Current databases on biological variation: pros, cons and progress
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A database with reliable information to derive definitive analytical quality specifications for a large number of clinical laboratory tests was prepared in this work. This was achieved by comparing and correlating descriptive data and relevant observations with the biological variation information, an approach that had not been used in the previous efforts of this type. The material compiled in the database was obtained from published articles referenced in BIOS, CURRENT CONTENTS, EMBASE and MEDLINE using "biological variation & laboratory medicine" as key words, as well as books and doctoral theses provided by their authors. The database covers 316 quantities and reviews 191 articles, fewer than 10 of which had to be rejected. The within- and between-subject coefficients of variation and the subsequent desirable quality specifications for precision, bias and total error for all the quantities accepted are presented. Sex-related stratification of results was justified for only four quantities and, in these cases, quality specifications were derived from the group with lower within-subject variation. For certain quantities, biological variation in pathological states was higher than in the healthy state. In these cases, quality specifications were derived only from the healthy population (most stringent). Several quantities (particularly hormones) have been treated in very few articles and the results found are highly discrepant. Therefore, professionals in laboratory medicine should be strongly encouraged to study the quantities for which results are discrepant, the 90 quantities described in only one paper and the numerous quantities that have not been the subject of study.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, the characteristics of the populations studied in the papers included in the historical estimates varied and include diseased (uncomplicated myocardial infarction, liver disease, type 1 diabetes mellitus) and non-diseased subjects [12, 16].”
From The European Biological Variation Study (EuBIVAS): a summary report (2022) · cites this paper as [12]
Citations
Cites
Generation and Application of Data on Biological Variation in Clinical Chemistry
Fraser, G. G., & Harris, E. K. (1989) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408368909106595 · Cited by 870
Fraser, C. G., Petersen, P. H., Ricós, C., & Haeckel, R. (1992) · PubMed · Cited by 125
The application of theoretical goals based on biological variation data in proficiency testing.
Cg, F. (1988) · PubMed · Cited by 119
(1997) · PubMed · Cited by 102
Biological variation in clinical chemistry. An update: collated data, 1988-1991.
Fraser, C. G. (1992) · PubMed · Cited by 91
The "index of fiduciality" proposed for use in evaluation and comparison of methods.
Fraser, C. G., & Browning, M. C. (1988) · Clinical Chemistry · doi:10.1093/clinchem/34.6.1356 · Cited by 13
Research works printed but not linked: 3
- Fraser CG, 1988, Arch Pathol Lab Med, 112, 404
- Fraser CG, 1992, Collated data, 1988-1991. Arch Pathol Lab Med, 116, 916
- Fraser CG, 1992, Eur J Clin Chem Clin Biochem, 30, 311
Cited by
Items 301–400 of 1,000
Laboratory Tests in Diagnosis and Management of Diabetes Mellitus. Practical Considerations
Miedema, K. (2003) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2003.193 · Cited by 31
Zhou, R., Liang, Y.-F., Cheng, H.-L., Wang, W., Huang, D.-W., Wang, Z., Feng, X., Han, Z.-W., Song, B., Padoan, A., et al. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-1171 · Cited by 28
“RCV limits of each test item dependent on biological variability (BV) [14] were estimated using the following formula: Coverage factor K was varied from 1.5 to 3.3 in steps of 0.1, coef fi cient of variation ( CV a ) was analytical imprecision, and CV i was within-subject BV. CV a was calculated…”
MethodInfluentialBlood Glucose Determination: Effect of Tube Additives
(2018) · Advances in Clinical Chemistry · doi:10.1016/bs.acc.2017.12.003 · Cited by 28
No influence of a butterfly device on routine coagulation assays and D‐dimer measurement
LIPPI, G., SALVAGNO, G. L., & GUIDI, G. C. (2005) · Journal of Thrombosis and Haemostasis · doi:10.1111/j.1538-7836.2005.01163.x · Cited by 28
Internal quality control – past, present and future trends
Ricós, C., Fernández–Calle, P., Perich, C., & Westgard, J. O. (2022) · Advances in Laboratory Medicine / Avances en Medicina de Laboratorio · doi:10.1515/almed-2022-0029 · Cited by 30
“This new database has been created from an exhaustive revision of papers included in the first database [19, 20] as well as from the application of an effective bibliographic search, able to recover as many as BV papers possible.”
MethodWu, A. H. B., Ruan, W., Todd, J. A., & Lynch, K. L. (2014) · Clinica Chimica Acta · doi:10.1016/j.cca.2013.12.040 · Cited by 28
Lippi, G., Avanzini, P., Cosmai, M., Aloe, R., & Ernst, D. J. (2012) · British Journal of Biomedical Science · doi:10.1080/09674845.2012.12002439 · Cited by 28
Multicentre evaluation of a new point-of-care test for the determination of NT-proBNP in whole blood
Zugck, C., Nelles, M., Katus, H. A., Collinson, P. O., Gaze, D. C., Dikkeschei, B. D., Gurr, E., Hayen, W., Haass, M., Hechler, C., et al. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.215 · Cited by 28
Capillary Zone Electrophoresis of Serum Proteins: Effects of Changed Analytical Conditions
Luraschi, P., Dea, E. D., & Franzini, C. (2003) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2003.118 · Cited by 28
“The biological variation-based quality specifications for bias (22) for each electrophoretic zone were calculated taking mean published values (23, 24) for the intra- and inter-individual biological variation.”
MethodInfluence of posture on routine hemostasis testing
Lippi, G., Salvagno, G. L., Lima-Oliveira, G., Danese, E., Favaloro, E. J., & Guidi, G. C. (2015) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0000000000000326 · Cited by 27
Yin, Y., Ma, C., Yu, S., Liu, W., Wang, D., You, T., Cheng, Q., & Qiu, L. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-0706 · Cited by 27
Layssol‐Lamour, C., Sarry, J., Braun, J.-P. D., Trumel, C., & Bourgès-Abella, N. H. (2020) · Journal of the American Association for Laboratory Animal Science · doi:10.30802/aalas-jaalas-20-000020 · Cited by 27
Magnusson, B., Ossowicki, H., Rienitz, O., & Theodorsson, E. (2012) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2011.649015 · Cited by 27
Venipuncture Versus Peripheral Catheter: Do Infusions Alter Laboratory Results?
Lerma, V., Gómez, I. A., & Andreu, F. A. B. (2012) · Journal of Emergency Nursing · doi:10.1016/j.jen.2012.03.014 · Cited by 27
Sex steroid hormone stability in serum tubes with and without separator gels
Hepburn, S., Wright, M. J. P., Boyder, C., Sahertian, R. C., Lu, B., Zhang, R., White, C., & Horvath, A. R. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-1133 · Cited by 27
Technical and clinical validation of the Greiner FC-Mix glycaemia tube
van der Hagen, E. A. E., Fokkert, M. J., Kleefman, A. M. D., Thelen, M., van den Berg, S. A. A., & Slingerland, R. J. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0944 · Cited by 27
“5%), and is outlined in Figure 1B with dotted lines [1, 18, 19].”
BackgroundButtarello, M., Rauli, A., & Mezzapelle, G. (2017) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12705 · Cited by 27
Jansen, R., Cobbaert, C. M., Weykamp, C. W., & Thelen, M. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0796 · Cited by 27
Panteghini, M., Ceriotti, F., Pagani, F., Secchiero, S., Zaninotto, M., & Franzini, C. (2002) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2002.017 · Cited by 27
“9%; optimal imprecision: CV ≤3%) (14), it is evident that the assay has worked out with the established limit for its optimal clinical use.”
BackgroundEvaluation of sample hemolysis in blood collected by S-MonovetteR using vacuum or aspiration mode
Lippi, G., Avanzini, P., Musa, R., Sandei, F., Aloe, R., & Cervellin, G. (2013) · Biochemia Medica · doi:10.11613/bm.2013.008 · Cited by 27
Shaikh, M. S., & Moiz, B. (2016) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12468 · Cited by 27
“for TEa for each analyte were taken from large published database [7].”
MethodGuo, X., Hou, L., Cheng, X., Zhang, T., Yu, S., Fang, H., Xia, L., Qi, Z., Qin, X., Zhang, L., et al. (2015) · Medicine · doi:10.1097/md.0000000000000905 · Cited by 27
“Based on the biological variations and recommendations from clinical experts, a deviation for the Cr concentration of 4% was considered clinically acceptable.(16)”
BackgroundCritical appraisal and meta-analysis of biological variation estimates for kidney related analytes
Jonker, N., Aslan, B., Boned, B., Marqués-García, F., Ricós, C., Alvarez, V., Bartlett, W., Braga, F., Carobene, A., Coskun, A., et al. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2020-1168 · Cited by 26
Analytical Performances of the Novel i-STAT Alinity Point-of-Care Analyzer
Larcher, R., Lottelier, M., Badiou, S., Dupuy, A., Bargnoux, A., & Cristol, J. (2023) · Diagnostics · doi:10.3390/diagnostics13020297 · Cited by 26
Peake, R. W. A., Law, T., Hoover, P. N., Gaewsky, L., Shkreta, A., & Kellogg, M. D. (2013) · Clinica Chimica Acta · doi:10.1016/j.cca.2013.03.036 · Cited by 26
Performance Evaluation of the Piccolo xpress Point-of-care Chemistry Analyzer
Park, H., Ko, D., Kim, J. Q., & Song, S. H. (2009) · Annals of Laboratory Medicine · doi:10.3343/kjlm.2009.29.5.430 · Cited by 26
Xia, J., Chen, S., Xu, F., & Zhou, Y. (2017) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.22284 · Cited by 26
da Cunha, N. P., Giordano, A., Caniatti, M., & Paltrinieri, S. (2009) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2008.00107.x · Cited by 26
Khuseyinova, N., Greven, S., Rückerl, R., Trischler, G., Loewel, H., Peters, A., & Köenig, W. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.093468 · Cited by 26
Panton, K. K., Mikkelsen, G., Irgens, W. Ø., Hovde, A. K., Killingmo, M. W., Øien, M. A., Thorsby, P. M., & Åsberg, A. (2019) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2019.1622031 · Cited by 25
Zierk, J., Baum, H. H. E., Bertram, A., Boeker, M., Buchwald, A., Cario, H., Christoph, J., Frühwald, M. C., Groß, H., Groening, A., et al. (2021) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2020-1371 · Cited by 25
Recommendations for the application and follow-up of quality controls in medical laboratories
Giannoli, J., Cohen, R., Vialle, J.-M., Vassault, A. J., Siest, J.-P., Scherrer, F., Portugal, H., Paris, M., Kuentz, M., Galinier, J.-L., et al. (2021) · Biochemia Medica · doi:10.11613/bm.2021.020501 · Cited by 25
Comparison of capillary and venous blood sampling for routine coagulation assays
Fliervoet, L. A. L., Groenestege, W. M. T., & Huisman, A. (2022) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2022.01.010 · Cited by 25
Petersen, P. H., & Klee, G. G. (2014) · Clinica Chimica Acta · doi:10.1016/j.cca.2014.04.002 · Cited by 25
Gawria, G., Tillmar, L., & Landberg, E. (2019) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.23060 · Cited by 25
Quality Control of Automated Cell Counters
Cembrowski, G. S., & Clarke, G. (2015) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2014.10.006 · Cited by 25
Analysis of reagent lot-to-lot comparability tests in five immunoassay items.
Kim, H. S., Kang, H. J., Whang, D. H., Lee, S. G., Park, M., Park, J., & Lee, K. M. (2012) · PubMed · Cited by 25
Mlinarić, A., Miloš, M., Herak, D. C., Fuček, M., Rimac, V., Zadro, R., & Rogić, D. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0402 · Cited by 25
“[9] database on biological variation and analytical imprecision calculated in the yearly method assessment.”
MethodEvaluation of different mixing procedures for K2 EDTA primary samples on hematological testing
Lippi, G., Salvagno, G. L., Montagnana, M., Banfi, G., & Guidi, G. C. (2007) · Laboratory Medicine · doi:10.1309/95r8a56bdn10auuh · Cited by 24
Homogeneización de los valores del perfil lipídico
Pedro‐Botet, J., Padial, L. R., Brotons, C., Esteban-Salán, M., García-Lerín, A., Pintó, X., Lekuona, I., & Ordóñez‐Llanos, J. (2017) · Clínica e Investigación en Arteriosclerosis · doi:10.1016/j.arteri.2017.12.001 · Cited by 24
Geens, T., Vertessen, F., Malfait, R., Deiteren, K., & Maes, M. (2014) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12295 · Cited by 24
“All parameters met the desirable criteria for imprecision of Ricos [6].”
BackgroundMethodInfluentialDupuy, A., Badiou, S., Daubin, D., Bargnoux, A. S., Magnan, C., Klouche, K., & Cristol, J. (2018) · Biochemia Medica · doi:10.11613/bm.2018.020902 · Cited by 24
“In previous studies, results obtained from BarricorTM tubes were compared to plasma separator tube (PST) or serum with (SST) or without gel barrier (3-6).”
BackgroundMethodGrant, R. P., & Rappold, B. A. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-816063-3.00005-0 · Cited by 24
Kocijančić, M., Cargonja, J., & Delic-Knezevic, A. (2014) · Biochemia Medica · doi:10.11613/bm.2014.039 · Cited by 24
“25 (CVw2 + CVg2)1/2 where the CVw is within-subject biological variation and CVg is the between-subject biological variation (17).”
BackgroundShephard, M. D. S. (2006) · Cited by 24
Shephard, M. D. S., Shephard, A. K., Watkinson, L., Mazzachi, B. C., & Worley, P. (2009) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2009.009045 · Cited by 24
Carey, R. N., Jani, C. M., Johnson, C., Pearce, J., Hui-Ng, P., & Lacson, E. K., Jr. (2016) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.09310915 · Cited by 24
Zahoor, N., Danilenko, U., & Vesper, H. W. (2018) · Clinical mass spectrometry · doi:10.1016/j.clinms.2018.11.002 · Cited by 24
Serum calcium and tumour aggressiveness in breast cancer: a prospective study of 7847 women
Almquist, M., Anagnostaki, L., Bondeson, L., Bondeson, A., Borgquist, S., Landberg, G., Malina, J., Malm, J., & Manjer, J. (2009) · European Journal of Cancer Prevention · doi:10.1097/cej.0b013e32832c386f · Cited by 24
“Both short-term (Ricos et al., 1999) and long-term (Gallagher et al.”
BackgroundFriedrich, N., Pietzner, M., Cannet, C., Thuesen, B. H., Hansen, T., Wallaschofski, H., Grarup, N., Skaaby, T., Budde, K., Pedersen, O., et al. (2017) · PLOS ONE · doi:10.1371/journal.pone.0173078 · Cited by 23
“3% [13] updated every two years: https://www.”
Crawford, M. L., Collier, B. B., Bradley, M. N., Holland, P. L., Shuford, C. M., & Grant, R. P. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvaa082 · Cited by 23
Fatness, fitness, and cardiometabolic risk factors in middle-aged white men
O’Donovan, G., Kearney, E. M., Sherwood, R. A., & Hillsdon, M. M. (2011) · Metabolism · doi:10.1016/j.metabol.2011.06.009 · Cited by 23
“The within-subject variation in blood-borne cardiometabolic risk factors is considerable [14], so we took blood on 2”
BackgroundInfluentialA new turbidimetric method for assaying serum C-reactive protein based on phosphocholine interaction
Tugirimana, P. L., Holderbeke, A. L., Kint, J. A., & Delanghe, J. (2009) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2009.312 · Cited by 24
Reticulocytes in athletes: Longitudinal aspects and the influence of long‐ and short‐term exercise
Schumacher, Y. O., Sahm, D. F., Baumstark, M. W., & Pottgießer, T. (2010) · Drug Testing and Analysis · doi:10.1002/dta.180 · Cited by 23
Lima-Oliveira, G., Salvagno, G. L., Danese, E., Brocco, G., Guidi, G. C., & Lippi, G. (2014) · Biochemia Medica · doi:10.11613/bm.2014.038 · Cited by 21
Analyte stability during the total testing process: studies of vitamins A, D and E by LC-MS/MS
Albahrani, A. A., Rotarou, V., Roche, P. J., & Greaves, R. F. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-1034 · Cited by 23
Biologic Variation Approach to Daily Laboratory
Ricós, C., Álvarez, V., Minchinela, J., Fernández–Calle, P., Perich, C., Boned, B., González, E., Simón, M. S., Díaz–Garzón, J., García-Lario, J. V., et al. (2016) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2016.09.005 · Cited by 23
Tubular Acidification Defect in Adults with Sickle Cell Disease
Cazenave, M., Audard, V., Bertocchio, J., Habibi, A., Baron, S., Prot‐Bertoye, C., Berkenou, J., Maruani, G., Stehlé, T., Cornière, N., et al. (2019) · Clinical Journal of the American Society of Nephrology · doi:10.2215/cjn.07830719 · Cited by 23
“As previously reported (27), plasma HCO3(2) concentrations showed intraindividual variations that could be due to acute respiratory modifications.”
BackgroundQuality specifications for seminal parameters based on the state of the art
Castilla, J. A., Morancho‐Zaragoza, J., de Aguilar, J. V. S., Prats‐Gimenez, R., Gonzalvo, M. C., Fernández‐Pardo, E., Álvarez‐Nieto, C., Clar, R. C., & Martinez, L. (2005) · Human Reproduction · doi:10.1093/humrep/dei061 · Cited by 23
Point-of-care creatinine testing in children at risk for sudden deterioration of renal function
Schenk, P. W., Cransberg, K., Wolff, E. D., & de Rijke, Y. B. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.314 · Cited by 23
Commutability of Calibration and Control Materials for Serum Lipase
Cattozzo, G., Franzini, C., & d’Eril, G. M. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.12.2108 · Cited by 23
Hedberg, P. S. M., Majava, A., Kiviluoma, K. T., & Ohtonen, P. P. (2009) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510902878716 · Cited by 23
Detecting doping use: more than an analytical problem
Delanghe, J., Maenhout, T. M., Speeckaert, M. M., & Buyzere, M. D. (2014) · Acta Clinica Belgica · doi:10.1179/0001551213z.0000000009 · Cited by 23
Upper reference limit, analytical quality specifications and clinical use of haemoglobin A1C
Jørgensen, L. G. M., Brandslund, I., Stahl, M., Petersen, P. H., Iversen, S., Klitgaard, N. A., & Olivarius, N. D. F. (2002) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/003655102764654349 · Cited by 23
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Brocco, G., Gaino, S., Dima, F., Volaski, W., Rego, F. G., Picheth, G., & Guidi, G. C. (2014) · Biopreservation and Biobanking · doi:10.1089/bio.2013.0043 · Cited by 22
“…mean % differences from mixing procedures were compared with the current desirable quality specifications, derived from biological variation 27,28,29 according to the formula: where CV a is the percent analytical coefficient of variation, CV W is the within-subject biological variation, CV G…”
Utility and Necessity of Repeat Testing of Critical Values in the Clinical Chemistry Laboratory
Niu, A., Yan, X., Wang, L., Yan, M., & Hu, C. (2013) · PLoS ONE · doi:10.1371/journal.pone.0080663 · Cited by 22
Effect of preanalytical and analytical variables on the clinical utility of mean platelet volume
Buttarello, M., Mezzapelle, G., & Plebani, M. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0730 · Cited by 22
Variation in Laboratory Reports: Causes other than Laboratory Error
Pradhan, S., Gautam, K., & Pant, V. (2022) · Journal of Nepal Medical Association · doi:10.31729/jnma.6022 · Cited by 22
Detection of preanalytical errors in arterial blood gas analysis
ÇUHADAR, S., Özkanay, H., Köseoğlu, M., & Katırcıoğlu, K. (2022) · Biochemia Medica · doi:10.11613/bm.2022.020708 · Cited by 22
“and the Royal College of Pathologists of Australasia (RCPA) for allowable total error (17,18).”
BackgroundApplying Sigma Metrics to Reduce Outliers
Litten, J. (2016) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2016.09.014 · Cited by 22
IMPORTANCE OF THE PRE-ANALYTICAL PHASE IN BLOOD GLUCOSE ANALYSIS
Janssen, K., & Delanghe, J. (2010) · Acta Clinica Belgica · doi:10.1179/acb.2010.068 · Cited by 22
“The National Academy of Clinical Biochemistry (NACB) has proposed quality criteria for laboratory glucose analysis based on intra-individual biological variation (46) with a maximum allowable imprecision (CV) of ≤ 3.”
MethodEvaluation of Imprecision, Bias and Total Error of Clinical Chemistry Analysers
Biswas, S. S., Bindra, M., Jain, V., & Gokhale, P. (2014) · Indian Journal of Clinical Biochemistry · doi:10.1007/s12291-014-0448-y · Cited by 22
“[8] built the biodatabase of these desirable specifications, which are periodically updated on Westgard’s website [9].”
BackgroundMulticentre performance evaluation of the E170 Module for MODULAR ANALYTICS
Bieglmayer, C., Chan, D. W., Sokoll, L. J., Imdahl, R., Kobayashi, M., Yamada, E., Lilje, D. J., Luthe, H., Meissner, J., Messeri, G., et al. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.239 · Cited by 22
“A similar assessment was achieved when comparing the E170 total precision results with proposed quality specifications based on biological variation (11) (Table 6).”
MethodResultInfluentialStraseski, J. A., & Strathmann, F. G. (2012) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2012.11.009 · Cited by 21
K3EDTA Vacuum Tubes Validation for Routine Hematological Testing
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Poli, G., Solero, G. P., Picheth, G., & Guidi, G. C. (2012) · ISRN Hematology · doi:10.5402/2012/875357 · Cited by 21
Candidate reference method for determination of vitamin D from dried blood spot samples
Zakaria, R., Allen, K. J., Koplin, J. J., Roche, P. J., & Greaves, R. F. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-0397 · Cited by 21
Optimizing moving average control procedures for small-volume laboratories: can it be done?
Lukić, V., & Ignjatović, S. (2019) · Biochemia Medica · doi:10.11613/bm.2019.030710 · Cited by 21
Fasano, T., Bedini, J. L., Fle, P.-A., Jlaiel, M., Hubbert, K., Datta, H. K., Chicha-Cattoir, V., Mansour, H., Mira, Á., de la Presa, B. G., et al. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-0699 · Cited by 21
Patriarca, M., Barlow, N. L., Cross, A., Hill, S., Robson, A. F., & Tyson, J. F. (2023) · Journal of Analytical Atomic Spectrometry · doi:10.1039/d3ja90008h · Cited by 21
Salvador, C. L., Tøndel, C., Mørkrid, L., Bjerre, A. K., Brun, A., Bolann, B. J., Brackman, D., & Bergan, S. (2015) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2015.1091091 · Cited by 21
Acceptable “Real‐Life” Variability for Lymphocyte Counts by Flow Cytometry
Ticchioni, M., Brouzes, C., Durrieu, F., & Lambert, C. (2018) · Cytometry Part B Clinical Cytometry · doi:10.1002/cyto.b.21751 · Cited by 21
“com) following James Westgard’s initiative to define decision rules (5,6).”
BackgroundInfluentialWeekday variation in triglyceride concentrations in 1.8 million blood samples
Jaskolowski, J., Ritz, C., Sjödin, A., Astrup, A., Szecsi, P. B., Stender, S., & Hjorth, M. F. (2017) · Journal of Lipid Research · doi:10.1194/jlr.m074062 · Cited by 20
“An improved understanding of biological variation in clinically measured compounds in human material may be useful for many purposes in clinical chemistry (6).”
BackgroundThéron, M., Piane, L., Lucarelli, L., Henrion, R., Layssol‐Lamour, C., Palanché, F., Concordet, D., Braun, J.-P. D., Trumel, C., & Lavoué, R. (2017) · American Journal of Veterinary Research · doi:10.2460/ajvr.78.8.990 · Cited by 20
Effect of Blood Cell Subtypes Lysis on Routine Biochemical Tests
Ünlü, B., Küme, T., Emek, M., Örmen, M., Doğan, Y., Şişman, A. R., Ergör, G., & Çöker, C. (2017) · Journal of Medical Biochemistry · doi:10.1515/jomb-2017-0044 · Cited by 20
“The percent bias limits are from a large scaled database research that considers the between and within subjects biological variation and is made by »Ana ly tical Quality Commission from the Spanish Society of Clinical Chemistry and Molecular Pathology (SEQC)« (Table IV–V) (18).”
BackgroundAgreement and Correlation of Arterial and Venous Blood Gas Analysis in a Diverse Population
Chung, P. A., Scavone, A., Ahmed, A., Kuchta, K. M., & Bellam, S. K. (2019) · Clinical Medicine Insights Trauma and Intensive Medicine · doi:10.1177/1179560319845869 · Cited by 20
Cho, J., Seo, D. M., & Uh, Y. (2019) · Annals of Laboratory Medicine · doi:10.3343/alm.2020.40.3.201 · Cited by 20
Wu, Y., Lee, J. W., Uy, L., Abosaleem, B., Gunn, H., Ma, M., & Desilva, B. S. (2009) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2009.03.002 · Cited by 20
van Horssen, R., Schuurman, T. N., de Groot, M. J. M., & Jakobs, B. S. (2015) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2015.12.005 · Cited by 22
Mbasu, R. J., Heaney, L. M., Molloy, B. J., Hughes, C. J., Ng, L. L., Vissers, J. P. C., Langridge, J., & Jones, D. J. L. (2016) · PROTEOMICS · doi:10.1002/pmic.201500500 · Cited by 20
“The imprecision, bias, and total allowable error, calculated from data on within-subject and betweensubject biologic variation for clinical assays, including plasma proteins, have been populated in a database [47] (https:// www.”
MethodVitamins D and A can be successfully measured by LC–MS/MS in cord blood diluted plasma
Albarhani, A. A., Collier, F., Greaves, R. F., Ponsonby, A., Allen, K. J., Vuillermin, P., Roche, P. J., & Clarke, M. W. (2015) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2015.04.014 · Cited by 20
“Allowable total error (TEa) for vitamins A and E was taken from the Ricos Biological Variation database [13].”
MethodLima-Oliveira, G., Lippi, G., Salvagno, G. L., Dima, F., Brocco, G., Picheth, G., & Guidi, G. C. (2013) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12143 · Cited by 19
“PTS, pneumatic tube system; NA, not available [11].”
BackgroundSERUM CREATININE ASSAY: ENZYMATIC VS KINETIC JAFFE'S METHOD
Marakala, V., Avinash, S. S., & Shivashankara, A. (2012) · Journal of Evolution of Medical and Dental Sciences · doi:10.14260/jemds/54 · Cited by 19
Evaluation of capillary haemoglobin determination for anaemia screening in blood donation settings.
Daves, M., Cemin, R., Zagler, E. M., Joos, A., Platzgummer, S., Hueber, R., & Lippi, G. (2016) · Europe PMC (PubMed Central) · doi:10.2450/2016.0224-15 · Cited by 19
Rationale for using insensitive quality control rules for today’s hematology analyzers
Cembrowski, G. S., Smith, B., & TUNG, D. (2010) · International Journal of Laboratory Hematology · doi:10.1111/j.1751-553x.2010.01229.x · Cited by 19
Liver function testing on the Abaxis Piccolo Xpress: Use in Ebola virus disease protocols
Owen, W. E., Caron, J. E., & Genzen, J. R. (2015) · Clinica Chimica Acta · doi:10.1016/j.cca.2015.03.044 · Cited by 19
Brandhorst, G., Engelmayer, J., Götze, S., Oellerich, M., & von Ahsen, N. (2011) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2011.606 · Cited by 19
“Allowable differences were calculated considering the respective biological variation (10) by multiplying the maximum percent bias with the mean of the results from time point 0 h for each parameter, respectively.”
BackgroundMethodvan Dievoet, M., Louagie, H., & Ghys, T. (2016) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12522 · Cited by 19
“[3], were met for all parameters tested, except for platelets in the low level.”
BackgroundGreaves, R. F., Ho, C. S., Hoad, K., Joseph, J., McWhinney, B. C., Gill, J., Koal, T., Fouracre, C., Iu, H. P., Cooke, B. R., et al. (2016) · PubMed Central · Cited by 20
Nicolay, A., Lorec, A., Gomez, G., & Portugal, H. (2017) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.22229 · Cited by 19
Wittenmeier, E., Lesmeister, L., Pirlich, N., Dette, F. G., Schmidtmann, I. M., & Mildenberger, E. (2018) · Anaesthesia · doi:10.1111/anae.14481 · Cited by 19
“1%) was higher than that previously reported in pre-operative children [19] and higher than the required standard for a Hb measurement device [20].”
Result
Metadata
- Authors
- C. Ricós, V. A.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1999-01
- Volume
- 59
- Issue
- 7
- Pages
- 491-500
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2119950421
- Cited by
- 987
- References
- 6
- Citations by year
- 2026: 17 · 2025: 25 · 2024: 22 · 2023: 29 · 2022: 41 · 2021: 44 · 2020: 47 · 2019: 51 · 2018: 64 · 2017: 69 · 2016: 58 · 2015: 46 · 2014: 76 · 2013: 56 · 2012: 55
- FWCI
- 5.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Scandinavian Journal of Clinical and Laboratory Investigation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- biological variation, reference values, clinical laboratory testing, within-subject coefficient of variation, total error, bias and precision, disease states, hormones
- MeSH terms
- Humans, Quality Control, Clinical Laboratory Techniques, Databases as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.