Current databases on biological variation: pros, cons and progress
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A database with reliable information to derive definitive analytical quality specifications for a large number of clinical laboratory tests was prepared in this work. This was achieved by comparing and correlating descriptive data and relevant observations with the biological variation information, an approach that had not been used in the previous efforts of this type. The material compiled in the database was obtained from published articles referenced in BIOS, CURRENT CONTENTS, EMBASE and MEDLINE using "biological variation & laboratory medicine" as key words, as well as books and doctoral theses provided by their authors. The database covers 316 quantities and reviews 191 articles, fewer than 10 of which had to be rejected. The within- and between-subject coefficients of variation and the subsequent desirable quality specifications for precision, bias and total error for all the quantities accepted are presented. Sex-related stratification of results was justified for only four quantities and, in these cases, quality specifications were derived from the group with lower within-subject variation. For certain quantities, biological variation in pathological states was higher than in the healthy state. In these cases, quality specifications were derived only from the healthy population (most stringent). Several quantities (particularly hormones) have been treated in very few articles and the results found are highly discrepant. Therefore, professionals in laboratory medicine should be strongly encouraged to study the quantities for which results are discrepant, the 90 quantities described in only one paper and the numerous quantities that have not been the subject of study.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, the characteristics of the populations studied in the papers included in the historical estimates varied and include diseased (uncomplicated myocardial infarction, liver disease, type 1 diabetes mellitus) and non-diseased subjects [12, 16].”
From The European Biological Variation Study (EuBIVAS): a summary report (2022) · cites this paper as [12]
Citations
Cites
Generation and Application of Data on Biological Variation in Clinical Chemistry
Fraser, G. G., & Harris, E. K. (1989) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408368909106595 · Cited by 870
Fraser, C. G., Petersen, P. H., Ricós, C., & Haeckel, R. (1992) · PubMed · Cited by 125
The application of theoretical goals based on biological variation data in proficiency testing.
Cg, F. (1988) · PubMed · Cited by 119
(1997) · PubMed · Cited by 102
Biological variation in clinical chemistry. An update: collated data, 1988-1991.
Fraser, C. G. (1992) · PubMed · Cited by 91
The "index of fiduciality" proposed for use in evaluation and comparison of methods.
Fraser, C. G., & Browning, M. C. (1988) · Clinical Chemistry · doi:10.1093/clinchem/34.6.1356 · Cited by 13
Research works printed but not linked: 3
- Fraser CG, 1988, Arch Pathol Lab Med, 112, 404
- Fraser CG, 1992, Collated data, 1988-1991. Arch Pathol Lab Med, 116, 916
- Fraser CG, 1992, Eur J Clin Chem Clin Biochem, 30, 311
Cited by
Items 601–700 of 1,000
Development of an affordable dye-stained microalbuminuria screening test
Tugirimana, P. L., & Delanghe, J. (2008) · Nephrology Dialysis Transplantation · doi:10.1093/ndt/gfn705 · Cited by 9
“Although the reproducibility of the test is worse than the reproducibility of immunoturbidimetry or immunonephelometry [8], the reproducibility is clinically satisfactory in view of the high biological variability of the analyte that shows a within-subject variation of 36% [16].”
BackgroundAnandaram, P., Bolla, A. R. D., Hudson, P. R., Davies, G. K., Majumdar, P., & Williams, C. P. (2006) · Urological Research · doi:10.1007/s00240-006-0053-5 · Cited by 9
“Biological information on a large number of common laboratory analytes has been published [23], mainly on healthy individuals.”
BackgroundSerum Concentration of 17α-Hydroxyprogesterone in Children from Birth to Adolescence
Ballerini, M. G., Chiesa, A. E., Morelli, C., Frusti, M., & Ropelato, M. G. (2013) · Hormone Research in Paediatrics · doi:10.1159/000356906 · Cited by 9
Hulshof, P. J. M., Brouwer, J. T., BUREMA, J., & West, C. E. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.11.2061 · Cited by 9
Estimación de la incertidumbre y de la variabilidad total en el laboratorio clínico
Terrés-Speziale, A. M. (2006) · Revista Latinoamericana de Patología Clínica y Medicina de Laboratorio · Cited by 9
Bozkaya, G., & Şişman, A. R. (2020) · Annals of Translational Medicine · doi:10.21037/atm-20-6104 · Cited by 9
“91% we used in our study is derived from the biological variation studies (9,14) and is high.”
MethodInter-Method Differences and Commutability of Control Materials for HbA2 Measurement
Mosca, A., Paleari, R., Scimè‐Degani, V., Leone, L., Leone, D., & Ivaldi, G. (2000) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2000.148 · Cited by 9
A Two-Center Evaluation of the Blood Gas Immediate Response Mobile Analyzer (IRMA)
Ceriotti, F., Buono, L. D., Bonini, P. A., Germagnoli, L., Ferrero, C. A., Pezzo, M. P., & Marocchi, A. (2002) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2002.031 · Cited by 9
“Target for difference between Laboratory 1 Laboratory 2 inaccuracy (8) data sets* instruments instruments”
BackgroundBenoit, M., & Paul, J. (2009) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510902914073 · Cited by 9
Acutely developing, spurious anaemia without actual blood loss. A paradigmatic case report
Lippi, G., & Cervellin, G. (2017) · Biochemia Medica · doi:10.11613/bm.2017.045 · Cited by 8
Kim, H., Jo, S., & Kim, I. (2022) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0000000000001184 · Cited by 8
Pratumvinit, B., Reesukumal, K., Wongkrajang, P., Khejonnit, V., Klinbua, C., & Dangneawnoi, W. (2013) · Clinica Chimica Acta · doi:10.1016/j.cca.2013.08.025 · Cited by 8
Nutrition and Chronic Conditions
Ojo, O. (2019) · MDPI eBooks · doi:10.3390/books978-3-03897-603-5 · Cited by 8
Güssow, A., Thalmeier, S., Gostelow, R., Langenstein, J., Foerster, G., Bauer, N. B., & Hazuchova, K. (2023) · Veterinary Sciences · doi:10.3390/vetsci10090575 · Cited by 8
New Guidelines of the German Medical Association for Quality Assurance of Medical Laboratory Tests
Vogt, W. (2015) · Journal of Laboratory Medicine · doi:10.1515/labmed-2015-0013 · Cited by 8
“For assessing the permissible error, biological variance [7] can be used as a guide.”
MethodAlmquist, M., Bondeson, A., Bondeson, L., Halthur, C., Malm, J., & Manjer, J. (2008) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510802262672 · Cited by 8
“Both short-time [29] and long-time [30] intra-individual variation in total serum calcium are low.”
BackgroundMina, A. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.017 · Cited by 8
“The BV material was compiled from published articles referenced in BIOS, Current Contents, EMBASE, MEDLINE, books and doctoral theses into a database (10).”
MethodDisorders of calcium metabolism
Winter, W. E., & Harris, N. (2020) · Elsevier eBooks · doi:10.1016/b978-0-12-818277-2.00010-8 · Cited by 9
Evaluation of four different HPLC devices for hemoglobinopathy screening
Ercan, M., Akbulut, E. D., Avcı, E., Oğuz, E. F., Kader, S., Abuşoğlu, G., Serdar, M. A., & Yılmaz, F. M. (2020) · Turkish Journal of Biochemistry · doi:10.1515/tjb-2019-0484 · Cited by 8
Wedin, J. O., & Henriksson, A. E. (2020) · Journal of Sports Medicine · doi:10.1155/2020/6109308 · Cited by 8
“One possible explanation for our finding is that hypovolemia rapidly induces a compensatory increase in blood volume by the exchange of fluid from the interstitium to the blood, which will result in hemodilution and thus decreased Hb concentration [23].”
BackgroundRossi, G., Meazzi, S., Giordano, A., & Paltrinieri, S. (2020) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/1040638720949638 · Cited by 8
“We demonstrated that our method is precise and accurate given that both intra-assay and inter-assay imprecision were < 5% (an acceptable imprecision for most biochemical analytes).(44) The LUD and SRT confirmed the excellent accuracy of this method, already recorded in other species.”
ResultMoon, S. Y., Lee, H. S., Park, M. S., Kim, I., & Lee, S. M. (2020) · Annals of Laboratory Medicine · doi:10.3343/alm.2021.41.3.277 · Cited by 8
Unbalanced intakes of sodium and potassium among Tunisian adults: A cross‐sectional study
Doggui, R., Ati, J. E., Sassi, S., Gharbia, H. B., Al‐Jawaldeh, A., & Ati‐Hellal, M. E. (2021) · Food Science & Nutrition · doi:10.1002/fsn3.2197 · Cited by 8
Tsiamyrtzis, P., Sobas, F., & Négrier, C. (2015) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0000000000000314 · Cited by 8
Parallel processing and maintaining adequate alignment between instruments and methods.
Calleja, J. (2008) · PubMed · Cited by 8
A new internal quality control chart based on biological variation
Coşkun, A., Serteser, M., Fraterman, A., & Ünsal, İ. (2008) · Accreditation and Quality Assurance · doi:10.1007/s00769-007-0345-7 · Cited by 8
Nomura, N., Saito, K., Ikeda, M., Yuasa, S., Pastore, M., Chabert, C., Kono, E., Sakai, A., Tanaka, H., Ikemoto, T., et al. (2014) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12312 · Cited by 8
Evolving Concepts And Techniques For Anti-Doping
Friedmann, T., Flenker, U., Georgakopoulos, C. G., Alsayrafi, M., Sottas, P., Williams, S. A., & Gill, R. D. (2012) · Bioanalysis · doi:10.4155/bio.12.146 · Cited by 8
Using Biological Variation Data for Reference Change Values in Clinical Laboratories
Öztürk, Ö. G. (2012) · Biochemistry & Analytical Biochemistry · doi:10.4172/2161-1009.1000e106 · Cited by 8
“A comprehensive database constituted from BV data of nearly 320 analytes which is updated every 2 years serves as a useful reference for many clinical laboratories [3,4].”
Performance of 6 routine coagulation assays on the new Roche Cobas t711 analyzer
Oostendorp, M., Noorman, R. L., Nijenhuis, J. D., & de Kok, J. B. (2019) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2019.e00146 · Cited by 8
Nuanin, S. (2020) · Siriraj Medical Journal/San Sirirat · doi:10.33192/smj.2020.40 · Cited by 8
Fuster, Ó., Andino, B., & Laíz, B. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0409 · Cited by 8
“9% for platelet count bias, as derived from intra- and inter-individual biologic variation [8], the PLT-O method is not interchangeable as it presented an 18.”
MethodThe impact of different sample matrices in delayed measurement of glucose
Roccaforte, V., Daves, M., Platzgummer, S., & Lippi, G. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.08.015 · Cited by 9
Technical and clinical evaluation of a glucose meter employing amperometric biosensor technology
Demir, S., Yilmazturk, G. C., & Aslan, D. (2007) · Diabetes Research and Clinical Practice · doi:10.1016/j.diabres.2007.10.006 · Cited by 8
Ric�s, C., Álvarez, V., Cava, F., Garc�a-Lario, J. V., Hern�ndez, A., Jim�nez, C. V., Minchinela, J., Perich, C., & Sim�n, M. (2004) · Accreditation and Quality Assurance · doi:10.1007/s00769-003-0727-4 · Cited by 8
Short-term effect of dark chocolate consumption on routine haemostasis testing
Montagnana, M., Danese, E., Salvagno, G. L., & Lippi, G. (2017) · International Journal of Food Sciences and Nutrition · doi:10.1080/09637486.2016.1268101 · Cited by 7
Performance Study of Noninvasive Salivary Biomarkers in Laryngopharyngeal Reflux
Vos, N. D., Trelcat, A., Antoine, M., Dahma, H., Muls, V., Hans, S., Saussez, S., & Lechien, J. R. (2025) · The Journal of Applied Laboratory Medicine · doi:10.1093/jalm/jfaf171 · Cited by 7
Loh, T. P., Tan, R. Z., Sethi, S. K., Lim, C. Y., & Markus, C. (2023) · Advances in clinical chemistry · doi:10.1016/bs.acc.2023.03.005 · Cited by 7
Comparison of three different protocols for obtaining hemolysis
Nikolac, N., Miler, M., Vrtarić, A., Ćelap, I., Bocan, M., Filipi, P., Biljak, V. R., Šimundić, A.-M., Smolčić, V. Š., & Kocijančić, M. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-1227 · Cited by 7
Allison, T. R., Hunsaker, J. J. H., La’ulu, S. L., & Genzen, J. R. (2022) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2022.09.005 · Cited by 7
Clinical Thresholds for Pseudohyperkalemia and Pseudonormokalemia in Patients with Thrombocytosis.
Delgado, J. A., Andrade, B. L., Morell‐García, D., Martínez‐Morillo, E., Vizoso, M. A. B., Jiménez, S. A., Durán, M. A., & Bauçà, J. M. (2022) · PubMed Central · Cited by 7
Ali, M. A., Hossain, M. S., Juliana, F. M., & Reza, M. S. (2023) · Cureus · doi:10.7759/cureus.36242 · Cited by 7
“Using the collected information, RCV was determined by the following formula, RCV =√ 2 * Z * (CA2 + CVw 2)1/2 [12].”
MethodRandall, S. A., McKay, M. J., Pascovici, D., Mahon, K. L., Horvath, L. G., Clarke, S. J., & Molloy, M. P. (2012) · PROTEOMICS - CLINICAL APPLICATIONS · doi:10.1002/prca.201200039 · Cited by 7
Aakre, K. M., Oosterhuis, W. P., & Sandberg, S. (2012) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2011.646298 · Cited by 7
Blerk, M. V., Albarède, S., Déom, A., Gutiérrez, G., Heller, S., Nazor, A., Pakkanen, A., Rej, R., Curran, K. M., Sárkány, E., et al. (2008) · Accreditation and Quality Assurance · doi:10.1007/s00769-008-0364-z · Cited by 7
Molenaar, P. J., & Leyte, A. (2011) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2011.615 · Cited by 7
Impact of serum-clot contact time on lactate dehydrogenase and inorganic phosphorus serum levels
Bausset, O., Juvet, O., Staller-Gobelli, C., Milano, E., & Bausset, J.-P. (2017) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2017.01.002 · Cited by 7
Aziz, N., Quint, J. J., Breen, E. C., Oishi, J. S., Jamieson, B. D., Martínez-Maza, O., & Detels, R. (2018) · Laboratory Medicine · doi:10.1093/labmed/lmy044 · Cited by 7
Biochemical Diagnosis of Wilson Disease
Mak, C. M. (2018) · Elsevier eBooks · doi:10.1016/b978-0-12-810532-0.00021-5 · Cited by 7
Performance evaluation of HbA1c measurement systems with sigma metric for 1066 laboratories in China
Huang, Y., Zhang, T., Zhao, H., Wang, W., Zhang, C., He, F., Zhong, K., Yuan, S. S., Du, Y., & Wang, Z. (2018) · Clinica Chimica Acta · doi:10.1016/j.cca.2018.10.015 · Cited by 7
Impact of low volume citrate tubes on results of first‐line hemostasis testing
Salvagno, G. L., Demonte, D., Poli, G., Favaloro, E. J., & Lippi, G. (2019) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13028 · Cited by 7
Ana María Guzmán, D. (2010) · Revista médica de Chile · doi:10.4067/s0034-98872010000600018 · Cited by 7
Gabriel, A., Benedito‐Silva, A. A., de Martino, M. C., Razvickas, W. J., Silva, R. C., Viana, A. M., Maurício, R. C., Santos, S. A. L., & Tufik, S. (2007) · Jornal Brasileiro de Patologia e Medicina Laboratorial · doi:10.1590/s1676-24442007000400003 · Cited by 7
Sampling on ice will not yield reliable uric acid monitoring in rasburicase-treated patients
Depreter, B., Stove, V. V., & Delanghe, J. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.04.011 · Cited by 7
Time-dependent variation of ionized calcium in serum samples
Perović, A., & Bratičević, M. N. (2019) · Biochemia Medica · doi:10.11613/bm.2019.030708 · Cited by 7
Uncertainty in Measurement - Introduction and Examples from Laboratory Medicine.
Kallner, A. (2001) · PubMed Central · Cited by 7
Aziz, N., Jamieson, B. D., Quint, J. J., Martínez-Maza, O., Chow, M., & Detels, R. (2019) · Medicine · doi:10.1097/md.0000000000017525 · Cited by 7
Taylor, A., Angerer, J., Arnaud, J., Claeys, F., Jones, R. L., Mazarrasa, O., Mairiaux, E., Menditto, A., Parsons, P. J., Patriarca, M., et al. (2006) · Accreditation and Quality Assurance · doi:10.1007/s00769-006-0118-8 · Cited by 7
Preliminary performance evaluation of blood gas analyzers
Couck, P., Ghys, T., Gastel, E. V., Coillie, M. V., Gorus, F., & Gerlo, E. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.185 · Cited by 7
“4%) at the low and high levels, based on biological variation (4).”
BackgroundMethodHomocysteine measurement by Vitros® Microtip homocysteine assay
Martens, G. A., Nayer, J. D., Smet, D. D., Couck, P., Gorus, F., & Gerlo, E. (2008) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2008.054 · Cited by 7
Clinical quality vs analytical performance: what are the right targets and target values?
Westgard, J. O. (2004) · Accreditation and Quality Assurance · doi:10.1007/s00769-004-0868-0 · Cited by 7
Borai, A., Livingstone, C., & Ferns, G. A. (2013) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2013.771281 · Cited by 7
“All currently available estimates of Bv (around 320 analytes) have been compiled in a database which is updated every two years [11].”
BackgroundPreservation of urine specimens for metabolic evaluation of recurrent urinary stone formers
Šálek, T., Musil, P., Vermeersch, P., Marrington, R., Dikmen, Z. G., Poláchová, R., Kipman, U., Kouri, T., & Cadamuro, J. (2024) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2024-0773 · Cited by 6
Laboratory medicine and sports: where are we now?
Berković, M. C., Matanović, L., Buljubašić, R., Marijančević, D., Žarak, M., Perović, A., Šimac, B., Marević, S., Biljak, V. R., & Đerek, L. (2024) · Biochemia Medica · doi:10.11613/bm.2024.030501 · Cited by 6
“…among other models, by the model based on components of biological variation (BV) of the measurand, to the new EFLM updated biological variation database based on the strict meta-analysis of the published studies, biological variability has become an integrated part of laboratory medicine (6-8).”
Munir, R. I., Schapkaitz, E., Noble, L. D., Loonat, S. B., Cree, M. M., Ali, N., Jacobson, B. F., Stevens, W. S., & Scott, L. E. (2024) · Diagnostics · doi:10.3390/diagnostics14232683 · Cited by 6
An Overview of Allowable Total Error in the Clinical Laboratory
Campbell, M. R., & Galior, K. D. (2025) · The Journal of Applied Laboratory Medicine · doi:10.1093/jalm/jfaf160 · Cited by 6
Guo, X., Zhao, F., Yin, Y., Wang, D., Hou, L., Wu, J., Li, D., Cheng, X., Xia, L., Xu, E., et al. (2018) · Clinica Chimica Acta · doi:10.1016/j.cca.2018.04.014 · Cited by 6
Establishing biological variation for plasma D-dimer from 25 healthy individuals
Ercan, Ş., & Ercan, M. (2021) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2021.1947522 · Cited by 6
“Attempts to compile existing publications related to BV have resulted in the generation of the BV database by the Analytical Quality Commission of the Spanish Society of Laboratory Medicine [3].”
MethodGyörfi, I., Pál, K., Mănescu, I. B., Oprea, O. R., & Dobreanu, M. (2021) · Revista română de medicină de laborator · doi:10.2478/rrlm-2021-0027 · Cited by 6
Post-collection acidification of spot urine sample is not needed before measurement of electrolytes
Šálek, T., Musil, P., Pšenčík, M., & Palička, V. (2022) · Biochemia Medica · doi:10.11613/bm.2022.020702 · Cited by 6
“reported intraindividual biological variations of urine calcium, magnesium and inorganic phosphorus in 24-hour urine collections (11).”
BackgroundHoovels, L. V., Massa, B., Stavelin, A. V., Meyer, H. D., Schrijver, P. D., Laethem, V. V., Barglazan, D., Gruson, D., Hopstaken, R., Peeters, B., et al. (2024) · Clinica Chimica Acta · doi:10.1016/j.cca.2024.119737 · Cited by 6
Short-term storage stability of serum angiotensin-converting enzyme (ACE) activity
Čuljak, M., Nikolac, N., & Šimundić, A.-M. (2015) · Clinica Chimica Acta · doi:10.1016/j.cca.2015.05.001 · Cited by 6
Does fist pumping/clenching during venipuncture activate blood coagulation?
Lippi, G., Lima-Oliveira, G., & Guidi, G. C. (2016) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0000000000000429 · Cited by 6
Tenor, D. P., de Medio, E. P., Torres, P. M. B., Luna, F., García, L. J. M., Lorenzo-Lozano, M. C., Delgado, M. P., Sánchez, A. C., Menchero, S. P., & Cenzual, M. Á. C. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-0354 · Cited by 6
“4% for LDH according to the desirable specification based on biological variation [10].”
BackgroundAlpha-fetoprotein in pericardial, peritoneal, and pleural fluids: A body fluid matrix evaluation
Owen, W. E., Hunsaker, J. J. H., & Genzen, J. R. (2018) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2018.04.019 · Cited by 6
Introductory Chapter: History and Scope of Quality Control in Laboratories
Zaman, G. S. (2018) · InTech eBooks · doi:10.5772/intechopen.74593 · Cited by 6
Necessity of Routine Repeat Testing of Critical Values in Various Working Shifts
Saffar, H., Abdollahi, A., Hosseini, A. S., Farsani, M. T., Hajinasrollah, G., & Mohaghegh, P. (2020) · Iranian journal of pathology · doi:10.30699/ijp.2020.99403.1980 · Cited by 6
Zhang, R., & Wang, Q. (2020) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.23557 · Cited by 6
Methodology of Environmental Standardization for Natural Waters
Danilov-Danil’yan, V. I., & Rosenthal, O. M. (2021) · Doklady Earth Sciences · doi:10.1134/s1028334x2110007x · Cited by 6
Boer, A., Deneer, R., Maas, M., Ammerlaan, H., van Balkom, R. H. H., Thijssen, W. A. M. H., Bennenbroek, S., Leers, M. P. G., Martens, R. J. H., Buijs, M. M., et al. (2022) · BMJ Open · doi:10.1136/bmjopen-2021-059111 · Cited by 6
Садовников, П. С., Olkhovik, A. Y., & Гуревич, В. С. (2022) · Атеросклероз и дислипидемии · doi:10.34687/2219-8202.jad.2022.03.0003 · Cited by 6
Complete blood count at the ED: preanalytic variables for hemoglobin and leukocytes
Carraro, P., Vettore, G., Padoan, A., Piva, E., & Plebani, M. (2015) · The American Journal of Emergency Medicine · doi:10.1016/j.ajem.2015.05.011 · Cited by 6
The effect of hyperglycaemia on haemostasis testing – a volunteer study
Lippi, G., Buonocore, R., Musa, R., Ippolito, L., Picanza, A., & Favaloro, E. J. (2014) · Anaesthesia · doi:10.1111/anae.12990 · Cited by 6
Homogenization of the lipid profile values
Pedro‐Botet, J., Padial, L. R., Brotons, C., Esteban-Salán, M., García-Lerín, A., Pintó, X., Lekuona, I., & Ordóñez‐Llanos, J. (2018) · Clínica e Investigación en Arteriosclerosis (English Edition) · doi:10.1016/j.artere.2017.12.001 · Cited by 6
Allowable systematic difference between two instruments measuring the same analyte
Åsberg, A., Solem, K. B., & Mikkelsen, G. (2014) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2014.921836 · Cited by 6
Serum and urine osmolality: 8 hours, 24 hours and 1-month sample stability
Đuras, A., Kocijan, V. C., Rade, A., Lipovec, R., Ostroški, I., Biljak, V. R., & Šimundić, A.-M. (2022) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2022.2079094 · Cited by 6
Nunes, L. A. S., Lorenzi, F., Brenzikofer, R., & de Macedo, D. V. (2012) · InTech eBooks · doi:10.5772/27971 · Cited by 7
“Both CVI and CVG are influenced by age, sex, weight, diet, circadian rhythm, pathologies and physical activity (Ricós et al. 2004), and it is possible to estimate them using data banks that are available in the literature for many analytes in healthy, non-exercised subjects (Ricos et al., 1999).”
BackgroundCoşkun, A., Ünsal, İ., Serteser, M., & Fraterman, A. (2009) · Accreditation and Quality Assurance · doi:10.1007/s00769-009-0549-0 · Cited by 6
Post-analytical stability of 23 common chemistry and immunochemistry analytes in incurred samples
Nielsen, B. K., Frederiksen, T., Friis-Hansen, L. J., & Larsen, P. B. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.08.003 · Cited by 6
Peterson, R., Wilund, K. R., Cunningham, B. T., & Andrade, J. E. (2017) · Sensors · doi:10.3390/s17102203 · Cited by 6
“When the TEcalc is less than TEa for a given biomarker, the method is considered acceptable [29].”
BackgroundMethodInfluentialIrvine, K. L., Mans, C., & Friedrichs, K. R. (2017) · Journal of Veterinary Diagnostic Investigation · doi:10.1177/1040638717739059 · Cited by 6
“If calculated total observed error (TE obs ) was greater than the TE A , the quality requirement for between-day coefficient of variation (CV) was set at ≤10%; this is based on available biologic variation for triglycerides in people because data are not available for avian species.(16) The predetermined recovery and…”
BackgroundA new approach to define acceptance limits for hematology in external quality assessment schemes
Soumali, M. R., Blerk, M. V., Akharif, A., Albarède, S., Kesseler, D., Gutiérrez, G., la Salle, B. D., Plum, I., Guyard, A., Favia, A. P., et al. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-1048 · Cited by 6
Nonkes, L. J. P., Kemperman, H., Gerritsen, K. G. F., ten Berg, M. J., Boereboom, F. T. J., Abrahams, A. C., & van Gelder, M. K. (2018) · Biochemia Medica · doi:10.11613/bm.2019.010709 · Cited by 6
Ekström, U., Apelqvist, J., Hansson, E., Bodin, T., Wegman, D. H., Abrahamson, M., & Jakobsson, K. (2019) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2019.1700425 · Cited by 6
“The underlying rationale for using sodium as a substitute for a formal standard is that the physiological variation of serum sodium within and between healthy individuals is very low [14].”
BackgroundMandić, S., Mandić, D., Šerić, V., Osvald, S., Lukić, M., Horvat, V., Rolić, T., & Lukić, I. (2020) · Biochemia Medica · doi:10.11613/bm.2020.030704 · Cited by 6
Valentine, H., & Dawnay, A. (2021) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/00045632211029327 · Cited by 6
“Bias was assessed using Z-score, desirable bias, desirable total error and desirable minimum error as defined in Ricos et al.12 using nonparaprotein biological variation data for immunoglobulins.13,14 No significant bias was noted.”
MethodIuA, R., & Rosental, O. M. (2021) · Hygiene and Sanitation · doi:10.47470/0016-9900-2021-100-11-1198-1202 · Cited by 6
Šegulja, D., Šparakl, T., & Rogić, D. (2022) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2022.2034035 · Cited by 6
“goals for desirable imprecision (not available in EFLM database) [10].”
BackgroundLee, B., & Park, H. (2022) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.24295 · Cited by 6
Point-of-Care Testing in the Indigenous Rural Environment - The Australian Experience
Shephard, M. D. S. (2004) · Flinders Academic Commons (Flinders University) · Cited by 6
Metadata
- Authors
- C. Ricós, V. A.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1999-01
- Volume
- 59
- Issue
- 7
- Pages
- 491-500
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2119950421
- Cited by
- 987
- References
- 6
- Citations by year
- 2026: 17 · 2025: 25 · 2024: 22 · 2023: 29 · 2022: 41 · 2021: 44 · 2020: 47 · 2019: 51 · 2018: 64 · 2017: 69 · 2016: 58 · 2015: 46 · 2014: 76 · 2013: 56 · 2012: 55
- FWCI
- 5.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Scandinavian Journal of Clinical and Laboratory Investigation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- biological variation, reference values, clinical laboratory testing, within-subject coefficient of variation, total error, bias and precision, disease states, hormones
- MeSH terms
- Humans, Quality Control, Clinical Laboratory Techniques, Databases as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.