The DOI matches its Crossref record; 23 of the 23 references it cites were found in a registry or an index.
Principles of Electrospray Ionization
Open accessAbstract
Electrospray ionization is today the most widely used ionization technique in chemical and biochemical analysis. Interfaced with a mass spectrometer it allows the investigation of the molecular composition of liquid samples. With electrospray a large variety of chemical substances can be ionized. There is no limitation in mass which thus enables even the investigation of large noncovalent protein complexes. Its high ionization efficiency profoundly changed biomolecular sciences because proteins can be identified and quantified on trace amounts in a high throughput fashion. This review article focuses mainly on the exploration of the underlying ionization mechanism. Some ionization characteristics are discussed that are related to this mechanism. Typical spectra of peptides, proteins, and noncovalent complexes are shown and the quantitative character of spectra is highlighted. Finally the possibilities and limitations in measuring the association constant of bivalent noncovalent complexes are described.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electrospray Ionization for Mass Spectrometry of Large Biomolecules
Fenn, J. B., Mann, M., Meng, C. K., Wong, S. F., & Whitehouse, C. M. (1989) · Science · doi:10.1126/science.2675315 · Cited by 7,634
Laser desorption ionization of proteins with molecular masses exceeding 10,000 daltons
Karas, M., & Hillenkamp, F. (1988) · Analytical Chemistry · doi:10.1021/ac00171a028 · Cited by 5,637
Disintegration of water drops in an electric field
Taylor, G. I. (1964) · Proceedings of the Royal Society of London. Series A. Mathematical and Physical Sciences · doi:10.1098/rspa.1964.0151 · Cited by 3,305
Analytical Properties of the Nanoelectrospray Ion Source
Wilm, M., & Mann, M. (1996) · Analytical Chemistry · doi:10.1021/ac9509519 · Cited by 1,868
Self-citationDole, M., Mack, L. L., Hines, R. L., Mobley, R. C., Ferguson, L. D., & Alice, M. B. (1968) · The Journal of Chemical Physics · doi:10.1063/1.1670391 · Cited by 1,613
On the evaporation of small ions from charged droplets
Iribarne, J. V., & Thomson, B. A. (1976) · The Journal of Chemical Physics · doi:10.1063/1.432536 · Cited by 1,281
Electrospray and Taylor-Cone theory, Dole's beam of macromolecules at last?
Wilm, M. S., & Mann, M. (1994) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(94)04024-9 · Cited by 974
Self-citationCharge and fission of droplets in electrostatic sprays
Gomez, A., & Tang, K. (1994) · Physics of Fluids · doi:10.1063/1.868037 · Cited by 654
Field induced ion evaporation from liquid surfaces at atmospheric pressure
Thomson, B. A., & Iribarne, J. V. (1979) · The Journal of Chemical Physics · doi:10.1063/1.438198 · Cited by 631
Fernandez de la Mora, J. (2000) · Analytica Chimica Acta · doi:10.1016/s0003-2670(99)00601-7 · Cited by 528
Tang, L., & Kebarle, P. (1993) · Analytical Chemistry · doi:10.1021/ac00072a020 · Cited by 506
Nanoelectrospray—More than just a minimized-flow electrospray ionization source
Juraschek, R., Dülcks, T., & Karas, M. (1999) · Journal of the American Society for Mass Spectrometry · doi:10.1016/s1044-0305(98)00157-3 · Cited by 415
Ejsing, C. S., Duchoslav, E., Sampaio, J., Simons, K., Bonner, R., Thiele, C., Ekroos, K., & Shevchenko, A. (2006) · Analytical Chemistry · doi:10.1021/ac060545x · Cited by 415
Relating Electrospray Ionization Response to Nonpolar Character of Small Peptides
Cech, N. B., & Enke, C. G. (2000) · Analytical Chemistry · doi:10.1021/ac9914869 · Cited by 342
Of protons or proteins: “A beam's a beam for a' that.” (O.S. Burns)
Meng, C. K., Mann, M., & Fenn, J. B. (1988) · Zeitschrift für Physik D Atoms, Molecules and Clusters · doi:10.1007/bf01384871 · Cited by 254
Droplet Evaporation and Discharge Dynamics in Electrospray Ionization
Smith, J. N., Flagan, R. C., & Beauchamp, J. L. (2002) · The Journal of Physical Chemistry A · doi:10.1021/jp025723e · Cited by 251
Mass spectrometry and viral analysis
Siuzdak, G., Bothner, B., Yeager, M., Brugidou, C., Fauquet, C. M., Hoey, K., & Change, C.-M. (1996) · Chemistry & Biology · doi:10.1016/s1074-5521(96)90083-6 · Cited by 203
Conformation of GroEL-bound α-lactalbumin probed by mass spectrometry
Robinson, C. V., Groß, M., Eyles, S. J., Ewbank, J. J., Mayhew, M., Hartl, F. U., Dobson, C. M., & Radford, S. E. (1994) · Nature · doi:10.1038/372646a0 · Cited by 199
Peschke, M., Verkerk, U. H., & Kebarle, P. (2004) · Journal of the American Society for Mass Spectrometry · doi:10.1016/j.jasms.2004.05.005 · Cited by 184
Luedtke, W. D., Landman, U., Chiu, Y., Levandier, D. J., Dressler, R. A., Sok, S., & Gordon, M. S. (2008) · The Journal of Physical Chemistry A · doi:10.1021/jp804585y · Cited by 104
Grimm, R. L., & Beauchamp, J. L. (2009) · The Journal of Physical Chemistry A · doi:10.1021/jp907162w · Cited by 96
Hogan, C. J., Carroll, J. A., Rohrs, H. W., Biswas, P., & Gross, M. L. (2008) · Journal of the American Chemical Society · doi:10.1021/ja801280c · Cited by 79
Konermann, L. (2007) · The Journal of Physical Chemistry B · doi:10.1021/jp070720t · Cited by 78
Cited by
3D printed polyamide membranes for desalination
Chowdhury, M. R., Steffes, J., Huey, B. D., & McCutcheon, J. R. (2018) · Science · doi:10.1126/science.aar2122 · Cited by 570
High-Resolution Native Mass Spectrometry
Tamara, S., den Boer, M. A., & Heck, A. J. R. (2022) · Chemical Reviews · doi:10.1021/acs.chemrev.1c00212 · Cited by 511
Application of ’omics technologies to biomarker discovery in inflammatory lung diseases
Wheelock, C. E., Goss, V. M., Balgoma, D., Nicholas, B., Brandsma, J., Skipp, P. J., Snowden, S., Burg, D., D'Amico, A., Horvath, I., et al. (2013) · European Respiratory Journal · doi:10.1183/09031936.00078812 · Cited by 272
Metadata
- Authors
- Wilm, M.
- Venue
- Molecular & Cellular Proteomics
- Publisher
- Elsevier BV
- Published
- 2011-07
- Volume
- 10
- Issue
- 7
- Pages
- M111.009407
- ISSN
- 1535-9476 (ISSN-L)
- OpenAlex
- W2165010935
- Cited by
- 311
- References
- 23
- FWCI
- 7.11
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.