Current databases on biological variation: pros, cons and progress
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A database with reliable information to derive definitive analytical quality specifications for a large number of clinical laboratory tests was prepared in this work. This was achieved by comparing and correlating descriptive data and relevant observations with the biological variation information, an approach that had not been used in the previous efforts of this type. The material compiled in the database was obtained from published articles referenced in BIOS, CURRENT CONTENTS, EMBASE and MEDLINE using "biological variation & laboratory medicine" as key words, as well as books and doctoral theses provided by their authors. The database covers 316 quantities and reviews 191 articles, fewer than 10 of which had to be rejected. The within- and between-subject coefficients of variation and the subsequent desirable quality specifications for precision, bias and total error for all the quantities accepted are presented. Sex-related stratification of results was justified for only four quantities and, in these cases, quality specifications were derived from the group with lower within-subject variation. For certain quantities, biological variation in pathological states was higher than in the healthy state. In these cases, quality specifications were derived only from the healthy population (most stringent). Several quantities (particularly hormones) have been treated in very few articles and the results found are highly discrepant. Therefore, professionals in laboratory medicine should be strongly encouraged to study the quantities for which results are discrepant, the 90 quantities described in only one paper and the numerous quantities that have not been the subject of study.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, the characteristics of the populations studied in the papers included in the historical estimates varied and include diseased (uncomplicated myocardial infarction, liver disease, type 1 diabetes mellitus) and non-diseased subjects [12, 16].”
From The European Biological Variation Study (EuBIVAS): a summary report (2022) · cites this paper as [12]
Citations
Cites
Generation and Application of Data on Biological Variation in Clinical Chemistry
Fraser, G. G., & Harris, E. K. (1989) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408368909106595 · Cited by 870
Fraser, C. G., Petersen, P. H., Ricós, C., & Haeckel, R. (1992) · PubMed · Cited by 125
The application of theoretical goals based on biological variation data in proficiency testing.
Cg, F. (1988) · PubMed · Cited by 119
(1997) · PubMed · Cited by 102
Biological variation in clinical chemistry. An update: collated data, 1988-1991.
Fraser, C. G. (1992) · PubMed · Cited by 91
The "index of fiduciality" proposed for use in evaluation and comparison of methods.
Fraser, C. G., & Browning, M. C. (1988) · Clinical Chemistry · doi:10.1093/clinchem/34.6.1356 · Cited by 13
Research works printed but not linked: 3
- Fraser CG, 1988, Arch Pathol Lab Med, 112, 404
- Fraser CG, 1992, Collated data, 1988-1991. Arch Pathol Lab Med, 116, 916
- Fraser CG, 1992, Eur J Clin Chem Clin Biochem, 30, 311
Cited by
Items 201–300 of 1,000
PINTO, R. D., VIAZZI, F., Pontremoli, R., Ferri, C., Carubbi, F., & RUSSO, E. (2021) · Panminerva Medica · doi:10.23736/s0031-0808.21.04357-3 · Cited by 40
Interference studies: focus on blood cell lysates preparation and testing.
Lippi, G. (2012) · PubMed · Cited by 40
External Quality Assessment Schemes: need for recognised requirements
Sciacovelli, L., Secchiero, S., Zardo, L., & Plebani, M. (2001) · Clinica Chimica Acta · doi:10.1016/s0009-8981(01)00521-6 · Cited by 40
Arnaud, J., Touvier, M., Galan, P., Andriollo-Sanchez, M., Ruffieux, D., Roussel, A. M., Herçberg, S., & Favier, A. E. (2010) · European Journal of Clinical Nutrition · doi:10.1038/ejcn.2010.118 · Cited by 40
“As serum zinc inter-individual variability is higher than 15% (Giles et al., 1994; Hashim et al., 1996; Ricos et al., 1999), these studies must be interpreted with caution.”
BackgroundLund, F., Petersen, P. H., Fraser, C. G., & Sölétormos, G. (2014) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563214534636 · Cited by 40
Arnaud, J., Weber, J., Weykamp, C. W., Parsons, P. J., Angerer, J., Mairiaux, E., Mazarrasa, O., Valkonen, S., Menditto, A., Patriarca, M., et al. (2008) · Clinical Chemistry · doi:10.1373/clinchem.2008.108142 · Cited by 40
Lippi, G., Ippolito, L., & Favaloro, E. J. (2013) · SLAS TECHNOLOGY · doi:10.1177/2211068213491747 · Cited by 39
“The results of PT, APTT, fibrinogen, and plasma indices obtained on aliquots with increasing concentration of cellfree hemoglobin (H1, H2, and H3), total bilirubin (I1, I2, and I3), and triglycerides (L1, L2, L3, and L4) were compared with those obtained on the baseline aliquots (H0, I0, and L0, respectively) by Stude…”
MethodMeasuring calprotectin in plasma and blood with a fully automated turbidimetric assay
Åsberg, A., Løfblad, L., Felic, A., & Hov, G. G. (2019) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365513.2018.1550810 · Cited by 39
“6% is indicated for the neutrophil count [22], and our corresponding figure for B-calprotectin, 4.”
BackgroundInfluence of in vitro hemolysis on hematological testing on Advia 2120
Lippi, G., Musa, R., Avanzini, P., Aloe, R., Pipitone, S., & Sandei, F. (2011) · International Journal of Laboratory Hematology · doi:10.1111/j.1751-553x.2011.01378.x · Cited by 39
“able bias derived from biological variation (Ricos et al., 1999).”
BackgroundInfluentialRiond, B., Weissenbacher, S., Hofmann‐Lehmann, R., & Lutz, H. (2011) · Veterinary Clinical Pathology · doi:10.1111/j.1939-165x.2011.00372.x · Cited by 39
Haeckel, R., & Wosniok, W. (2011) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2011.116 · Cited by 39
“For certain quantities, biological variation in pathological states was higher than in the healthy state (29).”
BackgroundEngelberger, R. P., Limacher, A., Kucher, N., Baumann, F., Silbernagel, G., Benghozi, R., Do, D.-D., Willenberg, T., & Baumgärtner, I. (2015) · Clinica Chimica Acta · doi:10.1016/j.cca.2015.05.003 · Cited by 39
Elimination of the venous stasis error for routine coagulation testing by transillumination
Lima-Oliveira, G., Salvagno, G. L., Lippi, G., Montagnana, M., Scartezini, M., Picheth, G., & Guidi, G. C. (2011) · Clinica Chimica Acta · doi:10.1016/j.cca.2011.04.008 · Cited by 38
“25 (CVw2 +CVg2)1/2 where CVw and CVg are within- and between-subject CVs [38].”
BackgroundInfluentialReal-life persistence and tolerability with dimethyl fumarate
Sejbæk, T., Nybo, M., Petersen, T., & Illés, Z. (2018) · Multiple Sclerosis and Related Disorders · doi:10.1016/j.msard.2018.05.007 · Cited by 38
Magkos, F., Fabbrini, E., Korenblat, K., Okunade, A. L., Patterson, B. W., & Klein, S. (2011) · International Journal of Obesity · doi:10.1038/ijo.2010.265 · Cited by 35
van Berkel, M., & Scharnhorst, V. (2010) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2011.047 · Cited by 38
Kristensen, G. B. B., Rustad, P., Berg, J. P., & Aakre, K. M. (2016) · Clinical Chemistry · doi:10.1373/clinchem.2016.258962 · Cited by 37
Thyagarajan, B., Howard, A. G., Durazo-Arvizu, R., Eckfeldt, J. H., Gellman, M. D., Kim, R. S., Liu, K., Mendez, A. J., Penedo, F. J., Talavera, G. A., et al. (2016) · Clinica Chimica Acta · doi:10.1016/j.cca.2016.10.019 · Cited by 37
“DISCUSSION This study found that the between-individual variability was substantially higher in the HCHS/SOL population as compared to published literature [4] including NHANES [17] while the within-individual variability was comparable to other studies.”
ResultBakan, E., Polat, H., Özarda, Y., Öztürk, N., Baygutalp, N. K., Umudum, F. Z., & Bakan, N. (2016) · Biochemia Medica · doi:10.11613/bm.2016.023 · Cited by 37
“and between-day CVA for all analytes, listed in Table 1, did not exceed the desirable limits reported (14).”
Backgroundvan der Veen, A., van Faassen, M. H. J. R., de Jong, W. H. A., van Beek, A. P., Dijck-Brouwer, J., & Kema, I. P. (2019) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2019.03.013 · Cited by 38
Haematologic indices in hepatitis B virus-related liver disease
Mao, W., & Wu, J. (2019) · Clinica Chimica Acta · doi:10.1016/j.cca.2019.10.007 · Cited by 38
Goel, P., Malik, G., Prasad, S., Rani, I., Manhas, S., & Goel, K. (2020) · Practical Laboratory Medicine · doi:10.1016/j.plabm.2020.e00195 · Cited by 37
Saumoy, M., Sánchez‐Quesada, J. L., Ordóñez‐Llanos, J., & Podzamczer, D. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10163456 · Cited by 37
Nieto, J. E., Dechant, J. E., le Jeune, S. S., & Snyder, J. R. (2014) · Veterinary Surgery · doi:10.1111/j.1532-950x.2014.12231.x · Cited by 37
Henderson, C. M., Bollinger, J. G., Becker, J. O., Wallace, J. M., Laha, T. J., MacCoss, M. J., & Hoofnagle, A. N. (2017) · PROTEOMICS - CLINICAL APPLICATIONS · doi:10.1002/prca.201600103 · Cited by 37
“9 for apoA-I, apoB, and HbA1c, respectively [36, 37].”
BackgroundBaadenhuijsen, H., Kuypers, A. W. H. M., Weykamp, C. W., Cobbaert, C. M., & Jansen, R. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2005.052 · Cited by 37
Yun, Y.-M., Botelho, J. C., Chandler, D. W., Katayev, A., Roberts, W. L., Stanczyk, F. Z., Vesper, H. W., Nakamoto, J. M., Garibaldi, L., Clarke, N. J., et al. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2012.186569 · Cited by 36
Biological variation – reliable data is essential
Aarsand, A. K., Røraas, T., & Sandberg, S. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-1141 · Cited by 36
“At the Stockholm conference in 1999, Carmen Ricos and the Analytical Quality Commission of the Spanish Society of Clinical Chemistry presented an overview of estimates of BV for a large number of constituents [1].”
BackgroundRepeating Tests: Different Roles in Research Studies and Clinical Medicine
Monach, P. A. (2012) · Biomarkers in Medicine · doi:10.2217/bmm.12.57 · Cited by 36
Systematic review of serum steroid reference intervals developed using mass spectrometry
Tavita, N., & Greaves, R. F. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.07.002 · Cited by 36
Venturelli, M., Cè, E., Limonta, E., Schena, F. F., Caimi, B., Carugo, S., Veicsteinas, A., & Esposito, F. (2015) · AGE · doi:10.1007/s11357-015-9835-4 · Cited by 37
“6 (mg/dl), respectively (Ricos et al. 1999).”
Ćelap, I., Vukasović, I., Juričić, G., & Šimundić, A.-M. (2017) · Biochemia Medica · doi:10.11613/bm.2017.030502 · Cited by 36
“The significance of the result of the measurement uncertainty estimation can be assessed by comparing the result with the specifications defined according to models proposed in the Milan conference, or with the total allowable error (TEa) based on biological variation components as proposed by some authors (31-33).”
MethodPetersen, P. H., & Klee, G. G. (2013) · Clinica Chimica Acta · doi:10.1016/j.cca.2013.12.014 · Cited by 36
Biological Variation of Serum Amyloid A in Healthy Subjects
d’Eril, G. M., Anesi, A., Maggiore, M., & Leoni, V. (2001) · Clinical Chemistry · doi:10.1093/clinchem/47.8.1498 · Cited by 36
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2013) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0b013e32835b72ea · Cited by 33
Evaluation of the analytical performances of the novel Beckman Coulter AU5800
Lippi, G., Dipalo, M., Musa, R., Avanzini, P., Ferrarini, C., Pattini, A., & Aloe, R. (2012) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2012.01.015 · Cited by 35
“Final results were expressed in terms of coefficient of variation (CV) and compared with the current analytical quality specifications for the total allowable error derived from biological variability [4].”
BackgroundSchouwers, S., Brandt, I., Willemse, J. L., Regenmortel, N. V., Uyttenbroeck, W., Wauters, A., & Neels, H. M. (2011) · Clinica Chimica Acta · doi:10.1016/j.cca.2011.08.037 · Cited by 35
Pediatric reference intervals determined in ambulatory and hospitalized children and juveniles
Heiduk, M., Päge, I., Kliem, C., Abicht, K., & Klein, G. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.06.021 · Cited by 35
Smets, E. M. L., Dijkstra-Lagemaat, J. E., & Blankenstein, M. A. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.076 · Cited by 35
“082 b-hCG, mg/l IFMA (4) 20 86 29 200 0 (y1–2) 0.”
BackgroundInfluentialLarge scale biobanking of blood — The importance of high density sample processing procedures
Malm, J., Végvári, Á., Rezeli, M., Upton, P., Danmyr, P., Nilsson, R. E., Steinfelder, E., & Marko‐Varga, G. (2012) · Journal of Proteomics · doi:10.1016/j.jprot.2012.05.003 · Cited by 34
Vitamin D, PTH, and calcium in relation to survival following prostate cancer
Brändstedt, J., Almquist, M., Manjer, J., & Malm, J. (2016) · Cancer Causes & Control · doi:10.1007/s10552-016-0740-7 · Cited by 34
Simard, T., Jung, R. G., Labinaz, A., Faraz, M. A., Ramirez, F. D., Santo, P. D., Perry‐Nguyen, D., Pitcher, I., Motazedian, P., Gaudet, C., et al. (2019) · Journal of the American Heart Association · doi:10.1161/jaha.119.012228 · Cited by 34
Semeraro, A., Altieri, I., Patriarca, M., & Menditto, A. (2009) · Journal of Chromatography B · doi:10.1016/j.jchromb.2009.02.063 · Cited by 34
Steen, G., Klerk, A., van der Laan, K., & Eppens, E. F. (2011) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/acb.2010.010187 · Cited by 34
Drieghe, S., Alsaadi, H., Tugirimana, P. L., & Delanghe, J. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0669 · Cited by 34
Lund, F., Petersen, P. H., Fraser, C. G., & Sölétormos, G. (2014) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563214555163 · Cited by 34
“85%.(3) Using a bidirectional probability of 95%.”
MethodStability of common biochemistry analytes in equine blood stored at room temperature
Rendle, D. I., Heller, J., Hughes, K., Innocent, G. T., & Durham, A. E. (2009) · Equine Veterinary Journal · doi:10.2746/042516409x370928 · Cited by 34
van Rossum, H. H., & Kemperman, H. (2016) · Clinica Chimica Acta · doi:10.1016/j.cca.2016.03.008 · Cited by 34
Selection and Analytical Evaluation of Methods—With Statistical Techniques
Línnet, K., & Boyd, J. C. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4160-6164-9.00002-0 · Cited by 34
Incorrect order of draw could be mitigate the patient safety: a phlebotomy management case report
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Picheth, G., & Guidi, G. C. (2013) · Biochemia Medica · doi:10.11613/bm.2013.026 · Cited by 33
“In any case clinically signifi cant diff erences were observed for potassium, total calcium and free calcium only in the blood of the dedicated syringe when mean percent diff erences were compared with RCV derived from biological variation (Table 1) (28).”
MethodTo mix or not to mix venous blood samples collected in vacuum tubes?
Parenmark, A., & Landberg, E. (2011) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2011.705 · Cited by 33
“0% as suggested on the basis of biological variation (2).”
BackgroundEffects of vigorous mixing of blood vacuum tubes on laboratory test results
Lima-Oliveira, G., Lippi, G., Salvagno, G. L., Montagnana, M., Gelati, M., Volanski, W., Boritiza, K. C., Picheth, G., & Guidi, G. C. (2013) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2012.10.033 · Cited by 33
“Finally, the bias from procedure 1 and procedure 2 was compared with the current desirable quality specifications for bias (B), derived from biological variation [29].”
MethodOverview of the in vitro stability of commonly measured vitamins and carotenoids in whole blood
Cuerq, C., Peretti, N., Chikh, K., Mialon, A., Guillaumont, M., Drai, J., & Blond, E. (2014) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563214542471 · Cited by 33
Kestens, L., & Mandy, F. (2016) · Cytometry Part B Clinical Cytometry · doi:10.1002/cyto.b.21400 · Cited by 33
Lima-Oliveira, G., Guidi, G. C., Salvagno, G. L., Brocco, G., Danese, E., & Lippi, G. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.07.007 · Cited by 33
Tran, M. T. C., Hoang, K., & Greaves, R. F. (2016) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2016.08.008 · Cited by 33
The use of biomarkers to describe plasma‐, red cell‐, and blood volume from a simple blood test
Lobigs, L., Sottas, P., Bourdon, P., Nikolovski, Z., El-Gingo, M., Varamenti, E., Peeling, P., Dawson, B., & Schumacher, Y. (2017) · American journal of hematology/oncology · doi:10.1002/ajh.24577 · Cited by 28
“The 18 serum-based biomarkers described above were chosen as they are known to present with low within-subject variations [12].”
BackgroundEvaluation of di‐potassium and tri‐potassium EDTA evacuated tubes for routine haematological testing
Mehmood, R., Muhammed, R. K., Hussain, S., & Sana, A. (2017) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.22188 · Cited by 33
Wittenmeier, E., Bellosevich, S., Mauff, S., Schmidtmann, I. M., Eli, M., Pestel, G., & Noppens, R. R. (2015) · Pediatric Anesthesia · doi:10.1111/pan.12683 · Cited by 32
Biological Variations of Hematologic Parameters Determined by UniCel DxH 800 Hematology Analyzer
Zhang, P., Tang, H., Chen, K., Chen, Y., & Xu, D. (2013) · Archives of Pathology & Laboratory Medicine · doi:10.5858/arpa.2012-0377-oa · Cited by 32
“As shown in Table 1, we achieved similar CVI and CVG for the conventional erythrocyte or platelet parameters compared with published data.(1,2) The analytic variations (CVA) of DxH 800 for these parameters appeared smaller than or comparable to those found in previous studies.”
ResultHuss, L., Butt, S. T., Borgquist, S., Almquist, M., Malm, J., & Manjer, J. (2014) · Cancer Causes & Control · doi:10.1007/s10552-014-0413-3 · Cited by 32
“Contrary to PTH, total serum calcium has been shown to have a low intraindividual variation over short as well as long time [47, 48].”
BackgroundSureda-Vives, M., Morell‐García, D., Alaejos, A. R., Amado, L. V., Robles, J., & Bauçà, J. M. (2017) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2017.03.019 · Cited by 32
Serum symmetric dimethylarginine and creatinine in Birman cats compared with cats of other breeds
Paltrinieri, S., Giraldi, M., Prolo, A., Scarpa, P., Piseddu, E., Beccati, M., Graziani, B., & Bo, S. (2017) · Journal of Feline Medicine and Surgery · doi:10.1177/1098612x17734066 · Cited by 32
Biological variation of thyroid autoantibodies and thyroglobulin
Jensen, E. A., Petersen, P. H., Blaabjerg, O., & Hegedűs, L. D. (2007) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2007.185 · Cited by 32
Hemólisis en las muestras para diagnóstico
Rioja, R. G., Kirchner, M. J. A., Funes, V. Á., Barba, N., Cortés, M., Díaz, M. A. L., & Martínez-Brú, C. (2009) · Revista del Laboratorio Clínico · doi:10.1016/j.labcli.2009.08.002 · Cited by 32
Reference change values: how useful are they?
Omar, F., van der Watt, G. F., & Pillay, T. S. (2008) · Journal of Clinical Pathology · doi:10.1136/jcp.2007.054833 · Cited by 32
“albumin in myocardial infarction).(4) 10 14 15 Using these CVIs inappropriately to determine RCVs in these conditions would yield false positives, meaning that RCVs should best not be calculated in acute disease states using CVIs from existing databases.”
BackgroundInfluentialBiological Variation in Tests of Hemostasis
Banfi, G., & FABBRO, M. D. (2009) · Seminars in Thrombosis and Hemostasis · doi:10.1055/s-0029-1214155 · Cited by 32
“A value of CVi of 4% for prothrombin time is reported in a database.(8) This value was used by Kouri et al(9) for a comparison with the combined preanalytical and analytical uncertainty of measurement, which they observed to be higher (5.”
BackgroundMethodUse of biochemical markers of bone turnover in the management of postmenopausal osteoporosis
Camacho, P. M., & Lopez, N. A. (2008) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2008.310 · Cited by 32
Six Sigma Metrics and Quality Control in Clinical Laboratory
Goel, S. S., Saini, R., Singh, S. B., Aggarwal, O., & Goel, A. K. (2014) · International Journal of Medical Research and Review · doi:10.17511/ijmrr.2014.i02.20 · Cited by 31
Cembrowski, G. S., Tran, D. V., & Higgins, T. N. (2010) · cclm · doi:10.1515/cclm.2010.286 · Cited by 30
Comparison of the EPOC and i‐ STAT analysers for canine blood gas and electrolyte analysis
West, E., Bardell, D., & Senior, M. (2014) · Journal of Small Animal Practice · doi:10.1111/jsap.12177 · Cited by 31
Biological variation of free plasma amino acids in healthy individuals
Corte, Z., & Venta, R. (2009) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2010.008 · Cited by 31
The Evaluation of Analytical Performance of Immunoassay Tests by Using Six-Sigma Method
Nar, R., & Emekli, D. İ. (2017) · Journal of Medical Biochemistry · doi:10.1515/jomb-2017-0026 · Cited by 31
“The TEa values of several clinical chemistry analytes have been reported and they are accessible (7, 8).”
BackgroundMethodBrowne, R. W., & Whitcomb, B. W. (2010) · Epidemiology · doi:10.1097/ede.0b013e3181ce9a61 · Cited by 31
“For clinical analytes, these specifications are often established from the experimental determination of the components of biologic variation and continuously updated databases are available.(8,9) Using the values from LOD experiments (described later) estimates of imprecision (SDS), bias (difference between the repli…”
MethodPreparation of a Quality Sample: Effect of Centrifugation Time on Stat Clinical Chemistry Testing
Lippi, G., Salvagno, G. L., Montagnana, M., & Guidi, G. C. (2007) · Laboratory Medicine · doi:10.1309/d8tjcaruw575cxyh · Cited by 31
Could light meal jeopardize laboratory coagulation tests?
Lima-Oliveira, G., Salvagno, G. L., Lippi, G., Danese, E., Gelati, M., Montagnana, M., Picheth, G., & Guidi, G. C. (2014) · Biochemia Medica · doi:10.11613/bm.2014.036 · Cited by 30
“Turbidity index NA NA NA NA 9 (8-14) 14 (11-20) 35.”
BackgroundAnalytical and clinical guidelines on neonatal bilirubinemia
Mailloux, A., Cortey, A., Delatour, V., Poupon, C., Rota, M., Schmitt, F., & Vaubourdolle, M. (2020) · Annales de biologie clinique · doi:10.1684/abc.2020.1571 · Cited by 30
Pawlik-Sobecka, L., Sołkiewicz, K., Kokot, I., Kiraga, A., Płaczkowska, S., Schlichtinger, A. M., & Kratz, E. M. (2020) · Diagnostics · doi:10.3390/diagnostics10010051 · Cited by 30
“, first published in 1999 [18] and updated in 2014 [19].”
BackgroundMethodCantero, M., Redondo, M., Martín, E., Callejón, G., & Hortas, M. L. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-1053 · Cited by 30
Lima-Oliveira, G., Salvagno, G. L., Danese, E., Favaloro, E. J., Guidi, G. C., & Lippi, G. (2014) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12301 · Cited by 30
Variability of Serum Markers of Erythropoiesis during 6 Days of Racing in Highly Trained Cyclists
Voss, S. C., Alsayrafi, M., Bourdon, P. C., Klodt, F., Nonis, D., Hopkins, W. G., & Schumacher, Y. O. (2013) · International Journal of Sports Medicine · doi:10.1055/s-0033-1345177 · Cited by 30
Fernandez, P., Llopis, M. A., Perich, C., Alsina, M. J., Álvarez, V., Biosca, C., Busquets, G., Doménech, M. V., Rioja, R. G., Llovet, I., et al. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0935 · Cited by 30
“The cut-off point to define hemolysis interference for a specific test in each laboratory was established, when the percentage surpassed the bias derived from biological variation database [13, 14].”
BackgroundMethodLobigs, L. M., Sottas, P., Bourdon, P. C., Николовски, З., El‐Gingo, M., Varamenti, E., Peeling, P., DAWSON, B. T., & Schumacher, Y. O. (2017) · Drug Testing and Analysis · doi:10.1002/dta.2219 · Cited by 30
Greaves, R. F. (2012) · Europe PMC (PubMed Central) · Cited by 30
Quality leadership and quality control.
Badrick, T. C. (2003) · PubMed · Cited by 30
Collective opinion paper on findings of the 2009 convocation of experts on quality control
Burnett, D. A., Ceriotti, F., Cooper, G., Parvin, C. A., Plebani, M., & Westgard, J. O. (2009) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2010.001 · Cited by 30
“For collecting reliable data on biological variation, well-defined protocols should be fulfilled, in particular: • Health status of the subject must be known • Predefined exclusion criteria must be applied • Pre-analytical factors must be standardized and minimized • Analytical variability should be minimized • Define…”
Influence of the centrifuge time of primary plasma tubes on routine coagulation testing
Lippi, G., Salvagno, G. L., Montagnana, M., Manzato, F., & Guidi, G. C. (2007) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0b013e3281eec945 · Cited by 30
Shephard, M., & Gill, J. (2005) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1258/0004563053857806 · Cited by 30
Plebani, M., & Lippi, G. (2011) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2011.751 · Cited by 30
Analytical bias of automated immunoassays for six serum steroid hormones assessed by LC-MS/MS
Debeljak, Ž., Marković, I., Šerić, V., Horvat, V., Mandić, S., Mandić, D., Lukić, I., & Pavela, J. (2020) · Biochemia Medica · doi:10.11613/bm.2020.030701 · Cited by 29
“Changes in steroid hormone concentration of less than 20%, as expected during the hormone suppression therapy, exceed the steroid hormone biological variation and may affect the patient’s treatment (11).”
BackgroundHickman, P. E., Koerbin, G., Potter, J. M., Glasgow, N., Cavanaugh, J. A., Abhayaratna, W. P., West, N. P., & Glasziou, P. (2020) · Clinical Chemistry · doi:10.1093/clinchem/hvaa208 · Cited by 29
Lombardi, G., Lanteri, P., Fiorella, P., Simonetto, L., Impellizzeri, F. M., Bonifazi, M., Banfi, G., & Locatelli, M. (2013) · PLoS ONE · doi:10.1371/journal.pone.0063092 · Cited by 29
“Importantly, the changes in the most relevant parameters (both statistically and physiologically) often fell outside the range of biological variability, in terms of intra-individual variability [14,15].”
BackgroundMethodPrioritizing Risk Analysis Quality Control Plans Based on Sigma-metrics
Westgard, S. A. (2012) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2012.11.008 · Cited by 29
Ames, M. K., Atkins, C. E., Lantis, A. C., & Brunnen, J. Z. (2016) · Journal of the Renin-Angiotensin-Aldosterone System · doi:10.1177/1470320316633897 · Cited by 29
Association of abdominal aortic aneurysm diameter with insulin resistance index
Lareyre, F., Moratal, C., Zereg, E., Carboni, J., Panaïa‐Ferrari, P., Bayer, P., Jean‐Baptiste, E., Hassen‐Khodja, R., Chinetti, G., & Raffort, J. (2018) · Biochemia Medica · doi:10.11613/bm.2018.030702 · Cited by 29
“For all assays, quality controls fell within limits defined by the manufacturer and current guidelines (26,27).”
van der Heijden, C., Roosens, L., Cluckers, H., Craenenbroeck, A. H. V., & Peeters, B. (2019) · Clinica Chimica Acta · doi:10.1016/j.cca.2019.06.025 · Cited by 29
Osawa, S., Sugo, S., Yoshida, T., Yamaoka, T., & Nomura, F. (2006) · Clinica Chimica Acta · doi:10.1016/j.cca.2005.09.031 · Cited by 29
Klee, G. G., & Westgard, J. O. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4160-6164-9.00008-1 · Cited by 29
Creatinine determination in serum by capillary electrophoresis
Paroni, R. C., Fermo, I., Cighetti, G., Ferrero, C. A., Carobene, A., & Ceriotti, F. (2004) · Electrophoresis · doi:10.1002/elps.200305687 · Cited by 29
Comparison of Different Immunoassays for CA 19-9
Stern, P., Friedecky, B., Bartos, V., Springer, D., Vávrová, J., Uhrová, J., Rozprímová, L., Zima, T., & Palička, V. (2001) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2001.205 · Cited by 29
Metadata
- Authors
- C. Ricós, V. A.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1999-01
- Volume
- 59
- Issue
- 7
- Pages
- 491-500
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2119950421
- Cited by
- 987
- References
- 6
- Citations by year
- 2026: 17 · 2025: 25 · 2024: 22 · 2023: 29 · 2022: 41 · 2021: 44 · 2020: 47 · 2019: 51 · 2018: 64 · 2017: 69 · 2016: 58 · 2015: 46 · 2014: 76 · 2013: 56 · 2012: 55
- FWCI
- 5.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Scandinavian Journal of Clinical and Laboratory Investigation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- biological variation, reference values, clinical laboratory testing, within-subject coefficient of variation, total error, bias and precision, disease states, hormones
- MeSH terms
- Humans, Quality Control, Clinical Laboratory Techniques, Databases as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.