Current databases on biological variation: pros, cons and progress
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A database with reliable information to derive definitive analytical quality specifications for a large number of clinical laboratory tests was prepared in this work. This was achieved by comparing and correlating descriptive data and relevant observations with the biological variation information, an approach that had not been used in the previous efforts of this type. The material compiled in the database was obtained from published articles referenced in BIOS, CURRENT CONTENTS, EMBASE and MEDLINE using "biological variation & laboratory medicine" as key words, as well as books and doctoral theses provided by their authors. The database covers 316 quantities and reviews 191 articles, fewer than 10 of which had to be rejected. The within- and between-subject coefficients of variation and the subsequent desirable quality specifications for precision, bias and total error for all the quantities accepted are presented. Sex-related stratification of results was justified for only four quantities and, in these cases, quality specifications were derived from the group with lower within-subject variation. For certain quantities, biological variation in pathological states was higher than in the healthy state. In these cases, quality specifications were derived only from the healthy population (most stringent). Several quantities (particularly hormones) have been treated in very few articles and the results found are highly discrepant. Therefore, professionals in laboratory medicine should be strongly encouraged to study the quantities for which results are discrepant, the 90 quantities described in only one paper and the numerous quantities that have not been the subject of study.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, the characteristics of the populations studied in the papers included in the historical estimates varied and include diseased (uncomplicated myocardial infarction, liver disease, type 1 diabetes mellitus) and non-diseased subjects [12, 16].”
From The European Biological Variation Study (EuBIVAS): a summary report (2022) · cites this paper as [12]
Citations
Cites
Generation and Application of Data on Biological Variation in Clinical Chemistry
Fraser, G. G., & Harris, E. K. (1989) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408368909106595 · Cited by 870
Fraser, C. G., Petersen, P. H., Ricós, C., & Haeckel, R. (1992) · PubMed · Cited by 125
The application of theoretical goals based on biological variation data in proficiency testing.
Cg, F. (1988) · PubMed · Cited by 119
(1997) · PubMed · Cited by 102
Biological variation in clinical chemistry. An update: collated data, 1988-1991.
Fraser, C. G. (1992) · PubMed · Cited by 91
The "index of fiduciality" proposed for use in evaluation and comparison of methods.
Fraser, C. G., & Browning, M. C. (1988) · Clinical Chemistry · doi:10.1093/clinchem/34.6.1356 · Cited by 13
Research works printed but not linked: 3
- Fraser CG, 1988, Arch Pathol Lab Med, 112, 404
- Fraser CG, 1992, Collated data, 1988-1991. Arch Pathol Lab Med, 116, 916
- Fraser CG, 1992, Eur J Clin Chem Clin Biochem, 30, 311
Cited by
Items 801–900 of 1,000
When and how to measure lipids and their role in CHD risk prediction
Richmond, W. (2003) · The British Journal of Diabetes · doi:10.1177/14746514030030030601 · Cited by 3
van Schaardenburg, D., Weekamp, H. H., van der Lugt, C. P., van de Laar, M. A. F. J., & Veer, G. V. D. S. (2008) · Nederlandsch tijdschrift voor geneeskunde/Nederlands tijdschrift voor geneeskunde/NTvG-databank · Cited by 3
Déchelotte, B., Girot, H., Chagraoui, A., Prévost, G., & Brunel, V. (2016) · Clinica Chimica Acta · doi:10.1016/j.cca.2016.09.014 · Cited by 3
Analytical performance of the new analyzer BA 400 Biosystems with LED technology
Molinario, R., Autilio, C., Daloiso, P. D., Pocino, K., Colacicco, L., Zuppi, C., & Antenucci, M. (2014) · Clinical Laboratory · doi:10.7754/clin.lab.2014.140312 · Cited by 3
Analytical Performance of Specific-Protein Assays on the Abbott Aeroset System
Duly, E. B., Barnes, G., Grimason, S., & Trinick, T. R. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.9.1709 · Cited by 3
MURPHY, M. H., Breslin, G., Trinick, T. R., McClean, C. M., Moore, W., Duly, E. B., & Davison, G. (2011) · European Journal of Applied Physiology · doi:10.1007/s00421-011-2003-3 · Cited by 3
Ludwig, P., Leidinger, E. F., & Hooijberg, E. H. (2012) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2012.00426.x · Cited by 3
Speziale, A. M. T. (2006) · Revista Latinoamericana de Patología Clínica y Medicina de Laboratorio · Cited by 3
Evaluation of the accuracy of complete blood count for insufficient blood samples
Pan, L., Shih, C.-H., Lee, C.-Y., Chuang, F.-Y., & Sun, C. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0060 · Cited by 3
“To determine clinical validity of the parameters, the criteria of within-subject biological variation (CVw) [6] that defined the acceptable values of CVw for the parameters of CBC as white blood cell count (WBC) < 10.”
MethodEvaluation of biological variations in glucose and glycated hemoglobin levels in healthy individuals
Coşkun, C., Inal, B. B., Emre, H. Ö., Baz, Ş., Gümüş, A., Sönmez, D., Orhan, B., Düz, M. E., Serin, E., & Koldaş, M. (2017) · Turkish Journal of Biochemistry · doi:10.1515/tjb-2017-0165 · Cited by 3
“[12, 23] and published online on the Westgard website, whereas they were fairly consistent with the results presented in another study of Ricos et al.”
MethodResultChovelon, B., & Arnaud, J. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0833 · Cited by 3
Routine coagulation testing in Vacutainer ® Citrate Plus tubes filled at minimum or optimal volume
Balboni, F., Barbui, S., Gallo, M., Berardi, M., Vezzosi, M., & Lippi, G. (2019) · Diagnosis · doi:10.1515/dx-2019-0052 · Cited by 3
“This difference was comprised within the current quality specifications [19, 20].”
BackgroundInfluentialKur, D. K., Hillig, T., Hansen, S. I., Goharian, T. S., Witte, M. L., & Thode, J. (2020) · The Journal of Applied Laboratory Medicine · doi:10.1093/jalm/jfaa006 · Cited by 3
Use of « Reference change value » in medical biology: about two examples: total PSA and hemoglobin
Bouverot, C., Blachier, S., Roquigny, N., & Guerber, F. (2020) · Annales de biologie clinique · doi:10.1684/abc.2020.1588 · Cited by 3
Frugier, A., Malcus, C., Baume, M., Poitevin‐Later, F., Lukaszewicz, A., Venet, F., Monneret, G., & Gossez, M. (2022) · Annales de biologie clinique · doi:10.1684/abc.2022.1715 · Cited by 3
Allowable systematic difference between two instruments measuring the same analyte
Åsberg, A., Solem, K. B., & Mikkelsen, G. (2015) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2015.1057900 · Cited by 3
Estimated Glomerular Filtration Rate
Delanaye, P., Cavalier, E., & Krzesinski, J.-M. (2007) · Annals of Internal Medicine · doi:10.7326/0003-4819-146-1-200701020-00020 · Cited by 3
“The intra-individual CV of serum creatinine is 4% (3).”
BackgroundQuality aspects of long-term stored samples : Studies in the Janus Serum Bank of Norway
Gislefoss, R. E. (2010) · NORA - Norwegian Open Research Archives · Cited by 3
Selected markers of bone biochemistry
Palička, V., Jabor, A., Friedecky, B., & Zivny, P. (2001) · Advances in clinical chemistry · doi:10.1016/s0065-2423(01)35018-7 · Cited by 3
Danilov-Danil’yan, V. I., & Rosental, O. M. (2023) · Ecology and Industry of Russia · doi:10.18412/1816-0395-2023-11-66-71 · Cited by 2
Sigma metrics as quality indicators in guiding and tracking laboratory process improvement
Sengupta, S., Chung, D. W., Kumar, R., Gupta, P., Upadhyay, S., & Rattan, A. (2023) · International Journal of Research in Medical Sciences · doi:10.18203/2320-6012.ijrms20233837 · Cited by 2
VitalOne™: a point-of-care platform for rapid, comprehensive, central-lab quality blood testing
Koussa, M. A., Barreiros, M., Perez, P. S. E., Jean, S. R., Lee, T. C., MacLeod, R., Witham, A., Bhat, G., Campbell, T., Lizano, S., et al. (2024) · Sensors & Diagnostics · doi:10.1039/d4sd00105b · Cited by 2
Comparability of the LDH measurement and analysis based on external quality assessment
Zhao, G., Wang, N., Zhang, R., & Zhang, S. (2025) · Clinica Chimica Acta · doi:10.1016/j.cca.2025.120157 · Cited by 2
V‐ PRO Blood Collection Tubes: Validation for Clinical Chemistry and Immunoassay Tests
Borai, A., Alsharif, W., Alhindi, A., Alqahtani, M., Elsayid, M., Khalil, H., Marwani, S. A., Yagoot, A., Magjacot, J., Meteiri, M. A., et al. (2025) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.70007 · Cited by 2
Patient based real time quality control using average of normal approach
Shaikh, S. (2025) · International journal of medical biochemistry/International journal of medical biochemistry : · doi:10.14744/ijmb.2025.25901 · Cited by 2
Data analytics for error detection in clinical laboratories
Chan, C. W. (2025) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2025.2555261 · Cited by 2
Stability of complete blood count parameters in low volume tubes under different storage conditions
Caniklioğlu, A., & Akbulut, E. D. (2025) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2025.2569834 · Cited by 2
Salvatici, M., Carreras, F., Gaimarri, M., Sansico, D. F., Marinoni, P., Masserini, C., Bianchi, B., Sommese, C., & Drago, L. (2025) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2025.e00515 · Cited by 2
Acquisition and interpretation of biochemical data
Bruce, H., & Lapsley, M. (2014) · Elsevier eBooks · doi:10.1016/b978-0-7020-5140-1.00002-x · Cited by 2
Improper coverage factor to compare expanded uncertainty with allowable total error
Çubukçu, H. C. (2018) · Turkish Journal of Biochemistry · doi:10.1515/tjb-2018-0245 · Cited by 2
Tanney, K., Mahaveer, A., Dockery, K., Booth, N., Chadwick, C. A., Chaloner, C., & Rajai, A. (2018) · Acta Paediatrica · doi:10.1111/apa.14653 · Cited by 2
Bellio, P., Angelis, S. D., Piccirilli, A., Michele, G. D., Barnabei, R., Amicosante, G., Perilli, M., & Celenza, G. (2022) · Diagnostics · doi:10.3390/diagnostics13010085 · Cited by 2
Comparison of five different plasma homocysteine assays in routine analysis
Bianchi, V., Lanati, A., Martino, F., Piccinini, S., Pinca, A., Sida, G., Demicheli, M. S. A., Arfini, C., & Vidali, M. (2012) · Clinica Chimica Acta · doi:10.1016/j.cca.2012.06.027 · Cited by 2
Analytical imprecision of lactate dehydrogenase in primary serum tubes
Buonocore, R., Avanzini, P., Aloe, R., & Lippi, G. (2015) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563215595644 · Cited by 2
“3%).(6) All subjects provided a written consent for enrollment in the study, which was approved by the Institutional Review Board and carried out according to the Declaration of Helsinki.”
MethodComparison of small-volume tubes with vacuum blood tubes for complete blood count
Ünal, K. (2019) · International journal of medical biochemistry/International journal of medical biochemistry : · doi:10.14744/ijmb.2019.69188 · Cited by 2
“The observed differences were clinically significant since the mean difference at baseline for RBC, HGB, HCT, MCH, MCHC, PLT, and BASO exceeded the current desirable quality specifications [9].”
BackgroundTiroid Fonksiyon testlerinin analitik performansının değerlendirilmesinde; 6 sigma metodolojisi
Ercan, M., & Kirmit, A. (2019) · Harran Üniversitesi Tıp Fakültesi Dergisi · doi:10.35440/hutfd.598537 · Cited by 2
Yu, W. Z., Liu, Q., Leung, H. W., Tong, B. M. K., Chew, G., Lee, T. K., Shin, R. Y. C., Teo, T. L., & Sethi, S. K. (2021) · Journal of Trace Elements in Medicine and Biology · doi:10.1016/j.jtemb.2021.126825 · Cited by 2
Kalaria, T., Fenn, J. S., Whitmill, R., Ford, C., & Gama, R. M. (2022) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/00045632211066275 · Cited by 2
“6% for serum urate was used in the RCV calculation.(14)”
MethodQuality Management and Accreditation
Mortimer, D., Björndahl, L., Barratt, C. L. R., Castilla, J. A., Menkveld, R., Kvist, U., Álvarez, J. G., & Haugen, T. B. (2022) · Cambridge University Press eBooks · doi:10.1017/9781009181648.012 · Cited by 2
Multicentre evaluation of a new point-of-care test for the determination of CK-MB in whole blood
Giannitsis, E., Baum, H. H. E., Bertsch, T., Juchum, M., Müller-Bardorff, M., Jørgensen, B., Böhmer, A., Rebmann, M., Schäffler, J., Schwab, M. G., et al. (2008) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2008.127 · Cited by 2
“for the bias in measuring CK-MB mass (31).”
BackgroundAziz, N., Gjertson, D. W., Mimiaga, M. J., Azarkman, C. D., Soto, R., Alexopoulos, N., & Detels, R. (2022) · Lipids in Health and Disease · doi:10.1186/s12944-022-01668-0 · Cited by 2
Hidalga, P. R., Bautista, C. D., Fernández, R. M. S., Bedini, J. L., & Rico, N. (2023) · Advances in Laboratory Medicine / Avances en Medicina de Laboratorio · doi:10.1515/almed-2022-0074 · Cited by 2
Guillaume, L., Chapelle, V., Deltombe, M., Nevraumont, A., Mairesse, A., Maisin, D., & Gruson, D. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-0966 · Cited by 2
Stability of ten serum tumor markers after one year of storage at −18°C
Mondésert, E., Brauwere, D.-P. D., Lumbroso, S., Brouillet, J., & Bancal, C. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2023-1312 · Cited by 2
Colorimetric correcting for sample concentration in stool samples
Delanghe, J., Elslande, J. V., Godefroid, M., Barroso, A. M. T., Buyzere, M. D., & Maenhout, T. M. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2024-0961 · Cited by 2
“In human body fl uids, biological variation of bilirubin is moderate [19], which warrants a stable catabolic rate.”
Blondé-Cynober, F., & Aussel, C. (2010) · Bio Tribune Magazine · doi:10.1007/s11834-010-0012-x · Cited by 2
Une expérience pratique d’accréditation en hématologie
Marion, S. (2010) · Revue Francophone des Laboratoires · doi:10.1016/s1773-035x(10)70384-1 · Cited by 2
Plebani, M. (2006) · Accreditation and Quality Assurance · doi:10.1007/s00769-006-0122-z · Cited by 2
Effect of uncertainty components such as recalibration on the performance of quality control charts
Winkel, P., & Zhang, N. F. (2005) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/0036551050035248 · Cited by 2
“Coefficient of variation (CV) when the variance component due to reagent group is included (B) and CV when the variance component is not included (A), percent decrease in CV obtained by including the factor due to the reagent group (C) and desirable CV according to [15] (D).”
Siloaho, M., Linko, S., Puhakainen, E., & Nordberg, U.-R. (2006) · Accreditation and Quality Assurance · doi:10.1007/s00769-006-0148-2 · Cited by 2
Biological variation of non-SI traceable biological quantities: example of proteins
Fuentes‐Arderiu, X. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.268 · Cited by 2
“In fact, until now, the information on biological variation of non-SI traceable quantities published as banks of data corresponds to the mean or median of biological variation data from different studies using different immunochemical measurement procedures (4, 5).”
BackgroundTenor, D. P., Cabezas-Martínez, Á., Gómez, J. C., Esteban, R. O., Zapata, J. T., Mendieta, E. J. L., & Reus, M. G.-S. (2012) · Revista del Laboratorio Clínico · doi:10.1016/j.labcli.2012.04.003 · Cited by 2
Sierink, J. C., Joosse, P., de Castro, S. M. M., Schep, N. W. L., & Goslings, J. C. (2014) · International Journal of Emergency Medicine · doi:10.1186/s12245-014-0026-3 · Cited by 2
Studies on the Variation in Clinical Laboratory Data and Safety Evaluation of Pharmaceuticals
野村, 守., Hata, T., Naitoh, S., KUWAO, H., Moriyama, K., Fukuoka, M., Kudo, M., & Tohda, Y. (2005) · YAKUGAKU ZASSHI · doi:10.1248/yakushi.125.997 · Cited by 2
Baumert, J. J., Karakas, M., Greven, S., Rückerl, R., Peters, A., & Köenig, W. (2012) · Thrombosis and Haemostasis · doi:10.1160/th11-10-0703 · Cited by 2
Using the hazard ratio to evaluate allowable total error in predictive measurands
Åsberg, A., Odsæter, I. H., Mikkelsen, G., & Hov, G. G. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0901 · Cited by 2
“65 times allowable imprecision [11] may be mathematically justified, but is strange considering that allowable imprecision was derived under the premise of no change in bias [10].”
BackgroundMethodInfluentialvan Deventer, H. E., Miller, W. G., Myers, G. L., Sakurabayashi, I., Bachmann, L. M., Caudill, S. P., Dziekoński, A., Edwards, S. H., Kimberly, M. M., Korzun, W. J., et al. (2011) · Redalyc (Universidad Autónoma del Estado de México) · Cited by 2
van der Hagen, E. A. E., Smeekens, K. C. J., Veer, N. E. V. ‘., Boonen, K. J. M., & Ermens, A. A. M. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0890 · Cited by 2
Arboleya, Z. C., & Venta, R. (2014) · Revista del Laboratorio Clínico · doi:10.1016/j.labcli.2014.07.001 · Cited by 2
Development of a novel, hemolysis-resistant reagent for assessment of α-amylase in biological fluids
Ronda, L., Mozzarelli, A., Aloe, R., & Lippi, G. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0376 · Cited by 2
Rin, G. D., & Lippi, G. (2014) · SLAS TECHNOLOGY · doi:10.1177/2211068214536048 · Cited by 2
Ítalo Moisés Saldaña, O. (2014) · Anales de la Facultad de Medicina · doi:10.15381/anales.v75i3.9776 · Cited by 2
Muller, W., Gouka-Tseng, C., Dollahmoersid, R., Witteveen, C., & Vroonhof, K. (2007) · Cited by 2
Hemostasis Test Compatibility with Capped and Uncapped Tubes
Finnegan, K., & Cutsforth, G. A. (2011) · American Society for Clinical Laboratory Science · doi:10.29074/ascls.24.4.215 · Cited by 2
“6%.(7) This relatively large variation also incorporates the role of fibrinogen as an acute phase reactant.”
BackgroundInfluentialSperm concentration measurement with a disposable counting chamber
Patrat, C., Lemoine, M., Ferraretto, X., Royer, M.-A.-D., Benammar, A., Darolles, J., Epelboin, S., & Eustache, F. (2018) · Asian Journal of Andrology · doi:10.4103/aja.aja_72_17 · Cited by 2
Buthelezi, E. P., Marule, F., Motlonye, B., Mopane, N., Rakhothule, T., & Tanyanyiwa, D. M. (2019) · Pathology and Laboratory Medicine · doi:10.11648/j.plm.20190301.13 · Cited by 2
“The analytical imprecision (CVa), using formula ACL = 2.77 CVa.”
ResultInfluentialIrvine, K. L., Mans, C., & Friedrichs, K. R. (2019) · Journal of Avian Medicine and Surgery · doi:10.1647/2018-374 · Cited by 2
Zhang, R., Zhang, S., & Wang, Q. (2021) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2020.1855469 · Cited by 2
Krasztel, M. M., Czopowicz, M., Szaluś‐Jordanow, O., Moroz, A., Mickiewicz, M., & Kaba, J. (2021) · Animals · doi:10.3390/ani11113172 · Cited by 2
Monneret, D., Devilliers, C., & Bonnefont‐Rousselot, D. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0333 · Cited by 2
“8%) [9], and to analytical imprecision (CV = 5.”
BackgroundArnaud, J., Weykamp, C. W., Wenzel, R., Patriarca, M., González-Estecha, M., Janssen, L., Fofou‐Caillierez, M. B., Alemany, M. V., Patriarca, V., de Graaf, I., et al. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2024-0551 · Cited by 2
Salgueiro, J. S. (2016) · Digital Library of Theses and Dissertations (Universidade de São Paulo) · doi:10.11606/d.9.2016.tde-22122015-092807 · Cited by 2
Real change or natural fluctuation? Linking laboratory results to clinical practice
Hilderink, J. M., Koopmans, R. P., Rennenberg, R. J. M. W., van Dieijen-Visser, M. P., & Meex, S. J. R. (2021) · Research Publications (Maastricht University) · doi:10.26481/dis.20210330jh · Cited by 2
Method Development and Validation of Vitamin D2 and Vitamin D3 using Mass Spectrometry
Riley, D. V. (2016) · ResearchWorks at the University of Washington (University of Washington) · Cited by 2
Quality Control in Laboratory Medicine
Strike, P. W. (2014) · Wiley eBooks · doi:10.1002/9781118445112.stat05473 · Cited by 2
Sample stability for routine coagulation testing
Favaloro, E. J., Mohammed, S., & Lippi, G. (2020) · Thrombosis Research · doi:10.1016/j.thromres.2020.08.025 · Cited by 2
Glucose(monitoring): from bench to real world experiences
Fokkert, M. J. (2022) · University of Groningen research database (University of Groningen / Centre for Information Technology) · doi:10.33612/diss.207217778 · Cited by 2
Yim, J., Rim, J. H., Lim, Y. K., Cho, Y., Park, Y., Kim, S., & Yun, Y.-M. (2023) · Laboratory Medicine Online · doi:10.47429/lmo.2023.13.4.255 · Cited by 1
Ko, D., Lee, S. W., Hyun, J., Kim, H. S., Park, M.-J., & Shin, D. H. (2017) · Clinica Chimica Acta · doi:10.1016/j.cca.2017.11.035 · Cited by 1
Aboulmakarim, S., Benbella, A., Hardizi, H., Zaidouni, A., & Bezad, R. (2018) · Revue Francophone des Laboratoires · doi:10.1016/s1773-035x(18)30050-9 · Cited by 1
Evaluation of Analytical Quality of Cardiac Biomarkers in the Emergency Laboratory by Sigma Metric
Kader, S. (2019) · International Journal of Scientific and Technological Research · doi:10.7176/jstr/5-9-05 · Cited by 1
“3 Allowable total error (TEa) The sigma metrics were calculated using TEa goals from one source in order to understand the effect of TEa on estimates of Sigma metrics: the Desirable Biological Variation Database (15).”
MethodInfluentialBiological variables and their potential impact on biomarkers and precision medicine initiative
Halim, A. B. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816121-0.00008-8 · Cited by 1
Three-year monitoring and comparison of results from two identical blood gas analyzers
Yun, H., Dean, R., Dubbelman, Y., Vincent, A., & Chan, Y.-P. M. (2022) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2022.e00286 · Cited by 1
Arterial pCO2 prediction using saphenous pCO2 in healthy mechanically ventilated dogs
Ghilardi, S., Gamba, D., Zanaboni, A. M., Brambilla, P., Casarrubea, A., Drummer, P., Balsamino, M., Ghezzi, D., Ricci, C., Caristi, D., et al. (2024) · Frontiers in Animal Science · doi:10.3389/fanim.2023.1291233 · Cited by 1
Koffi, A. J., Francisk, K., Charlotte, K., Karna, Y., Ahiboh, H., & Hauhouot-Attoungbré, M. L. (2024) · Journal of Analytical Sciences Methods and Instrumentation · doi:10.4236/jasmi.2024.141002 · Cited by 1
Wiwe, E. F., Schmidt, L. E., Zeuthen, E., Engelstoft, I. M. S., Christiansen, B. B., Hansen, T. S., Burkhardt, M. A., & Jensen, C. A. J. (2024) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.14291 · Cited by 1
Data science applied to the assessment of biological variation estimates
Marqués-García, F., Librero, A. B. N., García, N. G., Tejedor-Ganduxé, X., & Martinez-Bravo, C. (2025) · Advances in Laboratory Medicine / Avances en Medicina de Laboratorio · doi:10.1515/almed-2025-0042 · Cited by 1
Vo, N. N., Tran, H. T., Le, T. T., Nguyen, T. H. P., Vu, D. D., Thai, M. T., & Nguyen, T. T. P. (2025) · PLoS ONE · doi:10.1371/journal.pone.0330292 · Cited by 1
Validation study of the Helena V8 UltraCE capillary elecrophoresis analyser
Delanghe, J., Godefroid, M., & Maenhout, T. M. (2026) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2025-1523 · Cited by 1
“This result is excellent, as compared with earlier published reports presenting CVs 10 % for capillary electrophoresis systems [17], and well below the total error limits based on biological variation [18].”
Ruhaak, L. R., Kuklenyik, Z., Dittrich, J., Dantuma, E., Romijn, F. P. H. T. M., Diederiks, N. M., Deprez, L., Hoofnagle, A. N., Vesper, H. W., Ceglarek, U., et al. (2026) · Clinical Chemistry · doi:10.1093/clinchem/hvag020 · Cited by 1
Védrenne, A., Habarou, F., Pascreau, T., & Vasse, M. (2026) · Journal of Clinical Medicine · doi:10.3390/jcm15124607 · Cited by 1
“Lastly, the MRB values observed for some parameters were only marginal, within the range of test variability and below the desirable or optimal Ricos’s specifications [11].”
Zhu, X.-Y., Li, W., Pan, X.-Y., Li, T., & Yuan, G. (2026) · Scientific Reports · doi:10.1038/s41598-026-57057-5 · Cited by 1
Castillo, N. O., Barallat, J., Macias, Y. A., Morales‐Indiano, C., Doladé, M., & Granada, M. L. (2009) · Revista del Laboratorio Clínico · doi:10.1016/j.labcli.2009.06.001 · Cited by 1
Badiou, S., Cournil, A., Toubal, S., Bargnoux, A., Dupuy, A., Fernandez, C., Peyrière, H., Reynes, J., & Cristol, J. (2015) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2015.01.002 · Cited by 1
“In all groups, CVg was higher than previous data reported in healthy volunteers [7] or active subjects [8] but closed to values observed in renal transplant patients [4].”
Resultvan Deventer, H. E., Miller, W. G., Myers, G. L., Sakurabayashi, I., Bachmann, L. M., Caudill, S. P., Dziekoński, A., Edwards, S. H., Kimberly, M. M., Korzun, W. J., et al. (2011) · Laboratory Medicine Online · doi:10.3343/lmo.2011.1.3.1 · Cited by 1
Towards Performing Internal Quality-Control (IQC) Parameters in Clinical Laboratory
Najafi, M. (2013) · Advanced Techniques in Biology & Medicine · doi:10.4172/2379-1764.1000105 · Cited by 1
13. Point-of-Care Creatinine Testing in High-Risk Patients.
de Rijke, Y. B. (2009) · PubMed Central · Cited by 1
Allowable bias derived from the NOBIDA reference values
Åsberg, A., & Odsæter, I. H. (2019) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2019.1669219 · Cited by 1
“For comparison are shown the figures (recalculated) from the original publication of the reference limits of the NOBIDA database [9] (NORIP), from the EuBIVAS project [4,11–13], and the figures in the online database of the Spanish Society of Clinical Biochemistry and Molecular Pathology (SEQC) [14].”
BackgroundMethodResultInfluentialde Rancher, M.-A. R., Chenevier‐Gobeaux, C., Lemaréchal, H., Alkouri, R., Borderie, D., Bonnefont‐Rousselot, D., & Monneret, D. (2019) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2019.1672087 · Cited by 1
“2% [8,9], while the recent EuBIVAS proposed a lower CVI at 7.”
BackgroundTEST REPETITION FROM THE VIEWPOINT OF BIOLOGICAL VARIATION
Çubukçu, H. C. (2021) · Acibadem Universitesi Saglik Bilimleri Dergisi · doi:10.31067/acusaglik.1023238 · Cited by 1
“Random analytical error, bias, and total error of clinical laboratories can easily be compared with these goals to ensure laboratories’ compatibility (4).”
Background
Metadata
- Authors
- C. Ricós, V. A.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1999-01
- Volume
- 59
- Issue
- 7
- Pages
- 491-500
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2119950421
- Cited by
- 987
- References
- 6
- Citations by year
- 2026: 17 · 2025: 25 · 2024: 22 · 2023: 29 · 2022: 41 · 2021: 44 · 2020: 47 · 2019: 51 · 2018: 64 · 2017: 69 · 2016: 58 · 2015: 46 · 2014: 76 · 2013: 56 · 2012: 55
- FWCI
- 5.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Scandinavian Journal of Clinical and Laboratory Investigation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- biological variation, reference values, clinical laboratory testing, within-subject coefficient of variation, total error, bias and precision, disease states, hormones
- MeSH terms
- Humans, Quality Control, Clinical Laboratory Techniques, Databases as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.