Hearing preservation in cochlear implantation for electric acoustic stimulation
The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Abstract
OBJECTIVE: To evaluate the possibility of preservation of low-frequency hearing in atraumatic cochlear implant electrode insertion procedures for combined, ipsilateral electric and acoustic stimulation. MATERIAL AND METHODS: A total of 21 patients were implanted with a MED EL C40+ cochlear implant using an atraumatic electrode insertion technique to preserve residual low-frequency hearing. Pure-tone audiometric thresholds were measured pre- and postoperatively to evaluate the degree of preserved hearing. Speech discrimination tests in quiet and with background noise were performed in a patient with successful hearing preservation. RESULTS: Using the atraumatic electrode insertion procedure with an insertion depth of 360 degrees (18-24 mm), hearing preservation could be achieved in 18/21 patients (85.7%). Three patients (14.3%) lost their residual low-frequency hearing after the implantation. Residual hearing was preserved completely in 13 patients (61.9%) and partial hearing preservation was possible in 5 (23.8%). Preliminary speech discrimination tests showed a dramatic benefit for the combined electric and acoustic stimulation mode compared to cochlear implantation alone. CONCLUSION: Preservation of low-frequency hearing in cochlear implantation is possible in patients implanted because of profound high-frequency deafness. With the development of new, more atraumatic electrode designs, preservation of residual hearing should be further improved.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Electric-Acoustic Stimulation of the Auditory System
vonIlberg, C., Kiefer, J., Tillein, J., Pfenningdorff, T., Hartmann, R., Stürzebecher, E., & Klinke, R. (1999) · ORL · doi:10.1159/000027695 · Cited by 508
Self-citationConservation of low-frequency hearing in cochlear implantation
Kiefer, J., Gstoettner, W. K., Baumgartner, W., Pok, S. M., Tillein, J., Ye, Q., & Ilberg, C. V. (2004) · Acta Oto-Laryngologica · doi:10.1080/00016480310000755a · Cited by 309
Self-citationLeake, P. A., Hradek, G. T., & Snyder, R. L. (1999) · The Journal of Comparative Neurology · doi:10.1002/(sici)1096-9861(19991004)412:4<543::aid-cne1>3.0.co;2-3 · Cited by 276
Adunka, O., Kiefer, J., Unkelbach, M. H., Lehnert, T., & Gstoettner, W. (2004) · The Laryngoscope · doi:10.1097/00005537-200407000-00018 · Cited by 184
Self-citationComparison of electrode position in the human cochlea using various perimodiolar electrode arrays
Tykocinski, M., Cohen, L. T., Pyman, B. C., ROLANDJR, T., Treaba, C. G., Palamara, J. E. A., DAHM, M., Shepherd, R. K., Xu, J., & Cowan, R. S. (2000) · American Journal of Otolaryngology · doi:10.1016/s0196-0709(00)80010-1 · Cited by 112
Perimodiolar Electrodes in Cochlear Implant Surgery
Gstoettner, O. A. W. K. (2001) · Acta Oto-Laryngologica · doi:10.1080/000164801300043569 · Cited by 85
The Clarion electrode positioner: Temporal bone studies
Fayad, J. N., Luxford, W. M., & Linthicum, F. H. (2000) · American Journal of Otolaryngology · doi:10.1016/s0196-0709(00)80013-7 · Cited by 47
A clinical and experimental study of the effect of fenestration on the labyrinthine contents.
Shambaugh, G. E., & TAKAHARA, S. (1955) · PubMed · Cited by 38
Cited by
Cochlear implants: A remarkable past and a brilliant future
Wilson, B. S., & Dorman, M. F. (2008) · Hearing Research · doi:10.1016/j.heares.2008.06.005 · Cited by 868
Cochlear implants: Current designs and future possibilities
Wilson, B. S. (2008) · The Journal of Rehabilitation Research and Development · doi:10.1682/jrrd.2007.10.0173 · Cited by 396
Combining acoustic and electrical hearing
Gantz, B. J., & Turner, C. W. (2003) · The Laryngoscope · doi:10.1097/00005537-200310000-00012 · Cited by 377
The Size of the Cochlea and Predictions of Insertion Depth Angles for Cochlear Implant Electrodes
Escudé, B., James, C., Deguine, O., Cochard, N., Eter, E., & Fraysse, B. (2006) · Audiology and Neurotology · doi:10.1159/000095611 · Cited by 376
The cochlear implant: historical aspects and future prospects
Eshraghi, A. A., Nazarian, R., Telischi, F. F., Rajguru, S. M., Truy, E., & Gupta, C. (2012) · The Anatomical Record · doi:10.1002/ar.22580 · Cited by 285
“…trauma caused to the cochlea from different multichannel cochlear implant electrodes (O’Leary et al., 1991; Welling et al., 1993; Gstoettner, 1997; Nadol et al., 2001; Adunka et al., 2004; Gstoettner et al., 2004; Roland, 2005; Fraysse et al., 2006; Rebscher et al., 2008; Helbig et al., 2011).”
BackgroundMED-EL Cochlear Implants: State of the Art and a Glimpse Into the Future
Hochmair, I., Nopp, P., Jolly, C., Schmidt, M., Schößer, H., Garnham, C., & Anderson, I. (2006) · Trends in Amplification · doi:10.1177/1084713806296720 · Cited by 254
In Vivo Estimates of the Position of Advanced Bionics Electrode Arrays in the Human Cochlea
Skinner, M. W., Holden, T. A., Whiting, B. R., Voie, A. H., Brunsden, B., Neely, J. G., Saxon, E. A., Hullar, T. E., & Finley, C. C. (2007) · Annals of Otology, Rhinology & Laryngology · doi:10.1177/000348940711600401 · Cited by 243
Fraysse, B., Macías, Á. R., Sterkers, O., Burdo, S., Ramsden, R., Deguine, O., Klenzner, T., Lenarz, T., Rodriguez, M. M., Von Wallenberg, E., et al. (2006) · Otology & Neurotology · doi:10.1097/01.mao.0000226289.04048.0f · Cited by 237
“Other approaches reported in the literature include the use of smaller insertion depth angles (e340 degrees) achieved with the partial insertion (18Y24 mm) of a straight electrode array (10,11) or the use of a shorter and thinner 10-mm electrode array such as the Nucleus Hybrid CI (8).”
BackgroundMethodInfluentialTowards a consensus on a hearing preservation classification system
Skarzynski, H., van de Heyning, P., Agrawal, S., Arauz, S. L., Atlas, M., Baumgartner, W., Caversaccio, M., de Bodt, M., Gavilan, J., Godey, B., et al. (2013) · Acta Oto-Laryngologica · doi:10.3109/00016489.2013.869059 · Cited by 226
“More residual hearing and/or healthier neural interface promote(s) better speech discrimination due to the presence of additional acoustic cues and/or larger amounts of electrically induced information [9,10], and may also allow today’s severely deaf users to benefit from treatment modalities not yet invented.”
BackgroundSelf-citationZhang, T., Dorman, M. F., & Spahr, A. J. (2010) · Ear & Hearing · doi:10.1097/aud.0b013e3181b7190c · Cited by 177
“It has been well documented that low-frequency information, which is not well transmitted by cochlear implants, can be provided to patients through residual low-frequency acoustic hearing in the implanted ear or in the nonimplanted ear (Shallop et al. 1992; Armstrong et al. 1997; Tyler et al. 2002; Ching et al. 2004;…”
BackgroundConservation of Residual Acoustic Hearing After Cochlear Implantation
Balkany, T. J., Connell, S. S., Hodges, A. V., Payne, S. L., Telischi, F. F., Eshraghi, A. A., Angeli, S. I., Germani, R., Messiah, S., & Arheart, K. L. (2006) · Otology & Neurotology · doi:10.1097/01.mao.0000244355.34577.85 · Cited by 176
“(8) evaluated 21 patients after implantation with Med El Combi 40+ CI using a hearing conservation surgical technique.”
MethodElectric acoustic stimulation of the auditory system: results of a multi-centre investigation
Gstoettner, W. K., Van de Heyning, P., Fitzgerald O'Connor, A., Morera, C., Sainz, M., Vermeire, K., McDonald, S., Cavallé, L., Helbig, S., García Valdecasas, J., et al. (2008) · Acta Oto-Laryngologica · doi:10.1080/00016480701805471 · Cited by 170
“9 mm) using the Frankfurt EAS surgical technique [4,5,8].”
BackgroundMethodSelf-citationGantz, B. J., Turner, C., & Gfeller, K. E. (2006) · Audiology and Neurotology · doi:10.1159/000095616 · Cited by 170
“This approach differs from those using a longer electrode [Gstoettner et al., 2004].”
Result
Metadata
- Authors
- Gstoettner, W., Kiefer, J., Baumgartner, W.-D., Pok, S., Peters, S., & Adunka, O.
- Venue
- Acta Oto-Laryngologica
- Publisher
- Informa UK Limited
- Published
- 2004-05-01
- Volume
- 124
- Issue
- 4
- Pages
- 348-352
- ISSN
- 0001-6489 (ISSN-L)
- 1651-2251
- OpenAlex
- W2130327073
- Cited by
- 277
- References
- 8
- FWCI
- 6.88
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.