Respiratory Protection Provided by N95 Filtering Facepiece Respirators Against Airborne Dust and Microorganisms in Agricultural Farms
The DOI matches its Crossref record; 17 of the 18 references it cites were found in a registry or an index.
Abstract
A new system was used to determine the workplace protection factors (WPF) for dust and bioaerosols in agricultural environments. The field study was performed with a subject wearing an N95 filtering facepiece respirator while performing animal feeding, grain harvesting and unloading, and routine investigation of facilities. As expected, the geometric means (GM) of the WPFs increased with increasing particle size ranging from 21 for 0.7-1 microm particles to 270 for 5-10 microm particles (p < 0.001). The WPF for total culturable fungi (GM = 35) was significantly greater than for total culturable bacteria (GM = 9) (p = 0.01). Among the different microorganism groups, the WPFs of Cladosporium, culturable fungi, and total fungi were significantly correlated with the WPFs of particles of the same sizes. As compared with the WPFs for dust particles, the WPFs for bioaerosols were found more frequently below 10, which is a recommended assigned protection factor (APF) for N95 filtering facepiece respirators. More than 50% of the WPFs for microorganisms (mean aerodynamic diameter < 5 microm) were less than the proposed APF of 10. Even lower WPFs were calculated after correcting for dead space and lung deposition. Thus, the APF of 10 for N95 filtering facepiece respirators seems inadequate against microorganisms (mean aerodynamic size < 5 microm). These results provide useful pilot data to establish guidelines for respiratory protection against airborne dust and microorganisms on agricultural farms. The method is a promising tool for further epidemiological and intervention studies in agricultural and other similar occupational and nonoccupational environments.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“On the other hand, the WPF for the elastomeric respirator was clearly higher than the values obtained for the N-95 respirator in this study and in the previous agricultural study (Lee et al. 2005).”
From Mold and Endotoxin Levels in the Aftermath of Hurricane Katrina: A Pilot Project of Homes in New Orleans Undergoing Renovation (2006) · cites this paper as Lee et al. 2005
In the citing paper
“In a previous study (Lee et al. 2005) in which the WPF against fungal spores was measured in agricultural environments, the geometric mean and geometric standard deviation of 21 WPF data points was 25 and 9.9, respectively.”
From Mold and Endotoxin Levels in the Aftermath of Hurricane Katrina: A Pilot Project of Homes in New Orleans Undergoing Renovation (2006) · cites this paper as Lee et al. 2005
In the citing paper
“In addition, the WPF decreased with decreasing spore size.”
From Mold and Endotoxin Levels in the Aftermath of Hurricane Katrina: A Pilot Project of Homes in New Orleans Undergoing Renovation (2006) · cites this paper as Lee et al. 2005
In the citing paper
“This study showed that WPF increases with increased particle size.”
From Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow (2009) · cites this paper as Lee et al. (2005a)
In the citing paper
“According to the findings of Lee et al., total deposition in human respiratory tract ranges from 39 to 96% in the particle size range from 0.7 to 5 lm for adult males under medium workload (Lee et al., 2005a).This means that 4-61% of particles return to respirator cavity in human experiments versus 0% in our manikin experiments.This could cause up to 1.6 times higher PF in manikin experiments even”
From Large Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow (2009) · cites this paper as Lee et al., 2005a
Citations
Cites
Ellis, M. B. (1971) · doi:10.1079/9780851986180.0000 · Cited by 2,021
Human Respiratory Tract Model for Radiological Protection
Icrp (1994) · Annals of the ICRP · Cited by 1,767
(1942) · Social Service Review · doi:10.1086/634274 · Cited by 323
Performance of N95 Respirators: Filtration Efficiency for Airborne Microbial and Inert Particles
Qian, Y., Willeke, K., Grinshpun, S. A., Donnelly, J., & Coffey, C. C. (1998) · American Industrial Hygiene Association Journal · doi:10.1080/15428119891010389 · Cited by 298 · cited 2×
“Qian et al.(8) found that the filtration efficiency of some N95 filtering facepiece respirators is 99.”
BackgroundInfluentialSelf-citationHealth effects of indoor-air microorganisms
Husman, T. (1996) · Scandinavian Journal of Work, Environment & Health · doi:10.5271/sjweh.103 · Cited by 289
Bioaerosols: Prevalence and health effects in the indoor environment
Burger, H. (1990) · Journal of Allergy and Clinical Immunology · doi:10.1016/s0091-6749(05)80170-8 · Cited by 280
Personal Exposure to Airborne Dust and Microorganisms in Agricultural Environments
Lee, S.-A., Adhikari, A., Grinshpun, S. A., McKay, R., Shukla, R., & Reponen, T. (2006) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620500524607 · Cited by 180 · cited 1×
“Our concurrent article 14 will characterize exposures, whereas this article focuses on respiratory protection.”
BackgroundSelf-citationEffect of relative humidity on the aerodynamic diameter and respiratory deposition of fungal spores
Reponen, T., Willeke, K., Ulevicius, V., Reponen, A., & Grinshpun, S. A. (1996) · Atmospheric Environment · doi:10.1016/1352-2310(96)00128-8 · Cited by 170 · cited 1×
“7 and 10μm 9 , 10 and thus the filtration efficiency by N95 filtering facepiece respirators should be even higher than 99.”
BackgroundSelf-citationSize distribution of bacterial and fungal bioaerosols in indoor air.
Górny, R. L., Dutkiewicz, J. K., & Krysińska‐Traczyk, E. (1999) · PubMed · Cited by 131
Aerodynamic versus physical size of spores: Measurement and implication for respiratory deposition
Reponen, T., Grinshpun, S. A., Conwell, K. L., Wiest, J., & Anderson, M. (2001) · Grana · doi:10.1080/00173130152625851 · Cited by 123 · cited 3×
“The physical size and aerodynamic size of Cladosporium cladosporioides are 3.6 ± 0.7 µm and 1.8 ± 0.7 µm, respectively, as reported by Reponen et al.(19) The size of Cladosporium spp. measured in our study ranged from 7.8–16.6 µm in length and 4.3– 9.2 µm in width, while Ellis(20) reported wider ranges of the spore si…”
BackgroundMethodInfluentialSelf-citation
Research works printed but not linked: 9
- Respiratory Protection, 1998, Code of Federal Regulations Title, 29, 134
- Respiratory Protective Devices; Final Rules and Notice, 1995, Federal Register, 60, 110
- Górny R. L., 1999, Ann. Agric. Environ. Med., 6, 105
- Respiratory Protection Committee, American Industrial Hygiene Association (AIHA), 2002, Am. Ind. Hyg. Assoc. J., 63, 130
- Lee S. A., J. Occup. Environ. Hyg.
- Respiratory Protection for M. tuberculosis, 1998, Code of Federal Regulations Title, 29, pp. 442
- International Commission on Radiological Protection (ICRP), 1994, Ann. ICRP, 24
- Assigned Protection Factors; Proposed Rule, Federal Register, 68, 64036
- “Respiratory Protection” Appendix, 1998, Code of Federal Regulations Title 29
Cited by
Size‐resolved emission rates of airborne bacteria and fungi in an occupied classroom
Qian, J., Hospodsky, D., Yamamoto, N., Nazaroff, W. W., & Peccia, J. (2012) · Indoor Air · doi:10.1111/j.1600-0668.2012.00769.x · Cited by 395
“…different than that of total particulate matter, with fungal peaks during occupancy near the typically cited aerodynamic diameters of unicellular (2–5 lm) and multicellular fungal spores (>10 lm) (Eduard, 2009; Jankowska et al., 2000; Lee et al., 2005; McCartney et al., 1993; Reponen, 1995).”
BackgroundLee, S.-A., Grinshpun, S. A., & Reponen, T. (2008) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men005 · Cited by 235
“In some previous investigations, artificial leaks were created on a manikin face to examine the effect of leak shape, leak size and leak location on the particle penetration through face-seal leaks in the size range of about 0.1–5 lm (Chen and Willeke, 1992; Lee et al., 2005a).”
BackgroundMethodSelf-citationEvaluating the Efficacy of Cloth Facemasks in Reducing Particulate Matter Exposure
Shakya, K. M., Noyes, A., Kallin, R., & Peltier, R. E. (2017) · Journal of Exposure Science & Environmental Epidemiology · doi:10.1038/jes.2016.42 · Cited by 202
Personal Exposure to Airborne Dust and Microorganisms in Agricultural Environments
Lee, S.-A., Adhikari, A., Grinshpun, S. A., McKay, R., Shukla, R., & Reponen, T. (2006) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620500524607 · Cited by 180
“We have recently developed a personal sampling system,(26) which was used in a concurrent study(27) to investigate the protection provided by respirators against dust and bioaerosols in agricultural farms.”
MethodSelf-citationCorrelation of ambient inhalable bioaerosols with particulate matter and ozone: A two-year study
Adhikari, A., Reponen, T., Grinshpun, S. A., Martuzevicius, D., & LeMasters, G. (2006) · Environmental Pollution · doi:10.1016/j.envpol.2005.07.004 · Cited by 176
Self-citationRengasamy, S., Eimer, B. C., & Shaffer, R. E. (2009) · Annals of Occupational Hygiene · doi:10.1093/annhyg/men086 · Cited by 156
“…particulate filtering respirators which include filtering facepiece respirators (FFRs) is well characterized for a wide size range of aerosol particles most commonly found in workplaces (Moyer and Bergman, 2000; Lee et al., 2005; Balazy et al., 2006; Rengasamy et al., 2007; Eninger et al., 2008a).”
BackgroundLee, T., Grinshpun, S. A., Martuzevičius, D., Adhikari, A., Crawford, C. M., Luo, J., & Reponen, T. A. (2006) · Indoor Air · doi:10.1111/j.1600-0668.2005.00396.x · Cited by 163
“Several types of fungal genera such as Cladosporium and Epicoccum in outdoor air were associated with deficit in peak expiratory flow rates in children (Neas et al., 1996).”
BackgroundInfluentialSelf-citationChew, G. L., Wilson, J., Rabito, F. A., Grimsley, F., Iqbal, S., Reponen, T., Muilenberg, M. L., Thorne, P. S., Dearborn, D. G., & Morley, R. L. (2006) · Environmental Health Perspectives · doi:10.1289/ehp.9258 · Cited by 140
“On the other hand, the WPF for the elastomeric respirator was clearly higher than the values obtained for the N-95 respirator in this study and in the previous agricultural study (Lee et al. 2005).”
BackgroundMethodResultInfluentialSelf-citationLee, S.-A., Hwang, D.-C., Li, H.-Y., Tsai, C.-F., Chen, C.-W., & Chen, J.-K. (2016) · Journal of Healthcare Engineering · doi:10.1155/2016/8572493 · Cited by 134
“N95 FFRs have been widely studied for filtration efficiency [11, 12], face seal leakage [12, 13], fit factors [14, 15], and protection factors [6, 10].”
BackgroundResultSelf-citationAn upper bound on one-to-one exposure to infectious human respiratory particles
Bagheri, G., Thiede, B., Hejazi, B., Schlenczek, O., & Bodenschatz, E. (2021) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2110117118 · Cited by 144
Rengasamy, S., King, W. P., Eimer, B. C., & Shaffer, R. E. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620802275387 · Cited by 124
Protecting healthcare workers from pandemic influenza: N95 or surgical masks?
Gralton, J., & McLaws, M.-L. (2010) · Critical Care Medicine · doi:10.1097/ccm.0b013e3181b9e8b3 · Cited by 113
“Laboratory studies assessing filtering efficacy of masks Author, Date, Reference Type of Mask Challenge Particle, Size Laboratory Findings Limitations for Generalizability of Laboratory Findings Lee et al (43) N95 Surgical NaCl (0.04–1.3 m) N95 masks provided more protection than surgical masks Limited by use of inert…”
BackgroundInfluentialKara, Y., & Molnár, K. (2022) · Journal of Industrial Textiles · doi:10.1177/15280837211019488 · Cited by 97
“These biologically hazardous substances or bioaerosols might be transferred through the air, and they could cause severe health effects because of their ability to incubate, grow, multiply, and produce toxic substances [136].”
BackgroundAn aerobiological perspective of dust in cage-housed and floor-housed poultry operations
Just, N., Duchaine, C., & Singh, B. (2009) · Journal of Occupational Medicine and Toxicology · doi:10.1186/1745-6673-4-13 · Cited by 105
A Review of Filtration Performance of Protective Masks
Wang, A.-B., Zhang, X., Gao, L., Zhang, T., Xu, H., & Bi, Y. (2023) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph20032346 · Cited by 90
Systematic Review of Respiratory Health Among Dairy Workers
Reynolds, S. J., Nonnenmann, M. W., Basinas, I., Davidson, M. E., Elfman, L., Gordon, J., Kirychuk, S., Reed, S., Schaeffer, J. W., Schenker, M. B., et al. (2013) · Journal of Agromedicine · doi:10.1080/1059924x.2013.797374 · Cited by 82
Hasan, A., Lange, C. F., & King, M. (2010) · Journal of Non-Newtonian Fluid Mechanics · doi:10.1016/j.jnnfm.2010.07.005 · Cited by 52
Cummings, K. J., Cox‐Ganser, J. M., Riggs, M. A., Edwards, N. T., Hobbs, G. R., & Kreiss, K. (2008) · American Journal of Public Health · doi:10.2105/ajph.2007.118398 · Cited by 53
Cramp, G., Harte, D., DOUGLAS, N. M., Graham, F. F., Schousboe, M., & SYKES, K. (2009) · Epidemiology and Infection · doi:10.1017/s0950268809990835 · Cited by 50
“Exposure to Legionella can be eliminated or significantly reduced by wearing face masks as part of appropriate personal protective equipment, using good ventilation of the workplace and storing potting mix in cool areas [21, 22] As a result of this outbreak, we advocate the introduction of an industry standard ensurin…”
BackgroundWorkplace Protection Factors for an N95 Filtering Facepiece Respirator
Janssen, L. L., Nelson, T. J., & Cuta, K. (2007) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620701517764 · Cited by 56
“(22) Taken as a whole, these data refute the suggestion that faceseal penetration is particle size dependent, favoring the penetration of particles less that a few micrometers in size.(12,23,24)”
BackgroundMethodLee, S.-A., & Liao, C.-H. (2014) · Science of The Total Environment · doi:10.1016/j.scitotenv.2013.07.104 · Cited by 48
Self-citationReponen, T., Lee, S.-A., Grinshpun, S. A., Johnson, E., & Mckay, R. (2011) · Annals of Occupational Hygiene · doi:10.1093/annhyg/meq085 · Cited by 48
“A dehumidifier was used to minimize this effect (Lee et al., 2005b).”
BackgroundMethodResultInfluentialSelf-citationBrandl, H., Fricker-Feer, C., Ziegler, D., Mandal, J., Stephan, R., & Lehner, A. (2013) · Journal of Dairy Science · doi:10.3168/jds.2013-7028 · Cited by 47
“High total particle counts in these size classes are often associated with elevated bioaerosol concentrations (Parat et al., 1999; Lee et al., 2005; Tham and Zuraimi, 2005; Raisi et al., 2013), which was also the case in our investigations (Figure 2).”
BackgroundMadsen, A. M., Kurdi, I. M., Feld, L., & Tendal, K. (2018) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxy065 · Cited by 44
“However, in general, there are problems with the fit of filter masks (Lee et al., 2005; Winter et al., 2010), and this, together with the presence of airborne MRSA as particles smaller than 1.”
BackgroundLarge Particle Penetration through N95 Respirator Filters and Facepiece Leaks with Cyclic Flow
(2009) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mep062 · Cited by 42
Self-citationCho, K. J., Jones, S., Jones, G., McKay, R., Grinshpun, S. A., Dwivedi, A., Shukla, R., Singh, U., & Reponen, T. (2010) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2010.513910 · Cited by 40
“Lee et al.(16) reported that corresponding concentrations ranged from 4.4 × 106 to 5.8 × 107 particles/m3 at grain harvesting and from 1.7 × 106 to 2.9 × 107 particles/m3 in animal confinements.”
BackgroundResultInfluentialSelf-citationAvoiding COVID-19: Aerosol GuidelinesPreprint
Evans, M. (2020) · medRxiv · doi:10.1101/2020.05.21.20108894 · Cited by 49
“…far more effective protection for the wearer (e.g., PF of 8–80 for N95s) [64], but benefiting from them requires proper fit and user compliance [65, 66, 67, 68, 69, 70], which suggests that widespread use is likely to be ineffective with currently available respirators [71, 72, 68] Filtration of…”
Criteria for the Collection of Useful Respirator Performance Data in the Workplace
Janssen, L., Zhuang, Z., & Shaffer, R. E. (2014) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.852282 · Cited by 34
Zou, Z., & Yao, M. (2014) · Journal of Aerosol Science · doi:10.1016/j.jaerosci.2014.10.003 · Cited by 35
Archaeal characterization of bioaerosols from cage-housed and floor-housed poultry operations
Just, N., Lecours, P. B., Marcoux-Voiselle, M., Kirychuk, S., Veillette, M., Singh, B., & Duchaine, C. (2012) · Canadian Journal of Microbiology · doi:10.1139/cjm-2012-0305 · Cited by 35
Manikin-Based Performance Evaluation of Elastomeric Respirators Against Combustion Particles
He, X., Yermakov, M. V., Reponen, T. A., McKay, R. T., James, K., & Grinshpun, S. A. (2013) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.760063 · Cited by 38
Self-citationRespiratory Issues in Beef and Pork Production: Recommendations From an Expert Panel
Essen, S. V., Moore, G., Gibbs, S. G., & Larson, K. R. L. (2010) · Journal of Agromedicine · doi:10.1080/1059924x.2010.486283 · Cited by 29
Fluorescent Bioaerosol Particles Resulting from Human Occupancy with and Without Respirators
Xu, C., Wu, C., & Yao, M. (2017) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2016.09.0400 · Cited by 29
“Particle size, shape and density of airborne microorganisms were shown to have important impacts on the protection provided by N95 respirators (Lee et al. , 2005).”
Roberge, R. J. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2012.715066 · Cited by 30
“Assuming an average N95 FFR functional dead space volume of 123 mL when worn,(27) Hayashi and Tokura’s graph data would indicate a decrease of ∼1.”
BackgroundSize-Resolved Penetration of Filtering Materials from CE-Marked Filtering Facepiece Respirators
Serfozo, N., Ondráček, J., Zíková, N., Lazaridis, M., & Ždímal, V. (2017) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2016.09.0390 · Cited by 25
“…of aerosol penetration through filters using aerosols that are thought to be similar to those encountered in workplaces (Myojo and Sugimoto, 1997; Lee et al. , 2005; Rengasamy et al. , 2008; Jung et al. , 2014, Rengasamy et al. , 2015; Vo et al. , 2015; Gao et al. , 2016), while other studies…”
Xu, M., Lei, Z., & Yang, J. (2015) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2015.1019078 · Cited by 22
“Lee et al.(3) measured the RVD volume of an FFR similar to this study, and the average of their results was 123 mL.”
BackgroundMethodResultInfluentialRengasamy, S., & Eimer, B. C. (2012) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2011.642703 · Cited by 25
“Some studies also employed an optical counter (OPC) or a laser spectrometer to measure aerosol penetration through respirators.(38,39,41) OPCs are similar to photometers; however, aerosol flows through a focused light or laser beam as a thin stream surrounded by sheath air, so that only one particle at a time is count…”
BackgroundDavidson, C. S., Green, C. F., Gibbs, S. G., Schmid, K. K., Panlilio, A. L., Jensen, P. A., & Scarpino, P. V. (2013) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.818243 · Cited by 23
Penetration of Diesel Exhaust Particles Through Commercially Available Dust Half Masks
Penconek, A., Drążyk, P., & Moskal, A. (2012) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mes074 · Cited by 32
Comparison of Workplace Protection Factors for Different Biological Contaminants
Cho, K. J., Reponen, T., McKay, R., Dwivedi, A., Adhikari, A., Singh, U., Shukla, R., Jones, S., Jones, G., & Grinshpun, S. A. (2011) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2011.585094 · Cited by 14
“(35) and Lee et al.(16) reported that after correcting for respiratory deposition, protection factors decreased for all tested particle sizes (0.”
BackgroundMethodResultInfluentialSelf-citationEvaluation of a New Workplace Protection Factor–Measuring Method for Filtering Facepiece Respirator
Sun, C., Thelen, C., Sanz, I. S., & Wittmann, A. (2019) · Safety and Health at Work · doi:10.1016/j.shaw.2019.11.001 · Cited by 14
Respirator Use Among US Farm Operators: Evidence from the 2006 Farm and Ranch Safety Survey
Syamlal, G., Schleiff, P. L., Mazurek, J. M., Doney, B. C., & Greskevitch, M. F. (2013) · Journal of Agromedicine · doi:10.1080/1059924x.2012.743379 · Cited by 12
Evaluation of Low-Cost Optical Particle Counters for Agricultural Exposure Measurements
Olegario, J. M., Regmi, S., & Sousan, S. (2021) · Applied Engineering in Agriculture · doi:10.13031/aea.14091 · Cited by 12
Majchrzycka, K., Okrasa, M., Jachowicz, A., Szulc, J., Brycki, B. E., & Gutarowska, B. (2019) · Molecules · doi:10.3390/molecules24183339 · Cited by 11
Lessons from Dairy Farmers for Occupational Allergy and Respiratory Disease
Seidel, J., Magzamen, S. L., Wang, Y., Neujahr, V., & Schaeffer, J. W. (2023) · Current Allergy and Asthma Reports · doi:10.1007/s11882-023-01081-2 · Cited by 14
Casey, M., & Mazurek, J. M. (2017) · Journal of Agromedicine · doi:10.1080/1059924x.2017.1282904 · Cited by 11
Eggshells as a source for occupational exposure to airborne bacteria in hatcheries
Brauner, P., Klug, K., & Jäckel, U. (2016) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2016.1200192 · Cited by 9
Performance Evaluation of Full Facepiece Respirators with Cartridges
Lee, S.-A., Chen, Y.-L., Hwang, D.-C., Wu, C.-C., & Chen, J.-K. (2017) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2016.11.0485 · Cited by 8
“…increased with particle size, but also varied depending on the types of pollutants (e.g., dust, fungi, bacteria, endotoxin, (1 → 3)-beta-D-glucan) (Lee et al. , 2005; Cho et al. , 2011), which indicated that both determination methods (e.g., sensitivity, working principle) as well as particle…”
Self-citationElastomeric, Half-Facepiece, Air-Purifying Respirator Performance in a Lead Battery Plant
Janssen, L., & McCullough, N. V. (2009) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620903373537 · Cited by 11
“( 24 , 25 , 26 ) If this were true, WPFs would be expected to correlate positively with increasing particle size.”
Davidson, C. S., Green, C. F., Panlilio, A. L., Jensen, P. A., Stover, B. H., Roselle, G. A., Gibbs, S. G., & Scarpino, P. V. (2010) · Indoor and Built Environment · doi:10.1177/1420326x10378805 · Cited by 7
Sekoguchi, S., Ando, H., Ikegami, K., Yoshitake, H., Baba, H., & Ogami, A. (2022) · Journal of UOEH · doi:10.7888/juoeh.44.15 · Cited by 5
Jachowicz, A., Majchrzycka, K., Szulc, J., Okrasa, M., & Gutarowska, B. (2019) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph16162819 · Cited by 6
“Therefore, authors claim N95 filtering facepiece respirators seem inadequate against microorganisms in agricultural working environments [15,16].”
BackgroundHypertonic Saline Nasal Rinse Intervention: Immunomodulatory Effects in Dairy Workers
Erlandson, G., Magzamen, S. L., Sharp, J. L., Seidel, J., Poole, J. A., Bradford, M., & Schaeffer, J. W. (2024) · Journal of Agromedicine · doi:10.1080/1059924x.2024.2416425 · Cited by 4
“6,29,30 Through guidance from the High Plains Intermountain Center for Agricultural Health and Safety (HICAHS) Advisory Board, we identified a low-cost intervention with the potential to improve dairy worker respiratory outcomes.”
Influence of wearing masks on exhaled air aerodynamics
Kerl, J., Gena, A. W., Alsaad, H., Voelker, C., & Dellweg, D. (2022) · Journal of Medical Engineering & Technology · doi:10.1080/03091902.2022.2026507 · Cited by 5
Lee, S.-A., Liao, C.-H., & Lin, T.-Y. (2018) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2017.08.0285 · Cited by 3
“The design concept was based on our previously developed personal sampling system, which had been used to evaluate respirator protection against airborne dust and microorganisms in the laboratory and in agricultural farms (Lee et al. , 2004, 2005a, b).”
InfluentialSelf-citationErlandson, G., Magzamen, S. L., Sharp, J. L., Mitra, S., Jones, K. L., Poole, J. A., Bradford, M., Nonnenmann, M. W., Reynolds, S. J., & Schaeffer, J. W. (2022) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2022.2137297 · Cited by 3
“The dairy workforce in the U.S. is estimated to be >90% Hispanic/Latino with no prior experience on a farm; this population is considered immunologically naïve to these complex bioaerosols (Maloney and Grusenmeyer 2005; Jenkins et al. 2009; Douphrate et al. 2013; Schenker and Gunderson 2013).”
BackgroundNicas, M. (2024) · Annals of the New York Academy of Sciences · doi:10.1111/nyas.15136 · Cited by 3
Effective Personal Protective Equipment (PPE)
Brouwer, D., & HEMMEN, J. J. V. (2007) · Cited by 2
Utah Regional Differences in Respirator Use and Fit Testing among Pesticide Applicators
Pate, M. L., Beard, F. R., & Hall, K. (2017) · Journal of Agricultural Safety and Health · doi:10.13031/jash.11765 · Cited by 2
“Ensuring the health benefits associated with respirators should be maximized when agricultural workers know how to appropriately select a respirator type, identify face-seal leaks due to poor respirator fit, and perform appropriate maintenance (Lee et al., 2005; Sprince et al., 2000).”
BackgroundInfluentialCorrecting Coal Miner Respirator Total Inward Leakage Values for Respiratory Tract Deposition
Nicas, M. (2023) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxad016 · Cited by 2
Ferguson, D. D., Smith, T. C., Donham, K. J., & O’Shaughnessy, P. T. (2014) · Journal of Agricultural Safety and Health · doi:10.13031/jash.20.10450 · Cited by 2
Makowski, K. (2012) · Bezpieczeństwo Pracy : nauka i praktyka · Cited by 1
PPE Effectiveness in Agricultural Settings
Sutphen, A. (2013) · ResearchWorks at the University of Washington (University of Washington) · Cited by 1
Face-masks save us from SARS-CoV-2 transmissionPreprint
Bagheri, G., Thiede, B., Hejazi, B., Schlenczek, O., & Bodenschatz, E. (2021) · arXiv (Cornell University) · doi:10.48550/arxiv.2106.00375 · Cited by 2
Penetration through the staple punctures on five N95 respirator models
Medina, D. E. (2014) · Digital Commons - University of South Florida (University of South Florida)
Ferguson, D. D. (2012) · doi:10.17077/etd.q87vbt68 · Cited by 4
“* M= median, R= range Non-respirable (particles > 5 um) Respirable (particles < 5 um) Sampling Date Inside M (R) (particles/liter) Downwind M (R ) (particles/lite r) Inside M (R) (particles/liter) Downwind M (R) (particles/liter) 11/9/2010 278 (80-619) 2 (0-31) 720 (307-21250) 150 (0-15,679) 11/10/2010 325 (84-920) 2…”
Letter to the Editor: Comments on a Recent Protection Factor Study
Nelson, T. (2006) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620600755275
“( 1 ) The authors reported three results that are contrary to other research: (1) WPFs increased with increasing particle size, (2) WPFs were higher for dusts than for biological particles, and (3) the WPF results suggest the assigned protection factor (APF) of 10 is too high for FFR.”
Evaluation and Management of Work-Related Asthma
Lau, A. K., & Tarlo, S. M. (2019) · Respiratory medicine · doi:10.1007/978-3-030-20812-7_5
Schlünssen, V., Würtz, E. T., Hansen, M. R. H., Miller, M. R., Sigsgaard, T., & Omland, Ø. (2020) · European Respiratory Society eBooks · doi:10.1183/2312508x.10034419
Caretto, D. C. (2016) · Wiley eBooks · doi:10.1002/9781119276531.ch28
Geng, Y., Zhao, L., & Jepsen, S. D. (2022) · Biosystems Engineering · doi:10.1016/j.biosystemseng.2022.05.020 · Cited by 1
COVID-19 Preventive Measure: A Study on “MASK-A Boon or a Bane”
Amin, R., Dastidar, R. G., & Vaishali, K. (2022) · Interdisciplinary Perspectives on Infectious Diseases · doi:10.1155/2022/2253656
Yamamoto, N. (2023) · Elsevier eBooks · doi:10.1016/b978-0-12-824411-1.00001-6
Airway Diseases and Occupational Exposures in Poultry Industry Workers: A Comprehensive Review
Hutson, M., & Bailey, K. L. (2026) · Current Allergy and Asthma Reports · doi:10.1007/s11882-026-01289-y
“Filtering facepiece respirators (e.g., N95 masks) [95] are considered appropriate for use in poultry barns.”
Metadata
- Authors
- Lee, S.-A., Adhikari, A., Grinshpun, S. A., McKay, R., Shukla, R., Zeigler, H. L., & Reponen, T.
- Affiliations
- University of Cincinnati (US)
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2005-11
- Volume
- 2
- Issue
- 11
- Pages
- 577-585
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- OpenAlex
- W2140615562
- Cited by
- 73
- References
- 18
- Citations by year
- 2026: 1 · 2024: 2 · 2023: 4 · 2022: 5 · 2021: 4 · 2020: 2 · 2019: 4 · 2018: 1 · 2017: 5 · 2016: 4 · 2015: 1 · 2014: 3 · 2013: 8 · 2012: 7
- FWCI
- 12.07
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Occupational and Environmental Hygiene (publishedVersion)
- PubMed (publishedVersion)
- Funders
- University of Cincinnati
- National Institute for Occupational Safety and Health (R01 OH04085)
- Topics
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Physical Sciences › Environmental Science › Health, Toxicology and Mutagenesis › Indoor Air Quality and Microbial Exposure
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Keywords
- N95 respirators, workplace protection factor, airborne dust, bioaerosols, microorganisms, farms, fungi, bacteria, particle size, animal feeding, grain harvesting, lung deposition, dead space
- MeSH terms
- Agriculture, Air Microbiology, Air Pollutants, Occupational, Cladosporium, Dust, Filtration, Fungi, Humans, Materials Testing, Particle Size, Respiratory Protective Devices, Spores, Fungal, Occupational Exposure, Inhalation Exposure
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.