Current databases on biological variation: pros, cons and progress
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A database with reliable information to derive definitive analytical quality specifications for a large number of clinical laboratory tests was prepared in this work. This was achieved by comparing and correlating descriptive data and relevant observations with the biological variation information, an approach that had not been used in the previous efforts of this type. The material compiled in the database was obtained from published articles referenced in BIOS, CURRENT CONTENTS, EMBASE and MEDLINE using "biological variation & laboratory medicine" as key words, as well as books and doctoral theses provided by their authors. The database covers 316 quantities and reviews 191 articles, fewer than 10 of which had to be rejected. The within- and between-subject coefficients of variation and the subsequent desirable quality specifications for precision, bias and total error for all the quantities accepted are presented. Sex-related stratification of results was justified for only four quantities and, in these cases, quality specifications were derived from the group with lower within-subject variation. For certain quantities, biological variation in pathological states was higher than in the healthy state. In these cases, quality specifications were derived only from the healthy population (most stringent). Several quantities (particularly hormones) have been treated in very few articles and the results found are highly discrepant. Therefore, professionals in laboratory medicine should be strongly encouraged to study the quantities for which results are discrepant, the 90 quantities described in only one paper and the numerous quantities that have not been the subject of study.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, the characteristics of the populations studied in the papers included in the historical estimates varied and include diseased (uncomplicated myocardial infarction, liver disease, type 1 diabetes mellitus) and non-diseased subjects [12, 16].”
From The European Biological Variation Study (EuBIVAS): a summary report (2022) · cites this paper as [12]
Citations
Cites
Generation and Application of Data on Biological Variation in Clinical Chemistry
Fraser, G. G., & Harris, E. K. (1989) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408368909106595 · Cited by 870
Fraser, C. G., Petersen, P. H., Ricós, C., & Haeckel, R. (1992) · PubMed · Cited by 125
The application of theoretical goals based on biological variation data in proficiency testing.
Cg, F. (1988) · PubMed · Cited by 119
(1997) · PubMed · Cited by 102
Biological variation in clinical chemistry. An update: collated data, 1988-1991.
Fraser, C. G. (1992) · PubMed · Cited by 91
The "index of fiduciality" proposed for use in evaluation and comparison of methods.
Fraser, C. G., & Browning, M. C. (1988) · Clinical Chemistry · doi:10.1093/clinchem/34.6.1356 · Cited by 13
Research works printed but not linked: 3
- Fraser CG, 1988, Arch Pathol Lab Med, 112, 404
- Fraser CG, 1992, Collated data, 1988-1991. Arch Pathol Lab Med, 116, 916
- Fraser CG, 1992, Eur J Clin Chem Clin Biochem, 30, 311
Cited by
Items 401–500 of 1,000
Cattozzo, G., Guerra, E., Ceriotti, F., & Franzini, C. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2007.100081 · Cited by 19
HbA1c: A comparison of NGSP with IFCC transformed values
Dhatt, G. S., Agarwal, M., & Bishawi, B. (2005) · Clinica Chimica Acta · doi:10.1016/j.cccn.2005.02.009 · Cited by 19
Evaluation of a glucose meter against analytical quality specifications for hospital use
Dhatt, G. S., Agarwal, M., & Bishawi, B. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.01.021 · Cited by 19
Influence of primary sample mixing on routine coagulation testing
Lippi, G., Salvagno, G. L., Montagnana, M., & Guidi, G. C. (2007) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0b013e32828621a0 · Cited by 18
Lo, S. F., Miller, W. G., & Doumas, B. T. (2013) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2012-0152-cp · Cited by 18
“7% for total error with a coverage factor of 2 (which gives a value similar to a 95% or a 62-SD interval in the absence of bias).(11) Based on biologic-variability criteria, neither BCG nor BCP albumin methods had satisfactory performance based only on coefficient of variation values.”
BackgroundResultFull method validation in clinical chemistry
Theodorsson, E., & Magnusson, B. (2017) · Accreditation and Quality Assurance · doi:10.1007/s00769-017-1275-7 · Cited by 18
Dupuy, A., Bargnoux, A. S., Kuster, N., Cristol, J., & Badiou, S. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-1228 · Cited by 18
“[14] and by the literature for PCT [15] and hs-cTnT [16] (see Tables 1 and 2).”
Li, Y., Qian, Y., Zhang, X., & Chen, X. (2021) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.23985 · Cited by 18
Alis, R., Sanchis‐Gomar, F., Risso-Ballester, J., Blesa, J. R., & Romagnoli, M. (2015) · Platelets · doi:10.3109/09537104.2015.1047334 · Cited by 18
Tholance, Y., Barcelos, G. K., Quadrio, I., Renaud, B., Dailler, F., & Perret‐Liaudet, A. (2010) · Clinica Chimica Acta · doi:10.1016/j.cca.2010.12.025 · Cited by 18
“Pyruvate specifications [38] were only reported for blood measurement with a TE of ±17.”
BackgroundAcosta‐Martin, A. E., Graça, D. C., Antinori, P., Clerici, L., Hartmer, R., Meyer, M., Hochstrasser, D. F., Samii, K., Lescuyer, P., & Scherl, A. (2013) · Analytical Chemistry · doi:10.1021/ac401782t · Cited by 18
Influence of Centrifuge Temperature on Routine Coagulation Testing
Lippi, G., Salvagno, G. L., Montagnana, M., Poli, G., & Guidi, G. C. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.063149 · Cited by 18
Optimized Delta Check Rules for Detecting Misidentified Specimens in Children
Tan, R. Z., Markus, C., Choy, K. W., Doery, J. C. G., & Loh, T. P. (2019) · American Journal of Clinical Pathology · doi:10.1093/ajcp/aqz201 · Cited by 18
Nedeljković-Beleslin, B., Ćirić, J., Stojković, M., Savić, S., Lalić, T., Stojanovic, M. M., Miletić, M., Knežević, M., Stanković, B., & Žarković, M. (2020) · International Journal of Clinical Practice · doi:10.1111/ijcp.13608 · Cited by 18
Variación biológica. Revisión desde una perspectiva práctica
Ricós, C., Perich, C., Doménech, M., Fernández, P. F., Biosca, C., Minchinela, J., Simón, M. S., Cava, F., Álvarez, V., Jiménez, C. V., et al. (2010) · Revista del Laboratorio Clínico · doi:10.1016/j.labcli.2010.07.003 · Cited by 18
Uçar, F., Erden, G., Giniş, Z., Öztürk, G., Sezer, S., Gürler, M., & Guneyk, A. (2013) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2013.05.055 · Cited by 18
Reliability of automated synovial fluid cell counting with Mindray BC ‐6800 body fluid mode
Buoro, S., Seghezzi, M., Manenti, B., Mecca, T., Candiago, E., Vidali, M., Ottomano, C., Castelli, C. C., Ferrari, R. C., Zappalà, G., et al. (2017) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12632 · Cited by 17
Kim, S., Chang, J., Kim, S., Park, S., Huh, J., & Jeong, T. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2020-0454 · Cited by 17
Abraham, R. A., Rana, G., Agrawal, P. K., JOHNSTON, R. V., Sarna, A., Ramesh, S., Acharya, R., Khan, N., Porwal, A., Kurundkar, S. B., et al. (2021) · Journal of Laboratory Physicians · doi:10.1055/s-0041-1726575 · Cited by 17
Blood Plasma Quality Control by Plasma Glutathione Status
Tomin, T., Bordag, N., Zügner, E., Al-Baghdadi, A., Schinagl, M., Birner‐Gruenberger, R., & Schittmayer, M. (2021) · Antioxidants · doi:10.3390/antiox10060864 · Cited by 17
Gils, C., Ramanathan, R., Breindahl, T., Brokner, M., Christiansen, A. L., Eng, Ø., Hammer, I. J., Herrera, C. B., Jansen, A., Langsjøen, E. C., et al. (2015) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2015.1066846 · Cited by 17
Estabilidad de 27 magnitudes bioquímicas en muestras de suero conservadas en refrigeración
Alcaraz‐Quiles, J., Rico, N., & Chesa, J. L. B. (2014) · Revista del Laboratorio Clínico · doi:10.1016/j.labcli.2014.02.003 · Cited by 17
Floré, K., Fiers, T., & Delanghe, J. (2008) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2008.332 · Cited by 17
“Glucose method n Target, Mean, SD, CV, % NBiasN Desirable specifications (11)”
BackgroundMethodResultInfluentialRotteveel, D. M., Ross, H. A., Janssen, M. J. R., Netea-Maier, R. T., Oosting, J. D., Sweep, F. C. G. J., & van Herwaarden, A. E. (2016) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2016.02.001 · Cited by 17
Impact of delta check time intervals on error detection capability
Tan, R. Z., Markus, C., & Loh, T. P. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-1004 · Cited by 17
Cervellin, G., Mitaritonno, M., Pedrazzoni, M., Picanza, A., & Lippi, G. (2014) · Advances in Orthopedics · doi:10.1155/2014/397059 · Cited by 17
“This study was aimed at investigating the prevalence of hyponatremia in patients with intracapsular femoral neck fracture.”
BackgroundDaves, M., Giacomuzzi, K., Tagnin, E., Jani, E., Funk, D. M. A., Favaloro, E. J., & Lippi, G. (2014) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0000000000000026 · Cited by 17
Importance of the biological variability and the medically relevant in the Norm ISO-15189
Terrés-Speziale, A. M. (2003) · Revista Latinoamericana de Patología Clínica y Medicina de Laboratorio · Cited by 17
Monoclonal protein reference change value as determined by gel-based serum protein electrophoresis
Salamatmanesh, M., McCudden, C. R., McCurdy, A. B. R., & Booth, R. A. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.10.006 · Cited by 17
Influence of two different buffered sodium citrate concentrations on coagulation testing
Lippi, G., Salvagno, G. L., Montagnana, M., & Guidi, G. C. (2005) · Blood Coagulation & Fibrinolysis · doi:10.1097/01.mbc.0000172097.15458.c5 · Cited by 15
Tong, W., Tong, G., Yang, M., & Qin, X. (2021) · Nutrition · doi:10.1016/j.nut.2021.111490 · Cited by 16
Relationship between timed and spot urine collections for measuring phosphate excretion
Tan, S., Smith, E. R., Cai, M. M., Holt, S. G., Hewitson, T. D., & Toussaint, N. D. (2015) · International Urology and Nephrology · doi:10.1007/s11255-015-1149-z · Cited by 16
“1 % for UPE and TmP/GFR, respectively [27].”
BackgroundMolina, Á., Guiñón, L., Pérez, A., Segurana, A., Bedini, J. L., Reverter, J. C., & Merino, A. (2018) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12783 · Cited by 16
Elmeshreghi, T. N., Grubb, T., Greene, S. A., Ragle, C. A., & Wardrop, J. (2018) · Veterinary Clinical Pathology · doi:10.1111/vcp.12635 · Cited by 16
Recordati, C., Maglie, M. D., Marsella, G., Milite, G., Rigamonti, A., Paltrinieri, S., & Scanziani, E. (2019) · Toxicologic Pathology · doi:10.1177/0192623319852353 · Cited by 16
Kraus, F. B., Kocijančić, M., Kluttig, A., & Ludwig‐Kraus, B. (2020) · Biochemia Medica · doi:10.11613/bm.2020.010707 · Cited by 16
“7%, based on the biological variation of βOHB (21,22).”
BackgroundMethodÖzdemir, Ş., & Uçar, F. (2022) · Journal of Laboratory Medicine · doi:10.1515/labmed-2021-0116 · Cited by 16
Steinmetz, J., Schiele, F., Gueguen, R., Férard, G., & Henny, J. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.290 · Cited by 16
“9% for two control sera in all laboratories indicating that the precision requirements were reached (2, 28).”
BackgroundMeasurement of renal function in kidney donors using serum cystatin C and β 2 -microglobulin
John, G. T., Fleming, J. J., Talaulikar, G. S., Selvakumar, R., Thomas, P. P., & Jacob, C. K. (2003) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/000456303770367252 · Cited by 16
Evaluation of Beckman Coulter DxI 800 immunoassay system using clinically oriented performance goals
Akbas, N., Schryver, P. G., Algeciras‐Schimnich, A., Baumann, N. A., Block, D. R., Budd, J. R., Gaston, S., & Klee, G. G. (2014) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2014.08.005 · Cited by 16
Sottas, P., Kapke, G. F., Vesterqvist, O., & Leroux, J.-M. (2011) · Translational research · doi:10.1016/j.trsl.2011.08.005 · Cited by 16
Evaluation of the QBC Star centrifugal three-part differential haematology system
Erhabor, O., Richardson, G., Mohammed, I., Thornton, C., Bark, J., Hurst, M., Hamer, D., & Kinsella, R. (2013) · British Journal of Biomedical Science · doi:10.1080/09674845.2013.11669938 · Cited by 16
Time required for resetting postural effects on serum constituents in healthy individuals
Shimizu, Y., Ichihara, K., & Kouguchi, K. (2017) · Clinica Chimica Acta · doi:10.1016/j.cca.2017.07.022 · Cited by 16
“In order to interpret the practical significance of the postural changes, we computed a ratio of the difference from the basal value relative to the allowable limit of bias (BA) [9] (for each individual’s basal value) at each time point as shown in Figure 2 for the same analytes shown in Figure 1.”
BackgroundMethodAnalytical variability of estimated platelet counts on canine blood smears
Paltrinieri, S., Paciletti, V., & Zambarbieri, J. (2018) · Veterinary Clinical Pathology · doi:10.1111/vcp.12604 · Cited by 16
Will “personalized medicine” need personalized laboratory approach?
Guidi, G. C., & Lippi, G. (2008) · Clinica Chimica Acta · doi:10.1016/j.cca.2008.09.029 · Cited by 17
Variability of the biological variation
Fuentes‐Arderiu, X. (2002) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/003655102321004585 · Cited by 16
Quantification of carbamylated albumin in serum based on capillary electrophoresis
Delanghe, S. E., Moerman, A., Pletinck, A., Schepers, E., Glorieux, G., Biesen, W. V., Delanghe, J., & Speeckaert, M. M. (2017) · Electrophoresis · doi:10.1002/elps.201700068 · Cited by 15
Bone turnover marker monitoring in osteoporosis treatment response
Tan, R. Z., Loh, T. P., & Vasikaran, S. D. (2020) · European Journal of Endocrinology · doi:10.1530/eje-19-0970 · Cited by 15
Landberg, E., Nevander, S., Hadi, M. A., Blomberg, M. I., Norling, A., Ekman, B., & Lilliecreutz, C. (2021) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2021.1980224 · Cited by 16
“1% based on the published results of biological variation [20,22].”
BackgroundGuerti, K., Vertessen, F., DANIËLS, L., & van der Planken, M. (2009) · International Journal of Laboratory Hematology · doi:10.1111/j.1751-553x.2007.01011.x · Cited by 15
Validating New Reagents: Roadmaps Through the Wilderness
Martindale, R. A., Cembrowski, G. S., Journault, L. J., Crawford, J. L., Tran, C., Hofer, T. L., Rintoul, B. J., Der, J. S., Revers, C. W., Vesso, C. A., et al. (2006) · Laboratory Medicine · doi:10.1309/brc6y37nm3bu97wx · Cited by 15
Ruggerone, B., Bonelli, F., Nocera, I., Paltrinieri, S., Giordano, A., & Sgorbini, M. (2018) · Veterinary Clinical Pathology · doi:10.1111/vcp.12562 · Cited by 15
Arredondo, M. E., Aranda, E., Astorga, R., Brennan-Bourdon, L. M., Campelo, M. D., Flores, S., Medel, C., Manríquez, I., Ochoa, P., Varela, B. G., et al. (2019) · TH Open · doi:10.1055/s-0039-3401002 · Cited by 15
Brändstedt, J., Almquist, M., Ulmert, D., Manjer, J., & Malm, J. (2015) · Cancer Causes & Control · doi:10.1007/s10552-015-0684-3 · Cited by 15
“Similarly, researchers have found little short-term [56] or long-term [57] intra-individual variation in total serum levels of calcium.”
Performance of a multi-profile critical care testing analyzer
Vanavanan, S., & Chittamma, A. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2008.003 · Cited by 15
A method to estimate the uncertainty of measurements in a conglomerate of instruments/laboratories
Kallner, A., Khorovskaia, L. A., & Pettersson, T. (2005) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510500206567 · Cited by 15
“Numbers in bold type indicate a CV% that is larger than those in the reference database [3,4].”
BackgroundInfluentialIs liquid heparin comparable to dry balanced heparin for blood gas sampling in intensive care unit?
Goyal, P., Chhapola, V., & Kumar, S. (2014) · Indian Journal of Critical Care Medicine · doi:10.4103/0972-5229.125428 · Cited by 15
“from data on within-subject and between-subject biologic variation.[10] The proportion of samples with differences beyond TEa% was calculated.”
Does Laboratory Automation for the Preanalytical Phase Improve Data Quality?
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Danese, E., Montagnana, M., Brocco, G., Voi, M., Picheth, G., & Guidi, G. C. (2013) · SLAS TECHNOLOGY · doi:10.1177/2211068213488892 · Cited by 15
Total Laboratory Automation of Routine Hemostasis Testing
Rin, G. D., & Lippi, G. (2013) · SLAS TECHNOLOGY · doi:10.1177/2211068213511246 · Cited by 15
Precision and long-term stability of capillary electrophoresis measurement of serum protein zones
Luraschi, P., Brambilla, S., Infusino, I., & Franzini, C. (2003) · Clinica Chimica Acta · doi:10.1016/s0009-8981(03)00163-3 · Cited by 15
Analytical validation of novel cardiac biomarkers used in clinical trials
Wu, A. H. B. (2015) · American Heart Journal · doi:10.1016/j.ahj.2015.01.016 · Cited by 15
Integration of data derived from biological variation into the quality management system
Ricós, C., Álvarez, V., Cava, F., García-Lario, J. V., Hernández, A., Jiménez, C. V., Minchinela, J., Perich, C., & Simón, M. S. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.03.022 · Cited by 15
Evaluation of Cobas Integra® 800 under Simulated Routine Conditions in Six Laboratories
Redondo, F. L., Bermudez, P. G., Cocco, C., Colella, F., Graziani, M. S., Fiehn, W., Hierl, T., LeMoël, G., Belliard, A. M., Manene, D., et al. (2003) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2003.058 · Cited by 15
“(17), values in bold: exceeding limits, values in parentheses: interim quality specifications.”
BackgroundPractice-Oriented Quality Specifications for Therapeutic Drug Monitoring
Pauwels, S., Vermeersch, P., Desmet, K., & Vanstapel, F. J. L. A. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2013.217125 · Cited by 15
Moreno‐Cabañas, A., Morales‐Palomo, F., Álvarez-Jiménez, L., Mora‐Gonzalez, D., García, E., Martinez-Mulero, B., & Mora‐Rodríguez, R. (2024) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00501.2024 · Cited by 14
Analytical Interference by Contrast Agents in Biochemical Assays
Otnes, S., Fogh‐Andersen, N., Rømsing, J., & Thomsen, H. S. (2017) · Contrast Media & Molecular Imaging · doi:10.1155/2017/1323802 · Cited by 14
“Desirable Analytical Quality Specifications for imprecision, bias, and total error derived from intra- and interindividual biologic variation were used to assess the clinical relevance of the statistically significant changes in the analyte concentrations [36].”
MethodPrecision of autoantibody assays in clinical diagnostic laboratories: What is the reality?
Sénant, M., Musset, L., Chyderiotis, G., Guis, L., Damoiseaux, J. G. M. C., Fabien, N., & Dragon‐Durey, M. (2020) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2020.05.019 · Cited by 14
Managing biological variation data: modern approaches for study design and clinical application
Johnson, P. R., Shahangian, S., & Astles, J. R. (2021) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2021.1932718 · Cited by 14
“1904 Publication of statistical methods to analyze biological traits of organisms [4] 1934 First published report describing biological variation (BV) as an uncertainty component of test measurements [6] 1954 BV in humans described as diurnal rhythms of “physical factors” [7] 1970 Three-part series of articles address…”
MethodVariation in common laboratory test results caused by ambient temperature
Obermeyer, Z., & Pope, D. G. (2021) · Med · doi:10.1016/j.medj.2021.11.003 · Cited by 14
Oostendorp, M., ten Hove, C. H., van Berkel, M., & Roovers, L. (2023) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2022-0478-oa · Cited by 14
SKML-Quality Mark for point-of-care test (POCT) glucose meters and glucose meters for home-use
Jansen, R., & Slingerland, R. J. (2010) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2010.226 · Cited by 14
Multicenter verification of the Sysmex XN‐Series
Schoorl, M., Schoorl, M., Chevallier, M., van der Ploeg, T., & PELT, J. V. (2017) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12674 · Cited by 14
Evaluation of the HemoCue WBC DIFF in leukopenic patient samples
Kur, D. K., Agersnap, N., Holländer, N. H., Pedersen, O. B., & Friis-Hansen, L. J. (2020) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.13158 · Cited by 14
Öztürk, Ö. G., Paydaş, S., Balal, M., Şahin, G. T., Karaçor, E. D. Z., Ariyurek, S. Y., & Yaman, A. (2013) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.21625 · Cited by 14
“A comprehensive database constituted from BV data of nearly 320 analytes, which is updated every two years serves as a useful reference for many clinical laboratories (12,13).”
MethodA new device to relieve venipuncture pain can affect haematology test results.
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Campelo, M. D., Tajra, K. S. A., Gomes, F. D. S., Valentim, C. D., Romano, S. J. C., Picheth, G., & Guidi, G. C. (2014) · Europe PMC (PubMed Central) · doi:10.2450/2013.0002-13 · Cited by 14
Zerbinati, C., Galli, F., Regolanti, R., Poli, G., & Iuliano, L. (2015) · Clinica Chimica Acta · doi:10.1016/j.cca.2015.04.026 · Cited by 14
“The outcome of the imprecision and bias resulted well acceptable in terms of biological variation and fitness for purpose for vitamin assay in blood [27–29].”
BackgroundProverbio, D., Perego, R., Spada, E., Giorgi, G. B. D., Belloli, A. G., & Pravettoni, D. (2013) · The Scientific World JOURNAL · doi:10.1155/2013/216569 · Cited by 14
“Maximum allowable values for imprecision were obtained from desirable specification for total error, imprecision, and bias derived from biological variation in people [18].”
BackgroundDupuy, A., Vela, C., Badiou, S., Bargnoux, A. S., Josse, C., Roagna, N., Delage, M., Michel, F., Vernet, M., Destizons, D., et al. (2012) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0109 · Cited by 14
Zhao, R., Li, Y., & Dai, W. (2016) · Laboratory Medicine · doi:10.1093/labmed/lmv004 · Cited by 14
Performance of electrolyte measurements assessed by a trueness verification program
Ge, M., Zhao, H., Yan, Y., Zhang, T., Zeng, J., Zhou, W., Wang, Y., Meng, Q., & Zhang, C. (2016) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-1110 · Cited by 14
Stability of complete blood count in different storage conditions using the ABX PENTRA 60 analyzer
Oliveira, L. R., Simionatto, M., Cruz, B. R., Bittencourt, J. I. M., Krum, E. A., Moss, M. F., & Borato, D. C. K. (2018) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12797 · Cited by 14
Performance specifications and six sigma theory: Clinical chemistry and industry compared
Oosterhuis, W. P., & Severens, M. J. (2018) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2018.04.002 · Cited by 14
Jia, K., & Zhang, J. (2010) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2010.018 · Cited by 14
Are equally spaced specimen collections necessary to assess biological variation?
Biosca, C., Ricós, C., Jiménez, C. V., Lauzurica, R., & Galimany, R. (2000) · Clinica Chimica Acta · doi:10.1016/s0009-8981(00)00346-6 · Cited by 14
Creation of the necessary analytical quality for generating and using reference intervals
Klein, G., & Junge, W. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.139 · Cited by 14
“MAT recommendations based on the biological variation for individual quantities are reported elsewhere (8).”
BackgroundBiological variation: a still evolving facet of laboratory medicine
Šimundić, A.-M., Bartlett, W. A., & Fraser, C. G. (2015) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563214567478 · Cited by 14
“Generation of a comprehensive database of components of BV was initiated in 1997 by the Analytical Quality Commission (AQC) of the Spanish Society of Clinical Chemistry (SEQC).(3) A scoring system was designed to evaluate the robustness of data, and this has five essential criteria for inclusion: papers must be design…”
MethodMultilevel qualification of a large set of blood gas analyzers: Which performance goals?
Kuster, N., Bargnoux, A. S., Badiou, S., Dupuy, A., Piéroni, L., & Cristol, J. (2019) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2019.09.005 · Cited by 13
A Survey of Sigma Metrics across Three Academic Medical Centers
Feldhammer, M., Brown, M., Colby, J. M., Bryksin, J., Milstid, B., & Nichols, J. H. (2021) · The Journal of Applied Laboratory Medicine · doi:10.1093/jalm/jfab028 · Cited by 13
Zhou, W., Deng, Y., Zhao, H., & Zhang, C. (2022) · Annals of Laboratory Medicine · doi:10.3343/alm.2022.42.4.428 · Cited by 13
Defining allowable total error limits in the clinical laboratory
Palmer, J., & Galior, K. D. (2023) · Advances in clinical chemistry · doi:10.1016/bs.acc.2023.11.006 · Cited by 13
Elst, K. V., Vermeiren, S., Schouwers, S., Callebaut, V., Thomson, W., & Weekx, S. (2013) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12099 · Cited by 13
Chen, Y., Xu, G., & Yang, F. (2015) · PLoS ONE · doi:10.1371/journal.pone.0126053 · Cited by 13
Utilizing global data to estimate analytical performance on the Sigma scale
Westgard, S. A. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.02.013 · Cited by 13
How do we use the data from pre-analytical quality indicators and how should we?
Cadamuro, J., Gaksch, M., Mrazek, C., Haschke‐Becher, E., & Plebani, M. (2018) · Journal of Laboratory and Precision Medicine · doi:10.21037/jlpm.2018.04.04 · Cited by 14
“These occur in many different places, mostly outside of the laboratory, involve many parties, such as patients, clinicians, nurses or sample carriers, and include many influencing variables, for instance (16): test selection (17), a process step also referred to as the prepre-analytical step (18), patient medication a…”
BackgroundMining the Age-Dependent Reference Intervals of B Vitamins from Routine Laboratory Test Results
Evliyaoğlu, O., van Helden, J., Imöhl, M., & Weiskirchen, R. (2018) · Laboratory Medicine · doi:10.1093/labmed/lmy045 · Cited by 13
Toulon, P. A., Appert‐Flory, A., Fischer, F., Buvat, S., Jambou, D., & Mahagne, M. (2019) · Thrombosis Research · doi:10.1016/j.thromres.2019.10.019 · Cited by 13
Ricós, C., Fernández–Calle, P., González-Lao, E., Simón, M., Díaz–Garzón, J., Boned, B., Marqués-García, F., Minchinela, J., Perich, C., Tejedor-Ganduxé, X., et al. (2020) · Advances in Laboratory Medicine / Avances en Medicina de Laboratorio · doi:10.1515/almed-2020-0029 · Cited by 13
“In 1999, the SEQC Analytical Quality Commission [5, 6] compiled all publications containing BV estimates in a database that was updated every two years until 2014 [7].”
MethodBojko, L., Ripka, G. D. P., Dionísio, L. M., Borges, C. L., Borato, D. C. K., & Moss, M. D. F. (2021) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/00045632211020029 · Cited by 13
“4%.(26) The Student’s t-test was used to evaluate the stratification of different groups according to the eGFR adopted for two antimicrobials dose adjustment (vancomycin and meropenem).”
MethodPoesen, K., Prins, M. D., den Berghe, G. V., Eldere, J. V., & Vanstapel, F. J. L. A. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2012-0848 · Cited by 13
Quality specifications for seminal parameters based on clinicians' opinions
de Aguilar, J. V. S., Álvarez‐Nieto, C., Morancho‐Zaragoza, J., Prats‐Gimenez, R., Ramírez, J. P., Fernández‐Pardo, E., Martínez, L., Clar, R. C., Duran, I. L., & Castilla, J. A. (2008) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510701496470 · Cited by 13
“However, the lack of a standard methodology used by those seeking to obtain the values of the components of biological variability, together with the fact that it is unclear whether biological variation components derived from healthy subjects can be extrapolated to pathological situations [5], limits their use.”
Background
Metadata
- Authors
- C. Ricós, V. A.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1999-01
- Volume
- 59
- Issue
- 7
- Pages
- 491-500
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2119950421
- Cited by
- 987
- References
- 6
- Citations by year
- 2026: 17 · 2025: 25 · 2024: 22 · 2023: 29 · 2022: 41 · 2021: 44 · 2020: 47 · 2019: 51 · 2018: 64 · 2017: 69 · 2016: 58 · 2015: 46 · 2014: 76 · 2013: 56 · 2012: 55
- FWCI
- 5.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Scandinavian Journal of Clinical and Laboratory Investigation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- biological variation, reference values, clinical laboratory testing, within-subject coefficient of variation, total error, bias and precision, disease states, hormones
- MeSH terms
- Humans, Quality Control, Clinical Laboratory Techniques, Databases as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.