs.chemrev.3c00380 · Cited by 218
Zhu, J., Zhou, X., Kim, H., Qu, M., Jiang, X., Lee, K., Ren, L., Wu, Q., Wang, C., Zhu, X., et al. (2020) · Small · doi:10.1002/smll.201905910 · Cited by 214
Li, Y., Zhang, H., Yang, R., Laffitte, Y., Schmill, U., Hu, W., Kaddoura, M., Blondeel, E. J. M., & Cui, B. (2019) · Microsystems & Nanoengineering · doi:10.1038/s41378-019-0077-y · Cited by 210
Skin in the diagnostics game: Wearable biosensor nano- and microsystems for medical diagnostics
Dervisevic, M., Alba, M., Prieto-Simon, B., & Voelcker, N. H. (2020) · Nano Today · doi:10.1016/j.nantod.2019.100828 · Cited by 203
Luan, J., Seth, A., Gupta, R., Wang, Z., Rathi, P., Cao, S., Gholami Derami, H., Tang, R., Xu, B., Achilefu, S., et al. (2020) · Nature Biomedical Engineering · doi:10.1038/s41551-020-0547-4 · Cited by 201
“53 Here, we employed p-FLISA to measure the concentrations of a proinflammation cytokine (IL-6) in skin interstitial fluid obtained from mice immune-stimulated with lipopolysaccharide (LPS) and naïve mice (as controls).”
Wearable Electrochemical Biosensors for Advanced Healthcare Monitoring
Duan, H., Peng, S., He, S., Tang, S., Goda, K., Wang, C. H., & Li, M. (2025) · Advanced Science · doi:10.1002/advs.202411433 · Cited by 195
Wu, Z., Qiao, Z., Chen, S., Fan, S., Liu, Y., Qi, J., & Lim, C. T. (2024) · Communications Materials · doi:10.1038/s43246-024-00468-6 · Cited by 183
A practical guide to the development of microneedle systems – In clinical trials or on the market
Lee, K. J., Jeong, S. S., Roh, D. H., Kim, D. Y., Choi, H.-K., & Lee, E. H. (2020) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2019.118778 · Cited by 173
Biosensing in dermal interstitial fluid using microneedle based electrochemical devices
Madden, J., O'Mahony, C., Thompson, M., O'Riordan, A., & Galvin, P. (2020) · Sensing and Bio-Sensing Research · doi:10.1016/j.sbsr.2020.100348 · Cited by 161
Finger sweat analysis enables short interval metabolic biomonitoring in humans
Brunmair, J., Gotsmy, M., Niederstaetter, L., Neuditschko, B., Bileck, A., Slany, A., Feuerstein, M. L., Langbauer, C., Janker, L., Zanghellini, J., et al. (2021) · Nature Communications · doi:10.1038/s41467-021-26245-4 · Cited by 96
Non-invasive monitoring of interstitial fluid lactate through an epidermal iontophoretic device
De la Paz, E., Saha, T., Del Caño, R., Seker, S., Kshirsagar, N., & Wang, J. (2023) · Talanta · doi:10.1016/j.talanta.2022.124122 · Cited by 63
“ISF collection has been performed earlier using both invasive and minimally invasive tools such as microdialysis catheters [2], or hollow microneedles [3,6].”
Standardization process of continuous glucose monitoring: Traceability and performance
Freckmann, G., Nichols, J. H., Hinzmann, R., Klonoff, D. C., Ju, Y., Diem, P., Makris, K., & Slingerland, R. J. (2021) · Clinica Chimica Acta · doi:10.1016/j.cca.2020.12.025 · Cited by 62
Wearable Microfluidics for Continuous Assay
Lin, P.-H., Nien, H.-H., & Li, B.-R. (2023) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-091322-082930 · Cited by 28
A microneedle device for rapid dermal interstitial fluid sampling
Hung, A. H., Kamat, N. U., Bermudez, A., Boczek, S. M., Garcia-Marqués, F. J., Tan, Y. L., Hwang, J. (., Sinawang, P. D., Ilyin, D., Jacobson, G. B., et al. (2025) · Science Advances · doi:10.1126/sciadv.adx5492 · Cited by 22
A Microneedle Device for Rapid Dermal Interstitial Fluid Sampling
Hung, A. H., Rajesh, N. U., Bermudez, A., Boczek, S. M., Garcia-Marqués, F. J., Tan, Y. L., Hwang, J. (., Sinawang, P. D., Ilyin, D., Jacobson, G. B., et al. (2025) · doi:10.1101/2025.03.13.641882 · Cited by 22
Microalgae Microneedle Supplies Oxygen for Antiphotoaging Treatment
Wang, Z., Kwong, C. H. T., Zhao, H., Ding, Y.-F., Gao, C., Zhang, D., Cheng, Q., Wei, J., Zhang, Q.-W., & Wang, R. (2023) · ACS Applied Bio Materials · doi:10.1021/acsabm.3c00192 · Cited by 19
Metadata
- Authors
- Samant, P. P., & Prausnitz, M. R.
- Venue
- Proceedings of the National Academy of Sciences
- Published
- 2018-04-16
- Volume
- 115
- Issue
- 18
- Pages
- 4583-4588
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- OpenAlex
- W2799391791
- Cited by
- 363
- References
- 40
- FWCI
- 12.00
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.