Performance of N95 Respirators: Filtration Efficiency for Airborne Microbial and Inert Particles
The DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
In 1995 the National Institute for Occupational Safety and Health issued new regulations for nonpowered particulate respirators (42 CFR Part 84). A new filter certification system also was created. Among the new particulate respirators that have entered the market, the N95 respirator is the most commonly used in industrial and health care environments. The filtration efficiencies of unloaded N95 particulate respirators have been compared with those of dust/mist (DM) and dust/fume/mist (DFM) respirators certified under the former regulations (30 CFR Part 11). Through laboratory tests with NaCl certification aerosols and measurements with particle-size spectrometers, N95 respirators were found to have higher filtration efficiencies than DM and DFM respirators and noncertified surgical masks. N95 respirators made by different companies were found to have different filtration efficiencies for the most penetrating particle size (0.1 to 0.3 micron), but all were at least 95% efficient at that size for NaCl particles. Above the most penetrating particle size the filtration efficiency increases with size; it reaches approximately 99.5% or higher at about 0.75 micron. Tests with bacteria of size and shape similar to Mycobacterium tuberculosis also showed filtration efficiencies of 99.5% or higher. Experimental data were used to calculate the aerosol mass concentrations inside the respirator when worn in representative work environments. The penetrated mass fractions, in the absence of face leakage, ranged from 0.02% for large particle distributions to 1.8% for submicrometer-size welding fumes. Thus, N95 respirators provide excellent protection against airborne particles when there is a good face seal.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“Inward leakage due to gaps in the fit has been demonstrated to play a critical role in the ability of a mask or respirator to protect against exposure to particulates [4, 59, 82–84].”
From The protective performance of reusable cloth face masks, disposable procedure masks, KN95 masks and N95 respirators: Filtration and total inward leakage (2021) · cites this paper as [83]
In the citing paper
“They have at least 95% filtration efficiency for NaCl particles sized 0.1 to 0.3 𝜇 m with even higher filtration efficiency at higher particle size (approximately 99.5% or higher for 0.75 𝜇 m particles). 5”
From Assessment of N95 and K95 respirator decontamination: fiber integrity, filtration efficiency, and dipole charge density (2020) · cites this paper as [5]
In the citing paper
“with an average aerodynamic diameter reported to range from approximately 0.8-1.1 µm.(14,16,17)”
From Performance of Conventional and Antimicrobial-Treated Filtering Facepiece Respirators Challenged with Biological Aerosols (2012) · cites this paper as [16]
In the citing paper
“Moreover, previous studies have shown agreement between physical penetrations of inert and biological aerosols at particle sizes of 1 µm and above.(13,16,24,31,32)”
From Performance of Conventional and Antimicrobial-Treated Filtering Facepiece Respirators Challenged with Biological Aerosols (2012) · cites this paper as [16]
In the citing paper
“wearing surgical or FFP2 masks substantially reduces the number of bioaerosol particles emitted from human respiration.”
From Bacteria Filtration Efficiency for Different Types of Protective Face Masks (2023) · cites this paper as [26]
1 more claim about this paper
Create a free account to see every claim other papers make about this one.
Citations
Cites
Aerosol penetration and leakae characteristics of masks used in the health care industry
Weber, A. M., Willeke, K., Marchloni, R., Myojo, T., McKay, R. T., Donnelly, J., & Liebhaber, F. B. (1993) · American Journal of Infection Control · doi:10.1016/0196-6553(93)90027-2 · Cited by 156
Self-citationChen, S.-K., Vesley, D., Brosseau, L. M., & Vincent, J. H. (1994) · American Journal of Infection Control · doi:10.1016/0196-6553(94)90116-3 · Cited by 124
Penetration of Airborne Microorganisms Through a Surgical Mask and a Dust/Mist Respirator
Willeke, K., Qian, Y., Donnelly, J., Grinshpun, S., & Ulevicius, V. (1996) · American Industrial Hygiene Association Journal · doi:10.1080/15428119691014882 · Cited by 84
Self-citationCalibration and performance of an API Aerosizer
Cheng, Y., Barr, E. B., Marshall, I. A., & Mitchell, J. P. (1993) · Journal of Aerosol Science · doi:10.1016/0021-8502(93)90034-7 · Cited by 58
Efficacy of Selected Respiratory Protective Equipment Challenged with Bacillus subtilis subsp. niger
Johnson, B., Martin, D. D., & Resnick, I. G. (1994) · Applied and Environmental Microbiology · doi:10.1128/aem.60.6.2184-2186.1994 · Cited by 44
STEVENS, G. A., & MOYER, E. S. (1989) · American Industrial Hygiene Association Journal · doi:10.1080/15298668991374615 · Cited by 39
AEROSOL PENETRATION THROUGH FILTERING FACEPIECES AND RESPIRATOR CARTRIDGES
Chen, C. C., Lehtimäki, M., & Willeke, K. (1992) · American Industrial Hygiene Association Journal · doi:10.1080/15298669291360166 · Cited by 37
Self-citationRESPIRATOR PERFORMANCE RATING TABLE FOR MASK DESIGN
Johnson, A. T., Weiss, R. A., & Grove, C. M. (1992) · American Industrial Hygiene Association Journal · doi:10.1080/15298669291359500 · Cited by 37
Dynamic size spectrometry of airborne microorganisms: Laboratory evaluation and calibration
Qian, Y., Willeke, K., Ulevičius, V., Grinshpun, S. A., & Donnelly, J. (1995) · Atmospheric Environment · doi:10.1016/1352-2310(95)00043-x · Cited by 37
Self-citationHan, D.-H., Willeke, K., & Colton, C. E. (1997) · American Industrial Hygiene Association Journal · doi:10.1080/15428119791012874 · Cited by 29
Self-citation
Cited by
Items 201–300 of 326
Hong, J., Byun, J., Choi, J.-O., Shim, D., & Rha, D. (2022) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph192114106 · Cited by 6
Bacteria Filtration Efficiency for Different Types of Protective Face Masks
Linšak, Ž., Ražov, L., Furlan, N., Begić, G., Pavičić Žeželj, S., Crvelin, G., Broznić, D., & Tomić Linšak, D. (2023) · Applied Sciences · doi:10.3390/app13105972 · Cited by 5
Cheraghian, S., Hossaini, H., Pirsaheb, M., & Abdi, K. (2025) · Journal of Hazardous Materials Advances · doi:10.1016/j.hazadv.2025.100633 · Cited by 5
Prediction of N95 Respirator Fit from Fogging of Eyeglasses: A Pilot Study
Kyaw, S., Johns, M., Lim, R., Stewart, W. C., Rojas, N., Thambiraj, S. R., Shehabi, Y., & Arora, S. (2021) · Indian Journal of Critical Care Medicine · doi:10.5005/jp-journals-10071-23947 · Cited by 5
Personalized Fitting of Respiratory Mask Using 3D Numerical Simulation and Finite Element Analysis
Taeckens, H., AGOSTINI, A., Degueldre, L., Hachem, B., VIENS, S.-P., CASTONGUAY-HENRI, A., BORDUAS, J., & Duong, L. (2022) · International Conference on 3D Body Scanning Technologies (3DBST) · doi:10.15221/22.48 · Cited by 5
“It is widely used in both medical and industrial environments because of its high filtration capacity: 99.5% for particles larger than 0.75µm and 95% (smallest filtration) for particles between 0.1 and 0.3µm [7,8,9].”
MethodInfluentialDesign and testing of a sew-free origami mask for improvised respiratory protection
Realmuto, J. D., Kleinman, M. T., Sanger, T. D., Lawler, M. J., & SMITH, J. N. M. (2023) · Nanotechnology · doi:10.1088/1361-6528/acf3f3 · Cited by 5
“Respirators, such as N95 masks, seal around the face to protect the user by fi ltering contaminated droplets and aerosol particles [ 10, 20 ] and are more effective than surgical masks at preventing expelled air leakage during coughing [ 21 ] .”
Profilaxis de las infecciones en el paciente neutropénico
Uriburu, C., & Rovira, M. (2005) · Enfermedades Infecciosas y Microbiología Clínica · doi:10.1157/13091241 · Cited by 5
Self-Charging Textile Woven from Dissimilar Household Fibers for Air Filtration: A Proof of Concept
Fine, S. G., He, P., & Huang, J. (2021) · ACS Omega · doi:10.1021/acsomega.1c03412 · Cited by 5
González-Fialkowski, J. M., Wang, L., Li, Y., & Xu, X. G. (2021) · Analytical Chemistry · doi:10.1021/acs.analchem.1c03659 · Cited by 5
Elbehairy, D. M., Osman, R., & Sammour, O. A. (2016) · International Journal of Pharmacy and Pharmaceutical Sciences · Cited by 5
Zafarghandi, M. M., Akbari, A., & Mahmoudian, M. (2024) · Polymer Bulletin · doi:10.1007/s00289-024-05449-w · Cited by 4
Torres-Hernández, K. J., & Sevilla-Reyes, E. E. (2009) · Revista del Instituto Nacional de Enfermedades Respiratorias · Cited by 4
Consistency and Reproducibility of Bioaerosol Delivery for Infectivity Studies on Mice
Stone, B. R. (2010) · Cited by 4
Filtration efficiency of different protective masks against viral aerosols
Brochu, V., Turgeon, N., Richer-Fortin, A., Veillette, M., & Duchaine, C. (2024) · Aerosol Science and Technology · doi:10.1080/02786826.2024.2420683 · Cited by 4
“On another side, at increased velocities, particles larger than 1 m m have greater inertia and can impact on the filtering membrane by interception more efficiently (Alderman et al. 2008; Qian et al. 1998; Tcharkhtchi et al. 2021; Wang et al. 2023).”
COVID-19: What we talk about when we talk about masks
Fortaleza, C. R., de Souza, L. D. R., Rúgolo, J. R. M., & Fortaleza, C. M. C. B. (2020) · Revista da Sociedade Brasileira de Medicina Tropical · doi:10.1590/0037-8682-0527-2020 · Cited by 4
Aerosol generation during cadaveric simulation of otologic surgery and live cochlear implantation
Sharma, D., Campiti, V. J., Ye, M. J., Saltagi, M. Z., Carroll, A. E., Ting, J. Y., Illing, E. A., Park, J. H., Nelson, R. F., & Burgin, S. J. M. (2020) · Laryngoscope Investigative Otolaryngology · doi:10.1002/lio2.506 · Cited by 4
“8% mask penetration with particles less than 1 μm.(16)”
BackgroundLee, J. (2009) · Cited by 4
Ferguson, D. D. (2012) · doi:10.17077/etd.q87vbt68 · Cited by 4
“* M= median, R= range Non-respirable (particles > 5 um) Respirable (particles < 5 um) Sampling Date Inside M (R) (particles/liter) Downwind M (R ) (particles/lite r) Inside M (R) (particles/liter) Downwind M (R) (particles/liter) 11/9/2010 278 (80-619) 2 (0-31) 720 (307-21250) 150 (0-15,679) 11/10/2010 325 (84-920) 2…”
Mahmoudian, M., & Zanbili, F. (2024) · Chinese Journal of Polymer Science · doi:10.1007/s10118-024-3205-6 · Cited by 3
Li, X., Fan, J., Li, J., Chen, Z., Xu, R., Yang, W., He, X., & Tu, J. Y. (2026) · Physics of Fluids · doi:10.1063/5.0336215 · Cited by 3
Pike, W. Y., Proctor, M. D., & Burgess, D. N. (2017) · Military Medicine · doi:10.7205/milmed-d-16-00005 · Cited by 3
Yang, W., Myers, W. R., Bergman, M., Fisher, E. M., Ryan, K. J., Vollmer, B., Portnoff, L., & Zhuang, Z. (2024) · Aerosol Science and Technology · doi:10.1080/02786826.2024.2427282 · Cited by 3
“Other studies have shown that the most penetrating particle size (MPPS) of N95 FFRs against charge-neutralized NaCl aerosols was in a range of 0.03–0.3 l m (Shaffer and Rengasamy 2009; Lee, Grinshpun, and Reponen 2008; Balazy et al. 2006; Qian et al. 1998).”
InfluentialDentistry and COVID-19: A current view
Universidad Señor de Sipán. Chiclayo, P., Mondragón, J. P. P., Alvarez, H., & Centro Médico Odontológico Americano. Chiclayo, P. (2020) · Journal Of Oral Research · doi:10.17126/joralres.2020.047 · Cited by 3
Are the users of Valved N95 masks ‘innocent spreaders’ of COVID-19?
Bawa, A., Wander, G., & Mahajan, R. (2020) · Journal of Anaesthesiology Clinical Pharmacology · doi:10.4103/joacp.joacp_387_20 · Cited by 3
“3 microns, including the SARS‐CoV‐2.[1] These masks are better than surgical masks for self‐protection and are recommended for health care workers.”
BackgroundInfluentialChanging perception of pediatric dental practice during global COVID-19 pandemic: The new normal
Singhal, Y., Srivastava, N., Rana, V., & Kaushik, N. (2021) · International Journal of Applied Dental Sciences · doi:10.22271/oral.2021.v7.i2d.1213 · Cited by 3
Bray, C., & Vanberkel, P. T. (2023) · Health Policy · doi:10.1016/j.healthpol.2023.104857 · Cited by 3
“not reflect reality [3] - Filtration efficiency testing – - Filtration protection”
Khumyrzakh, B., Cheng, Y.-C., Lai, C.-Y., Chang, K., & Tseng, C. (2023) · Indoor Air · doi:10.1155/2023/8484714 · Cited by 3
“Among FFRs, the N95 respirator exhibits a fi ltration e ffi - ciency of at least 95% or higher when it is used to capture bacteria or viruses [9].”
BackgroundResultInfluentialWang, G., Luo, C., Cui, C., & Huang, J. (2024) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2024.2311295 · Cited by 3
“…known that the use of an N95 is superior to surgical masks in preventing respiratory infections; however, only when a good fit is achieved and the respirator is worn correctly, can respirators play a protective role in the health and safety of healthcare workers (Qian et al. 1998; Yu et al. 2012).”
BackgroundLee, J., & Wu, C. (2006) · Defense Technical Information Center (DTIC) · Cited by 3
Personal Respiratory Protection
McCullough, N. V. (2016) · ASM Press eBooks · doi:10.1128/9781555819637.ch21 · Cited by 3
Medina, D. E. (2009) · Digital Commons - University of South Florida (University of South Florida) · Cited by 3
Bowers, C. A., Randall, J. A., Jones, C., Prast, E., Li, X., Mosca, D. A., Rasansky, R., Linden, K. G., Blatchley, E. R., & Ducoste, J. J. (2025) · ACS ES&T Engineering · doi:10.1021/acsestengg.4c00803 · Cited by 2
Jin, Y., Liu, J., Liu, Z., Yuan, Y., Cui, H., Dong, Z., Zhang, F., Lv, M., Hu, L., Zhang, L., et al. (2026) · Environmental Pollution · doi:10.1016/j.envpol.2026.128796 · Cited by 2
Particle Filtration Efficiency Testing of Sterilization Wrap Masks
Chau, D. F., O’Shaughnessy, P. T., & Schmitz, M. L. (2020) · Journal of Preventive Medicine and Public Health · doi:10.3961/jpmph.20.394 · Cited by 2
“Due to the intrinsic characteristics of N95 filtering media, particles sizes below and above the MPPS are effectively blocked with greater than 95% efficiency [7,8].”
BackgroundSingh, A. K., Dey, R., Deokar, U. V., Ganesh, G., Kulkarni, M. S., & Anand, S. (2022) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncac084 · Cited by 2
An overview of the attributes of face masks in the new normal
Malhotra, V., Kakaria, R., & Singh, N. C. (2022) · International Journal of Home Science · doi:10.22271/23957476.2022.v8.i2a.1307 · Cited by 2
Sterr, C., Dick, A., Schellenberger, L., Zirbes, J., Nonnenmacher, C., & Günther, F. (2022) · Canadian Journal of Infectious Diseases and Medical Microbiology · doi:10.1155/2022/6978661 · Cited by 2
“Particles of larger size are usually better filtrated by the same material [14].”
BackgroundComparing Aerosol Generation in Human and Animal Tissues During Common Otolaryngology Procedures
Nielson, C., Kelly, K. E., Attah, R., Pei, Z., Wang, Y., Firpo, M. A., & Park, A. H. (2023) · Otolaryngology · doi:10.1002/ohn.403 · Cited by 2
The risk of aerosol transmission of respiratory infectious diseases in the isolation ward
Guo, W., Li, P., Liu, S., Xu, X., & Liu, L. (2023) · Chinese Science Bulletin (Chinese Version) · doi:10.1360/tb-2023-0765 · Cited by 2
Wang, S., Cohen, J. B., Wang, X., Chen, W., Deng, W., Tiwari, P., Yang, Y., & Lolli, S. (2023) · Environmental Research Communications · doi:10.1088/2515-7620/ad1422 · Cited by 2
Microscopy of Woven and Nonwoven Face Covering Materials: Implications for Particle Filtration
Vicenzi, E. P., Whittaker, S., Weaver, J. L., Staymates, M. E., Radney, J. G., & Zangmeister, C. D. (2024) · Microscopy and Microanalysis · doi:10.1093/micmic/ozad138 · Cited by 2
Design and Evaluation of Face Mask Filtration: Mechanisms, Formulas, and Fluid Dynamics Simulations
Pisapia, F., Rees, D., & Rasekh, M. (2024) · Applied Sciences · doi:10.3390/app14135432 · Cited by 2
“This behaviour was confirmed by Qian et al. [12] and Richardson et al. [6], who analyzed the relationship between flow rate and particle penetration, showing that these are directly proportional.”
BackgroundPurpose and performance of respiratory protective devices in a pandemic
Li, R., Joshi, A., Wu, Y., & Zhang, M. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95316-0.00003-7 · Cited by 2
Rapid diagnosis of tuberculosis in a peripheral setting
Pienaar, E. (2010) · Lincoln (University of Nebraska) · Cited by 2
Olson, C., Landsberger, S., & Braisted, J. (2007) · Journal of Radioanalytical and Nuclear Chemistry · doi:10.1007/s10967-007-0425-5 · Cited by 2
Nakandakari, M. D., la Rosa, D. N. D., Gutierrez, J., & Bryson, W. (2014) · Revista Médica Herediana · doi:10.20453/rmh.2014.1989 · Cited by 2
Ferguson, D. D., Smith, T. C., Donham, K. J., & O’Shaughnessy, P. T. (2014) · Journal of Agricultural Safety and Health · doi:10.13031/jash.20.10450 · Cited by 2
I Smell Smoke—The Must Know Details About the N95
Carr-Locke, D. L., Soetikno, R. M., Shah, S. L., Kaltenbach, T. R., & Shergill, A. K. (2020) · The American Journal of Gastroenterology · doi:10.14309/ajg.0000000000000785 · Cited by 2
“Thus, fit testing is different from testing of filtration efficiency because both aerosolized chemicals will be blocked by the mask and will only be detected by the wearer if there is a leak when the wearer inhales (6).”
BackgroundTypes of face coverings (masks) and coronavirus disease 2019 (COVID-19)
Anjum, S., & Islam, T. (2021) · European Journal of Biological Research · doi:10.5281/zenodo.5068414 · Cited by 2
Combating the COVID-19 Pandemic Using 3D Printed PPE: Challenges and Recommendations
Amir, A. A., & Amir, B. A. (2022) · The Open Public Health Journal · doi:10.2174/18749445-v15-e2206010 · Cited by 2
FILTER PERFORMANCE UNDER SIMULATED REAL-WORLD CONDITIONS
Wang, Q. (2016) · VCU Scholars Compass (Virginia Commonwealth University) · doi:10.25772/cr0p-td41 · Cited by 2
Sharma, A. (2000) · The Research Repository @ WVU (West Virginia University) · doi:10.33915/etd.10508 · Cited by 2
Biodegradable Bio-based Material for Wearable Air Filtering Skin
Gardner, J. D., Kao, H.-L., & Netravali, A. N. (2022) · ACM International Joint Conference on Pervasive and Ubiquitous Computing (UbiComp) · doi:10.1145/3544793.3560320 · Cited by 1
“3 micrometer (300nm) sized particles at 95 % [18].”
BackgroundDETERMINATION OF THE INTERNAL EXPOSURE HAZARD FROM PLUTONIUM WORK IN AN OPEN FRONT HOOD
Olson, C., Landsberger, S., & Moore, M. E. (2010) · Health Physics · doi:10.1097/hp.0b013e3181de04d0 · Cited by 1
“(Qian et al., 1998).”
Lin, B. K., Munter, B. T., Pascavis, K. S., Nakaji, P., & Nicolasora, N. P. (2021) · Infectious Diseases in Clinical Practice · doi:10.1097/ipc.0000000000001059 · Cited by 1
Wen, Z., Li, N., Li, J., Wang, J., Zhao, J., Yang, W., Hu, L., Dong, X., & Lu, J. (2012) · Applied Biosafety · doi:10.1177/153567601201700106 · Cited by 1
“Studies on respiratory protection against TB were carried out with nonpathogenic bacteria having 29 www.absa.org Applied Biosafety Vol. 17, No. 1, 2012 physical characteristics similar to that of M. tuberculosis (Brosseau et al., 1997; Chen et al., 1994; Qian et al., 1998).”
ResultBhattacharya, S., Joy, V. M., & Vivek, P. (2020) · Journal of The Academy of Clinical Microbiologists · doi:10.4103/jacm.jacm_8_20 · Cited by 1
Jung, S., Yi, J., & Kim, J. (2020) · Journal of Industrial Textiles · doi:10.1177/1528083720955202 · Cited by 1
He, X., Reponen, T. A., McKay, R. T., & Grinshpun, S. A. (2021) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2021.1877069 · Cited by 1
“tama~ no.((5,7,16)) Esto sugiere que los sustitutos de aerosoles inertes, como las part ıculas de NaCl, pueden”
BackgroundSelf-citationControl de la fuente respiratoria mediante el uso de una mascarilla quirúrgica: un estudio in vitro
Patel, R. B., Skaria, S. D., Mansour, M. M., & Smaldone, G. C. (2021) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2021.1877068 · Cited by 1
“1016/0195-6701(93)90130-R [6] Qian, Y.”
Alteration of Perceptions of Safety Before and After Fit Testing among College of Dentistry Students
Clark, T. H. (2021) · DigitalCommons@UNMC · Cited by 1
EEG çalışmalarında viral enfeksiyon bulaşma riskini azaltma yönergeleri
Hasşerbetçi, S., & Günseli, E. (2021) · Türkiye Halk Sağlığı Dergisi · doi:10.20518/tjph.840203 · Cited by 1
Young, S. K., Pollard, R. J., & Shapiro, F. E. (2021) · Advances in Anesthesia · doi:10.1016/j.aan.2021.07.006 · Cited by 1
Deniz, E., Şibar, S., Kılıç, Ö., & Ayhan, S. (2021) · Turkish Journal of Plastic Surgery · doi:10.4103/tjps.tjps_105_20 · Cited by 1
Geng, Y., Zhao, L., & Jepsen, S. D. (2022) · Biosystems Engineering · doi:10.1016/j.biosystemseng.2022.05.020 · Cited by 1
Inolopú-Cucche, J., Mayma-Aguirre, K. J., Curisinche-Rojas, M., Aylas, R., Flores, J. A., & Rosales‐Rimache, J. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20166618 · Cited by 1
Bahloul, A., Haghighat, F., Mostofi, R., Mahdavi, A., & Ostiguy, C. (2016) · PhareSST · Cited by 1
A Sew-Free Origami Mask for Improvised Respiratory ProtectionPreprint
Realmuto, J. D., Kleinman, M. T., Sanger, T. D., Lawler, M. J., & SMITH, J. N. M. (2020) · medRxiv · doi:10.1101/2020.09.29.20204115 · Cited by 1
Al‐Moraissi, E. A., Abood, M. M., Alasseri, N. A., Günther, F. A., & Neff, A. (2020) · medRxiv · doi:10.1101/2020.11.20.20235333 · Cited by 1
“…and N100 protection masks are at least 94-95% and 99%, respectively, effective for particles tested according to the standards of the National Institute for Occupational Safety and Health (NIOSH), which increases to 99.5% or higher for particles measuring 0.75 micron or bigger (Qian et al., 1998).”
MethodInfluentialUngrin, M., Oliver, M., Wright, J. M., Mesiano‐Crookston, J., Gasperowicz, M., Fisman, D. N., & Nielson, C. (2023) · MetArXiv (OSF Preprints) · doi:10.31222/osf.io/ey7bj · Cited by 1
Eninger, R. M. (2008) · OhioLink ETD Center (Ohio Library and Information Network)
Severe Acute Respiratory Syndrome: What Have We Learned
Wei, W., & Ho, W. (2005) · Advances in Surgery · doi:10.1016/j.yasu.2005.04.001
“30 The effort to reduce the spread of disease through direct contact or droplet contact in hospitals managing these patients involved generating, implementing, and enforcing a series of guidelines.”
BackgroundGauld, J. (2014) · cIRcle (University of British Columbia) · doi:10.14288/1.0167597
Davidson, C. S. (2006) · OhioLink ETD Center (Ohio Library and Information Network)
Ventilator-Associated Pneumonia: Role of Anaerobes
Pugliese, G., & Favero, M. S. (1999) · Infection Control and Hospital Epidemiology · doi:10.1017/s019594170007020x
Assigned Protection Factors: A Perspective 3 JobHealth
Janssen, L. (2006)
Gao, S. (2016) · OhioLink ETD Center (Ohio Library and Information Network)
Design and Performance Evaluation of Face Mask Air Filtration System
Nixon, B. J. (2018) · Tuwhera (Auckland University of Technology)
Determination of the internal exposure hazard from plutonium work in an open front hood
Olson, C. L. (2006) · Texas ScholarWorks (Texas Digital Library)
Simulation-based assessment for N95 filtering facepiece respirator
Lei, Z. (2014) · ThinkTech (Texas Tech University)
Awareness Regarding COVID-19 Among Health Care Workers in a Tribal District of Chhattisgarh, India
Nag, S., Noor, S., Tiwari, A., & Gavel, S. (2021) · International Journal of Current Research and Review · doi:10.31782/ijcrr.2021.sp214
Contagions under control - Mathematical models to inform infectious disease prevention and control
Pham, T. M. (2022) · Utrecht University Repository (Utrecht University) · doi:10.33540/1194
PREVENÇÃO DA COVID-19: MANUAL TÉCNICO SOBRE USO CORRETO E SEGURO DE MÁSCARAS
Uningá, C. U. I. , Benites, C. D. S., Chierrito, D., Uningá, C. U. I. , Teston, A. P. M., Uningá, C. U. I. , Araújo, D. C. D. M., & Uningá, C. U. I. (2022) · Editora UNINGÁ eBooks · doi:10.46311/978-65-80328-03-1
Neutron activation analysis of aerosolized NaCl to simulate size fractionation of Pu in a glovebox
Olson, C., (NNSA), U. N. N. S. A., Landsberger, S., & Braisted, J. (2006) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1068205
Personal Respiratory Protection
McCullough, N. V. (2014) · ASM Press eBooks · doi:10.1128/9781555815899.ch17
Tuberculosis: una creciente amenaza para los trabajadores y estudiantes del área de la salud
(2021) · Editorial Universidad Santiago de Cali eBooks · doi:10.35985/9789585147256.5
(2007) · Wiley eBooks · doi:10.1002/9780470229842.refs
COVID-19 protective textiles for breathable face masks
Li, J., Hou, Y., Zhang, X., Tong, P., Xue, Z., & Mondal, M. I. H. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-90477-3.00011-0
Computational Modeling of Aerosol Transmission of COVID-19
Ahmadi, G. (2022) · Springer eBooks · doi:10.1007/978-981-19-1356-3_6
A constant-law model for the filtering rate of non-woven fabrics
Qin, X., Zeng, Y., & Zhang, X. J. (2022) · Journal of the Textile Institute · doi:10.1080/00405000.2022.2145433
MASI: A Novel Combination of Mask and Shield With Near-N95 Efficiency
Kalavakonda, R. R., Anbu, P., Masna, N. V. R., Dizon-Paradis, R. N., Ravi, B. B. Y., Mandal, S., & Bhunia, S. (2022) · IEEE Sensors Journal · doi:10.1109/jsen.2022.3211762
Restuti, R. D., Priyono, H., Mariska, T. C., Cahyono, A., Bramantyo, B., Soemarko, D. S., Yusuf, P. A., Arman, F., & Prihartanto, J. (2023) · Oto Rhino Laryngologica Indonesiana · doi:10.32637/orli.v52i2.581
Yamamoto, N. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-824411-1.00001-6
Yang, W. (2023) · The Research Repository @ WVU (West Virginia University) · doi:10.33915/etd.12108
de Paula, I. M. T., Rosendo, M. G., Brasil, M. H. F., Dantas, A. R. A., Nogueira, W. P., Ramalho, J. A. A., da Silva, B. E., Costa, M. A. J., & Silva, A. C. D. O. E. (2023) · Contribuciones a las Ciencias Sociales · doi:10.55905/revconv.16n.10-251
Understanding of Nanofiber Face Mask as Corona Virus Disease Prevention in Human
Prasetya, T. A. E., Dewi, I. R., Taufik, M. R., & Islam, K. F. (2024) · Health Dynamics · doi:10.33846/hd10405
“To mask, or not to mask, that is the question”: COVID (Anti)Masking and Comics
Joshi, I. A., & Venkatesan, S. (2024) · Interdisciplinary Literary Studies · doi:10.5325/intelitestud.26.1.0091
Nanomaterial’s role against SARS-CoV-2 pandemic and beyond
Singh, R., Saji, J., Saini, A., Umapathi, A., Kumawat, M., Mathur, P., & Daima, H. K. (2024) · Royal Society of Chemistry eBooks · doi:10.1039/bk9781837674138-00177
Joshi, A., & Zhang, M. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95316-0.00011-6
Metadata
- Authors
- Qian, Y., Willeke, K., Grinshpun, S. A., Donnelly, J., & Coffey, C. C.
- Affiliations
- University of Cincinnati (US)
- Centers for Disease Control and Prevention (US)
- ORCID
- Grinshpun, Sergey A.
- Venue
- American Industrial Hygiene Association Journal
- Publisher
- Informa UK Limited
- Published
- 1998-02
- Volume
- 59
- Issue
- 2
- Pages
- 128-132
- ISSN
- 0002-8894 (ISSN-L)
- OpenAlex
- W2110642136
- Semantic Scholar
- d74dd53b1e298bfe66b53b460e63b1ab5e1a8100
- Cited by
- 298
- References
- 12
- Citations by year
- 2026: 7 · 2025: 3 · 2024: 20 · 2023: 21 · 2022: 34 · 2021: 50 · 2020: 44 · 2019: 3 · 2018: 3 · 2017: 4 · 2016: 9 · 2015: 6 · 2014: 7 · 2013: 15 · 2012: 5
- FWCI
- 1.34
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- American Industrial Hygiene Association Journal (publishedVersion)
- PubMed (publishedVersion)
- Funders
- National Institute for Occupational Safety and Health (R01-OH03244)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Aerosol Filtration and Electrostatic Precipitation
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Keywords
- N95 respirators, particulate respirators, filtration efficiency, airborne bacteria, inert particles, Mycobacterium tuberculosis, surgical masks, face seals, welding fumes, submicron particles
- MeSH terms
- Aerosols, Air Microbiology, Air Pollution, Equipment Design, Filtration, Humans, Mycobacterium tuberculosis, Particle Size, Respiratory Protective Devices, United States
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.