Performance of N95 Respirators: Filtration Efficiency for Airborne Microbial and Inert Particles
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
In 1995 the National Institute for Occupational Safety and Health issued new regulations for nonpowered particulate respirators (42 CFR Part 84). A new filter certification system also was created. Among the new particulate respirators that have entered the market, the N95 respirator is the most commonly used in industrial and health care environments. The filtration efficiencies of unloaded N95 particulate respirators have been compared with those of dust/mist (DM) and dust/fume/mist (DFM) respirators certified under the former regulations (30 CFR Part 11). Through laboratory tests with NaCl certification aerosols and measurements with particle-size spectrometers, N95 respirators were found to have higher filtration efficiencies than DM and DFM respirators and noncertified surgical masks. N95 respirators made by different companies were found to have different filtration efficiencies for the most penetrating particle size (0.1 to 0.3 micron), but all were at least 95% efficient at that size for NaCl particles. Above the most penetrating particle size the filtration efficiency increases with size; it reaches approximately 99.5% or higher at about 0.75 micron. Tests with bacteria of size and shape similar to Mycobacterium tuberculosis also showed filtration efficiencies of 99.5% or higher. Experimental data were used to calculate the aerosol mass concentrations inside the respirator when worn in representative work environments. The penetrated mass fractions, in the absence of face leakage, ranged from 0.02% for large particle distributions to 1.8% for submicrometer-size welding fumes. Thus, N95 respirators provide excellent protection against airborne particles when there is a good face seal.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Inward leakage due to gaps in the fit has been demonstrated to play a critical role in the ability of a mask or respirator to protect against exposure to particulates [4, 59, 82–84].”
From The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage (2021) · cites this paper as [83]
In the citing paper
“They have at least 95% filtration efficiency for NaCl particles sized 0.1 to 0.3 𝜇 m with even higher filtration efficiency at higher particle size (approximately 99.5% or higher for 0.75 𝜇 m particles). 5”
From Assessment of N95 and K95 respirator decontamination: fiber integrity, filtration efficiency, and dipole charge density (2020) · cites this paper as [5]
In the citing paper
“with an average aerodynamic diameter reported to range from approximately 0.8-1.1 µm.(14,16,17)”
From Performance of Conventional and Antimicrobial-Treated Filtering Facepiece Respirators Challenged with Biological Aerosols (2012) · cites this paper as [16]
In the citing paper
“Moreover, previous studies have shown agreement between physical penetrations of inert and biological aerosols at particle sizes of 1 µm and above.(13,16,24,31,32)”
From Performance of Conventional and Antimicrobial-Treated Filtering Facepiece Respirators Challenged with Biological Aerosols (2012) · cites this paper as [16]
In the citing paper
“wearing surgical or FFP2 masks substantially reduces the number of bioaerosol particles emitted from human respiration.”
From Bacteria Filtration Efficiency for Different Types of Protective Face Masks (2023) · cites this paper as [26]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Aerosol penetration and leakae characteristics of masks used in the health care industry
Weber, A. M., Willeke, K., Marchloni, R., Myojo, T., McKay, R. T., Donnelly, J., & Liebhaber, F. B. (1993) · American Journal of Infection Control · doi:10.1016/0196-6553(93)90027-2 · Cited by 156
Self-citationChen, S.-K., Vesley, D., Brosseau, L. M., & Vincent, J. H. (1994) · American Journal of Infection Control · doi:10.1016/0196-6553(94)90116-3 · Cited by 124
Penetration of Airborne Microorganisms Through a Surgical Mask and a Dust/Mist Respirator
Willeke, K., Qian, Y., Donnelly, J., Grinshpun, S., & Ulevicius, V. (1996) · American Industrial Hygiene Association Journal · doi:10.1080/15428119691014882 · Cited by 84
Self-citationCalibration and performance of an API Aerosizer
Cheng, Y., Barr, E. B., Marshall, I. A., & Mitchell, J. P. (1993) · Journal of Aerosol Science · doi:10.1016/0021-8502(93)90034-7 · Cited by 58
Efficacy of Selected Respiratory Protective Equipment Challenged with Bacillus subtilis subsp. niger
Johnson, B., Martin, D. D., & Resnick, I. G. (1994) · Applied and Environmental Microbiology · doi:10.1128/aem.60.6.2184-2186.1994 · Cited by 44
STEVENS, G. A., & MOYER, E. S. (1989) · American Industrial Hygiene Association Journal · doi:10.1080/15298668991374615 · Cited by 39
AEROSOL PENETRATION THROUGH FILTERING FACEPIECES AND RESPIRATOR CARTRIDGES
Chen, C. C., Lehtimäki, M., & Willeke, K. (1992) · American Industrial Hygiene Association Journal · doi:10.1080/15298669291360166 · Cited by 37
Self-citationRESPIRATOR PERFORMANCE RATING TABLE FOR MASK DESIGN
Johnson, A. T., Weiss, R. A., & Grove, C. M. (1992) · American Industrial Hygiene Association Journal · doi:10.1080/15298669291359500 · Cited by 37
Dynamic size spectrometry of airborne microorganisms: Laboratory evaluation and calibration
Qian, Y., Willeke, K., Ulevičius, V., Grinshpun, S. A., & Donnelly, J. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(95)00043-x · Cited by 37
Self-citationHan, D.-H., Willeke, K., & Colton, C. E. (1997) · American Industrial Hygiene Association Journal · doi:10.1080/15428119791012874 · Cited by 29
Self-citation
Cited by
Items 101–200 of 326
Effects of N95 Mask Use on Pulmonary Function in Children
Lubrano, R., Bloise, S., Marcellino, A., Ciolli, C. P., Testa, A., Luca, E. D., Dilillo, A., Mallardo, S., Isoldi, S., Martucci, V., et al. (2021) · The Journal of Pediatrics · doi:10.1016/j.jpeds.2021.05.050 · Cited by 29
Toward nanotechnology-enabled face masks against SARS-CoV-2 and pandemic respiratory diseases
El‐Atab, N., Mishra, R., & Hussain, M. M. (2021) · Nanotechnology · doi:10.1088/1361-6528/ac3578 · Cited by 29
Transmission of communicable respiratory infections and facemasks
Guo, Y. (2008) · Journal of Multidisciplinary Healthcare · doi:10.2147/jmdh.s3019 · Cited by 29
Adapting to the Coronavirus Disease 2019 Pandemic in New York City
Escalon, M. X., & Herrera, J. E. (2020) · American Journal of Physical Medicine & Rehabilitation · doi:10.1097/phm.0000000000001451 · Cited by 28
Managing Burns During COVID-19 Outbreak
Saha, S., Kumar, A., Dash, S., & Singhal, M. (2020) · Journal of Burn Care & Research · doi:10.1093/jbcr/iraa086 · Cited by 28
Deventer, D. V., Marecaux, J., Doubleday, A., Errett, N. A., & Isaksen, T. B. (2020) · Journal of Public Health Management and Practice · doi:10.1097/phh.0000000000001151 · Cited by 28
The human factors/ergonomics studies for respirators: a review and future work
Chen, Y., Wang, J., & Yang, Z. (2015) · International Journal of Clothing Science and Technology · doi:10.1108/ijcst-06-2014-0077 · Cited by 27
Zheng, C. R., Li, S., Ye, C., Li, X., Zhang, C., & Yu, X. (2016) · Environmental Science & Technology · doi:10.1021/acs.est.6b00788 · Cited by 27
TU Delft COVID-app: A tool to democratize CFD simulations for SARS-CoV-2 infection risk analysis
Faleiros, D. E., van den Bos, W., Botto, L., & Scarano, F. (2022) · The Science of The Total Environment · doi:10.1016/j.scitotenv.2022.154143 · Cited by 26
“Many studies only considered droplet penetration through the mask (Qian et al., 1998; Lee et al., 2005; Ardon-Dryer et al., 2021), neglecting droplets escaping through leakages between the mask and the subject's face.”
Kisielinski, K., Hockertz, S., Hirsch, O., Korupp, S., Klosterhalfen, B., Schnepf, A., & Dyker, G. (2024) · Ecotoxicology and Environmental Safety · doi:10.1016/j.ecoenv.2023.115858 · Cited by 26
“…or contamination (Gralton and McLaws, 2010; Kisielinski et al., 2021; Kisielinski et al., 2023a; Lee et al., 2008; Liu et al., 2023; Loeb et al., 2009; Ntlailane and Wichmann, 2019; Qian et al., 1998; Rengasamy et al., 2009; Samaranayake et al., 2020; Smith et al., 2016; Willeke et al., 1996).”
Institute of Medicine (2009) · National Academies Press eBooks · doi:10.17226/12748 · Cited by 26
“respirators have found consistently high filtering capacity of N95 respirators and a wide range of filtering performance by medical masks (Qian et al., 1998; Oberg and Brosseau, 2008; Rengasamy et al., 2008, 2009).”
BackgroundSteinberg, B. E., Aoyama, K., McVey, M. J., Levin, D. N., Siddiqui, A. A., Munshey, F., Goldenberg, N. M., Faraoni, D., & Maynes, J. T. (2020) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-020-01770-w · Cited by 25
Application of Nanomaterials in Personal Respiratory Protection Equipment: A Literature Review
Abbasinia, M., Karimie, S., Haghighat, M., & Mohammadfam, I. (2018) · Safety · doi:10.3390/safety4040047 · Cited by 25
Gomersall, C. D., Loo, S., Joynt, G. M., & Taylor, B. L. (2007) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e3282f1bafd · Cited by 25
Rüping, M. J. G. T., Vehreschild, J. J., Groll, A. H., Lass‐Flörl, C., Ostermann, H., Ruhnke, M., & Cornely, O. A. (2011) · Mycoses · doi:10.1111/j.1439-0507.2010.01989.x · Cited by 24
A model of tuberculosis transmission and intervention strategies in an urban residential area
Pienaar, E., Fluitt, A. M., Whitney, S. E., Freifeld, A. G., & Viljoen, H. J. (2010) · Computational Biology and Chemistry · doi:10.1016/j.compbiolchem.2010.03.003 · Cited by 24
“Nicas (1995) found surgical masks provide a 50% reduction in cumulative risk of infection, while N95 respirators are predicted to filter 99% of bacteria of similar shape and size to Mycobacterium tuberculosis (Qian et al., 1998).”
Nanoparticle Filtration Performance of Commercially Available Dust Masks
Rengasamy, S., Eimer, B. C., & Shaffer, R. E. (2008) · Journal of the International Society for Respiratory Protection · doi:10.66828/001c.167215 · Cited by 24
“The filtration performance of NIOSH-approved respirators is well documented by various laboratories (Qian et al., 1998; Willeke and Qian, 1998; Richardson et al., 2006).”
Filtration of respired gases: theoretical aspects.
Thiessen, R. J. (2006) · PubMed · doi:10.1016/j.rcc.2006.03.001 · Cited by 24
Mareković, I. (2023) · Journal of Fungi · doi:10.3390/jof9020151 · Cited by 23
“Surgical masks are routinely used by high risk patients in many institutions, but their benefit for these patients has never been shown clinically [85].”
BackgroundDavidson, C. S., Green, C. F., Gibbs, S. G., Schmid, K. K., Panlilio, A. L., Jensen, P. A., & Scarpino, P. V. (2013) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.818243 · Cited by 23
Sobti, A. S., Fathi, M., Mokhtar, M. A., Mahana, K., Rashid, M. S., Polyzois, I., Narvani, A. A., & Imam, M. A. (2020) · The Surgeon · doi:10.1016/j.surge.2020.08.001 · Cited by 21
“N95 respirators, powered air purifying respirators (PAPR), or standard surgical masks have been proposed for surgical procedures on patients with COVID-19.”
InfluentialMahdavi, A. (2013) · Spectrum Research Repository (Concordia University) · Cited by 22
Liquid repellency enabled antipathogen coatings
Li, W., Wang, Y., Tang, X. G., Yuen, T. T., Han, X., Li, J., Huang, N., Chan, J. F., Chu, H., & Wang, L. (2021) · Materials Today Bio · doi:10.1016/j.mtbio.2021.100145 · Cited by 20
“Personal protective equipment such as surgical masks block the airborne route of transmission through fi ltration wherein a micro-/ nano fi ber matrix traps pathogens using inertial and electrostatic forces [20].”
Dry heat sterilization as a method to recycle N95 respirator masks: The importance of fit
Yuen, J. G., Marschilok, A. C., Benziger, P. T., Yan, S., Cello, J., Stackhouse, C. A., Kisslinger, K., Bock, D. C., Takeuchi, E. S., Takeuchi, K. J., et al. (2022) · PLoS ONE · doi:10.1371/journal.pone.0257963 · Cited by 19
Gao, S., Kim, J. Y., Yermakov, M. V., Elmashae, Y., He, X., Reponen, T. A., Zhuang, Z., Rengasamy, S., & Grinshpun, S. A. (2016) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mew019 · Cited by 20
Self-citationWhat We Are Learning from COVID-19 for Respiratory Protection: Contemporary and Emerging Issues
Li, R., Zhang, M., Wu, Y., Tang, P., Sun, G. Z., Wang, L., Mandal, S., Wang, L., Lang, J. A., Passalacqua, A., et al. (2021) · Polymers · doi:10.3390/polym13234165 · Cited by 18
“Higher airflow speeds increase the inertia of large particles that are then captured by impaction [79], whereas lower airflow increases the loading or residence time of particles which are then captured by diffusive or electrostatic mechanisms [79,86].”
BackgroundPrevention of mould infections
Maschmeyer, G. (2009) · Journal of Antimicrobial Chemotherapy · doi:10.1093/jac/dkp084 · Cited by 18
“5 mm size.(22,23) In contrast, surgical masks routinely used by high-risk patients in many institutions have been clearly shown not to prevent the penetration of these particles sufficiently,(23,24) and their benefit for these patients has never been shown clinically.”
Charney, W., Lange, J., Mastrangelo, G., Lavoie, J., Cloutier, Y., Lara, J., Marchand, G., Anderson, J., Geeslin, A. G., & Streifel, A. J. (2009) · CRC Press eBooks · doi:10.1201/9781420047868-c4 · Cited by 18
Carreras, E. (2006) · Clinical Microbiology and Infection · doi:10.1111/j.1469-0691.2006.01608.x · Cited by 18
“However, not all patients are able to correctly wear and tolerate these masks [30,31].”
BackgroundLore, M. B., Sebastian, J. M., Brown, T. L., Viner, A. S., McCullough, N. V., & Hinrichs, S. H. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2011.640273 · Cited by 17
“Moreover, previous studies have shown agreement between physical penetrations of inert and biological aerosols at particle sizes of 1 μm and above.(13,16,24,31,32)”
Sousan, S., Garcia, N. M., White, A. V., & Balanay, J. A. G. (2020) · American Journal of Infection Control · doi:10.1016/j.ajic.2020.11.005 · Cited by 17
Cezár-Vaz, M. R., Bonow, C. A., & Vaz, J. C. (2015) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph120100986 · Cited by 17
Wolhuter, K., Arora, M., & Kovacic, J. C. (2021) · BioEssays · doi:10.1002/bies.202100046 · Cited by 17
“[13] Due to the complex nature of PM, it is typically classified by the size of the particles (Figure 1A).”
BackgroundInfluentialVentilation of ordinary face masks
Huo, S., & Zhang, T. (2021) · Building and Environment · doi:10.1016/j.buildenv.2021.108261 · Cited by 17
Rule, A. M., Ramachandran, G., & Koehler, K. A. (2020) · ACS Nano · doi:10.1021/acsnano.0c05265 · Cited by 17
Su, W., Lee, J., Xi, J., & Zhang, K. (2022) · Aerosol and Air Quality Research · doi:10.4209/aaqr.210228 · Cited by 16
“The N95 mask is characterized by its tight-fitting design (face seal, nose clip, and stretchable straps) and the material of the N95 is dense with high particle filtration efficiency (Qian et al., 1998).”
BackgroundSipkens, T. A., Corbin, J. C., Koukoulas, T., Oldershaw, A., Lavoie, T., Oliaee, J. N., Liu, F., Leroux, I. D., Smallwood, G. J., Lobo, P., et al. (2022) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2022.2114596 · Cited by 16
Pakolpakçıl, A., Kılıç, A., & Draczyński, Z. (2023) · Nanomaterials · doi:10.3390/nano13243150 · Cited by 16
“A filtering respirator mask is a type of personal protective equipment used to shield its user from health-harming aerosol particles [51–53].”
BackgroundWen, Z., Yang, W., Li, N., Wang, J., Hu, L., Li, J., Yin, Z., Zhang, K., & Dong, X. (2013) · Particuology · doi:10.1016/j.partic.2012.11.009 · Cited by 16
“Attempts to evaluate the performance of respiratory protective equipment against biological particles have typically been performed using airborne bacteria and viruses (Balazy et al., 2006; Eninger et al., 2008; Qian, Willeke, Grinshpun, Donnelly, & Coffey, 1998) .”
Au, S. S. W., Gomersall, C. D., Leung, P., & Li, P. T. Y. (2010) · Journal of Hospital Infection · doi:10.1016/j.jhin.2010.01.017 · Cited by 16
“3, 4 The masks most likely to fit a population of staff will depend on the facial characteristics of that population.”
Recomendaciones para el control de la transmisión de la tuberculosis en hospitales
Huaroto, L., & Espinoza, M. (2009) · Revista Peruana de Medicina Experimental y Salud Pública · doi:10.17843/rpmesp.2009.263.1389 · Cited by 16
Evaluation of N95 Filtering Facepiece Respirators Challenged with Engineered Nanoparticles
Zhou, Y., & Cheng, Y. S. (2016) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2015.06.0399 · Cited by 16
“Laboratory evaluation of N95 respirators provided information on penetration efficiency as a function of particle size and flow rate showing different penetration curves for N95 respirators from different manufacturers with maximum penetrations below 5% using NaCl aerosol (Qian et al. , 1998).”
Tracheostomy guidelines developed at a large academic medical center during the COVID-19 pandemicPreprint
David, A. P. (2020) · doi:10.22541/au.158646511.19689044 · Cited by 16
Margarucci, L. M., Gianfranceschi, G., Spica, V. R., D’Ermo, G., Refi, C., Podico, M., Vitali, M., Romano, F., & Valeriani, F. (2021) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph18168662 · Cited by 15
Understanding The Benefits and Risks of Sustainable Nanomaterials in a Research Environment
Keshavan, S., Petri‐Fink, A., & Rothen‐Rutishauser, B. (2024) · CHIMIA International Journal for Chemistry · doi:10.2533/chimia.2024.397 · Cited by 14
Ahmed, J., Harker, A. H., & Edirisinghe, M. J. (2020) · Medical Devices & Sensors · doi:10.1002/mds3.10120 · Cited by 14
“It was shown that these masks are over 95% efficient against penetrating particle sizes between 100 to 300 nm, the efficiency against particles over 750 nm increases dramatically to over 99.5% (Qian et al., 1998).”
BackgroundInfluentialMask decontamination methods (model N95) for respiratory protection: a rapid review
Probst, L. F., Guerrero, A. T. G., Cardoso, A. I. D. Q., Grande, A. J., Croda, M. G., Venturini, J., Fonseca, M. C. D. C., Paniago, A. M. M., Barreto, J. O. M., & de Oliveira, S. M. D. V. L. (2021) · Systematic Reviews · doi:10.1186/s13643-021-01742-1 · Cited by 14
Wen, Z., Lu, J., Li, J., Li, N., Zhao, J., Wang, J., Yu, L., & Yang, W. (2010) · Aerobiologia · doi:10.1007/s10453-010-9160-4 · Cited by 14
“Studies on respiratory protection against TB were carried out with nonpathogenic bacteria having physical characteristics similar to those of M. tuberculosis (Chen et al. 1994; Qian et al. 1998; Brosseau et al. 1997).”
The bacterial burden of worn face masks—observational research and literature review
Kisielinski, K., Wojtasik, B., Zalewska, A., Livermore, D. M., & Jurczak-Kurek, A. (2024) · Frontiers in Public Health · doi:10.3389/fpubh.2024.1460981 · Cited by 14
COVID-19: considerations for optimum surgical team protection before, during and after operation
Punia, G., Kharb, S., Gulia, A., Bansal, S., Chandan, S., & Kumar, M. (2020) · International Journal of Research in Orthopaedics · doi:10.18203/issn.2455-4510.intjresorthop20202702 · Cited by 13
“PAPRs are generally used when HCWs cannot achieve a proper fit with an N95; guidelines and mask specifications suggest equivalence for aerosolized agents.(14) A surgical mask is capable of blocking gross inhalation of droplets, while a well-fitted N95 respirator is additionally capable of filtering aerosols.”
BackgroundNtlailane, L., & Wichmann, J. (2019) · Journal of Nanoparticle Research · doi:10.1007/s11051-019-4596-0 · Cited by 15
Barbato, L., Bernardelli, F., Braga, G., Clementini, M., Gioia, C. D., Littarru, C., Oreglia, F., Raspini, M., Brambilla, E., Iavicoli, I., et al. (2020) · Oral Diseases · doi:10.1111/odi.13646 · Cited by 13
“The rationale to use a filtering facepiece respirators (such as N95, KN95, and FFP2), rather than a surgical mask, is also due to the higher capability in protection against the small aerosol particles (<1 μm) (Bałazy et al., 2006; Qian et al., 1998) produced during dental AGPs.”
BackgroundAerosol generation during routine rhinologic surgeries and in‐office procedures
Sharma, D., Campiti, V. J., Ye, M. J., Rubel, K. E., Higgins, T. S., Wu, A. W., Shipchandler, T. Z., Burgin, S. J. M., Sim, M. W., Illing, E. A., et al. (2021) · Laryngoscope Investigative Otolaryngology · doi:10.1002/lio2.520 · Cited by 13
“presence of these small particles is of particular concern because they are more likely to penetrate an N95 mask.(12) A recent study also investigating aerosol exposure in the operat-”
BackgroundComparison of the Filtration Efficiency of Different Face Masks Against Aerosols
Stahl, C., Frederick, K. M., Chaudhary, S., Morton, C. J., Loy, D. A., Muralidharan, K., Sorooshian, A., & Parthasarathy, S. (2021) · Frontiers in Medicine · doi:10.3389/fmed.2021.654317 · Cited by 13
“Interestingly, such a particle size corresponds to the 300 nm particulate size threshold used for grading the filtration efficiency of masks (5) and the most penetrating particle size of single-filter masks (6).”
BackgroundBergeron, V., Chalfine, A., Misset, B., Moulés, V., Laudinet, N., Carlet, J. M., & Lina, B. (2010) · American Journal of Infection Control · doi:10.1016/j.ajic.2010.06.013 · Cited by 13
“3 mm).(18-20) The foregoing factors led us to consider supplemental, rapid, and cost-effectivemeasures that can be taken to lower the risk of infection from infectious patients via the airborne route.”
BackgroundZhu, J., Jiang, Q., He, X., Li, X., Wang, L., Zheng, L., Jing, P., & Chen, M. (2022) · Journal of Hospital Infection · doi:10.1016/j.jhin.2022.06.016 · Cited by 12
Grinshpun, S. A. (2010) · Wiley eBooks · doi:10.1002/9783527630134.ch13 · Cited by 12
Self-citationNanoparticle Penetration Through NIOSH-approved N95 Filtering-facepiece Respirators
Rengasamy, S., Verbofsky, R., King, W. P., & Shaffer, R. E. (2007) · Journal of the International Society for Respiratory Protection · doi:10.66828/001c.167235 · Cited by 12
Srinivasan, S., & Peh, W. (2020) · Malaysian Orthopaedic Journal · doi:10.5704/moj.2007.002 · Cited by 11
Size-Dependent Filtration Efficiency of Alternative Facemask Filter Materials
Dhanraj, D., Choudhary, S., Jammalamadaka, U. M., Ballard, D. H., Kumfer, B. M., Dang, A. J., Williams, B. J., Meacham, K., Axelbaum, R. L., & Biswas, P. (2021) · Materials · doi:10.3390/ma14081868 · Cited by 11
“N-95 filtering facepiece respirators (FFR) are highly recommended for the respiratory protection against airborne and viral particles for health care workers [24,25] but are limited for use by the public due to supply constraints.”
BackgroundEvaluation of a New Bioactive Nonwoven Fabric for Respiratory Protection
Majchrzycka, K. (2014) · Fibres and Textiles in Eastern Europe · Cited by 11
Branch‐Elliman, W., Price, C. S., Bessesen, M. T., & Perl, T. M. (2015) · Current Environmental Health Reports · doi:10.1007/s40572-015-0059-7 · Cited by 11
“5%, provided there is a good facial fit.(46) Medical masks, which are not designed for particle filtration, have lower efficiency.”
BackgroundQualitative analysis of surgical smoke produced during burn operations
Markowska, M., Krajewski, A., Maciejewska, D., Jeleń, H. H., Kaczmarek, M., & Stachowska, E. (2020) · Burns · doi:10.1016/j.burns.2020.02.014 · Cited by 10
Adepu, S., Siju, C. R., Kaki, S., Bagannagari, S., Khandelwal, M., & Bharti, V. K. (2024) · International Journal of Biological Macromolecules · doi:10.1016/j.ijbiomac.2024.137627 · Cited by 11
Four-type of Masks and its Effectiveness Based on Reduced Level of Expiratory Carbon-monoxide
Soeroso, N. N., Intan, T., Ichwan, M., Fadlurrahman, M. H., & Ananda, F. R. (2020) · Medical Archives · doi:10.5455/medarh.2020.74.342-345 · Cited by 10
“Anthracis (30), and various size of particulate (13, 14, 16, 17, 26).”
Aerosol and droplet generation from mandible and midface fixation: Surgical risk in the pandemic era
Ye, M. J., Sharma, D., Campiti, V. J., Rubel, K. E., Burgin, S. J. M., Illing, E. A., Ting, J. Y., Park, J. H., Johnson, J. M., Vernon, D. J., et al. (2020) · American Journal of Otolaryngology · doi:10.1016/j.amjoto.2020.102829 · Cited by 10
“Production of sub-micron particles is of particular concern as these have been demonstrated to have a greater propensity to penetrate N95 respirators [31].”
BackgroundGaston, C. J., Royer, H. M., Leibensperger, R. J., Maizel, D., Lanpher, K. B., Solo‐Gabriele, H. M., Brand, L. E., Zhai, R. G., Caban-Martinez, A. J., & Popendorf, K. J. (2021) · Aerosol and Air Quality Research · doi:10.4209/aaqr.210016 · Cited by 10
“…standards and measure either particle number counts or mass concentrations upstream and downstream of filter material (Willeke et al. , 1996; Qian et al. , 1998; Huang et al. , 2007; Jung et al. , 2014; Zíková et al. , 2015; Serfozo et al. , 2017; Drewnick et al. , 2020; Konda et al. ,…”
Chaaban, O., Balanay, J. A. G., & Sousan, S. (2022) · American Journal of Infection Control · doi:10.1016/j.ajic.2022.06.024 · Cited by 10
Investigation of the Filtration Properties of Medical Masks
Akalın, M., Usta, İ., Koçak, D., & Ozen, M. S. (2010) · Elsevier eBooks · doi:10.1533/9780857090348.93 · Cited by 10
Filtration of Bioaerosols Using Fibrous Air Filter Media
Liu, J., Qi, R., Quan-peng, L., Han, G., & Qi, J. (2009) · Science and Technology for the Built Environment · doi:10.1080/10789669.2009.10390884 · Cited by 10
“The results in all cases showed the filtration efficiencies are 99.5% or higher (Qian et al. 1998).”
BackgroundInfluentialEstudios de la tuberculosis desde la Sucursal del Cielo
Díaz, G., Ramírez, L. M. N., David Augusto López, R., Diana Andrea Castillo, J., Pacheco, R., Rosita Nohemy Dorado, C., Miranda, L. D. C. L., Moreno, P. K. G., Ramos, B. E. F., Pedraza, M. G., et al. (2021) · Universidad Icesi; Universidad Santiago de Cali; eBooks · doi:10.18046/eui/ee.1.2021 · Cited by 9
Spicciarelli, V., Marruganti, C., Viviano, M., Baldini, N., Franciosi, G., Tortoriello, M., & Grandini, S. (2020) · Use Siena air (University of Siena) · doi:10.23805/jo.2020.12.01.11 · Cited by 9
“demonstrated that N95 respirators were highly effective in filtering microbial particles when they were tightly sealed/adapted to the shape of the face (31).”
BackgroundBasham, C., Cerles, A. A., Rush, M., Alexander-Scott, M., Greenawald, L. A., Chiu, S. K., Broadwater, K., Hirst, D., SNAWDER, J. E., Roberts, J., et al. (2021) · NEW SOLUTIONS A Journal of Environmental and Occupational Health Policy · doi:10.1177/10482911211039566 · Cited by 9
“75 mm and larger.(19) A 2009 study of NIOSH-approved FFRs found that penetrations from a 0.”
BackgroundMáscaras de tecido na prevenção da COVID-19: expectativa ou realidade?
Araruna, F. O. S., Moraes, M. B. C., Araruna, F. B., Luz, T. R. S. A., Serejo, A. P. M., do Amaral, F. M. M., & Coutinho, D. F. (2021) · Revista de Saúde Coletiva da UEFS · doi:10.13102/rscdauefs.v11i1.5929 · Cited by 9
Hossaini, H., Pirsaheb, M., Barzegar, A., Abdi, K., & Derakhshan, A. A. (2022) · Atmospheric Pollution Research · doi:10.1016/j.apr.2022.101619 · Cited by 8
Surfactant-Impregnated MOF-Coated Fabric for Antimicrobial Applications
Schwenk, G. R., Glass, A. M., Ji, H., Ehrlich, G. D., Navas, S., Król, J. E., & Hall, D. C. (2023) · ACS Applied Bio Materials · doi:10.1021/acsabm.2c00860 · Cited by 8
Prevention of COVID-19 Infection with Personal Protective Equipment
Shimasaki, N., & Morikawa, H. (2021) · Journal of Disaster Research · doi:10.20965/jdr.2021.p0061 · Cited by 8
Kumar, A., Subramanian, V., Shailesh, J., & Venkatraman, B. (2022) · Journal of Industrial Textiles · doi:10.1177/15280837221090663 · Cited by 8
“The NIOSHcertified N95 mask could filter out all particles, including bacteria and viruses, more than 95% for MPPS.20,27,28 [21, 28, 29].”
BackgroundInfluentialTotal outward leakage of half-mask respirators and surgical masks used for source control
Myers, W. R., Yang, W., Ryan, K. J., Bergman, M. S., Fisher, E. M., Soo, J., & Zhuang, Z. (2023) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2023.2257254 · Cited by 8
“The National Institute for Occupational Safety and Health (NIOSH) Approved N95 filtering facepiece respirators (FFRs) were found to have at least 95% filtration efficiency against aerosols of bacteria, NaCl, and polystyrene latex particles in the size range of 0.1 to 0.3 l m (Qian et al. 1998).”
BackgroundInfluentialAdvanced testing method to evaluate the performance of respirator filter media
Wang, Q., Golshahi, L., & Chen, D. (2016) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2016.1177647 · Cited by 8
Gangadhari, R. K., Tarei, P. K., Chand, P., Rabiee, M., & Delen, D. (2024) · Computers & Industrial Engineering · doi:10.1016/j.cie.2024.109962 · Cited by 7
Cramer, C. L., Armstrong, B. L., Trofimov, A. A., Wang, P. L., Siddel, D., Wang, H., Cakmak, E., Klett, J. W., & Elliott, A. (2021) · International Journal of Applied Ceramic Technology · doi:10.1111/ijac.13852 · Cited by 7
Particle Count Statistics Applied to the Penetration of a Filter Challenged with Nanoparticles
O’Shaughnessy, P. T., & Schmoll, L. H. (2013) · Aerosol Science and Technology · doi:10.1080/02786826.2013.778954 · Cited by 7
“This method was used, for example, to determine the collection efficiency of aerosol samplers (Harper et al., 1998; Mark and Vincent, 1986) and respirator filters (Lee and Liu, 1982; Qian et al., 1998; Stevens and Moyer, 1989).”
Smart and Connected Mask for Protection beyond the Pandemic : (Invited Paper)
Masna, N. V. R., Kalavakonda, R. R., Dizon-Paradis, R. N., & Bhunia, S. (2021) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas47672.2021.9531802 · Cited by 7
Davidson, C. S., Green, C. F., Panlilio, A. L., Jensen, P. A., Stover, B. H., Roselle, G. A., Gibbs, S. G., & Scarpino, P. V. (2010) · Indoor and Built Environment · doi:10.1177/1420326x10378805 · Cited by 7
Controversies in CO2 Insufflation and COVID-19
Soliman, M. K. (2020) · Techniques in Coloproctology · doi:10.1007/s10151-020-02237-2 · Cited by 7
Bioburden Variation of Filtering Face Piece Respirators over Time: A Preliminary Study
Checchi, V., Montevecchi, M., Valeriani, L., & Checchi, L. (2022) · Materials · doi:10.3390/ma15248790 · Cited by 6
“Respirators are designed as inhalational protection devices and are defined as Personal Protection Equipment (PPE) for their marked protective benefits [22,23].”
BackgroundProtective Masks Utilizing Nonendangered Components
Griffin, L., Yu, M., Cloet, A., Arnold, S. F., Carlson, N. G., Hillmyer, M. A., Ou, Q., Pei, C., Cao, Q., Pui, D. Y. H., et al. (2022) · Journal of Medical Devices · doi:10.1115/1.4053720 · Cited by 6
Chong, L. S., Bundele, A., Sumner, J., & Mukhopadhyay, A. (2022) · Journal of Hospital Infection · doi:10.1016/j.jhin.2022.03.004 · Cited by 6
Cass, H. G., Hanlon, G. C., McKenzie, D. P., Harley, N. S., Kelly, D. N., & Barrett, J. A. (2022) · Australian Critical Care · doi:10.1016/j.aucc.2022.08.012 · Cited by 6
Assessment of Different Experimental Setups to Determine Viral Filtration Efficiency of Face Masks
Filipić, A., Fric, K., Ravnikar, M., & Kogovšek, P. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192215353 · Cited by 6
Seo, S., Ruzycki, C. A., Finlay, W. H., Romanyk, D. L., & Martin, A. R. (2023) · American Journal of Infection Control · doi:10.1016/j.ajic.2023.01.010 · Cited by 7
Zhou, C., Ding, Y., & Ye, L. (2024) · Environmental Science and Pollution Research · doi:10.1007/s11356-024-32037-2 · Cited by 6
“Considering that the filtration efficiency of the N95 mask is 95% (Qian et al. 1998), θ is set to 5%.”
Harrop, T., Aird, J., & Thwaites, G. E. (2011) · BMJ · doi:10.1136/bmj.d1544 · Cited by 6
“Masks and respirators are effective at preventing infections,”
BackgroundThe effect of facial expressions on respirators contact pressures
Cai, M., Shen, S., & Li, H. (2017) · Computer Methods in Biomechanics & Biomedical Engineering · doi:10.1080/10255842.2017.1336549 · Cited by 6
“The letter ‘N’ indicates that the respirator is not resistant to oil (Qian et al. 1998).”
BackgroundInfluence of expiratory flow pulsatility on the effectiveness of a surgical mask
Morris, S., McAtee, W., Capecelatro, J., & Raghav, V. (2022) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/s41370-022-00416-x · Cited by 6
“, directly through the mask) is significantly reduced [24, 25].”
BackgroundFILTRATION TEXTILES: MATERIALS, PRODUCTION PROCESSES AND APPLICATION AREAS
Aslan, S., & Kaplan, S. (2010) · Tekstil ve Mühendis · Cited by 6
Bilio-pancreatic endoscopy during COVID-19 pandemic
Bove, V., Schepis, T., Boškoski, I., Landi, R., Orlandini, B., Pontecorvi, V., Familiari, P., Tringali, A., Perri, V., & Costamagna, G. (2020) · Therapeutic Advances in Gastroenterology · doi:10.1177/1756284820935187 · Cited by 6
Self-Assessment Adaptive Capacity Indicators of Health Risks from Air Pollution
Thanvisitthpon, N. T., Rintra, J., Sittiprapaporn, P., Bumrungpert, A., & Trakulkongsmut, P. (2021) · Sustainability · doi:10.3390/su132313141 · Cited by 7
Metadata
- Authors
- Qian, Y., Willeke, K., Grinshpun, S. A., Donnelly, J., & Coffey, C. C.
- Affiliations
- University of Cincinnati (US)
- Centers for Disease Control and Prevention (US)
- ORCID
- Grinshpun, Sergey A.
- Venue
- American Industrial Hygiene Association Journal
- Publisher
- Informa UK Limited
- Published
- 1998-02
- Volume
- 59
- Issue
- 2
- Pages
- 128-132
- ISSN
- 0002-8894 (ISSN-L)
- OpenAlex
- W2110642136
- Semantic Scholar
- d74dd53b1e298bfe66b53b460e63b1ab5e1a8100
- Cited by
- 298
- References
- 12
- Citations by year
- 2026: 7 · 2025: 3 · 2024: 20 · 2023: 21 · 2022: 34 · 2021: 50 · 2020: 44 · 2019: 3 · 2018: 3 · 2017: 4 · 2016: 9 · 2015: 6 · 2014: 7 · 2013: 15 · 2012: 5
- FWCI
- 1.34
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Industrial Hygiene Association Journal (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute for Occupational Safety and Health (R01-OH03244)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Keywords
- N95 respirators, particulate respirators, filtration efficiency, airborne bacteria, inert particles, Mycobacterium tuberculosis, surgical masks, face seals, welding fumes, submicron particles
- MeSH terms
- Aerosols, Air Microbiology, Air Pollution, Equipment Design, Filtration, Humans, Mycobacterium tuberculosis, Particle Size, Respiratory Protective Devices, United States
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.