Current Status of Methods and Techniques for Breath Analysis
The DOI matches its Crossref record; 76 of the 76 references it cites were found in a registry or an index.
Abstract
Due to the great potentials in clinical diagnosis, disease state monitoring, and environmental exposure assessment, the breath test is becoming one of the most desirable noninvasive procedures for clinical diagnostics. This article reviews the technical aspects of breath analysis including sample collection, analyte preconcentration, vapor desorption, and various measurement techniques, as well as some recent developments in the field. Because the exhaled breath is affected by the composition of ambient air, the elimination of background influence on the analyte detection is also discussed. Both advantages and major obstacles of breath analysis techniques in clinical practice are presented and summarized.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Journal of Laboratory and Clinical Medicine
(2003) · Journal of Laboratory and Clinical Medicine · doi:10.1016/s0022-2143(03)00127-6 · Cited by 1,767
Lindinger, W., Hansel, A., & Jordan, A. (1998) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/s0168-1176(97)00281-4 · Cited by 1,615
“The Medical Journal of Australia”
(1923) · Medical Journal of Australia · doi:10.5694/j.1326-5377.1923.tb64467.x · Cited by 1,439
Exhaled breath condensate: methodological recommendations and unresolved questions
Horváth, I., Hunt, J., & Barnes, P. J. (2005) · European Respiratory Journal · doi:10.1183/09031936.05.00029705 · Cited by 1,284
Diagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
Quantitative Analysis of Urine Vapor and Breath by Gas-Liquid Partition Chromatography
Pauling, L., Robinson, A. B., Teranishi, R., & Cary, P. (1971) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.68.10.2374 · Cited by 1,025 · cited 1×
“determined more than 200 components in human breath using gas chromatography ( 1 , 8 ).”
MethodMeasurement of continuous distributions of ventilation-perfusion ratios: theory
Wagner, P. D., Saltzman, H. A., & West, J. B. (1974) · Journal of Applied Physiology · doi:10.1152/jappl.1974.36.5.588 · Cited by 830
Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis
Smith, D., & Španěl, P. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20033 · Cited by 801
Variation in volatile organic compounds in the breath of normal humans
Phillips, M., Herrera, J., Krishnan, S., Zain, M., Greenberg, J., & Cataneo, R. N. (1999) · Journal of Chromatography B: Biomedical Sciences and Applications · doi:10.1016/s0378-4347(99)00127-9 · Cited by 738
Proton transfer reaction mass spectrometry: on-line trace gas analysis at the ppb level
Hansel, A., Jordan, A., Holzinger, R., Prazeller, P., Vogel, W., & Lindinger, W. (1995) · International Journal of Mass Spectrometry and Ion Processes · doi:10.1016/0168-1176(95)04294-u · Cited by 727
Cited by
Electronic Nose: Current Status and Future Trends
Röck, F., Barsan, N., & Weimar, U. (2008) · Chemical Reviews · doi:10.1021/cr068121q · Cited by 1,437
Diagnosing lung cancer in exhaled breath using gold nanoparticles
Peng, G., Tisch, U., Adams, O., Hakim, M., Shehada, N., Broza, Y. Y., Billan, S., Abdah-Bortnyak, R., Kuten, A., & Haick, H. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.235 · Cited by 1,263
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Volatile Organic Compounds of Lung Cancer and Possible Biochemical Pathways
Hakim, M., Broza, Y. Y., Barash, O., Peled, N., Phillips, M., Amann, A., & Haick, H. (2012) · Chemical Reviews · doi:10.1021/cr300174a · Cited by 953
Carbon Nanotube Gas and Vapor Sensors
Kauffman, D. R., & Star, A. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200704488 · Cited by 828
Assessment, origin, and implementation of breath volatile cancer markers
Haick, H., Broza, Y. Y., Mochalski, P., Ruzsanyi, V., & Amann, A. (2014) · Chem. Soc. Rev. · doi:10.1039/c3cs60329f · Cited by 644
Righettoni, M., Tricoli, A., & Pratsinis, S. E. (2010) · Analytical Chemistry · doi:10.1021/ac902695n · Cited by 630
Wang, C., & Sahay, P. (2009) · Sensors · doi:10.3390/s91008230 · Cited by 596
Semiconductor Gas Sensors: Dry Synthesis and Application
Tricoli, A., Righettoni, M., & Teleki, A. (2010) · Angewandte Chemie International Edition · doi:10.1002/anie.200903801 · Cited by 543
Advances in Electronic-Nose Technologies Developed for Biomedical Applications
Wilson, A. D., & Baietto, M. (2011) · Sensors · doi:10.3390/s110101105 · Cited by 400
Solid-state gas sensors for breath analysis: A review
Di Natale, C., Paolesse, R., Martinelli, E., & Capuano, R. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.03.014 · Cited by 365
A review of breath analysis for diagnosis of human health
Kim, K.-H., Jahan, S. A., & Kabir, E. (2012) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2011.09.013 · Cited by 345
Progress in SIFT‐MS: Breath analysis and other applications
Španěl, P., & Smith, D. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20303 · Cited by 336
Clinical Application of Volatile Organic Compound Analysis for Detecting Infectious Diseases
Sethi, S., Nanda, R., & Chakraborty, T. (2013) · Clinical Microbiology Reviews · doi:10.1128/cmr.00020-13 · Cited by 331
Breath Analysis as a Potential and Non-Invasive Frontier in Disease Diagnosis: An Overview
Pereira, J., Porto-Figueira, P., Cavaco, C., Taunk, K., Rapole, S., Dhakne, R., Nagarajaram, H., & Câmara, J. (2015) · Metabolites · doi:10.3390/metabo5010003 · Cited by 301
Mid-infrared Fourier transform spectroscopy with a broadband frequency comb
Adler, F., Masłowski, P., Foltynowicz, A., Cossel, K. C., Briles, T. C., Hartl, I., & Ye, J. (2010) · Optics Express · doi:10.1364/oe.18.021861 · Cited by 274
Güntner, A. T., Koren, V., Chikkadi, K., Righettoni, M., & Pratsinis, S. E. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00008 · Cited by 257
Cavity-Enhanced Direct Frequency Comb Spectroscopy: Technology and Applications
Adler, F., Thorpe, M. J., Cossel, K. C., & Ye, J. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-060908-155248 · Cited by 236
Hierarchical nanostructured WO3–SnO2for selective sensing of volatile organic compounds
Nayak, A. K., Ghosh, R., Santra, S., Guha, P. K., & Pradhan, D. (2015) · Nanoscale · doi:10.1039/c5nr02571k · Cited by 220
Quantum cascade lasers (QCLs) in biomedical spectroscopy
Schwaighofer, A., Brandstetter, M., & Lendl, B. (2017) · Chemical Society Reviews · doi:10.1039/c7cs00403f · Cited by 199
Leong, S. X., Leong, Y. X., Tan, E. X., Sim, H. Y. F., Koh, C. S. L., Lee, Y. H., Chong, C., Ng, L. S., Chen, J. R. T., Pang, D. W. C., et al. (2022) · ACS Nano · doi:10.1021/acsnano.1c09371 · Cited by 199
Nanoscale Sensor Technologies for Disease Detection via Volatolomics
Vishinkin, R., & Haick, H. (2015) · Small · doi:10.1002/smll.201501904 · Cited by 199
Sniffing the Unique “Odor Print” of Non‐Small‐Cell Lung Cancer with Gold Nanoparticles
Barash, O., Peled, N., Hirsch, F. R., & Haick, H. (2009) · Small · doi:10.1002/smll.200900937 · Cited by 183
Xiao, T., Wang, X.-Y., Zhao, Z.-H., Li, L., Zhang, L., Yao, H.-C., Wang, J.-S., & Li, Z.-J. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.04.015 · Cited by 181
A Novel Breath Analysis System Based on Electronic Olfaction
Guo, D., Zhang, D., Li, N., Zhang, L., & Yang, J. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2055864 · Cited by 178
“and on the breath-test tracks, dead-space air may be either a necessity or a contaminant [12].”
BackgroundTripathi, K. M., Kim, T., Losic, D., & Tung, T. T. (2016) · Carbon · doi:10.1016/j.carbon.2016.08.040 · Cited by 171
Metadata
- Authors
- Cao, W., & Duan, Y.
- Venue
- Critical Reviews in Analytical Chemistry
- Publisher
- Informa UK Limited
- Published
- 2007-03-02
- Volume
- 37
- Issue
- 1
- Pages
- 3-13
- ISSN
- 1040-8347 (ISSN-L)
- 1547-6510
- OpenAlex
- W2005339690
- Cited by
- 191
- References
- 76
- FWCI
- 7.77
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.