Current databases on biological variation: pros, cons and progress
The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Abstract
A database with reliable information to derive definitive analytical quality specifications for a large number of clinical laboratory tests was prepared in this work. This was achieved by comparing and correlating descriptive data and relevant observations with the biological variation information, an approach that had not been used in the previous efforts of this type. The material compiled in the database was obtained from published articles referenced in BIOS, CURRENT CONTENTS, EMBASE and MEDLINE using "biological variation & laboratory medicine" as key words, as well as books and doctoral theses provided by their authors. The database covers 316 quantities and reviews 191 articles, fewer than 10 of which had to be rejected. The within- and between-subject coefficients of variation and the subsequent desirable quality specifications for precision, bias and total error for all the quantities accepted are presented. Sex-related stratification of results was justified for only four quantities and, in these cases, quality specifications were derived from the group with lower within-subject variation. For certain quantities, biological variation in pathological states was higher than in the healthy state. In these cases, quality specifications were derived only from the healthy population (most stringent). Several quantities (particularly hormones) have been treated in very few articles and the results found are highly discrepant. Therefore, professionals in laboratory medicine should be strongly encouraged to study the quantities for which results are discrepant, the 90 quantities described in only one paper and the numerous quantities that have not been the subject of study.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Moreover, the characteristics of the populations studied in the papers included in the historical estimates varied and include diseased (uncomplicated myocardial infarction, liver disease, type 1 diabetes mellitus) and non-diseased subjects [12, 16].”
From The European Biological Variation Study (EuBIVAS): a summary report (2022) · cites this paper as [12]
Citations
Cites
Generation and Application of Data on Biological Variation in Clinical Chemistry
Fraser, G. G., & Harris, E. K. (1989) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408368909106595 · Cited by 870
Fraser, C. G., Petersen, P. H., Ricós, C., & Haeckel, R. (1992) · PubMed · Cited by 125
The application of theoretical goals based on biological variation data in proficiency testing.
Cg, F. (1988) · PubMed · Cited by 119
(1997) · PubMed · Cited by 102
Biological variation in clinical chemistry. An update: collated data, 1988-1991.
Fraser, C. G. (1992) · PubMed · Cited by 91
The "index of fiduciality" proposed for use in evaluation and comparison of methods.
Fraser, C. G., & Browning, M. C. (1988) · Clinical Chemistry · doi:10.1093/clinchem/34.6.1356 · Cited by 13
Research works printed but not linked: 3
- Fraser CG, 1988, Arch Pathol Lab Med, 112, 404
- Fraser CG, 1992, Collated data, 1988-1991. Arch Pathol Lab Med, 116, 916
- Fraser CG, 1992, Eur J Clin Chem Clin Biochem, 30, 311
Cited by
Sacks, D. B., Arnold, M., Bakris, G. L., Bruns, D. E., Horvath, A. R., Kirkman, M. S., Lernmark, A., Metzger, B. E., & Nathan, D. M. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.161596 · Cited by 1,360
Red blood cell distribution width: A simple parameter with multiple clinical applications
Salvagno, G. L., Sanchis-Gomar, F., Picanza, A., & Lippi, G. (2015) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408363.2014.992064 · Cited by 1,236
“As reported by Ricos et al.(4), the within-subject and betweensubject biologic variations are 3.”
InfluentialMyers, G. L. (2006) · Clinical Chemistry · doi:10.1373/clinchem.2005.0525144 · Cited by 1,232
“b CVg, mean interindividual biological variation (136).”
Sacks, D. B., Bruns, D. E., Goldstein, D. E., Maclaren, N. K., McDonald, J. M., & Parrott, M. (2002) · Clinical Chemistry · doi:10.1093/clinchem/48.3.436 · Cited by 1,130
Diagnosis and Monitoring of Hepatic Injury. I. Performance Characteristics of Laboratory Tests
Dufour, D. R., Lott, J. A., Nolte, F. S., Gretch, D. R., Koff, R. S., & Seeff, L. B. (2000) · Clinical Chemistry · doi:10.1093/clinchem/46.12.2027 · Cited by 571
Haemolysis: an overview of the leading cause of unsuitable specimens in clinical laboratories
Lippi, G., Blanckaert, N., Bonini, P., Green, S., Kitchen, S., Palicka, V., Vassault, A. J., & Plebani, M. (2008) · Clinical Chemistry and Laboratory Medicine · doi:10.1515/cclm.2008.170 · Cited by 466
“Either the total allowable error or the analytical quality specifications for desirable bias, which are both derived from intraand inter-individual variations (43), can be used to identify the acceptable bias from results obtained in reference, non-haemolytic specimens (44).”
Dehydration: Physiology, Assessment, and Performance Effects
Cheuvront, S. N., & Kenefick, R. W. (2014) · Comprehensive Physiology · doi:10.1002/cphy.c130017 · Cited by 461
Biological variation and diagnostic accuracy of dehydration assessment markers
Cheuvront, S. N., Ely, B. R., Kenefick, R. W., & Sawka, M. N. (2010) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.2010.29490 · Cited by 367
Serum Creatinine: Not So Simple!
Delanaye, P., Cavalier, E., & Pottel, H. (2017) · Nephron · doi:10.1159/000469669 · Cited by 349
Influence of hemolysis on routine clinical chemistry testing
Lippi, G., Luca Salvagno, G., Montagnana, M., Brocco, G., & Cesare Guidi, G. (2006) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2006.054 · Cited by 344
“Values are compared with current analytical quality specifications for desirable bias (15).”
BackgroundMethodStability study of 81 analytes in human whole blood, in serum and in plasma
Oddoze, C., Lombard, E., & Portugal, H. (2012) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2012.01.012 · Cited by 303
Newsome, B. B. (2008) · Archives of Internal Medicine · doi:10.1001/archinte.168.6.609 · Cited by 302
Buttarello, M. (2016) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12500 · Cited by 295
“One source of variability of clinical laboratory results (besides preanalytic and analytic variations) is the intraindividual variation around the homeostatic setting point (41).”
BackgroundLipemia: causes, interference mechanisms, detection and management
Nikolac, N. (2014) · Biochemia Medica · doi:10.11613/bm.2014.008 · Cited by 290
“5 x CVw as desirable specification for imprecision (54).”
BackgroundEvaluation of Biomarkers and Surrogate Endpoints in Chronic Disease
(2010) · National Academies Press eBooks · doi:10.17226/12869 · Cited by 276
Pfeiffer, C. M., & Looker, A. C. (2017) · The American Journal of Clinical Nutrition · doi:10.3945/ajcn.117.155887 · Cited by 257
Aarsand, A. K., Røraas, T., Fernandez-Calle, P., Ricos, C., Díaz-Garzón, J., Jonker, N., Perich, C., González-Lao, E., Carobene, A., Minchinela, J., et al. (2018) · Clinical Chemistry · doi:10.1373/clinchem.2017.281808 · Cited by 233
Hemolyzed specimens: a major challenge for emergency departments and clinical laboratories
Lippi, G., Plebani, M., Di Somma, S., & Cervellin, G. (2011) · Critical Reviews in Clinical Laboratory Sciences · doi:10.3109/10408363.2011.600228 · Cited by 226
Effects of Low-Dose Prednisone on Bone Metabolism
Ton, F. N., Gunawardene, S. C., Lee, H., & Neer, R. M. (2005) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.041125 · Cited by 223
“Day-to-day variation in the placebo group was comparable with a priori estimates.((23,24)) This, plus our methods of recruitment, allows our results to be generalized.”
ResultInherent biological variation and reference values
Fraser, C. G. (2004) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2004.128 · Cited by 222
A practical guide to validation and verification of analytical methods in the clinical laboratory
Pum, J. K. W. (2019) · Advances in clinical chemistry · doi:10.1016/bs.acc.2019.01.006 · Cited by 217
Approved IFCC recommendation on reporting results for blood glucose (abbreviated)
D'Orazio, P. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2005.051979 · Cited by 208
Bone turnover markers in the management of postmenopausal osteoporosis
Brown, J. P., Albert, C., Nassar, B. A., Adachi, J. D., Cole, D., Davison, K. S., Dooley, K. C., Don-Wauchope, A., Douville, P., Hanley, D. A., et al. (2009) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2009.04.001 · Cited by 204
Within-subject biological variation in disease: collated data and clinical consequences
Ricós, C., Iglesias, N., García-Lario, J.-V., Simón, M., Cava, F., Hernández, A., Perich, C., Minchinela, J., Alvarez, V., Doménech, M.-V., et al. (2007) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/000456307780945633 · Cited by 193
Clinical Utility of Reticulocyte Parameters
Piva, E., Brugnara, C., Spolaore, F., & Plebani, M. (2015) · Clinics in Laboratory Medicine · doi:10.1016/j.cll.2014.10.004 · Cited by 188
International Council for Standardization in Haematology, W. G., Briggs, C., Culp, N., Davis, B., d'Onofrio, G., Zini, G., Machin, S. J., & the International Council for Standardization of Haematology (2014) · International Journal of Laboratory Hematology · doi:10.1111/ijlh.12201 · Cited by 185
Internal quality control: planning and implementation strategies
Westgard, J. O. (2003) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/000456303770367199 · Cited by 172
Ricós, C., Cava, F., García‐Lario, J. V., Hernández, A., Iglesias, N., Jiménez, C. V., Minchinela, J., Perich, C., Simón, M., Domenech, M. V., et al. (2004) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510410004885 · Cited by 168
A Practical Guide to Basic Laboratory Andrology
Björndahl, L., Mortimer, D., Barratt, C. L. R., Castilla, J. A., Menkveld, R., Kvist, U., Alvarez, J. G., & Haugen, T. B. (2010) · Cambridge University Press eBooks · doi:10.1017/cbo9780511729942 · Cited by 146
Liquid chromatography–tandem mass spectrometry applications in endocrinology
Kushnir, M. M., Rockwood, A. L., & Bergquist, J. (2010) · Mass Spectrometry Reviews · doi:10.1002/mas.20264 · Cited by 159
“Thus, targeted values for sensitivity, accuracy, precision, and the analytical measurement range (AMR) should be based on the clinical needs of each individual marker (Ricos et al., 1999; http://www.westgard.com/biodatabase1.htm, 2008).”
BackgroundDiagnosis of Wilson's Disease: A Comprehensive Review
Mak, C. M., & Lam, C.-W. (2008) · Critical Reviews in Clinical Laboratory Sciences · doi:10.1080/10408360801991055 · Cited by 146
A checklist for critical appraisal of studies of biological variation
Bartlett, W. A., Braga, F., Carobene, A., Coşkun, A., Prusa, R., Fernandez-Calle, P., Røraas, T., Jonker, N., Sandberg, S., & Variati, O. B. O. T. B. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-1127 · Cited by 151
“Attempts to make BVD accessible to laboratory medicine specialists have resulted in the delivery of a biological variation data base by Ricós and colleagues which is currently hosted online [14–16].”
BackgroundNeufeld, L. M., Larson, L. M., Kurpad, A. V., Mburu, S., Martorell, R., & Brown, K. H. (2019) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.14139 · Cited by 144
Küme, T., Sağlam, B., Ergon, C., & Şişman, A. R. (2017) · Journal of Clinical Laboratory Analysis · doi:10.1002/jcla.22168 · Cited by 141
Rai, A. J., & Vitzthum, F. (2006) · Expert Review of Proteomics · doi:10.1586/14789450.3.4.409 · Cited by 138
Røraas, T., Petersen, P. H., & Sandberg, S. (2012) · Clinical Chemistry · doi:10.1373/clinchem.2012.187781 · Cited by 134
“However, very few papers and databases on SDWP present CIs for the estimated values of the components (4, 5, 12, 13), but there are some exceptions (14, 15).”
Skates, S. J., Gillette, M. A., LaBaer, J., Carr, S. A., Anderson, L., Liebler, D. C., Ransohoff, D. F., Rifai, N., Kondratovich, M., Težak, Ž., et al. (2013) · Journal of Proteome Research · doi:10.1021/pr400132j · Cited by 132
“To derive a statistical model for the biological CV as a function of concentration, we estimated biological CVs from a database on normal biological variation for laboratory tests and their normal ranges [25].”
MethodAnalytical Sigma metrics: A review of Six Sigma implementation tools for medical laboratories
Westgard, S. A., Bayat, H., & Westgard, J. O. (2018) · Biochemia Medica · doi:10.11613/bm.2018.020502 · Cited by 132
Stability of selected serum proteins after long-term storage in the Janus Serum Bank
Gislefoss, R. E., Grimsrud, T. K., & Mørkrid, L. (2009) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2009.121 · Cited by 131
“For the components not represented in Ricós’ (8) table, we used an updated version from 2008 (9).”
BackgroundInfluentialHens, K. A., Berth, M., Armbruster, D., & Westgard, S. A. (2014) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-1090 · Cited by 128
Non-Invasive Measurement of Hemoglobin: Assessment of Two Different Point-of-Care Technologies
Gayat, É., Aulagnier, J., Matthieu, E., Boisson, M., & Fischler, M. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030065 · Cited by 128
“The coefficient of variation is defined as the ratio of the standard deviation of the absolute difference between the duplicates divided by the mean of the average value of the duplicate [10].”
BackgroundCole, T. G., Contois, J. H., Csako, G., McConnell, J. P., Remaley, A. T., Devaraj, S., Hoefner, D. M., Mallory, T., Sethi, A. A., & Warnick, G. R. (2013) · Clinical Chemistry · doi:10.1373/clinchem.2012.196733 · Cited by 122
Paroni, R. C., Ceriotti, F., Galanello, R., Leoni, G., Panico, A., Scurati, E., Paleari, R., Chemello, L., Quaino, V., Scaldaferri, L., et al. (2007) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2007.08.001 · Cited by 122
“6% [20]) was found to be met in one of our specimen (i.”
BackgroundPiva, E., Brugnara, C., Chiandetti, L., & Plebani, M. (2010) · cclm · doi:10.1515/cclm.2010.292 · Cited by 106
“Biological variation should be considered when counting reticulocytes (39).”
Lippi, G., Pavesi, F., Bardi, M., & Pipitone, S. (2014) · Clinical Biochemistry · doi:10.1016/j.clinbiochem.2014.06.003 · Cited by 121
Performance Evaluation of a Noninvasive Hemoglobin Monitoring Device
Gayat, É., Bodin, A., Sportiello, C., Boisson, M., Dreyfus, J., Mathieu, E., & Fischler, M. (2011) · Annals of Emergency Medicine · doi:10.1016/j.annemergmed.2010.11.032 · Cited by 118
“4%.(6) Although there are some advantages in using point-of-care testing, they should not be obtained at too high a risk.”
BackgroundMethodStandardization of testosterone measurements in humans
Vesper, H. W., & Botelho, J. C. (2010) · The Journal of Steroid Biochemistry and Molecular Biology · doi:10.1016/j.jsbmb.2010.03.032 · Cited by 113
Lacher, D. A., Hughes, J. P., & Carroll, M. D. (2005) · Clinical Chemistry · doi:10.1373/clinchem.2004.039354 · Cited by 112
“NHANES III provides a better estimate of CVg than do other short-term local studies because the NHANES III sample was nationally representative (1, 12, 13).”
Backgroundvan Deventer, H. E., Miller, W. G., Myers, G. L., Sakurabayashi, I., Bachmann, L. M., Caudill, S. P., Dziekonski, A., Edwards, S., Kimberly, M. M., Korzun, W. J., et al. (2011) · Clinical Chemistry · doi:10.1373/clinchem.2010.154773 · Cited by 112
“0,98 0,78 0,90 0,62 0,80 0,07 (2,71) 0,26 (10,05) 0,38 (14,69) 0,21 (8,12) 0,18 (6,96) 1,07 (0,90 a 1,23) 0,58 (0,37 a 0,79) 1,07 (0,02 a 2,11) 0,91 (0,82 a 1,00) 0,62 (0,00 a 1,24) -0,07 (-0,20 a 0,07), 0,38 (0,19 a 0,57), -0,12 (-1,05 a 0,80), 0,06 (0,02 a 0,09), 0,45 (-0,12 a 1,03), -2,71 (-7,73 a 2,71) 14,69 (-7,3…”
Almquist, M., Bondeson, A., Bondeson, L., Malm, J., & Manjer, J. (2010) · International Journal of Cancer · doi:10.1002/ijc.25215 · Cited by 110
Quality control review: implementing a scientifically based quality control system
Westgard, J. O., & Westgard, S. A. (2016) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563215597248 · Cited by 109
Biological variation database: structure and criteria used for generation and update
Perich, C., Minchinela, J., Ricós, C., Fernández-Calle, P., Alvarez, V., Doménech, M. V., Simón, M., Biosca, C., Boned, B., García-Lario, J. V., et al. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-0739 · Cited by 98
Nordin, G., Mårtensson, A., Swolin, B., Sandberg, S., Christensen, N. J., Thorsteinsson, V., Franzson, L., Kairisto, V., & Savolainen, E. ‐. (2004) · Scandinavian Journal of Clinical and Laboratory Investigation · doi:10.1080/00365510410002797 · Cited by 98
Beulens, J. W. J., Hart, H. E., Kuijs, R., Kooijman-Buiting, A. M. J., & Rutten, G. E. H. M. (2014) · Acta Diabetologica · doi:10.1007/s00592-014-0597-8 · Cited by 109
“The variance in measurements can be up to 30 % in each direction [30].”
Insulin-like growth factor-I (IGF-I) and clinical nutrition
Livingstone, C. (2013) · Clinical Science · doi:10.1042/cs20120663 · Cited by 94
Fong, S., Pabis, K., Latumalea, D., Dugersuren, N., Unfried, M., Tolwinski, N., Kennedy, B., & Gruber, J. (2024) · Nature Aging · doi:10.1038/s43587-024-00646-8 · Cited by 76
Budak, Y., Huysal, K., & Polat, M. (2012) · BMC Anesthesiology · doi:10.1186/1471-2253-12-17 · Cited by 99
“8% [15], any bias exhibited by either method did not exceed the acceptable level of inaccuracy [15].”
BackgroundEvaluation of mean platelet volume with four hematological analyzers
Lippi, G., Pavesi, F., & Pipitone, S. (2014) · Blood Coagulation & Fibrinolysis · doi:10.1097/mbc.0000000000000220 · Cited by 96
Interference of Blood Cell Lysis on Routine Coagulation Testing
Lippi, G., Montagnana, M., Salvagno, G. L., & Guidi, G. C. (2006) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2006-130-181-iobclo · Cited by 95
Castilla, J. A., Álvarez‐Nieto, C., de Aguilar, J. V. S., González-Varea, C., Gonzalvo, M. C., & Martínez, L. (2005) · Human Reproduction · doi:10.1093/humrep/dei423 · Cited by 94
Diabetes Is the Main Factor Accounting for Hypomagnesemia in Obese Subjects
Lecube, A., Baena‐Fustegueras, J. A., Fort, J. M., Pelegrí, D., Hernández, C., & Simó, R. (2012) · PLoS ONE · doi:10.1371/journal.pone.0030599 · Cited by 88
“These results can not be attributed to magnesium biological variation and/or analytical imprecision [34].”
BackgroundMiller, W. G., Myers, G. L., Ashwood, E. R., Killeen, A. A., Wang, E., Ehlers, G. W., Hassemer, D., Lo, S. F., Seccombe, D., Siekmann, L., et al. (2008) · Archives of Pathology & Laboratory Medicine · doi:10.5858/2008-132-838-sotait · Cited by 87
Schindler, E. I., Szymanski, J. J., Hock, K. G., Geltman, E. M., & Scott, M. G. (2015) · Clinical Chemistry · doi:10.1373/clinchem.2015.246553 · Cited by 87
“7 (38–79) 21 (8) 18 15 (23) 6 94 (55) 91”
Huber, M., Kepesidis, K. V., Voronina, L., Božić‐Iven, M., Trubetskov, M. K., Harbeck, N., Krausz, F., & Žigman, M. (2021) · Nature Communications · doi:10.1038/s41467-021-21668-5 · Cited by 86
The European Biological Variation Study (EuBIVAS): a summary report
Carobene, A., Aarsand, A. K., Bartlett, W. A., Coskun, A., Diaz-Garzon, J., Fernandez-Calle, P., Guerra, E., Jonker, N., Locatelli, M., Plebani, M., et al. (2022) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2021-0370 · Cited by 84
“characteristics of the populations studied in the papers included in the historical estimates varied and include diseased (uncomplicated myocardial infarction, liver disease, type 1 diabetes mellitus) and non-diseased subjects [12, 16].”
BackgroundMethodInfluentialCarobene, A., Braga, F., Roraas, T., Sandberg, S., & Bartlett, W. A. (2013) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2013-0096 · Cited by 84
“[ 5 ] made available a database comprising of a collection of data including BV of biochemical and haematological analytes.”
MethodPoint-of-Care Testing and Creatinine Measurement.
Shephard, M. D. S. (2011) · Europe PMC (PubMed Central) · Cited by 83
Haemoglobin A1c: Analysis and Standardisation
John, W. G. (2003) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2003.184 · Cited by 82
Chhapola, V., Kanwal, S. K., & Brar, R. (2014) · Annals of Clinical Biochemistry International Journal of Laboratory Medicine · doi:10.1177/0004563214553438 · Cited by 82
“These acceptable clinical limits of laboratory analytes have been provided by Ricos et al.(13) and Westgard QC.”
MethodInfluence of short-term venous stasis on clinical chemistry testing
Lippi, G., Salvagno, G. L., Montagnana, M., Brocco, G., & Guidi, G. C. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2005.146 · Cited by 81
“The precision between measurements, estimated by Bland-Altman plots and the 95% agreement interval in the set of differences between samples, exceeded the current analytical quality specifications for desirable bias (9) for albumin, calcium and potassium after 1-min stasis, and for ALT, albumin, calcium, chloride, tot…”
MethodManaging quality vs. measuring uncertainty in the medical laboratory
Westgard, J. O. (2010) · cclm · doi:10.1515/cclm.2010.024 · Cited by 63
Hedengran, K. K., Andersen, M. R., Stender, S., & Szecsi, P. B. (2016) · Obstetrics and Gynecology International · doi:10.1155/2016/3561675 · Cited by 80
“the intraindividual variation of Ddimer in a nonpregnant population is about 23% [16].”
BackgroundEstablishment of Outcome-Related Analytic Performance Goals
Klee, G. G. (2010) · Clinical Chemistry · doi:10.1373/clinchem.2009.133660 · Cited by 77
Reliability of biological variation data available in an online database: need for improvement
Carobene, A. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2014-1133 · Cited by 76
Cadamuro, J., Mrazek, C., Leichtle, A. B., Kipman, U., Felder, T. K., Wiedemann, H., Oberkofler, H., Fiedler, M., & Haschke‐Becher, E. (2017) · Biochemia Medica · doi:10.11613/bm.2018.010704 · Cited by 76
“After approval by the local ethics committee (Protocol number 415-E/2028/9-2016) and a written informed consent of every participant, three Lithium-Heparin gel tubes (LiHepGel) (BD Vacutainer, LH PSTTM II, 16x100mm, 8ml REF:367378), three serum gel tubes (BD Vacutainer, SSTTM II Advance, 16x100mm, 8ml REF: 367953) and…”
MethodGovernance of preanalytical variability: Travelling the right path to the bright side of the moon?
Lippi, G. (2009) · Clinica Chimica Acta · doi:10.1016/j.cca.2009.03.026 · Cited by 75
Gupta, S., Richards, S. M., Amaravadi, L. S., Piccoli, S. P., Desilva, B. S., Pillutla, R. C., Stevenson, L. F., Mehta, D. S., Carrasco‐Triguero, M., Neely, R. J., et al. (2017) · Bioanalysis · doi:10.4155/bio-2017-4974 · Cited by 75
Lippi, G., Salvagno, G. L., Solero, G. P., Franchini, M., & Guidi, G. C. (2005) · Journal of Laboratory and Clinical Medicine · doi:10.1016/j.lab.2005.08.004 · Cited by 74
Components of biological variation of biochemical markers of bone turnover in Paget’s bone disease
Alvarez, L., Ricós, C., Peris, P., Guañabens, N., Monegal, A., Pons, F., & Ballesta, A. M. (2000) · Bone · doi:10.1016/s8756-3282(00)00279-9 · Cited by 74
Theodorsson, E., Magnusson, B., & Leito, I. (2014) · Bioanalysis · doi:10.4155/bio.14.249 · Cited by 73
“This uncertainty consists of measurement uncertainty (bias and imprecision), on uncertainty in the sampling and sample handling and on the spontaneous biological variation [41] of the component in the healthy subjects and patients as their homeostatic systems and the possible disease processes influence the concentrat…”
BackgroundThe diagnosis and investigation of adrenal insufficiency in adults
Wallace, I., Cunningham, S., & Lindsay, J. (2009) · Annals of Clinical Biochemistry: International Journal of Laboratory Medicine · doi:10.1258/acb.2009.009101 · Cited by 68
Jørgensen, L. G. M., Fredholm, L., Petersen, P. H., Hey, H., Munkholm, P., & Brandslund, I. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2005.073 · Cited by 73
Test result variation and the quality of evidence-based clinical guidelines
Fraser, C. G. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2003.12.032 · Cited by 73
Goodall, I., Colman, P. G., Schneider, H. G., McLean, M., & Barker, G. (2007) · Clinical Chemical Laboratory Medicine · doi:10.1515/cclm.2007.158 · Cited by 64
Preanalytical variability in laboratory testing: influence of the blood drawing technique
Lippi, G., Salvagno, G. L., Brocco, G., & Guidi, G. C. (2005) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2005.055 · Cited by 56
Influence of a light meal on routine haematological tests.
(2010) · PubMed Central · doi:10.2450/2009.0142-09 · Cited by 71
Lippi, G., Salvagno, G. L., Danese, E., Tarperi, C., Guidi, G. C., & Schena, F. F. (2014) · Advances in Hematology · doi:10.1155/2014/192173 · Cited by 71
Lacher, D. A., Hughes, J. P., & Carroll, M. D. (2010) · PubMed · Cited by 71
Sample stability for complete blood cell count using the Sysmex XN haematological analyser.
Daves, M., Zagler, E. M., Cemin, R., Gnech, F., Joos, A., Platzgummer, S., & Lippi, G. (2015) · Europe PMC (PubMed Central) · doi:10.2450/2015.0007-15 · Cited by 70
Serum calcium and breast cancer risk: results from a prospective cohort study of 7,847 women
Almquist, M., Manjer, J., Bondeson, L., & Bondeson, A. (2007) · Cancer Causes & Control · doi:10.1007/s10552-007-9001-0 · Cited by 69
“Both short-time [27] and long-time [28] intra-individual variation in total serum calcium are low.”
Nyman, H. T., Kristensen, A. T., Kjelgaard-Hansen, M. J., & McEvoy, F. J. (2005) · Veterinary Radiology & Ultrasound · doi:10.1111/j.1740-8261.2005.00034.x · Cited by 68
Influence of temperature and time before centrifugation of specimens for routine coagulation testing
Salvagno, G. L., Lippi, G., Montagnana, M., Franchini, M., POLI, G., & Guidi, G. C. (2008) · International Journal of Laboratory Hematology · doi:10.1111/j.1751-553x.2008.01058.x · Cited by 67
“Results were also compared with the current analytical quality specifications for desirable bias derived from biologic variation (Ricos et al., 1999).”
ResultRazavi, M., Anderson, N. L., Pope, M. E., Yip, R., & Pearson, T. W. (2016) · New Biotechnology · doi:10.1016/j.nbt.2015.12.008 · Cited by 67
“Since CVi has been empirically measured for 125 clinically important protein analytes (assembled in a very valuable database by Ricos and her colleagues [15]), it is possible to determine objectively the assay precision required to address basic clinical questions.”
BackgroundHow to assess the quality of your analytical method?
Topić, E., Nikolac, N., Panteghini, M., Theodorsson, E., Salvagno, G. L., Miler, M., Šimundić, A.-M., Infusino, I., Nordin, G., & Westgard, S. A. (2015) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm-2015-0869 · Cited by 67
Influence of the needle bore size on platelet count and routine coagulation testing
Lippi, G., Salvagno, G. L., Montagnana, M., Poli, G., & Guidi, G. C. (2006) · Blood Coagulation & Fibrinolysis · doi:10.1097/01.mbc.0000245300.10387.ca · Cited by 67
Delanghe, J., Cobbaert, C. M., Galteau, M. M., Harmoinen, A. P. T., Jansen, R., Kruse, R., Laitinen, P. H., Thienpont, L. M., Wuyts, B., Weykamp, C. W., et al. (2008) · Clinical Chemistry and Laboratory Medicine (CCLM) · doi:10.1515/cclm.2008.256 · Cited by 67
Short-term venous stasis influences routine coagulation testing
Lippi, G., Salvagno, G. L., Montagnana, M., & Guidi, G. C. (2005) · Blood Coagulation & Fibrinolysis · doi:10.1097/01.mbc.0000178828.59866.03 · Cited by 66
Application of biological variation - a review
Ricos, C., Perich, C., Minchinela, J., Alvarez, V., Simon, M., Biosca, C., Domenech, M., Fernandez, P., Jimenez, C.-V., Garcia-Lario, J. V., et al. (2009) · Biochemia Medica · doi:10.11613/bm.2009.023 · Cited by 66
History of the preanalytical phase: a personal view
Guder, W. (2014) · Biochemia Medica · doi:10.11613/bm.2014.005 · Cited by 65
“(24,25) helped to define biological variation for each analyte as a basis for defining preanalytical and total laboratory quality indicators.”
BackgroundOppliger, S., Hartnack, S., Riond, B., Reusch, C. E., & Kook, P. H. (2013) · Journal of Veterinary Internal Medicine · doi:10.1111/jvim.12150 · Cited by 65
Metadata
- Authors
- C. Ricós, V. A.
- Venue
- Scandinavian Journal of Clinical and Laboratory Investigation
- Publisher
- Informa UK Limited
- Published
- 1999-01
- Volume
- 59
- Issue
- 7
- Pages
- 491-500
- ISSN
- 0036-5513 (ISSN-L)
- 1502-7686
- OpenAlex
- W2119950421
- Cited by
- 987
- References
- 6
- Citations by year
- 2026: 17 · 2025: 25 · 2024: 22 · 2023: 29 · 2022: 41 · 2021: 44 · 2020: 47 · 2019: 51 · 2018: 64 · 2017: 69 · 2016: 58 · 2015: 46 · 2014: 76 · 2013: 56 · 2012: 55
- FWCI
- 5.10
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Scandinavian Journal of Clinical and Laboratory Investigation (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Health Professions › Medical Laboratory Technology › Clinical Laboratory Practices and Quality Control
- Physical Sciences › Physics and Astronomy › Instrumentation › Scientific Measurement and Uncertainty Evaluation
- Social Sciences › Decision Sciences › Statistics, Probability and Uncertainty › Reliability and Agreement in Measurement
- Keywords
- biological variation, reference values, clinical laboratory testing, within-subject coefficient of variation, total error, bias and precision, disease states, hormones
- MeSH terms
- Humans, Quality Control, Clinical Laboratory Techniques, Databases as Topic
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.