Electrosprayed naringin-loaded microsphere/SAIB hybrid depots enhance bone formation in a mouse calvarial defect model
The DOI matches its Crossref record; 37 of the 37 references it cites were found in a registry or an index.
Abstract
The burst release of active osteogenic factors, which is not beneficial to osteogenesis, is commonly encountered in bone tissue engineering. The aims of this study were to prepare naringin-loaded microsphere/sucrose acetate isobutyrate (Ng-m-SAIB) hybrid depots, reduce the burst release of naringin (Ng), and improve osteogenesis. The morphology and size distributions of electrosprayed Ng-microspheres were characterized by scanning electron microscopy (SEM). The Ng-microspheres and Ng-m-SAIB depots were characterized by Fourier transform infrared spectroscopy (FTIR) and in vitro release studies. In vitro osteoblast-microsphere interactions and in vivo osteogenesis were assessed after implantation of Ng-m-SAIB depots. The addition of sucrose acetate isobutyrate (SAIB) to monodisperse Ng-microspheres did not cause a change in the chemical structure. The performances of the microspheres in osteoblast-microsphere interactions were better when the naringin content was 4% than when it was at 2% and 6%. On the first day following the loading of Ng-microspheres (2%, 4%, and 6%) into SAIB depots, the burst release was reduced dramatically from 70.9% to 6.3%, 73.1% to 7.2%, and 73.9% to 9.9%, respectively. In addition, after 8 weeks, the new bone formation rate in the calvarial defects of SD rats receiving Ng-m-SAIB was 53.1% compared to 21.2% for the control group and 16.1% for the microsphere-SAIB group. These results demonstrated that Ng-m-SAIB hybrid depots may have promise in bone regeneration applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“the viscosity of the SAIB can be dramatically reduced when mixing with a little amount of solvent, for example, ethanol, allowing the SAIB to be easily inject using small needles”
From Electrosprayed minocycline hydrochloride-loaded microsphere/SAIB hybrid depot for periodontitis treatment (2021) · cites this paper as Yang et al., 2019
In the citing paper
“Xia Lin’s study and our previous study showed that the combination of microsphere and SAIB could significantly decrease burst release of the investigated drugs”
From Electrosprayed minocycline hydrochloride-loaded microsphere/SAIB hybrid depot for periodontitis treatment (2021) · cites this paper as Yang et al., 2019
In the citing paper
“Upon injection, the solvent diffuses from the depot into body fluid, resulting in a highly viscous SAIB depot from where the drug can be released in a sustained manner”
From Electrosprayed minocycline hydrochloride-loaded microsphere/SAIB hybrid depot for periodontitis treatment (2021) · cites this paper as Yang et al., 2019
In the citing paper
“With increase in the theoretical drug loading, the actual drug loading of the electrosprayed microspheres increased, which achieved an agreement with previous studies (Yang et al., 2019).”
From Electrosprayed minocycline hydrochloride-loaded microsphere/SAIB hybrid depot for periodontitis treatment (2021) · cites this paper as Yang et al., 2019
In the citing paper
“after the MINO-microspheres were loaded into SAIB, the burst release of MINO significantly decreased, which was in agreement with the findings of several studies (Lee et al., 2006; Wang et al., 2016; Yang et al., 2019).”
From Electrosprayed minocycline hydrochloride-loaded microsphere/SAIB hybrid depot for periodontitis treatment (2021) · cites this paper as Yang et al., 2019
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Komori, T., Yagi, H., Nomura, S., Yamaguchi, A., Sasaki, K., Deguchi, K., Shimizu, Y., Bronson, R. T., Gao, Y.-H., Inada, M., et al. (1997) · Cell · doi:10.1016/s0092-8674(00)80258-5 · Cited by 4,244
On the importance and mechanisms of burst release in matrix-controlled drug delivery systems
Huang, X., & Brazel, C. S. (2001) · Journal of Controlled Release · doi:10.1016/s0168-3659(01)00248-6 · Cited by 1,813
Complexity in biomaterials for tissue engineering
Place, E. S., Evans, N. D., & Stevens, M. M. (2009) · Nature Materials · doi:10.1038/nmat2441 · Cited by 1,728
Electrospraying of polymers with therapeutic molecules: State of the art
Bock, N., Dargaville, T. R., & Woodruff, M. A. (2012) · Progress in Polymer Science · doi:10.1016/j.progpolymsci.2012.03.002 · Cited by 440
Therapeutic potential of naringin: an overview
Chen, R., Qi, Q.-L., Wang, M.-T., & Li, Q.-Y. (2016) · Pharmaceutical Biology · doi:10.1080/13880209.2016.1216131 · Cited by 401
Mu, L., & Feng, S. S. (2002) · Journal of Controlled Release · doi:10.1016/s0168-3659(02)00025-1 · Cited by 328
Bock, N., Woodruff, M. A., Hutmacher, D. W., & Dargaville, T. R. (2011) · Polymers · doi:10.3390/polym3010131 · Cited by 326
Ramazani, F., Chen, W., van Nostrum, C. F., Storm, G., Kiessling, F., Lammers, T., Hennink, W. E., & Kok, R. J. (2016) · International Journal of Pharmaceutics · doi:10.1016/j.ijpharm.2016.01.020 · Cited by 288
Lee, S. S., Huang, B. J., Kaltz, S. R., Sur, S., Newcomb, C. J., Stock, S. R., Shah, R. N., & Stupp, S. I. (2013) · Biomaterials · doi:10.1016/j.biomaterials.2012.10.005 · Cited by 267
Liu, X., Zhao, K., Gong, T., Song, J., Bao, C., Luo, E., Weng, J., & Zhou, S. (2014) · Biomacromolecules · doi:10.1021/bm401911p · Cited by 178
Research works printed but not linked: 2
- Ma X, 2016, Sci Rep, 6, 245
- Wang H, 2017, Iran J Basic Med Sci, 20, 408
Cited by
Bioactive Materials for Bone Regeneration: Biomolecules and Delivery Systems
Szwed-Georgiou, A., Płociński, P., Kupikowska-Stobba, B., Urbaniak, M. M., Rusek-Wala, P., Szustakiewicz, K., Piszko, P., Krupa, A., Biernat, M., Gazińska, M., et al. (2023) · ACS Biomaterials Science & Engineering · doi:10.1021/acsbiomaterials.3c00609 · Cited by 269
Zhang, T., Qiu, Y., Song, J., Zhou, P., Liao, H., Cheng, Y., & Wu, X. (2021) · Drug Delivery · doi:10.1080/10717544.2021.1902020 · Cited by 36
Self-citationBisphosphonate-incorporated coatings for orthopedic implants functionalization
Zhang, J., Bai, H., Bai, M., Wang, X., Li, Z., Xue, H., Wang, J., Cui, Y., Wang, H., Wang, Y., et al. (2023) · Materials Today Bio · doi:10.1016/j.mtbio.2023.100737 · Cited by 22
“Thus, ideal BPs coatings need to possess good osteogenesis, osteoinductivity, and osteoconductivity [133,134].”
BackgroundArriaga, M. A., Amieva, J. A., Quintanilla, J., Jimenez, A., Ledezma, J., Lopez, S., Martirosyan, K. S., & Chew, S. A. (2023) · Biotechnology and Bioengineering · doi:10.1002/bit.28527 · Cited by 2
Metadata
- Authors
- Yang, X., Almassri, H. N. S., Zhang, Q., Ma, Y., Zhang, D., Chen, M., & Wu, X.
- Affiliations
- Department of Prosthodontics, Stomatological Hospital of Chongqing Medical University, Chongqing, China;
- Venue
- Drug Delivery
- Publisher
- Informa UK Limited
- Published
- 2019-01-01
- Volume
- 26
- Issue
- 1
- Pages
- 137-146
- ISSN
- 1071-7544
- 1521-0464
- Cited by
- 29
- References
- 37
- Language
- en
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.