Current databases on biological variation: pros, cons and progress
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A database with reliable information to derive definitive analytical quality specifications for a large number of clinical laboratory tests was prepared in this work. This was achieved by comparing and correlating descriptive data and relevant observations with the biological variation information, an approach that had not been used in the previous efforts of this type. The material compiled in the database was obtained from published articles referenced in BIOS, CURRENT CONTENTS, EMBASE and MEDLINE using "biological variation & laboratory medicine" as key words, as well as books and doctoral theses provided by their authors. The database covers 316 quantities and reviews 191 articles, fewer than 10 of which had to be rejected. The within- and between-subject coefficients of variation and the subsequent desirable quality specifications for precision, bias and total error for all the quantities accepted are presented. Sex-related stratification of results was justified for only four quantities and, in these cases, quality specifications were derived from the group with lower within-subject variation. For certain quantities, biological variation in pathological states was higher than in the healthy state. In these cases, quality specifications were derived only from the healthy population (most stringent). Several quantities (particularly hormones) have been treated in very few articles and the results found are highly discrepant. Therefore, professionals in laboratory medicine should be strongly encouraged to study the quantities for which results are discrepant, the 90 quantities described in only one paper and the numerous quantities that have not been the subject of study.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, the characteristics of the populations studied in the papers included in the historical estimates varied and include diseased (uncomplicated myocardial infarction, liver disease, type 1 diabetes mellitus) and non-diseased subjects [12, 16].”
From The European Biological Variation Study (EuBIVAS): a summary report (2022) · cites this paper as [12]
Citations
Cites
Generation and Application of Data on Biological Variation in Clinical Chemistry
Fraser, G. G., & Harris, E. K. (1989) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408368909106595 · Cited by 870
Fraser, C. G., Petersen, P. H., Ricós, C., & Haeckel, R. (1992) · PubMed · Cited by 125
The application of theoretical goals based on biological variation data in proficiency testing.
Cg, F. (1988) · PubMed · Cited by 119
(1997) · PubMed · Cited by 102
Biological variation in clinical chemistry. An update: collated data, 1988-1991.
Fraser, C. G. (1992) · PubMed · Cited by 91
The "index of fiduciality" proposed for use in evaluation and comparison of methods.
Fraser, C. G., & Browning, M. C. (1988) · Clinical Chemistry · doi:10.1093/clinchem/34.6.1356 · Cited by 13
Research works printed but not linked: 3
- Fraser CG, 1988, Arch Pathol Lab Med, 112, 404
- Fraser CG, 1992, Collated data, 1988-1991. Arch Pathol Lab Med, 116, 916
- Fraser CG, 1992, Eur J Clin Chem Clin Biochem, 30, 311
Cited by
Items 901–1,000 of 1,000
Estimation of glomerular filtration rate in acute kidney injury
Lippi, G., & Cervellin, G. (2012) · Clinica Chimica Acta · doi:10.1016/j.cca.2012.08.008 · Cited by 1
Sobas, F., Tsiamyrtzis, P., Benattar, N., Lienhart, A., & Négrier, C. (2014) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0000000000000105 · Cited by 1
Multicentre evaluation of glycated haemoglobin (HbA1c) of Roche Diagnostics in Andalusia
Sáez-Benito, A., Chozas, J. M. V., Ronchel, A. M., Alor, F. B., Ramírez, L. P., Álvarez, N. M. C., Fernández, J. D. L. T., Luque, F. N., Reina, M. V. C., Peña, R. A., et al. (2014) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2014.04.006 · Cited by 1
“According to glycohemoglobin biological variability data [5], it is recommended a precision value of 2%, having been established by expert”
MethodLaboratory Evaluation of the STA Satellite Benchtop Coagulation Instrument
Su, H. T., Whelchel, K. L., Sonnek, M. J., & Cutsforth, G. A. (2013) · Laboratory Medicine · doi:10.1309/lmq4fyeib3o0wirl · Cited by 1
Dhawan, A., Parikh, D. S., Shugman, I., French, J. K., Hallani, H., Fernandes, C., & Juergens, C. (2011) · The Medical Journal of Australia · doi:10.5694/mja11.10368 · Cited by 1
The Hemo One Autoanalyzer for Glycated Hemoglobin Assay
Pocino, K., Molinario, R., Manieri, R., Bianucci, L., & Capoluongo, E. (2016) · Laboratory Medicine · doi:10.1093/labmed/lmv034 · Cited by 1
Analytical assessment of the novel homocysteine liquid enzymatic assay on Beckman Coulter AU5800
Dipalo, M., Dipietro, M., Gnocchi, C., Musa, R., Aloe, R., & Lippi, G. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0425 · Cited by 1
Release of Cardiac Biomarkers during a Cycling Race
Goff, C. M. L., Kaux, J., d’Otreppe, S., Goffaux, S., Fillet, M., Chapelle, J.-P., & Cavalier, E. (2016) · World Journal of Cardiovascular Diseases · doi:10.4236/wjcd.2016.68032 · Cited by 1
Guichet, C., & Hurtgen, C. (2017) · Radioprotection · doi:10.1051/radiopro/2017012 · Cited by 1
“…de biologie clinique (Vassault et al., 1999) ou le Groupe français d’étude sur l’hémostase et la thrombose (GEHT, 2014), des articles scientifiques (Ricos et al., 1999) ou bien des performances d’incertitudes fixées réglementairement, comme cela peut exister par exemple pour la mesure de…”
BackgroundHilderink, J. M., Rennenberg, R. J. M. W., Vanmolkot, F. H. M., Bekers, O., Koopmans, R. P., & Meex, S. J. R. (2017) · BMJ Open · doi:10.1136/bmjopen-2017-015854 · Cited by 1
Graindor, N., Blomme, S., Jughmans, S., Boeckx, N., & Kieffer, D. (2017) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12747 · Cited by 1
Moya‐Salazar, J., & Pio-Dávila, L. (2018) · Medicina Universitaria · doi:10.24875/rmu.m18000010 · Cited by 1
Diagnostic biochemical markers for heart failure
Mbagaya, W., Luvai, A., & Waise, A. (2018) · Practical Diabetes · doi:10.1002/pdi.2183 · Cited by 1
Can calculated total nitrogen replace Kjeldahl total nitrogen measurements in 24-h urine samples?
Peeters, B., Dirinck, E. L., Gaal, L. V., & Roosens, L. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0144 · Cited by 1
Monneret, D. (2018) · F1000Research · doi:10.12688/f1000research.17081.2 · Cited by 1
Secretaría de Salud de Guerrero, B. D. S. R. Z. C., Chávez-Almazán, L. A., Sotelo, W. B., Tecnológico Nacional de México, I. T. D. A., García, J. Á. C., Tecnológico Nacional de México, I. T. D. A., Díaz-Ortíz, J. A., & Secretaría de Salud de Guerrero, L. E. D. S. P. (2019) · Revista Internacional de Contaminación Ambiental · doi:10.20937/rica.2019.35.02.19 · Cited by 1
“(Ricos et al. 1999).”
BackgroundInfluentialSurvey on common reference intervals for general chemistry analytes in Hong Kong
Chan, T. C. H., Mak, C. M., Chen, S. P., Leung, M., Cheung, H., Leung, D. C. W., Lee, H., Koo, E. C., & Lo, Y. (2019) · Hong Kong Medical Journal · doi:10.12809/hkmj197943 · Cited by 1
Blood from heparin tubes is an acceptable alternative to assess hematocrit determination
Pekar, J. D., Carpentier, T., Maboudou, P., & Grzych, G. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-0112 · Cited by 1
Analysis of a 6-year pilot external quality assurance survey of free light chain using Sigma metrics
Chae, H., Yoo, J., Park, J., Cha, K., Lee, J. J., Cho, B., Kim, M., & Kim, Y. (2019) · Journal of Laboratory Medicine · doi:10.1515/labmed-2018-0175 · Cited by 1
Quality planning and control strategy for AQT90 flex Radiometer® in point of care testing
Ilardo, C., Reynaud, C., Bonneton, R., & Barthes, J. (2020) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2020.1768585 · Cited by 1
Effect of changes in laboratory light intensity on biochemistry and haemogram analysis
Yilmaz, S. (2020) · Turkish Journal of Biochemistry · doi:10.1515/tjb-2019-0124 · Cited by 1
Ricós, C., Fernández–Calle, P., González-Lao, E., Simón, M., Díaz–Garzón, J., Boned, B., Marqués-García, F., Minchinela, J., Perich, C., Tejedor-Ganduxé, X., et al. (2020) · Advances in Laboratory Medicine / Avances en Medicina de Laboratorio · doi:10.1515/almed-2020-0040 · Cited by 1
“En 1999 la Comisión de Calidad Analítica de la SEQCML [4] compendió todas las publicaciones que contenían estimados de la VB en una base de datos que se fue actualizando cada dos años hasta 2014 [5], siguiendo un criterio de inclusión de artículos que ha sido descrito en detalle por Perich y colaboradores [6].”
BackgroundInfluentialThe evaluation of analytical performance of Total PSA and Free PSA tests by using 6-sigma method
Yücel, Ç., Ercan, M., & Kızılgün, M. (2021) · Turkish Bulletin of Hygiene and Experimental Biology · doi:10.5505/turkhijyen.2020.19052 · Cited by 1
Influencia de los anticoagulantes EDTAK2 y EDTAK3 en los resultados del hemograma
Goedelmann, C. J., Benavidez, C., Durando, M. C., Garcia, R. V., Cid, M. P. G., Sala, M. C., & Paz, L. (2018) · Acta bioquímica clínica latinoamericana/Acta bioquímica clínica latinoamericana · Cited by 1
Mina, A., Banukumar, S., & Vazquez, S. (2021) · Journal of Analytical & Pharmaceutical Research · doi:10.15406/japlr.2021.10.00385 · Cited by 1
Total Error and Proficiency Testing
Westgard, S. A., & Freeman, K. P. (2022) · Wiley eBooks · doi:10.1002/9781119500537.ch138 · Cited by 1
(2017) · International Journal of Clinical Chemistry and Laboratory Medicine · doi:10.20431/2455-7153.0303005 · Cited by 1
Sáu, T. T., & Minh, N. V. (2022) · Tạp chí Y học Việt Nam · doi:10.51298/vmj.v515i1.2723 · Cited by 1
Evaluation of high speed centrifugation for routine biochemistry
Dupuy, A., Cau, I., Badiou, S., & Cristol, J. (2022) · Clinica Chimica Acta · doi:10.1016/j.cca.2022.06.029 · Cited by 1
Tiroid Fonksiyon Testlerinde Diürnal Ritm ve Postprandial Değişim
İhtiyar, A. H., Arslan, F. D., & Köseoğlu, M. (2022) · Journal of Turkish Clinical Biochemistry · doi:10.56615/tkbd.2022.11 · Cited by 1
Wolan, V., Kunst, A., Gauvreau, C., Zimmer, C., Ly, E., Higgins, T., & Tsui, A. K. Y. (2022) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2022.10.001 · Cited by 1
La variabilità biologica e gli indicatori di neoplasia: un update (2022)
Dorizzi, R. M., Toniato, E., Vero, A., D’Amato, M., Esposito, J. E., Pulcini, R., POLILLI, E., & Martinotti, S. (2023) · La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine · doi:10.23736/s1825-859x.23.00177-9 · Cited by 1
Rest reduces venous lactate levels significantly in patients in outpatient clinic
Fly, L. H., Bergholt, N. L., & Brasen, C. L. (2023) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2023.2225224 · Cited by 1
Rheumatoid Factor and ASO assessment by immunoturbidimetry and immunonephelometry
Güven, B. (2024) · International journal of medical biochemistry/International journal of medical biochemistry : · doi:10.14744/ijmb.2024.82612 · Cited by 1
The precision and bias of measurement methods according to EP15 A3
Ambrožová, J., & Kratochvíla, J. (2016) · Klinická biochemie a metabolismus · doi:10.61568/kbm.2016.031 · Cited by 1
Yılmaz, F. M., Züngün, C., & Çakır, B. (2014) · Journal of Clinical and Experimental Investigations · doi:10.5799/ahinjs.01.2014.03.0420 · Cited by 1
“The judgment of acceptability depends on what amount of analytical error is allowable without affecting or limiting the use and interpretation of individual test results [10].”
BackgroundMejías, M., Méndez, A., & Moreno, A. (2020) · ACTA CIENTIFICA DE LA SOCIEDAD VENEZOLANA DE BIOANALISTAS ESPECIALISTAS · Cited by 1
Cailliat, M. C. (2011) · El Servicio de Difusión de la Creación Intelectual (National University of La Plata) · doi:10.35537/10915/2703 · Cited by 1
Quality Control in Laboratory Medicine
Strike, P. W. (2005) · Wiley eBooks · doi:10.1002/0470011815.b2a06016 · Cited by 1
Salvagno, G. L., Lippi, G., Tarperi, C., Guidi, G. C., & Schena, F. F. (2014) · Drug Testing and Analysis · doi:10.1002/dta.1704 · Cited by 1
Sharpening the CALIPER: Defining pre-analytic and biologic variability in children
Dietzen, D. J. (2012) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2012.08.016 · Cited by 1
Natriuretic peptides and evidence-based quality specifications
Plebani, M., & Siest, G. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.089 · Cited by 1
“Another advantage of this model is that data on components of biological variation are available on many more quantities (5), thus facilitating compilation of data.”
BackgroundEvaluation and Improvement of Clinical Chemical Laboratory Tests for Glomerular Function
Harmoinen, A. P. T. (2001) · Tampere University Institutional Repository (Tampere University) · Cited by 1
Estimation of Preanalytical Uncertainty in Clinical Chemistry
Sylte, M. S. (2013) · NORA - Norwegian Open Research Archives · Cited by 1
Chowdhury, N., Jain, A., & Jain, S. (2018) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12898 · Cited by 1
Modelling optimal use of tests for monitoring disease progression and recurrence
Sitch, A. (2019) · University of Birmingham Institutional Research Archive (University of Birmingham) · Cited by 1
Analytical quality control of INR measurements in primary care
Stavelin, A. V. (2013) · NORA - Norwegian Open Research Archives · Cited by 1
Aakre, K. M. (2011) · NORA - Norwegian Open Research Archives
Métrologie en biologie médicale: un nouveau challenge
Giroud, C. (2006) · Bio Tribune Magazine · doi:10.1007/bf03010082
Clinical Laboratory Safety Data
Craig, A. (2011) · Wiley eBooks · doi:10.1002/9780470975053.ch5
Uncertainty in Clinical Chemistry Measurements Including Preanalytical Variables
Sylte, M. S., Wentzel‐Larsen, T., & Bolann, B. J. (2012) · Wiley eBooks · doi:10.1002/9781118271858.ch3
Yakubovich, N. (2012) · MacSphere (McMaster University) · doi:10.71548/20534
Effect of contaminant 0.9% saline on tests of haemostasis
Lippi, G., Buonocore, R., Pietro, M. D., Ippolito, L., & Favaloro, E. J. (2015) · Anaesthesia · doi:10.1111/anae.13151
Estimation of the biological variation of glucose-6-phosphate dehydrogenase in dried blood spots
Reclos, G. J., Tanyalçın, T., & Pass, K. A. (2006) · Accreditation and Quality Assurance · doi:10.1007/s00769-006-0144-6
Metrology in an ISO 15189 accredited medical biology laboratory
Guichet, C., & Pellegrinelli, S. (2014) · International Journal of Metrology and Quality Engineering · doi:10.1051/ijmqe/2014016
Bonvicini, P., Metus, P., Pavón, M. A., & Tocchini, M. (2003) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2003.105
“Furthermore, the data of biological variation are often not “robust” enough, as demonstrated by the different values reported in literature (9).”
BackgroundCritical comments on ‘Significance of a change between two consecutive measured values’
Petersen, P. H. (2011) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2011.637576
“[7] in a publication of a large table showing increasing within-subject estimates of serum-cholesterol with increasing length of investigation.”
BackgroundJanssen, M. J. W., Gruyter, H. L. M. D., Stappers, P. M. G., Velmans, M. H., van den Ouweland, J. M. W., van Daal, H., & Hampsink, R. M. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.319
Kowalski, S. R., & Tan, M. F. (2010) · Journal of Pharmacy Practice and Research · doi:10.1002/j.2055-2335.2010.tb00534.x
Calcium metabolism and breast cancer risk
Almquist, M. (2009) · Lund University Publications (Lund University)
Chedid, F. D., Imran, A., Durrani, N. U. R., Musharaf, I., Rehman, M., & Datt, G. (2010) · Early Human Development · doi:10.1016/j.earlhumdev.2010.09.046
Sarli, M., Spivacow, R., Pedroarias, V., Ej, R., & Zanchetta, J. (2007) · Current Therapeutic Research · doi:10.1016/j.curtheres.2007.03.002
A Six Sigma approach towards analytical quality control
Slinger, J., & Hudig, F. (2004)
พุทธรักษ์, พ. (n.d.) · Thai Science and Technology Journal · doi:10.14456/tstj.2016.9
Especificações de qualidade analítica
Zaragoza, J. M. M. (2011) · Acta Farmacêutica Portuguesa
Rim, J. H., Ahn, H.-J., Yoon, K. K., Kim, H. R., Kim, Y.-A., Lim, H. S., & Yoo, J. (2015) · Laboratory Medicine Online · doi:10.3343/lmo.2016.6.1.19
“또한 패혈증의 기준이 될 수 있는 임상적으로 중요한 농도에서 기존 문헌[8, 9]의 허용오차범위를 적 용하였을 때 상관성 방정식을 이용하여 예측되는 농도는 CRP와 PCT 모두 해당 구간 안에 포함되는 것을 확인함으로써 우수한 상 관성으로 판단되었다.”
Cappellani, A., Cappellini, F., Biella, F., Sciarini, F., Parma, C., Limonta, G., Mocarelli, P., & Brambilla, P. (2009) · BOA (University of Milano-Bicocca)
Management of Hyperglycemia in Hospitalized Patients: Critical Care Setting
Grassi, G., & Bonomo, M. A. (2014) · Frontiers in diabetes · doi:10.1159/000363462
Kim, H. J., Ji, M., Moon, H., Hur, M., & Yun, Y. (2016) · Laboratory Medicine Online · doi:10.3343/lmo.2016.6.2.64
“검사장비 및 시약의 정밀도 평가에는 일반적으로 개인 내 생물 학적 변이(within-subject biological variation)에 따라 설정된 검사 정밀도 허용기준(desirable analytical precision criteria)이 사용되 며, 통상적으로 검사정밀도가 개인 내 생물학적 변이의 50% 이내 인 경우 적합하게 여겨진다[9-11].”
Insulin-like growth factor-I (IGF-I) and clinical
Gu, S. (2013)
Pers P ective sP ecial Focus: anti-do P ing analysis & the olym P ics
Friedmann, T., Flenker, U., Alsayrafi, M., Sottas, P., Williams, S. A., & Gill, R. D. (2012)
Arboleya, Z. C. (2016) · Repositorio de la Universidad de Oviedo (RUO)
Evaluation of Vacutainer Distribution Conditions
Park, C.-E. (2016) · Korean Journal of Clinical Laboratory Science · doi:10.15324/kjcls.2016.48.2.109
“분석평가의 통계적 관점에서는 RST (rapid separate tube)와 SST (serum separate tube)를 비교평가 한 이전의 보고[14]에서 결과분석처럼 개체내 변이계수(within-subject coefficients of variation, CVw)와 개체간 변이계수(between-subject coefficients of variation, CVg)를 조사하는 개념을 기반으로[15].”
Usta, M., Aral, H., Çilingirtürk, A. M., Kural, A., Topaç, I., Semerci, T., & Köseoğlu, M. (2016) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2016.1210225
“9, which is the value of the reported desirable specification for imprecision [I(%)] [31,33].”
BackgroundHematoloogiline analüüs: täiskasvanute referentsvahemikud ja kliiniliselt oluliste muutuste piirid
Tamm, A., Beljaev, K., Tomberg, K., Palo, K., Topmann, M., & Kärtner, U. (2003) · Ajakirjad. Journals by UT · doi:10.15157/ea.v0i0.9511
“Meie tulemuste võrdlus suurimas vastavas andmebaasis (15) toodud piiridega bioloogilise variatsiooni kohta kinnitab, et need tulemused on tõesti sellistes suurusjärkudes.”
BackgroundBianchi, V., Martino, F. D., Piccinini, S., Pinca, A., Sida, G., & Riva, F. (2015) · Working Paper of Public Health · doi:10.4081/wpph.2015.6702
Performance Evaluation of Cartridge-Type Blood Gas Analyzer: i-Smart 300
Yi, A., Kim, H., Moon, H., Hur, M., & Yun, Y. (2016) · Laboratory Medicine Online · doi:10.3343/lmo.2017.7.1.20
A photonic crystal biosensor application for assessment of iron deficiency
Peterson, R. (2016) · Illinois Digital Environment for Access to Learning and Scholarship (University of Illinois at Urbana-Champaign)
Analytical Evaluation of the Clinical Chemistry Analyzer AU 480 Beckman Coulter
Abebe, N. (2016) · European Journal of Clinical and Biomedical Sciences · doi:10.11648/j.ejcbs.20160206.11
“Likewise, all the five analytes’ imprecision were comparable to the desirable specification for imprecision and the recommended biological variations as shown in table three [8, 9, 10].”
BackgroundBarbir, R., Zorić, M., Perkov, S., Počanić, D., Svaguša, T., & Prkačin, I. (2017) · Southeastern European medical journal · doi:10.26332/seemedj.v1i1.19
“and colleagues (6), and manufacturer’s criteria for within-laboratory precision was also 5,00 %, which indicates that Table 1.”
BackgroundLippi, G., Giavarina, D., Poli, G., Montagnana, M., Soffiati, G., Clinica, M., & Bortolo, O. S. (2005) · Padua Research Archive (University of Padova)
Relating Laboratory Performance to Quality Required for Intended Clinical Use
Dalenberg, D. A., Schryver, P. G., & Klee, G. G. (2013)
Oppliger, S., Hartnack, S., & Riond, B. (2013)
Statistical Concepts in Laboratory Quality Control
Momeni, A., Pincus, M. R., & Libien, J. M. (2017) · Springer eBooks · doi:10.1007/978-3-319-60543-2_11
Usporedba metoda za određivanje aktivnosti aminotransferaza sa i bez dodatka piridoksal fosfata
Milakara, A. (2017) · Repozitorij Farmaceutsko-biokemijskog fakulteta (Sveučilišta u Zagrebu)
Clinical Studies In (Para)Thyroid Surgery
Dulfer, R. R. (2018) · RePub (Erasmus University Rotterdam)
Performance Evaluation of the Point-of-Care Cardiac Troponin T Assay
Kim, Y. H., Jeong, T., & Hong, K.-S. (2018) · Laboratory Medicine Online · doi:10.3343/lmo.2018.8.4.135
Anderson, N. R. (2026) · Warwick Research Archive Portal (University of Warwick) · doi:10.82444/warw.33765487
Alarming (or Near-Critical) Results Are Highlighted to Alleviate Adverse Outcome
Benmouyal, E. (2019) · SN Comprehensive Clinical Medicine · doi:10.1007/s42399-019-0040-0
Performance of HemosIL ReadiPlasTin, a Liquid Reagent for Prothrombin Time Measurement
Shin, S., Jung, Y., Song, W., & Park, M.-J. (2019) · Imsang byeong'ri wa jeongdo gwanri/Journal of laboratory medicine and quality assurance · doi:10.15263/jlmqa.2019.41.1.9
“3%를 기준으로 하였을 때 허용 가능한 범위였으므로 임상적 중요 의사결정에 미치는 영향은 크지 않을 것으로 생각 되었다[5] (https://www.”
Performance verification and sigma metrics of creatinine assays
Jagtap, S. B., Bandebuche, S., & Hegde, M. (2018) · International Journal of Clinical Biochemistry and Research · doi:10.18231/2394-6377.2018.0024
Six Sigma: Tool for Quality and Cost Effectiveness
Rasalkar, K. (2019) · Journal of Medical Science And clinical Research · doi:10.18535/jmscr/v7i10.33
Reguengos, J. (2017) · Portuguese National Funding Agency for Science, Research and Technology (RCAAP Project by FCT)
Wright, E. (2019) · Enlighten: Theses (The University of Glasgow) · doi:10.5525/gla.thesis.76741
(2014) · PubMed
Metadata
- Authors
- C. Ricós, V. A.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1999-01
- Volume
- 59
- Issue
- 7
- Pages
- 491-500
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2119950421
- Cited by
- 987
- References
- 6
- Citations by year
- 2026: 17 · 2025: 25 · 2024: 22 · 2023: 29 · 2022: 41 · 2021: 44 · 2020: 47 · 2019: 51 · 2018: 64 · 2017: 69 · 2016: 58 · 2015: 46 · 2014: 76 · 2013: 56 · 2012: 55
- FWCI
- 5.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Scandinavian Journal of Clinical and Laboratory Investigation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- biological variation, reference values, clinical laboratory testing, within-subject coefficient of variation, total error, bias and precision, disease states, hormones
- MeSH terms
- Humans, Quality Control, Clinical Laboratory Techniques, Databases as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.