Current databases on biological variation: pros, cons and progress
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A database with reliable information to derive definitive analytical quality specifications for a large number of clinical laboratory tests was prepared in this work. This was achieved by comparing and correlating descriptive data and relevant observations with the biological variation information, an approach that had not been used in the previous efforts of this type. The material compiled in the database was obtained from published articles referenced in BIOS, CURRENT CONTENTS, EMBASE and MEDLINE using "biological variation & laboratory medicine" as key words, as well as books and doctoral theses provided by their authors. The database covers 316 quantities and reviews 191 articles, fewer than 10 of which had to be rejected. The within- and between-subject coefficients of variation and the subsequent desirable quality specifications for precision, bias and total error for all the quantities accepted are presented. Sex-related stratification of results was justified for only four quantities and, in these cases, quality specifications were derived from the group with lower within-subject variation. For certain quantities, biological variation in pathological states was higher than in the healthy state. In these cases, quality specifications were derived only from the healthy population (most stringent). Several quantities (particularly hormones) have been treated in very few articles and the results found are highly discrepant. Therefore, professionals in laboratory medicine should be strongly encouraged to study the quantities for which results are discrepant, the 90 quantities described in only one paper and the numerous quantities that have not been the subject of study.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, the characteristics of the populations studied in the papers included in the historical estimates varied and include diseased (uncomplicated myocardial infarction, liver disease, type 1 diabetes mellitus) and non-diseased subjects [12, 16].”
From The European Biological Variation Study (EuBIVAS): a summary report (2022) · cites this paper as [12]
Citations
Cites
Generation and Application of Data on Biological Variation in Clinical Chemistry
Fraser, G. G., & Harris, E. K. (1989) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408368909106595 · Cited by 870
Fraser, C. G., Petersen, P. H., Ricós, C., & Haeckel, R. (1992) · PubMed · Cited by 125
The application of theoretical goals based on biological variation data in proficiency testing.
Cg, F. (1988) · PubMed · Cited by 119
(1997) · PubMed · Cited by 102
Biological variation in clinical chemistry. An update: collated data, 1988-1991.
Fraser, C. G. (1992) · PubMed · Cited by 91
The "index of fiduciality" proposed for use in evaluation and comparison of methods.
Fraser, C. G., & Browning, M. C. (1988) · Clinical Chemistry · doi:10.1093/clinchem/34.6.1356 · Cited by 13
Research works printed but not linked: 3
- Fraser CG, 1988, Arch Pathol Lab Med, 112, 404
- Fraser CG, 1992, Collated data, 1988-1991. Arch Pathol Lab Med, 116, 916
- Fraser CG, 1992, Eur J Clin Chem Clin Biochem, 30, 311
Cited by
Items 501–600 of 1,000
Impact of experimental hypercalcemia on routine haemostasis testing
Lippi, G., Salvagno, G. L., Brocco, G., Gelati, M., Danese, E., & Favaloro, E. J. (2017) · PLoS ONE · doi:10.1371/journal.pone.0175094 · Cited by 13
The effect of different forms of heparin on point-of-care blood gas analysis
Sandler, P., & Goldstein, L. N. (2018) · South African Medical Journal · doi:10.7196/samj.2018.v108i3.12626 · Cited by 13
Storage stability of commonly used haematological parameters at 33 °C
Jain, A., Jain, S., Singh, N., Aswal, P., Pal, S., Meinia, S. K., & Chowdhury, N. (2018) · Biochemia Medica · doi:10.11613/bm.2018.020901 · Cited by 13
Oris, C., Clavel, Y., Jabaudon, M., Pialat, A., Mohamed, H. A., Lioret, F., Sapin, V., & Bouvier, D. (2017) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2017.12.001 · Cited by 13
Peersman, N., Elslande, J. V., Lepage, Y., De Amicis, S., Desmet, K., & Vermeersch, P. (2020) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-1237 · Cited by 12
Greaves, R. F., Jolly, L., Hartmann, M. F., Ho, C. S., Kam, R. K. T., Joseph, J., Boyder, C., & Wudy, S. A. (2017) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2016-0394 · Cited by 12
“Prior to the commencement of the pilot in 2015, the following assessments occurred: (1) the RCPAQAP Endocrine program material was assessed by one laboratory, who performed DHT by LC-MS/MS, to determine if DHT was present in the material; (2) the peer-reviewed published literature was systemically searched in Medline,…”
MethodLinden, G., Charão, M. F., & Linden, R. (2023) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2023.110597 · Cited by 12
Cembrowski, G. S., Topping, K. A., Versluys, K. A., Tran, D., Malick, M., Holmes, D. T., & Clarke, G. (2015) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12443 · Cited by 12
Ahn, S., Cho, S.-M., Shin, H., & Lee, K. (2016) · Imsang byeong'ri wa jeongdo gwanri/Journal of laboratory medicine and quality assurance · doi:10.15263/jlmqa.2016.38.2.77 · Cited by 12
“The calculated differences of all parameters were compared with the current total allowable error based on biological variation [7,8], except for ESR and PDW because total allowable errors for them were not available.”
Qin, Y., Zhou, R., Wang, W., Yin, H., Yang, Y., Yue, Y., Tong, Q., Liu, L., Jin, Y., Shi, Y.-K., et al. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2017-1199 · Cited by 12
Regulatory context and validation of assays for clinical mass spectrometry proteomics (cMSP) methods
Hirtz, C., Bros, P., Brede, C., Lescuyer, P., Maceski, A. M., Vialaret, J., Delatour, V., & Lehmann, S. (2018) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2018.1470159 · Cited by 12
“logical variations [30], it has been proposed to define performance acceptance criteria using these data.”
BackgroundProposed Imprecision Quality Goals for Urinary Albumin/Creatinine Ratio
Ko, D., Lee, S. W., Hyun, J., Kim, H. S., Park, M.-J., & Shin, D. H. (2018) · Annals of Laboratory Medicine · doi:10.3343/alm.2018.38.5.420 · Cited by 12
Acute Kidney Injury Following Paracentesis Among Inpatients With Cirrhosis
Seethapathy, H. S., Sharma, S., Zhao, S. J., Chung, R. T., Connor, M. J., Jr., Leaf, D. E., & Allegretti, A. S. (2020) · Kidney International Reports · doi:10.1016/j.ekir.2020.05.014 · Cited by 12
Aplicación de Seis Sigma en el Laboratorio Clínico
Carchio, S. M., Cappella, A. C., Goedelmann, C. J., Pandolfo, M., & Bustos, D. (2019) · Acta bioquímica clínica latinoamericana/Acta bioquímica clínica latinoamericana · Cited by 12
Labile glycated hemoglobin: an underestimated laboratory marker of short term glycemia
Delanghe, J., Lambrecht, S., Fiers, T., & Speeckaert, M. M. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-1321 · Cited by 12
Flores, E., Leiva, M., Leiva‐Salinas, C., & Salinas, M. (2009) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2009.081 · Cited by 12
Diagnostic performance of the ARCHITECT C-Peptide immunoassay
Schultess, J., van Duren, C., Martens, M. F. W. C., Costa, M., Llop, T., Martí, T., Eppinger, M., Hausmann, M., Krack, W., & Dhein, J. (2009) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2009.185 · Cited by 12
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2013) · Indian Journal of Clinical Biochemistry · doi:10.1007/s12291-013-0319-y · Cited by 12
“fications for bias, derived from biological variation [19, 39].”
BackgroundMethodInfluentialSudmann, Å. A., Piehler, A. P., Klingenberg, O., & Urdal, P. (2015) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2014.1000370 · Cited by 12
Martín, B. B., Ayllón, O., Belmonte, M., Barceló, A., Vidal, R. E., Forteza-Rey, J., & Gutierrez, A. M. (2008) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2008.02.016 · Cited by 12
Urinary Albumin Detection: Comparison of Two Different Methods
Molinario, R., Pocino, K., Daloiso, P. D., Giannace, A., Spirito, G., Zuppi, C., & Antenucci, M. (2016) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.21952 · Cited by 12
“The between-run imprecision was compared with the current analytical quality specifications derived from biological variability (8).”
MethodIs the BD Barricor Tube the New Standard for Lithium Heparin Plasma?
Dimeski, G. (2018) · Developments in Clinical & Medical Pathology · doi:10.31031/dcmp.2018.01.000514 · Cited by 12
GUTIÉRREZ, A., Martínez-Serra, J., Martín, B. B., Sampol, A., VIÑAS, L., GONZÁLEZ, G., Bea, M. D., Amat, J. C., Martín‐Broto, J., RAMOS, R., et al. (2010) · International Journal of Laboratory Hematology · doi:10.1111/j.1751-553x.2010.01225.x · Cited by 12
“As CLIA’88 rules did not establish permissible error criteria for the CA 125, we use the error limits based on physiological variation of ±40% (Ricos et al., 1999).”
MethodStability of testosterone measured in male archival serum samples by two different methods
Gislefoss, R. E., Grimsrud, T. K., Høie, K., & Mørkrid, L. (2012) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2012.705888 · Cited by 12
Therapeutic Drug Monitoring of Levetiracetam: Comparison of a Novel Immunoassay With an HPLC Method
Bianchi, V., Arfini, C., & Vidali, M. (2014) · Therapeutic Drug Monitoring · doi:10.1097/ftd.0000000000000060 · Cited by 12
Use of haemolysis index to estimate potassium concentration in in-vitro haemolysed serum samples
Shepherd, J., Warner, M., Poon, P. L., & Kilpatrick, E. S. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.140 · Cited by 12
“8% (6), and therefore a CVA of no more than 2.”
BackgroundQuality requirements for quantitative clinical chemistry proteomics
(2014) · Translational Proteomics · doi:10.1016/j.trprot.2013.10.001 · Cited by 11
Talon, L., Fourneyron, V., Trapani, A., Pereira, B., Sinegre, T., & Lebreton, A. (2022) · Research and Practice in Thrombosis and Haemostasis · doi:10.1002/rth2.12660 · Cited by 11
Comparison of Complete Blood Count Parameters using EDTA, Sodium Citrate, and Heparin Anticoagulants
Putra, A. A. M. S., & Hernaningsih, Y. (2022) · Research Journal of Pharmacy and Technology · doi:10.52711/0974-360x.2022.00786 · Cited by 11
Influence of reduced centrifugation time on clinical chemistry analytes and literature review
Tantisaranon, P., Dumkengkhachornwong, K., & Hnoonual, A. (2023) · Turkish Journal of Biochemistry · doi:10.1515/tjb-2022-0211 · Cited by 11
Sewpersad, S., Chale-Matsau, B., & Pillay, T. S. (2024) · Clinica Chimica Acta · doi:10.1016/j.cca.2024.120006 · Cited by 11
Sigma metric analysis for performance of creatinine with fresh frozen serum
Kang, F., Zhang, C., Wang, W., & Wang, Z. (2015) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2015.1091494 · Cited by 11
“0% was chosen as the TEa according to the data from within-subject variation (CVI) and between-subject biological variation (CVG) [9,10], in consideration of the technological level in our country, as stated in ‘Analytical quality specifications for routine analytes in clinical biochemistry’ guideline published by the…”
MethodInfluentialSylte, M. S., Wentzel‐Larsen, T., & Bolann, B. J. (2012) · Clinica Chimica Acta · doi:10.1016/j.cca.2012.10.045 · Cited by 11
Association between physical fitness and mean platelet volume in professional soccer players
Alis, R., Sanchis‐Gomar, F., Ferioli, D., Torre, A. L., Bosio, A., Xu, J., Lombardi, G., Romagnoli, M., & Rampinini, E. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-1275 · Cited by 11
Khalil, H., Borai, A., Dakhakhni, M., Bahijri, S., Faizo, H., Bokhari, F. F., Ferns, G. A., & Mirza, A. A. (2021) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.23771 · Cited by 11
Palumbo, D., Giorni, A., Minocchi, R., Amendola, R., & Guidi, M. C. (2022) · Vibrational Spectroscopy · doi:10.1016/j.vibspec.2022.103408 · Cited by 11
Analytical Performance Specifications
Dalenberg, D. A., Schryver, P. G., & Klee, G. G. (2012) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2012.11.005 · Cited by 11
Biological Variation in Serum Activities of Three Hepatic Enzymes
Pagani, F., & Panteghini, M. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.2.355 · Cited by 11
Design of internal quality control for reference value studies
Westgard, J. O. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.141 · Cited by 11
“In addition to the quality goals in the Ricós’ database (3, 8), the US CLIA rules specify an allowable total error of 10% as the quality criterion in proficiency testing surveys, thus the selection of IQC procedures for an allowable total error has already been described in detail (9).”
BackgroundLima-Oliveira, G., Salvagno, G. L., Lippi, G., Brocco, G., Voi, M., Montagnana, M., Picheth, G., & Guidi, G. C. (2013) · Accreditation and Quality Assurance · doi:10.1007/s00769-013-0995-6 · Cited by 11
“These differences were compared with the current desirable quality specifications derived from biological variation [9, 10] according to the formulae:”
BackgroundSharma, R., Goyal, P., Chhapola, V., & Kumar, S. (2013) · Indian Journal of Critical Care Medicine · doi:10.4103/0972-5229.123443 · Cited by 11
“We compared the observed bias with the desirable bias specifi cations given by Ricos et al.[5] In our study, the observed bias exceeded the desirable bias for pCO2, Na+, K+, Cl− and Hb [Table 2].”
MethodResultInfluentialPetersen, P. H. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-1138 · Cited by 11
Measurement performance goals: How they can be estimated and a view to managing them
Kallner, A. (2010) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.3109/00365513.2010.493364 · Cited by 11
“Ricós C, Alvarez V, Cava F, Garcia-lario JV, Hernández A, [3] Jimenez CV, Minchinela J, Perich C, Simón M.”
BackgroundMethodInfluentialChristenson, R. H., Cervelli, D. R., Sterner, J., Bachmann, L. M., Rebuck, H., Gray, J., & Kelley, W. E. (2011) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2011.06.009 · Cited by 11
Flegar-Meštrić, Z., Perkov, S., & Radeljak, A. (2016) · World Journal of Methodology · doi:10.5662/wjm.v6.i1.93 · Cited by 11
Preanalytical investigations of phlebotomy: methodological aspects, pitfalls and recommendations
Ialongo, C., & Bernardini, S. (2017) · Biochemia Medica · doi:10.11613/bm.2017.020 · Cited by 12
“Lastly, the comparison of achieved bias with desirable values obtained from databases is another alternative to the use of statistically derived boundaries, but it does not take into consideration the actual imprecision of the methods used to perform experiments (86).”
MethodTang, N., Jin, X., Sun, Z., & Jian, C. (2017) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2016.1271906 · Cited by 11
“The effects of the interferent on conventional coagulation tests were evaluated according to both the total allowable error recommendations of Clinical Laboratory Improvement Amendments (CLIA’88) and limits derived from Biological Variation (Table 1) [11,12].”
MethodAn overview of EFLM harmonization activities in Europe
Kilpatrick, E. S., & Sandberg, S. (2018) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2018-0098 · Cited by 11
“[10], and it is planned to soon be hosted by the EFLM on its website.”
BackgroundAhmadizad, S., Rahmani, H., Khosravi, N., Falakdin, Z., Connes, P., & Daraei, A. (2020) · Clinical Hemorheology and Microcirculation · doi:10.3233/ch-200848 · Cited by 11
Variability of Thyroid Measurements from Ultrasound and Laboratory in a Repeated Measurements Study
Ittermann, T., Richter, A., Junge, M., Nauck, M. A., Petersmann, A., Jürgens, C., Below, H., Schmidt, C. O., & Völzke, H. (2020) · European Thyroid Journal · doi:10.1159/000507018 · Cited by 11
Hétu, P., Hobeila, S., Larivière, F., & Bélanger, M. (2020) · The Journal of Applied Laboratory Medicine · doi:10.1093/jalm/jfaa111 · Cited by 11
“Data were analyzed using weighted Deming regression analysis using Analyze-it Software for Microsoft Excel, and comparison acceptability criteria was based on mean bias, correlation coefficient, and clinically allowable total error calculated from biological variation data (5).”
MethodHaysom, L., Williams, R., Hodson, E. M., Lopez‐Vargas, P. A., ROY, L. P., Lyle, D. M., & Craig, J. C. (2009) · Pediatric Nephrology · doi:10.1007/s00467-008-0988-6 · Cited by 11
“All positive and negative control calibrations fell within the acceptable cutoffs designated by the manufacturer (Bayer HealthCare, Bayer Corporation, Elkhart, IN, USA), based upon national and international precision goals derived from biological variation and international consensus data on performance criteria [19,…”
MethodCanalías, F., García, E. P., & Sánchez, M. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.09.029 · Cited by 11
Joseph, J. I. (2013) · Journal of Diabetes Science and Technology · doi:10.1177/193229681300700519 · Cited by 11
Estimation of uncertainty in measurements in the clinical laboratory
Kallner, A. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0749 · Cited by 11
“The metric “total error” (TE), defined as the “net effect of method bias and imprecision” includes both types of error in a single metric [8, 9].”
BackgroundAnderson, L., Razavi, M., Skates, S. J., Anderson, N. G., & Pearson, T. W. (2016) · Bioanalysis · doi:10.4155/bio-2016-0088 · Cited by 11
Şeneş, M., Bolat, S., Sürer, H., Samsum, E. Ç., & Yücel, D. (2024) · Biochemia Medica · doi:10.11613/bm.2024.020701 · Cited by 10
Harmonization of laboratory results by data adjustment in multicenter clinical trials
Lee, S. G., Chung, H., Park, J. B., Park, H., & Lee, E. H. (2017) · The Korean Journal of Internal Medicine · doi:10.3904/kjim.2017.034 · Cited by 10
“The clinically acceptable total error, including precision and bias, is reported in international guidelines, the literature, and reports from external quality assessment organizations [11-13].”
BackgroundVercruysse, K., Lambrecht, S., & Oyaert, M. (2021) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0866 · Cited by 10
Hollestelle, M. J., Kristoffersen, A. H., Idema, R. N., Meijer, P., Sandberg, S., de Maat, M. P. M., & Aarsand, A. K. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-1207 · Cited by 10
Wang, W., Zhang, Z., Zhang, C., Zhao, H., Yuan, S., Liu, J., Dong, N., Wang, Z., & Kang, F. (2023) · Annals of Laboratory Medicine · doi:10.3343/alm.2023.0236 · Cited by 10
Claerhout, H., Prins, M. D., Mesotten, D., den Berghe, G. V., Mathieu, C., Eldere, J. V., & Vanstapel, F. J. L. A. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-1289 · Cited by 10
Kaiser, T., Kinny‐Köster, B., Gnewuch, C., Karailieva, D., Kiehntopf, M., Keßler, A., Ritter-Sket, C., Schmidt, M. B., Brand, K., Thiery, J., et al. (2017) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2017.04.002 · Cited by 10
Bolodeoku, J. (2018) · Biomedical Journal of Scientific & Technical Research · doi:10.26717/bjstr.2018.09.001822 · Cited by 10
“Biological variation of PSA has been reported to be up to 18% and the desirable acceptable imprecision for PSA is 9% [13,14], therefore this level of imprecision is acceptable.”
BackgroundJekarl, D. W., Choi, H., Kim, E. S., Lee, S., Park, H., Kim, M., & Kim, Y. (2019) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2019.1627575 · Cited by 10
Ilardo, C., Lancien, A., & Barthes, J. (2020) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2020.1855363 · Cited by 10
“%) as a limit [4] and to validate the corrected potassium approach described by Martinez-Morillo and Alvarez [2].”
ResultStability of serum biochemical markers during standard long-term storage and with a single thawing
Kozlova, V. A., Metelskaya, V. A., Pokrovskaya, M. S., Efimova, I. A., Litinskaya, O. A., Kutsenko, V. A., Yarovaya, E. B., Shalnova, S. A., & Drapkina, O. M. (2020) · CARDIOVASCULAR THERAPY AND PREVENTION · doi:10.15829/1728-8800-2020-2736 · Cited by 11
A practical approach example to measurement uncertainty: Evaluation of 26 immunoassay parameters
Kurtulmuş, Y., Tan, R., & Yilmaz, M. (2022) · Biochemia Medica · doi:10.11613/bm.2022.030705 · Cited by 10
“Ricos - Ricos’s databases on biologic variation (17).”
BackgroundLow serum creatine kinase activity is associated with worse outcome in critically ill patients
de Moortel, L. V., Speeckaert, M. M., Fiers, T., Oeyen, S. G., Decruyenaere, J. M. A., & Delanghe, J. (2014) · Journal of Critical Care · doi:10.1016/j.jcrc.2014.03.010 · Cited by 11
“A period of 5 days was chosen in order to take into account the sampling frequency (1 sampling/d), the biological half-life of the enzyme in plasma, and the intraindividual biological variation of the analyte (±23% for CK activity) [21].”
MethodEvaluation of the Konelab 20XT clinical chemistry analyzer
Stojanović, N., Rogić, D., & Stavljenić-Rukavina, A. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2005.111 · Cited by 10
Shinya, S., Akimoto, M., Hayakawa, A., Hokazono, E., & Osawa, S. (2011) · Clinica Chimica Acta · doi:10.1016/j.cca.2011.09.021 · Cited by 10
“examinationmethod, but those values in the tolerance level of the accuracy that was calculated fromwithin-individual biological variation and between-individual biological variation of healthy subjects [13].”
BackgroundXia, C., Liu, O., Wang, L., & Xu, G. (2012) · Annals of Laboratory Medicine · doi:10.3343/alm.2012.32.4.243 · Cited by 10
“The allowable bias is determined on the basis of biological variability, an excess of which is considered clinically significant and would compromise the interpretation of results for diagnostic or monitoring decisions [20, 21].”
BackgroundThe quality of diagnostic testing may be impaired during shipment of lithium-heparin gel tubes
Rin, G. D., & Lippi, G. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0527 · Cited by 10
Spurious elevation of serum potassium concentration measured in samples with thrombocytosis
Roccaforte, V., Daves, M., Alfreijat, A., Riva, M., Leitner, M., Filippi, S., Angaroni, G., Montani, F., Platzgummer, S., & Lippi, G. (2016) · Diagnosis · doi:10.1515/dx-2016-0008 · Cited by 10
A Multicenter Reference Intervals Study for Specific Proteins in China
Qin, X., Tang, G., Qiu, L., Li, P. C., Xia, L., Chen, M., Tao, Z., Li, S., Liu, M., Wang, L., et al. (2015) · Medicine · doi:10.1097/md.0000000000002211 · Cited by 10
Effect of delayed centrifugation of whole blood on serum samples stability
Daves, M., Roccaforte, V., Giacomi, M., Riva, M., Leitner, M., Platzgummer, S., Goetsch, G., & Lippi, G. (2017) · La Rivista Italiana della Medicina di Laboratorio - Italian Journal of Laboratory Medicine · doi:10.1007/s13631-017-0146-x · Cited by 10
“increasingly used for establishing sample quality [8], it can”
MethodManagement of electrolyte disorders: also the method matters!
Delanghe, J. (2018) · Acta Clinica Belgica · doi:10.1080/17843286.2018.1474018 · Cited by 10
Petrides, V., & Schneider, S. (2018) · Biochemia Medica · doi:10.11613/bm.2018.020903 · Cited by 10
Giannoli, J., Albarède, S., Avellan, T., Bouilloux, J., Cartier, R., Cohen, R., Colard, N., Essemilaire, L., Galinier, J.-L., Kuentz, M., et al. (2019) · Annales de biologie clinique · doi:10.1684/abc.2019.1481 · Cited by 10
Perović, A., Žarak, M., Bratičević, M. N., & Dumić, J. (2020) · European Journal of Applied Physiology · doi:10.1007/s00421-020-04395-5 · Cited by 10
“The mean difference (%) was also estimated according to the intra-subject biological variation derived from Westgard database (Ricos et al. 1999).”
MethodFlegar-Meštrić, Z., Perkov, S., Šimonović, B., & Juretić, D. (2009) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2010.054 · Cited by 10
“In addition, they need to demonstrate that using controlled pre-analytical conditions, their analytical performance meets the recommended performance goal of -10% total error based on biological variability and clinical requirements (15, 26, 27).”
BackgroundÜstündag-Budak, Y., & Huysal, K. (2017) · JOURNAL OF CLINICAL AND DIAGNOSTIC RESEARCH · doi:10.7860/jcdr/2017/23486.9259 · Cited by 10
Heparin and citrate additive carryover during blood collection
Keppel, M. H., Auer, S., Lippi, G., Meyer, A., Cornes, M. P., Felder, T. K., Oberkofler, H., Mrazek, C., Haschke‐Becher, E., & Cadamuro, J. (2019) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2019-0433 · Cited by 10
“Appropriate CVA values were calculated from daily QC-measurements and data on parameter specific CVi values were gathered from the Ricos database [18].”
MethodEvaluation of HemoCue Glucose Meter (201+)
Fogh‐Andersen, N. (2004) · Point of Care The Journal of Near-Patient Testing & Technology · doi:10.1097/00134384-200412000-00008 · Cited by 10
Establishment of outcome-related analytic performance goals
Klee, G. G. (2011) · Annales de biologie clinique · doi:10.1684/abc.2011.0541 · Cited by 9
“This hierarchical list of strategies was endorsed by an international conference, Strategies to Set Global Quality Specifications in Laboratory Medicine, and has been termed “The Stockholm Conference Hierarchy” (4, 5 ).”
BackgroundRomanelli, P., Bertazzolo, W., Prisciandaro, A., Leone, A., Bonfanti, U., & Paltrinieri, S. (2024) · Pathogens · doi:10.3390/pathogens13040289 · Cited by 9
Analytical evaluation of the clinical chemistry analyzer Olympus AU2700 plus
Juriček, J., Đerek, L., Unić, A., Serdar, T., Marijančević, D., Živković, M., & Romić, Ž. (2010) · Biochemia Medica · doi:10.11613/bm.2010.043 · Cited by 9
Roccaforte, V., Sciarini, F., Proserpio, V., Buonocore, R., Zavaroni, E., Burati, S., Bussetti, M., Liuzzi, G., Russo, R. M., Porreca, W. P., et al. (2020) · Hematology Transfusion and Cell Therapy · doi:10.1016/j.htct.2020.01.004 · Cited by 9
Control interno de la calidad – bases del pasado, situación presente y futuras tendencias
Ricós, C., Fernández–Calle, P., Perich, C., & Westgard, J. O. (2022) · Advances in Laboratory Medicine / Avances en Medicina de Laboratorio · doi:10.1515/almed-2022-0028 · Cited by 9
“Esta nueva base de datos ha sido elaborada a partir de una revisión exhaustiva de los artículos incluidos en la primera base de datos [19, 20] y de la aplicación de una estrategia de búsqueda eficaz, de forma que se recopilara el mayor número posible de artículos sobre variación biológica.”
BackgroundNourse, P. J., McCulloch, M., Coetzee, A., Bunchman, T., Picca, S., Rusch, J. A., Brooks, A., Heydenrych, H., & Morrow, B. M. (2023) · Pediatric Nephrology · doi:10.1007/s00467-022-05852-3 · Cited by 9
“9%, which is within allowable limits of imprecision according to biological variation [12].”
BackgroundJensen, C. Z., Nygaard, B., Faber, J. O., Pedersen, P. L., Larsen, M. K., Kanters, J. K., Poulsen, H. E., Kellogg, M. D., & Ellervik, C. (2023) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2022-0845 · Cited by 9
The implementation of a system for managing analytical quality in networked laboratories
Jassam, N., Lindsay, C., Harrison, K., Thompson, D. I., Bosomworth, M. P., & Barth, J. H. (2011) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2010.010005 · Cited by 9
Ercan, M., Oğuz, E. F., Akbulut, E. D., Yilmaz, M., & Turhan, T. (2018) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.22427 · Cited by 9
Lie, M., & Thorstensen, K. (2018) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2018.1480060 · Cited by 9
“4% in line with the desirable specification for inaccuracy [10].”
BackgroundA simplified, rapid LC-MS/MS assay for serum and salivary creatinine
Bernstone, L., Jayanti, A., & Keevil, B. G. (2018) · Clinical mass spectrometry · doi:10.1016/j.clinms.2018.11.004 · Cited by 9
Diurnal rhythm in clinical chemistry: An underrated source of variation
Hassan, M. A. E., DELVIN, E. E., Elnenaei, M. O., & Hoffman, B. (2018) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408363.2018.1519522 · Cited by 10
Ittermann, T., Dörr, M., Markus, M. R. P., Nauck, M. A., Jürgens, C., Schipf, S., Schmidt, C. O., Völzke, H., & Richter, A. (2022) · Nutrition Metabolism and Cardiovascular Diseases · doi:10.1016/j.numecd.2022.03.022 · Cited by 9
Bender, B. F., Johnson, N. J., Berry, J. A., Frazier, K. M., & Bender, M. B. (2022) · Frontiers in Sports and Active Living · doi:10.3389/fspor.2022.921418 · Cited by 9
Tighter precision target required for lactate testing in patients with lactic acidosis
Versluys, K. A., Redel, S., Kunst, A., Rimkus, M., Chin, D. N., Tran, D. V., Holmes, D. T., & Cembrowski, G. S. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0685 · Cited by 9
Stove, V. V., Wuyts, B., & Delanghe, J. (2007) · Clinical Chemistry · doi:10.1373/clinchem.2006.081414 · Cited by 9
Metadata
- Authors
- C. Ricós, V. A.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1999-01
- Volume
- 59
- Issue
- 7
- Pages
- 491-500
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2119950421
- Cited by
- 987
- References
- 6
- Citations by year
- 2026: 17 · 2025: 25 · 2024: 22 · 2023: 29 · 2022: 41 · 2021: 44 · 2020: 47 · 2019: 51 · 2018: 64 · 2017: 69 · 2016: 58 · 2015: 46 · 2014: 76 · 2013: 56 · 2012: 55
- FWCI
- 5.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Scandinavian Journal of Clinical and Laboratory Investigation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- biological variation, reference values, clinical laboratory testing, within-subject coefficient of variation, total error, bias and precision, disease states, hormones
- MeSH terms
- Humans, Quality Control, Clinical Laboratory Techniques, Databases as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.