A flexible organic reflectance oximeter array
Open accessThe DOI matches its Crossref record; 38 of the 38 references it cites were found in a registry or an index.
Abstract
Significance: The optical method to determine oxygen saturation in blood is limited to only tissues that can be transilluminated. The status quo provides a single-point measurement and lacks 2D oxygenation mapping capability. We use organic printed optoelectronics in a flexible array configuration that senses reflected light from tissue. Our reflectance oximeter is used beyond conventional sensing locations and accurately measures oxygen saturation on the forehead. In a full system implementation, coupled with a mathematical model, we create 2D oxygenation maps of adult forearms under pressure-cuff–induced ischemia. Our skin-like flexible sensor system has the potential to transform oxygenation monitoring of tissues, wounds, skin grafts, and transplanted organs.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Figures





Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
The source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“A racial discrepancy has been established in pulse oximeters, which rely on transmission PPG, a slightly different form of the technology.”
From Accuracy of heart rate measurement with wrist-worn wearable devices in various skin tones: a systematic review (2023) · cites this paper as [5]
Experimental — accuracy not yet measuredThe source backs part of the claim, not all of it — or backs it for a different population, condition or comparison.
In the citing paper
“The first presented device (Figure 1c) is an ultra-thin flexible oximeter array with silicon-integrated circuits that can monitor a pulsatile arterial blood signal [14].”
From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [14]
Experimental — accuracy not yet measuredThe cited source says what the claim attributes to it.
In the citing paper
“PPG uses optical differences between the vascular and other tissues or oxygenated and deoxygenated hemoglobin to measure heart rate,[263] blood oxygen,[267] and other in-depth cardiovascular information.[268]”
From Flexible Electronics and Devices as Human–Machine Interfaces for Medical Robotics (2022) · cites this paper as [267]
In the citing paper
“Instead of photodetectors measuring reflected light, they measure LED light that shines through the tissue to the opposite side, restricting it to locations that can be transilluminated, such as the earlobes and fingers [5].”
From Accuracy of heart rate measurement with wrist-worn wearable devices in various skin tones: a systematic review (2023) · cites this paper as [5]
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fully integrated wearable sensor arrays for multiplexed in situ perspiration analysis
Gao, W., Emaminejad, S., Nyein, H. Y. Y., Challa, S., Chen, K., Peck, A., Fahad, H. M., Ota, H., Shiraki, H., Kiriya, D., et al. (2016) · Nature · doi:10.1038/nature16521 · Cited by 5,087
Trung, T. Q., & Lee, N. (2016) · Advanced Materials · doi:10.1002/adma.201504244 · Cited by 2,160
The rise of plastic bioelectronics
Someya, T., Bao, Z., & Malliaras, G. G. (2016) · Nature · doi:10.1038/nature21004 · Cited by 1,884 · cited 2×
“(A) Three layers of optoelectronics - (1) OPD array layer, (2) NIR OLED array layer, and (3) Red OLED array layer are fabricated on separate substrates.”
BackgroundRecent Advances in Flexible and Stretchable Bio‐Electronic Devices Integrated with Nanomaterials
Choi, S., Lee, H., Ghaffari, R., Hyeon, T., & Kim, D. (2016) · Advanced Materials · doi:10.1002/adma.201504150 · Cited by 1,104 · cited 1×
“(B) Similar to A, stationary (dc) signal magnitude for red (4) and NIR ( ) channels.”
BackgroundUltraflexible organic photonic skin
Yokota, T., Zalar, P., Kaltenbrunner, M., Jinno, H., Matsuhisa, N., Kitanosako, H., Tachibana, Y., Yukita, W., Koizumi, M., & Someya, T. (2016) · Science Advances · doi:10.1126/sciadv.1501856 · Cited by 1,024 · cited 1×
“(13) demonstrated SpO 2 on the fingertips using an ultraflexible photonic skin.”
BackgroundA skin-inspired organic digital mechanoreceptor
Tee, B. C.-K., Chortos, A., Berndt, A., Nguyen, A. K., Tom, A., McGuire, A., Lin, Z. C., Tien, K., Bae, W.-G., Wang, H., et al. (2015) · Science · doi:10.1126/science.aaa9306 · Cited by 882
All-organic optoelectronic sensor for pulse oximetry
Lochner, C. M., Khan, Y., Pierre, A., & Arias, A. C. (2014) · Nature Communications · doi:10.1038/ncomms6745 · Cited by 726 · cited 1×
“(17) demonstrated SpO t 2 on the finger using an all-organic optoelectronic sensor.”
MethodSelf-citationWound healing essentials: Let there be oxygen
Sen, C. K. (2009) · Wound Repair and Regeneration · doi:10.1111/j.1524-475x.2008.00436.x · Cited by 713
Graphene Electronic Tattoo Sensors
Kabiri Ameri, S., Ho, R., Jang, H., Tao, L., Wang, Y., Wang, L., Schnyer, D. M., Akinwande, D., & Lu, N. (2017) · ACS Nano · doi:10.1021/acsnano.7b02182 · Cited by 669
Duncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Tyszczuk, L., Cope, M., & Delpy, D. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/2/007 · Cited by 649 · cited 2×
“5, the molar extinction coefficients and DPF (λ) can be obtained from the literature (1, 24).”
MethodResult
Cited by
Items 201–300 of 304
Wearable health monitoring system based on self-powered Bi-based perovskite photodetector
Ren, H., Li, Y., Chen, Y., Wei, R., Kuang, D., Wei, Z., & Shen, G. (2026) · Nano Energy · doi:10.1016/j.nanoen.2026.111835 · Cited by 8
Yoshida, A., Méhes, G., Okuyama, Y., Murakata, M., Shiba, T., & Tokito, S. (2023) · Advanced Electronic Materials · doi:10.1002/aelm.202300615 · Cited by 8
Effects of Deuterium Isotopes on Pt(II) Complexes and Their Impact on Organic NIR Emitters
Wang, S., Zhou, D., Kuo, K., Wang, C., Hung, C., Yan, J., Liao, L., Hung, W., Chi, Y., & Chou, P. (2024) · Angewandte Chemie · doi:10.1002/ange.202317571 · Cited by 8
Troughton, J. G., Brige, P., & Ramuz, M. P. (2023) · Biomedical Materials & Devices · doi:10.1007/s44174-022-00057-6 · Cited by 8
“While no previous work has looked at the use of reflectance measurements solely on a blood vessel, several studies have reported reflectance oximetry measurements both externally and subcutaneously [11, 43, 70–73].”
Detection of fluorescence-labeled DNA with in-plane organic optoelectronic devices
Titov, I., Rutschke, N., Kraft, F. A., Köpke, M., Nebling, E., & Gerken, M. (2022) · Biomedical Optics Express · doi:10.1364/boe.475358 · Cited by 8
Khan, Y., Mauriello, M. L., Nowruzi, P., Motani, A., Hon, G., Vitale, N. H., Li, J., Kim, J., Foudeh, A. M., Duvio, D., et al. (2021) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2021.01.20.427496 · Cited by 8
Self-citationMultifunctional Wearable OLED−OPD System with Wavelength-Tunable Emission for Phototheranostics
Park, M., Lee, H. S., Cho, Y., Jeong, J., Lee, C., Jeong, S. Y., Kwon, S. J., Cho, E., & Jeon, Y. (2026) · ACS Sensors · doi:10.1021/acssensors.5c04796 · Cited by 7
Flexible Optical Tactile Force Sensor to Conduct Measurements From the Back of the Hand
Ando, K., Kushihashi, M., Kawaguchi, H., & Izumi, S. (2025) · IEEE Sensors Journal · doi:10.1109/jsen.2025.3545137 · Cited by 7
“Our proposed optical measurement method shares similarities with the configurations utilized in photoplethysmogra-phy (PPG) and oxygen saturation (SpO2) measurement [20], [21], [22], [23], [24], [25], [26].”
Chung, K., Pandey, A., Sarwar, T., Aiello, A. F., Mi, Z., Bhattacharya, P., & Ku, P.-C. (2020) · Applied Physics Letters · doi:10.1063/1.5140996 · Cited by 7
Kornikov, A. I., Kozlov, M. I., Vashchenko, A. A., Pavlov, A. A., Gordeeva, E. O., Latipov, E. V., Lepnev, L. S., Kozhevnikova, V. Y., & Utochnikova, V. V. (2023) · ACS Applied Optical Materials · doi:10.1021/acsaom.3c00124 · Cited by 7
Organic Electronics—Microfluidics/Lab on a Chip Integration in Analytical Applications
Shinar, R., & Shinar, J. (2023) · Sensors · doi:10.3390/s23208488 · Cited by 8
Narrow Band Organic Photodiode with Photoresponse at 808 nm for Photoplethysmography
Saggar, S., Shukla, A., Lo, S., & Namdas, E. B. (2024) · Advanced Photonics Research · doi:10.1002/adpr.202400003 · Cited by 7
Accuracy enhancement in reflective pulse oximetry by considering wavelength-dependent pathlengths
Badiola, I., Blažek, V., Kumar, V. J., George, B., Leonhardt, S. K., & Antink, C. H. (2022) · Physiological Measurement · doi:10.1088/1361-6579/ac890c · Cited by 7
Flexible photoplethysmographic sensing devices for intelligent medical treatment
Wu, W., Wang, L., & Shen, G. (2023) · Journal of Materials Chemistry C · doi:10.1039/d2tc03318f · Cited by 7
Stretchable Textile Bands for Ambulatory Electrocardiogram and Oximetry
Liu, J., Le, T., Sadatian, E., Yao, L., Garudadri, H., Dunphy, S. A., McClung, C., & Ng, T. N. (2022) · IEEE Journal on Flexible Electronics · doi:10.1109/jflex.2022.3220138 · Cited by 7
“The oxygen saturation level SO2 has been shown to be correlated with R in previous works [25], [26], and the relationship of R and SO2 was calibrated by using an altitude simulator (AltoLab BOOST) to vary the blood oxygen level Fig.”
BackgroundMethodLai, H., Zhu, Y., Shan, C., Luo, Y., Lai, X., Gu, Y., Xiong, S., Ou, M., Deng, Z., Shen, X., et al. (2025) · Angewandte Chemie International Edition · doi:10.1002/anie.202519630 · Cited by 6
Cho, E. H., An, J., Chi, Y., & Choi, K. C. (2026) · Nature Communications · doi:10.1038/s41467-025-68258-3 · Cited by 6
Nagarajan, R. D., & Sundramoorthy, A. K. (2021) · Springer eBooks · doi:10.1007/978-3-030-55490-3_18 · Cited by 6
Inkjet‐Printed Microlenses Integrated onto Organic Photodiodes for Highly Accurate Proximity Sensing
Seiberlich, M., Zhang, Q., Tunç, A. V., Xia, K., Ruiz‐Preciado, L. A., Schlisske, S., Falis, K., Strobel, N., Lemmer, U., & Hernandez‐Sosa, G. (2023) · Advanced Sensor Research · doi:10.1002/adsr.202300004 · Cited by 6
Li, H., Yuan, J., Fennell, G., Abdulla, V., Nistala, R., Dandachi, D., Ho, K. C., & Zhang, Y. (2023) · Biophysics Reviews · doi:10.1063/5.0140900 · Cited by 6
Tang, R., Yao, X., Chen, J., Sridar, S., He, X., Pu, Y., Wang, J., Wang, D., & Wang, S. (2021) · Macromolecular Rapid Communications · doi:10.1002/marc.202100134 · Cited by 5
Streamlined Inkjet‐Printing of Stretchable Organic Photodetectors
Seiberlich, M., Rainer, C., Skarjan, L., Ruiz‐Preciado, L. A., Perevedentsev, A., Xia, K., Krebsbach, P., Schlisske, S., Lemmer, U., & Hernandez‐Sosa, G. (2025) · Advanced Materials Technologies · doi:10.1002/admt.202401413 · Cited by 5
Organic Electronics and Their Applications as Sensors
Raj, R., Singh, K. R., Verma, R., Singh, J., & Singh, R. P. (2023) · Wiley eBooks · doi:10.1002/9783527834266.ch15 · Cited by 5
Artificial Visual Electronics for Closed‐Loop Sensation/Action Systems
Jiang, Z., Jiang, Y., Chen, N., & Chen, X. (2021) · Advanced Intelligent Systems · doi:10.1002/aisy.202100071 · Cited by 5
Gong, W., Yue, Z., Luo, Z., Wang, C., Zhu, Z., Ni, Z., & Xiang, N. (2026) · ACS Sensors · doi:10.1021/acssensors.6c00786 · Cited by 4
Multi-modal Wearable Patch for Localized Monitoring of Post-operative Skin Flap Transplantation
Luo, J., Zhao, Y., Xu, Y. Y., Shen, Y., Jiang, Y., Chai, W. S., Liu, G., Wei, P., Li, H., Duan, K., et al. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c20682 · Cited by 4
Yamamoto, S., & Kai, H. (2022) · Advanced Materials Interfaces · doi:10.1002/admi.202201736 · Cited by 4
Jia, Y., & Zhang, K. (2023) · Journal of Materials Chemistry C · doi:10.1039/d3tc03612j · Cited by 4
Ji, Q., Chen, Y., Xu, W., Zou, Z., Fan, H., Chen, Z., Tao, L., & Li, X. (2024) · APL Photonics · doi:10.1063/5.0174347 · Cited by 4
Kuchoor, H., Deshmukh, Y., Baruah, R., Li, J., Winkler, C. R., Reynolds, L., & Iyer, S. N. (2024) · ACS Applied Nano Materials · doi:10.1021/acsanm.4c01241 · Cited by 4
A Low-Power PPG Readout With an Automatic Switching Between Ambient Light and OLED Driver
Pandey, R. K., Pribadi, E. F., & Chao, P. C.-P. (2024) · IEEE Sensors Journal · doi:10.1109/jsen.2024.3462890 · Cited by 4
Zhang, C., Liu, J., He, D., Xu, K., Fang, Y., Sun, W., & Xiong, W. (2025) · Journal of Organometallic Chemistry · doi:10.1016/j.jorganchem.2025.123613 · Cited by 3
Kanetani, I., Gon, M., & Tanaka, K. (2025) · Macromolecules · doi:10.1021/acs.macromol.5c01319 · Cited by 3
Brunetta, M., Qiao, Z., Nodari, D., Sasaki, K., Furlan, F., Rimmele, M., Kim, H. W., Chen, H., Tagawa, Y., Marsh, A. V., et al. (2026) · Advanced Energy Materials · doi:10.1002/aenm.202506776 · Cited by 3
“The SpO 2 of 97% was calculated according to the equation below: where R is the ratio of AC to DC at two different wavelengths (in our case at 780 nm and 940 nm), ε HbO 2 and ε Hb are the absorption coefficients of oxyhemoglobin and deoxyhemoglobin, extracted from [52].”
A wireless reader for detecting frequency shift of passive sensors
Mirlou, F., Bardakçı, E., Abbasiasl, T., & Beker, L. (2025) · Biosensors and Bioelectronics X · doi:10.1016/j.biosx.2025.100668 · Cited by 3
Progress in physiological textile sensors for biomedical applications
Shuvo, I. I., & Dolez, P. I. (2023) · Elsevier eBooks · doi:10.1016/b978-0-323-91593-9.00002-x · Cited by 3
Wang, K., Ying, W. B., Hu, H., Kong, Z., Li, F., Tian, Y., Chen, C., & Zhang, R. (2020) · ACS Applied Polymer Materials · doi:10.1021/acsapm.0c00644 · Cited by 3
Impact of Sensor Networks towards Individuals Augmenting Causes of Diabetes
Miah, M. R., Khan, M. S., Rahman, A. S., Samdany, A. A., Hannan, M. A., Chowdhury, S. H., & Sayok, A. K. (2020) · Cited by 3
Ultrathin Optics-Free Spectrometer with Monolithically Integrated LED Excitation
Sarwar, T., & Ku, P.-C. (2022) · Micromachines · doi:10.3390/mi13030382 · Cited by 3
BWatch: A Non-invasive Blood Leakage Detection Device using Robust Reflectance-based Sensing
Tan, C. H., Khaw, J.-Y., Wong, Y. C., Chionh, C. Y., & Foong, S. (2019) · IEEE Conference on Cybernetics and Intelligent Systems · doi:10.1109/cis-ram47153.2019.9095847 · Cited by 3
“tion difference between oxygenated haemoglobin (HbO2) and deoxygenated haemoglobin (Hb) in blood at multiple spectral regions, such as green, red and infrared (IR) region are used to estimate oxygen saturation level [4][5][6][7].”
BackgroundMethodInfluentialGap width modification on fully screen-printed coplanar Zn|MnO2 batteries
Rassek, P., Steiner, E. H., Herrenbauer, M., & Claypole, T. C. (2020) · Flexible and Printed Electronics · doi:10.1088/2058-8585/abaaa0 · Cited by 3
Ultra‐Flexible Dual‐Band Organic Photodetectors for Visible and Near‐Infrared Sensing
Awakura, S., Jinno, H., Tagawa, Y., Fukuzawa, R., Takakuwa, M., Someya, T., & Yokota, T. (2026) · Advanced Optical Materials · doi:10.1002/adom.202503746 · Cited by 2
Peng, Z., Lei, L., Zhen, H., Chen, R., Deng, S., Yang, C. R., Han, Y., & Liu, J. (2026) · Matter · doi:10.1016/j.matt.2026.102864 · Cited by 2
Wearable skin integrated flexible PVA ‐nickel nanocomposite patch for temperature sensor
Gudadur, K. S., Kumar, A., & Veluswamy, P. (2024) · Polymers for Advanced Technologies · doi:10.1002/pat.6477 · Cited by 2
Sasaki, K., Okuda, C., Wijaya, T. J., Lee, S., Yamagishi, K., Someya, T., & Yokota, T. (2025) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.4c15572 · Cited by 2
Research progress in flexible wearable sensing and intelligent recognition techniques
Wan, C., Wu, Z., & Huang, X. L. (2022) · Scientia Sinica Chimica · doi:10.1360/ssc-2022-0164 · Cited by 2
Hybrid liquid-metal heat dissipation structure enabled by phase transition for flexible electronics
Li, H., Zhang, H., Min, S., Zhou, T., Gong, S., Feng, X., & Ma, Z. (2021) · Semiconductor Science and Technology · doi:10.1088/1361-6641/abed8c · Cited by 2
FootAssure: A multimodal, in-home wound detection device for diabetic peripheral neuropathy
Khanal, N., Fadil, R., Gorji, H. T., Liang, B., Vasefi, F., MacKinnon, N. B., Akhbardeh, A., & Tavakolian, K. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9630275 · Cited by 2
Towards Wireless Flexible Printed Wearable Sensors
Baumbauer, C., Ting, J., Thielens, A., Rabaey, J. M., & Arias, A. C. (2019) · International Workshop on Advances in Sensors and Interfaces (IWASI) · doi:10.1109/iwasi.2019.8791367 · Cited by 2
Self-citation3D Printed Flexible Photoplethysmography Sensor Array for Tissue Oximetry
Petreikis, M., & Tiwari, M. K. (2022) · IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS) · doi:10.1109/fleps53764.2022.9781543 · Cited by 2
Valenti, S., Volpes, G., Parisi, A., Pernice, R., Stivala, S. S., Faes, L., & Busacca, A. (2022) · IEEE International Symposium on Medical Measurements and Applications (MeMeA) · doi:10.1109/memea54994.2022.9856478 · Cited by 2
Application of Organic Photodetectors (OPD) in Photoplethysmography (PPG) Sensors: A small review
Jhuma, F. A., & Hattori, R. (2022) · Proceedings of International Exchange and Innovation Conference on Engineering & Sciences (IEICES) · doi:10.5109/5909099 · Cited by 2
Reddy, J. W., Lassiter, M. M., Venkateswaran, R., & Chamanar, M. (2019) · International Conference on Solid-State Sensors, Actuators and Microsystems · doi:10.1109/transducers.2019.8808541 · Cited by 1
“From flexible chip-to-chip interconnects to wearable devices, flexible photonic platforms are emerging to fill new niches that are not well-addressed by rigid materials [1]–[3].”
BackgroundDesign and development of a photoplethysmography based microsystem for mental stress estimation
Pandey, R. K., & Chao, P. C.-P. (2022) · Microsystem Technologies · doi:10.1007/s00542-022-05295-8 · Cited by 1
“Most of them either employed electrocardiogram (ECG) and/or photoplethysmography (PPG) sensors (Kim et al. 2018, Martina et al. 2012, Forouzanfar et al. 2013, Huang et al. 2014, Cohen et al. 2017, Sommermeyer et al. 2016, Zheng et al. 2014, Khan et al. 2018, Pandey et al. 2020, 2021).”
BackgroundMethodRecent Advances in Organic Photodetectors with Biomedical Applications
Jiménez, M. Á.-P., Herrera‐May, A. L., Delgado‐Alvarado, E., Nolasco, J. C., Mabil-Espinosa, P., Mendoza-Barrón, G., Alarcón, Y. K., Tello-Fomperosa, C., & Martínez-Castillo, J. (2024) · IEEE International Conference on Engineering Veracruz (ICEV) · doi:10.1109/icev63254.2024.10766037 · Cited by 1
“The aperture that can easily pass through the skin and stretch out the subcutaneous vessels is between 600-1300nm a wide variety of flexible and stretchable optoelectronic sensors have been reported for PPG and wearable and adjustable therapeutic registering applications [41][42][43].”
Kornikov, A. I., Kozlov, M. I., Vashchenko, A. A., Poyarkov, A. A., Goloveshkin, A. S., Latipov, E. V., Lepnev, L. S., & Utochnikova, V. V. (2025) · ChemMedChem · doi:10.1002/cmdc.202500465 · Cited by 1
Brebels, S., Puttock, E. V., Cardeynaels, T., Bareikaite, K., Weatherill, L., Landeghem, M. V., Penxten, H., Danos, A., Vandewal, K., Monkman, A. P., et al. (2025) · ACS Applied Optical Materials · doi:10.1021/acsaom.5c00340 · Cited by 1
80‐1: Sensor OLED Display‐Based Mobile Cardiovascular Health Monitor
Kim, C., Yang, D., Moon, G., Kim, G., Kim, Y., & Lee, C. (2025) · SID Symposium Digest of Technical Papers · doi:10.1002/sdtp.18365 · Cited by 1
Kim, D. G., Park, M., Kim, Y., Cho, E., Jeon, Y., & Kwon, S. J. (2026) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.5c19764 · Cited by 1
Miranda-Vega, J. E., Ayala-Figueroa, R. I., González, Y. V., & Zepeda, P. A. E. (2026) · Sensors · doi:10.3390/s26082487 · Cited by 1
“Some oximeters that use near-infrared (NIR) LEDs, including wavelengths of 880 nm and 940 nm, exhibit similar ratios of the molar extinction coefficients of Hemoglobin (Hb) and Oxyhemoglobin (HbO 2 ) [17].”
Ilmi, R., Anjum, S., Raithby, P. R., & Khan, M. S. (2026) · Coordination Chemistry Reviews · doi:10.1016/j.ccr.2026.217952 · Cited by 1
Kim, J. H., Yoon, S. J., Lee, S. Y., Cho, C., Joe, D. J., Kim, S., Lee, Y., Lee, T., & Lee, H. E. (2026) · eScience · doi:10.1016/j.esci.2026.100634 · Cited by 1
Koseeyaporn, J., Sinchai, S., & Wardkein, P. (2019) · International Conference on Computer and Communication Systems (ICCCS) · doi:10.1109/ccoms.2019.8821770 · Cited by 1
“To express each PPG signal in a mathematical model, an approximated light intensity absorption of Beer-Lambert's law [10][11] is utilized.”
MethodRassek, P., Steiner, E. H., Claypole, T. C., Krebs, M., & Herrenbauer, M. (2020) · Applied Physics A · doi:10.1007/s00339-020-03785-y · Cited by 1
Multiplexed Biochemical and Biophysical Sensing Systems for Monitoring Human Physiology.
Yokus, M. A. (2020) · NCSU Libraries Repository (North Carolina State University Libraries) · Cited by 1
Monolithic Integrated OLED–OPD Unit for Point-of-Need Nitrate Sensing
Titov, I., Köpke, M., & Gerken, M. (2022) · Optical Sensors and Sensing Congress · doi:10.1364/es.2022.ew1g.1 · Cited by 1
Kang, H., Kim, H., Choi, A., Yun, Y., & Lee, G. H. (2023) · Crystals · doi:10.3390/cryst13101454 · Cited by 1
Takeshita, T., Yoshida, M., Kobayashi, T., & Takei, Y. (2024) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2024.115259 · Cited by 1
Steger, C., Tunç, A. V., Rainer, C., Karakaya, O., Mager, D., Ruiz‐Preciado, L. A., Joubert, T.-H., Lemmer, U., & Hernandez‐Sosa, G. (2025) · doi:10.3390/engproc2025109018 · Cited by 1
“One of the cornerstones of modern organic-based technology is light detection, used in state-of-the-art optical communication [1–3], imaging and medical sensing systems [4–6] and advanced flexible display technology [7–9].”
Medidas ópticas não invasivas de tempo de resposta da perfusão sanguínea
de Souza, R. P. (2020) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.59.2020.tde-22072020-165223 · Cited by 1
Shi, L., Li, N., Ji, T., Zhang, Y., Wang, W., Feng, L., Wen, R., Hao, Y., Wang, K., Zhu, F., et al. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2110.12839 · Cited by 1
Sotory, P. (2020) · NCSU Libraries Repository (North Carolina State University Libraries)
Refractive Index Measurement with a Flexible OLED-OPD Detection Unit
Titov, I., Köpke, M., & Gerken, M. (2020) · IEEE International Conference on Flexible and Printable Sensors and Systems (FLEPS) · doi:10.1109/fleps49123.2020.9239472
“proposed a flexible reflectance oximeter array, which was fabricated on separate substrates and assembled for sensing reflected light from tissue to determine oxygen saturation [6].”
Background70‐2: Sheet‐type Image Sensor with Near Infrared Sensitive Organic Photodiode
Yokota, T., Nakamura, T., Kato, H., Himoto, K., Kimura, H., Takimoto, A., & Someya, T. (2021) · SID Symposium Digest of Technical Papers · doi:10.1002/sdtp.14870
Lu, Y., & Guo, W. (2021) · Faculty Opinions – Post-Publication Peer Review of the Biomedical Literature · doi:10.3410/f.739247947.793582503
Lüder, H., Buhl, J., & Gerken, M. (2022) · Physics and simulation of optoelectronic devices. Conference · doi:10.1117/12.2606225
Xue, J., Xu, J., Ren, J., Liang, Q., Ou, Q., Wang, R., Shuai, Z., & Qiao, J. (2021) · ChemRxiv · doi:10.26434/chemrxiv.14330591
Mechanical Properties of Organic Light Emitting Diodes
Anye, V. C., Ngasoh, O. F., Stanislas, T. T., Akudago, A. F., Fru, J. N., & Adeniji, S. A. (2022) · Elsevier eBooks · doi:10.1016/b978-0-12-822944-6.00053-0
50‐1: Invited Paper: Flexible Imager with Organic Photodetector for Sensing Applications
Yokota, T., Dongkai, C., Wang, H., & Someya, T. (2024) · SID Symposium Digest of Technical Papers · doi:10.1002/sdtp.17615
Soft Sensors for Disease Diagnosis
Hu, H., Su, Y., & Nan, K. (2025) · Wiley eBooks · doi:10.1002/9783527845507.ch3
Integrating ML Approaches for Photodetectors
Bhattacharya, S., Ghosh, S., Deb, D., Hiremath, P., & Nath, D. (2025) · Progress in optical science and photonics · doi:10.1007/978-981-95-1687-2_9
Lai, H., Zhu, Y., Shan, C., Luo, Y., Lai, X., Gu, Y., Xiong, S., Ou, M., Deng, Z., Shen, X., et al. (2025) · Angewandte Chemie · doi:10.1002/ange.202519630
PTQ10 ‐based organic photodetectors for visible light detection and their tolerance to impurities
Dindault, C., Roche, G. H., Leyney, M., Jousselin‐Oba, T., Vignau, L., Chambon, S., Bonnardel, P., Taillemite, S., Wantz, G., & Hirsch, L. (2025) · Polymer International · doi:10.1002/pi.70053
Xu, X., You, J., Shahiduzzaman, M., Taima, T., & Iiyama, K. (2025) · Optical Review · doi:10.1007/s10043-025-01016-4
Printed electronics for body-worn RFID sensor
Zhou, R. (2023) · Kent Academic Repository (University of Kent) · doi:10.22024/unikent/01.02.102887
Eco-friendly and Scalable Fabrication of Organic Optoelectronic Sensors
Jan, J. (2024) · eScholarship (California Digital Library)
ジアマ, フ. ア. (2025) · Institutional Repositories DataBase (IRDB)
Fahed, S. (2019) · Institutional Repositories DataBase (IRDB) · doi:10.15017/2534467
深赤色及び近赤外発光有機材料の開発と有機EL素子及び連続発振有機半導体レーザーへの応用
YE, H. (2019) · Institutional Repositories DataBase (IRDB)
Misran, M. A. B. (2023) · Institutional Repositories DataBase (IRDB)
Chen, X., Shi, A., Bai, K., Li, Y. X., Lu, Q., & Lu, F. (2026) · Laser & Photonics Review · doi:10.1002/lpor.71237
Jiang, Y., Zhou, Y., Guo, X. S., Wang, Y., Cheng, W. M., Shi, Y., & Pan, L. (2026) · Advanced Functional Materials · doi:10.1002/adfm.202600027 · Cited by 1
“Such structural [56, 193, 194] QD photodetectors High Moderate Moderate–high Moderate Low Low–moderate [192, 196] Perovskite photodetectors”
InfluentialStretchable Organic Photodetectors: From Structural to Intrinsic Design
Kang, H. (2026) · Journal of Flexible and Printed Electronics · doi:10.56767/jfpe.260001
Flexible Photonic Devices for Implantable and Wearable Therapeutics
Chamkouri, H. (2026) · Laser & Photonics Review · doi:10.1002/lpor.71492
“…signals notably reflectance pulse oximetry and co-located photodiode backscatter provide sub-second feedback on local tissue oxygenation and delivered irradiance, enabling immediate emitter modulation to maintain therapeutic set points and detect coupling loss or hotspots [ 126, 129, 133, 394 ].”
Sharma, S., Awakura, S., Aoki, Y., Du, B., Wijaya, T. J., Yokota, T., & Someya, T. (2026) · npj Flexible Electronics · doi:10.1038/s41528-026-00628-3
n-Type Conjugated Polymers: Molecular Design, Material Properties, and Device Applications
Zhang, Y., Rong, M., Cao, X., Deng, S., Peng, Z., & Liu, J. (2026) · Chemical Reviews · doi:10.1021/acs.chemrev.5c00891
Kumar, A., Bhargav, K., Azamovich, K. B., Hazzazi, F., Malik, I., Ahmad, A., Nisar, K. S., & Tabish, M. (2026) · Sustainable materials and technologies · doi:10.1016/j.susmat.2026.e02288
From organic photodetectors to monolithic skin-conformal photoplethysmography systems
Kim, J.-H., Chae, S., Yokota, T., Sun, L., Jeong, J., Lee, S., Lee, J., Lee, J., Heo, J. H., Lee, S., et al. (2026) · Materials Science and Engineering R Reports · doi:10.1016/j.mser.2026.101313
Textile-Based Nanogenerators for Home-Based Monitoring of Cardiovascular Diseases
Yuan, X., Luo, J., Zhao, Y., Yan, Z., Zhi, J., Shi, Y., Wang, D., & Qin, Y. (2026) · Nanoenergy Advances · doi:10.3390/nanoenergyadv6040034
Metadata
- Authors
- Khan, Y., Han, D., Pierre, A., Ting, J., Wang, X., Lochner, C. M., Bovo, G., Yaacobi-Gross, N., Newsome, C., Wilson, R., & Arias, A. C.
- Affiliations
- University of California, Berkeley (US)
- Cambridge Display Technology (United Kingdom) (GB)
- Cambridge Display Technology Limited, Godmanchester, Cambridgeshire, PE29 2XG, United Kingdom
- Corresponding author
- Khan, Yasser
- Arias, Ana C.
- Venue
- Proceedings of the National Academy of Sciences
- Publisher
- National Academy of Sciences
- Published
- 2018-11-07
- Volume
- 115
- Issue
- 47
- Pages
- E11015-E11024
- ISSN
- 0027-8424 (ISSN-L)
- 1091-6490
- PMC
- PMC6255203
- OpenAlex
- W2899609120
- Cited by
- 278
- References
- 38
- Citations by year
- 2026: 18 · 2025: 29 · 2024: 33 · 2023: 38 · 2022: 44 · 2021: 52 · 2020: 39 · 2019: 25
- FWCI
- 11.59
- Type
- journal article
- Language
- en
- Open access
- hybrid
- doi.org
- Licence
- Locations
- Proceedings of the National Academy of Sciences (publishedVersion, cc-by-nc-nd)
- Europe PMC (PubMed Central) (publishedVersion, cc-by-nc-nd)
- PubMed Central (publishedVersion, cc-by-nc-nd)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion)
- eScholarship (California Digital Library) (submittedVersion, cc-by-nc-nd)
- Funders
- Intel Corporation (Semiconductor Research Corporation Grant No. 2014-IN-2571)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Chemistry › Analytical Chemistry › Analytical Chemistry and Sensors
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Keywords
- pulse oximetry, organic light-emitting diodes, organic photodiodes, flexible sensors, oxygen saturation, ischemia, arterial pulsation, tissue oxygenation
- MeSH terms
- Adult, Equipment Design, Forearm, Forehead, Humans, Ischemia, Models, Theoretical, Oximetry, Oxygen, Oxyhemoglobins
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.