The Effect of Subject Characteristics and Respirator Features on Respirator Fit
The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Abstract
A recent study was conducted to compare five fit test methods for screening out poor-fitting N95 filtering-facepiece respirators. Eighteen models of NIOSH-certified, N95 filtering-facepiece respirators were used to assess the fit test methods by using a simulated workplace protection factor (SWPF) test. The purpose of this companion study was to investigate the effect of subject characteristics (gender and face dimensions) and respirator features on respirator fit. The respirator features studied were design style (folding and cup style) and number of sizes available (one size fits all, two sizes, and three sizes). Thirty-three subjects participated in this study. Each was measured for 12 face dimensions using traditional calipers and tape. From this group, 25 subjects with face size categories 1 to 10 tested each respirator. The SWPF test protocol entailed using the PortaCount Plus to determine a SWPF based on total penetration (face-seal leakage plus filter penetration) while the subject performed six simulated workplace movements. Six tests were conducted for each subject/respirator model combination with redonning between tests. The respirator design style (folding style and cup style) did not have a significant effect on respirator fit in this study. The number of respirator sizes available for a model had significant impact on respirator fit on the panel for cup-style respirators with one and two sizes available. There was no significant difference in the geometric mean fit factor between male and female subjects for 16 of the 18 respirator models. Subsets of one to six face dimensions were found to be significantly correlated with SWPFs (p < 0.05) in 16 of the 33 respirator model/respirator size combinations. Bigonial breadth, face width, face length, and nose protrusion appeared the most in subsets (five or six) of face dimensions and their multiple linear regression coefficients were significantly different from zero (p < 0.05). Lip length was found in only one subset. The use of face length and lip length as the criteria to define the current half-facepiece respirator fit test panel may need to be reconsidered when revising the panel. Based on the findings from this and previous studies, face length and face width are recommended measurements that should be used for defining the panel for half-facepiece respirators.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“The N95 is NIOSHapproved with 95% filtration efficiency. 43”
From Assessment of N95 and K95 respirator decontamination: fiber integrity, filtration efficiency, and dipole charge density (2020) · cites this paper as [43]
Citations
Cites
Applied Linear Regression Models
(1997) · Technometrics · doi:10.1080/00401706.1997.10485142 · Cited by 4,615
Head-and-Face Anthropometric Survey of U.S. Respirator Users
Zhuang, Z., & Bradtmiller, B. (2005) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620500324727 · Cited by 195 · cited 2×
“respirator users was recently completed by NIOSH.(17) The LANL full-facepiece panel excluded 15.”
BackgroundSelf-citationFitting Characteristics of Eighteen N95 Filtering-Facepiece Respirators
Coffey, C. C., Lawrence, R. B., Campbell, D. L., Zhuang, Z., Calvert, C. A., & Jensen, P. A. (2004) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620490433799 · Cited by 119 · cited 1×
“(19) The fit of 18 models of NIOSH-certified, N95 filtering-facepiece respirators was assessed by using a simulated workplace protection factor (SWPF) test.(20)”
MethodSelf-citationOESTENSTAD, R. K., DILLION, H. K., & PERKINS, L. L. (1990) · American Industrial Hygiene Association Journal · doi:10.1080/15298669091369664 · Cited by 83 · cited 1×
“Oestenstad et al.(12) studied the location and shape of faceseal leak sites for a single brand of half-mask respirator worn by 73 subjects, and compared those observations to facial measurements, subject gender, and quantitative fit factor.”
Background(2001) · John Wiley & Sons, Inc. eBooks · doi:10.1002/0471125326 · Cited by 76
Comparison of Five Methods for Fit-Testing N95 Filtering-Facepiece Respirators
Coffey, C. C., Lawrence, R. B., Zhuang, Z., Campbell, D. L., Jensen, P. A., & Myers, W. R. (2002) · Applied Occupational and Environmental Hygiene · doi:10.1080/10473220290107002 · Cited by 70
Self-citationRespirator protection factors: Part I — Development of an anthropometric test panel
HACK, A. L., & McConville, J. T. (1978) · American Industrial Hygiene Association Journal · doi:10.1080/0002889778507897 · Cited by 62 · cited 3×
“(19) The respirator sizes for the corresponding face and lip length were based on recommendations by the Los Alamos National Laboratory.(8)”
BackgroundMethodInfluentialAnthropometry of air force women
(1973) · Applied Ergonomics · doi:10.1016/0003-6870(73)90105-1 · Cited by 56 · cited 2×
“There was no significant difference in the GM SWPF between cup style (25) and folding style (22) for combined data from all number of respirator sizes available (p > 0.”
BackgroundMethodFacial Dimensions and Predictors of Fit for Half-Mask Respirators in Koreans
Han, D.-H., & Choi, K.-L. (2003) · AIHA Journal · doi:10.1080/15428110308984877 · Cited by 53 · cited 2×
“Since the correlation coefficients are similar to those reported by Han and Choi,(16) they are not reported in this article.”
BackgroundResultAN ASSESSMENT OF CRITICAL ANTHROPOMETRIC DIMENSIONS FOR PREDICTING THE FIT OF A HALF-MASK RESPIRATOR
Oestenstad, R. K., & Perkins, L. L. (1992) · American Industrial Hygiene Association Journal · doi:10.1080/15298669291360283 · Cited by 50 · cited 4×
“(10−16) Oestenstad and Perkins(12−14) concluded that mentonsubnasale (lower face) length alone was consistently indicated as being correlated or associated with the fit of each brand of half-facepiece respirator rather than face length and lip length.”
BackgroundInfluential
Research works printed but not linked: 4
- Standards Australia and Standards New Zealand, 1994, S/NZS 1716:1994 Respiratory Protective Devices [Standard].
- European Committee for Standardization, 1989, EN 140 Half-Masks and Quarter-Masks; Requirements, Testing, Marking.
- Oestenstad R. K., 1994, Factors Affecting Respirator Leak Sites and Shapes.
- Zhuang Z., 2004, J. Int. Soc. Respir. Prot, 21, 83
Cited by
Langrish, J. P., Mills, N. L., Chan, J. K., Leseman, D. L., Aitken, R. J., Fokkens, P. H., Cassee, F. R., Li, J., Donaldson, K., Newby, D. E., et al. (2009) · Particle and Fibre Toxicology · doi:10.1186/1743-8977-6-8 · Cited by 237
“Leaks around the facemask will lead to a reduction in the efficacy of particle filtration [37,38] and therefore our predicted exposures during application of the facemask are likely to be an underestimate.”
BackgroundLee, S.-A., Grinshpun, S. A., & Reponen, T. (2008) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men005 · Cited by 235
“The SWPF has been used in several recent studies for characterizing respirator performance (e.g. Coffey et al., 2004; Zhuang et al., 2005; Coffey et al., 2006; Lawrence et al., 2006; Duling et al., 2007).”
MethodResultInfluentialFacial Anthropometric Differences among Gender, Ethnicity, and Age Groups
(2010) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/meq007 · Cited by 209
“The panel for halffacepiece respirators is defined by face length and lip length (bicheilion breadth) (Zhuang et al., 2005).”
BackgroundInfluentialSelf-citationNew respirator fit test panels representing the current U.S. civilian work force
Zhuang, Z., Bradtmiller, B., & Shaffer, R. E. (2007) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620701497538 · Cited by 187
“The variation of respirator fit in each cell has not been investigated in the past; however, at least one study found that a single size facepiece does not fit the population well.(18)”
BackgroundMethodResultSelf-citationLee, S.-A., Hwang, D.-C., Li, H.-Y., Tsai, C.-F., Chen, C.-W., & Chen, J.-K. (2016) · Journal of Healthcare Engineering · doi:10.1155/2016/8572493 · Cited by 134
“The assessment of respiratory protection has frequently been conducted using the heads of mannequins [18] instead of human subjects, disregarding that human factors—such as facial dimensions [19] and breathing patterns and flow [13]—may interfere with protection provided by respirators.”
BackgroundYim, W., Cheng, D., Patel, S., Kui, R., Meng, Y. S., & Jokerst, J. V. (2020) · medRxiv · doi:10.1101/2020.07.07.20148551 · Cited by 104
Head-and-Face Anthropometric Survey of Chinese Workers
Du, L., Zhuang, Z., Guan, H., Xing, J., Tang, X., Wang, L., Wang, Z., Wang, H., Liu, Y., Su, W., et al. (2008) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men056 · Cited by 75
“In addition to the dimensions noted in this study, other dimensions have been found to impact respirator fit: nose breadth, minimum frontal breadth, interpupillary distance, head breadth and subnasale–sellion length (Zhuang et al., 2005).”
BackgroundSelf-citationMcMahon, E., Wada, K., & Dufresne, A. (2008) · American Journal of Infection Control · doi:10.1016/j.ajic.2007.10.014 · Cited by 74
“Facial characteristics, including face length and width, have been identified as important factors in correctly fitting a respirator.(9) Understanding the factors that can affect the fit of respirators will be helpful when implementing a respiratory protection program.”
BackgroundKim, J., Wu, T., Powell, J. B., & Roberge, R. J. (2015) · American Journal of Infection Control · doi:10.1016/j.ajic.2015.08.027 · Cited by 72
“25 Some of the subjects who failed a fit test (ie, score <100) nonetheless still attained a score (!10) that correlated with the OSHA-assigned protection factor of 10 for FFRs (the workplace level of respiratory protection that a respirator or class of respirators is expected to provide to employees when the employer…”
BackgroundLei, Z., Yang, J., & Zhuang, Z. (2011) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2011.635130 · Cited by 74
Self-citationBhattacharjee, S., Bahl, P., Chughtai, A. A., & MacIntyre, C. R. (2020) · BMJ Open Respiratory Research · doi:10.1136/bmjresp-2020-000698 · Cited by 70
Yang, L., Shen, H., & WU, G. (2007) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/mem005 · Cited by 60
“…facial dimensions and respirator fit have demonstrated that face width (BIZBDTH) and face length (MENSELLH) should also be considered for defining half-mask RFTPs, not just full-facepiece panels (Liau et al., 1982; Gross and Horstman, 1990; Oestenstad and Perkins, 1992; Zhuang et al., 2005).”
BackgroundLin, Y.-C., & Chen, C. (2017) · PLoS ONE · doi:10.1371/journal.pone.0188638 · Cited by 60
New Respirator Fit Test Panels Representing the Current Chinese Civilian Workers
Chen, W., Zhuang, Z., Benson, S. M., Du, L., Yu, D., Landsittel, D. P., Wang, L., Viscusi, D. J., & Shaffer, R. E. (2009) · The Annals of Occupational Hygiene · doi:10.1093/annhyg/men089 · Cited by 53
Self-citationCorrelation Between Respirator Fit and Respirator Fit Test Panel Cells by Respirator Size
Zhuang, Z., Groce, D. W., Ahlers, H., Iskander, W. H., Landsittel, D. P., Guffey, S. E., Benson, S. M., Viscusi, D. J., & Shaffer, R. E. (2008) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620802293810 · Cited by 46
Self-citationOestenstad, R. K., Kimbrough, L. J., & Beasley, T. M. (2007) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459620701709619 · Cited by 45
“These findings support those of Zhuang et al.(7) and Oestenstad and Perkins.”
BackgroundMethodResultInfluentialFitting Characteristics of N95 Filtering-Facepiece Respirators Used Widely in China
Yu, Y.-Y., Jiang, L.-M., Zhuang, Z., Liu, Y., Wang, X., Liu, J., Ming-na, Y., & Chen, W. (2014) · PLoS ONE · doi:10.1371/journal.pone.0085299 · Cited by 50
“Face length and face width are main indexes used for defining the panel for half-facepiece respirators [26].”
Self-citationChopra, J., Abiakam, N., Kim, H., Metcalf, C., Worsley, P. R., & Cheong, Y. C. (2021) · BMJ Global Health · doi:10.1136/bmjgh-2021-005537 · Cited by 47
“54 Once a successful fit test was obtained other models were not tested.”
Provenzano, D., Rao, Y. J., Mitic, K., Obaid, S. N., Pierce, D., Huckenpahler, J., Berger, J., Goyal, S., & Loew, M. H. (2020) · Preprints.org · doi:10.20944/preprints202003.0444.v1 · Cited by 41
Rengasamy, S., Zhuang, Z., Niezgoda, G., Walbert, G. F., Lawrence, R., Boutin, B. K., Hudnall, J. B., Monaghan, W. P., Bergman, M. S., Miller, C., et al. (2018) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2018.1479064 · Cited by 43
Self-citationNiezgoda, G., Kim, J.-H., Roberge, R. J., & Benson, S. M. (2013) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.801246 · Cited by 43
“(18) One prior investigation found that respirator design (4 flat fold vs. 14 cup –shaped N95 FFRs) was not a significant factor in respirator fit, (18) whereas another study noted one model of a flat fold respirator was associated with both the highest fit factor pass rate and level of comfort…”
Manganyi, J., Wilson, K. S., & Rees, D. (2017) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxx077 · Cited by 36
“Men achieved a significantly higher proportion of passes than women, a finding consistent with other studies (Han, 2000; Zhuang et al., 2007b), probably because medium respirators fit men better than women.”
BackgroundResultRespirator fit of a medium mask on a group of South Africans: a cross-sectional study
Spies, A., Wilson, K. S., & Ferrie, R. T. (2011) · Environmental Health · doi:10.1186/1476-069x-10-17 · Cited by 34
“respirator fit have mostly been carried out on Caucasian and/or male subjects with little attention paid to other races or females [5].”
BackgroundTraditional and 3D scan extracted measurements of the heads and faces of Dutch children
Goto, L., Lee, W., Molenbroek, J. F. M., Cabo, A. J., & Goossens, R. (2019) · International Journal of Industrial Ergonomics · doi:10.1016/j.ergon.2019.102828 · Cited by 30
Reliability and Accuracy of 2D Photogrammetry: A Comparison With Direct Measurement
Lim, Y. C., Shakor, A. S. A., & Shaharudin, R. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2021.813058 · Cited by 30
“It is widely applied in orthodontic and reconstructive surgery, forensics, and the design of helmets, masks, eyeglasses and respirators (1).”
BackgroundBiological monitoring of benzene exposure during maintenance work in crude oil cargo tanks
Kirkeleit, J., Riise, T., Bråtveit, M., Pekari, K., Mikkola, J., & Moen, B. E. (2006) · Chemico-Biological Interactions · doi:10.1016/j.cbi.2006.08.017 · Cited by 27
Do Various Respirator Models Fit the Workers in the Norwegian Smelting Industry?
Føreland, S., Robertsen, O., & Hegseth, M. N. (2019) · Safety and Health at Work · doi:10.1016/j.shaw.2019.06.004 · Cited by 26
Zhuang, Z., Bergman, M. S., Lei, Z., Niezgoda, G., & Shaffer, R. E. (2017) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2017.1296233 · Cited by 25
Self-citationGomersall, C. D., Loo, S., Joynt, G. M., & Taylor, B. L. (2007) · Current Opinion in Critical Care · doi:10.1097/mcc.0b013e3282f1bafd · Cited by 25
Development of a Virtual Fit Analysis Method for an Ergonomic Design of Pilot Oxygen Mask
Lee, W., Jung, D., Park, S., Kim, H.-E., & You, H. (2021) · Applied Sciences · doi:10.3390/app11125332 · Cited by 19
Morishima, M., & Kishida, K. (2018) · Work · doi:10.3233/wor-182801 · Cited by 21
Study of contact characteristics between a respirator and a headform
Cai, M., Shen, S., Li, H., Zhang, X., & Ma, Y. (2015) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2015.1116699 · Cited by 17
Fakherpour, A., Jahangiri, M., Seif, M., Charkhand, H., Abbaspour, S., & Floyd, E. L. (2021) · Journal of Environmental Health Science and Engineering · doi:10.1007/s40201-021-00648-3 · Cited by 17
“However, another study demonstrated no significant differences between the cup-shaped and flat-fold respirators by the FFs [74, 75].”
ResultHead and face anthropometric study for respirators in the multi-ethnic Asian population of Malaysia
Lim, Y. C., Shakor, A. S. A., Mohamad, N., Pahrol, M. A., Ismail, R., Chong, Z. L., Mutalip, M. H. A., Omar, M. A., Danaee, M., Wan, G. T., et al. (2022) · Frontiers in Public Health · doi:10.3389/fpubh.2022.972249 · Cited by 16
“The study revealed that the 10 dimensions were associated with respirator fit and leakage and predicted well the remaining head and facial dimensions (9).”
BackgroundDetermining Sample Size and a Passing Criterion for Respirator Fit-Test Panels
Landsittel, D. P., Zhuang, Z., Newcomb, W. E., & Ann, R. B. (2013) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2013.843780 · Cited by 16
Self-citationAu, S. S. W., Gomersall, C. D., Leung, P., & Li, P. T. Y. (2010) · Journal of Hospital Infection · doi:10.1016/j.jhin.2010.01.017 · Cited by 16
“5 It may be possible to identify a small number of masks most likely to fit the population of at-risk staff by testing a larger range of masks on a sample of about 40 staff members.”
Milosevic, M., Biswas, R. K., Innes, L., Ng, M., Darendeliler, A. M., Wong, A., & Denney‐Wilson, E. (2021) · American Journal of Infection Control · doi:10.1016/j.ajic.2021.12.016 · Cited by 16
“Facial anthropometric dimensions have an important influence on FFR fit(15) and these measurements can vary significantly between males and females.(21,22) In the U.”
Analysis of the fitting of patterns of hygiene masks for the closed mouth
Morishima, M., Shimizu, Y., Fujiyama, T., & Mitsuno, T. T. (2014) · Textile Research Journal · doi:10.1177/0040517514557311 · Cited by 14
Zhuang, Z., Benson, S. M., Lynch, S., Palmiero, A., & Roberge, R. J. (2011) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2011.627294 · Cited by 14
“Zhuang et al.(6) found significant correlations among fit and two facial dimensions: bigonial breadth and nose protrusion.”
BackgroundSelf-citationAnalysis of fit pattern of a hygiene mask for an opened mouth
Morishima, M., Fujiyama, T., Shimizu, Y., & Mitsuno, T. T. (2015) · Textile Research Journal · doi:10.1177/0040517515591780 · Cited by 12
“However, there are few relevant studies testing mask fitting that take facial movements into account.(9,10) For instance, when a two-dimensional (2D) gauze mask-wearer pronounces vowels, the angular difference between the mask sheet and the nose-wing increases.”
BackgroundSalvarzi, E., Choobineh, A., Jahangiri, M., & Keshavarzi, S. (2018) · International Journal of Occupational Safety and Ergonomics · doi:10.1080/10803548.2018.1433578 · Cited by 12
Qualitative fitting characteristics of filtering face-piece respirators on Iranian people
Fakherpour, A., Jahangiri, M., & Seif, M. (2020) · Journal of Environmental Health Science and Engineering · doi:10.1007/s40201-020-00484-x · Cited by 13
“found that the respirator style had no significant effect on respirator fit [36].”
BackgroundMethodInfluentialChakladar, A., Jones, C. G., Siu, J., Hassan-Ibrahim, M. O., & Khan, M. A. (2021) · American Journal of Infection Control · doi:10.1016/j.ajic.2021.02.006 · Cited by 12
Soto, J., Linsley, C. S., Song, Y., Chen, B., Fang, J., Neyyan, J., Davila, R., Lee, B. S., Wu, B. M., & Li, S. (2023) · Nanomaterials · doi:10.3390/nano13172455 · Cited by 9
“Looking at face shape data of a large population, they concluded the most important facial dimensions to consider in design are bigonial breadth, bizygomatic breadth, menton–sellion length, and nose protrusion [28,29].”
BackgroundComparison of two quantitative fit-test methods using N95 filtering facepiece respirators
Sietsema, M., & Brosseau, L. M. (2016) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2016.1159690 · Cited by 9
“These measurements were used to determine each subject’s cell in the NIOSH bivariate fit test panel.[5]”
MethodPerformance Evaluation of Full Facepiece Respirators with Cartridges
Lee, S.-A., Chen, Y.-L., Hwang, D.-C., Wu, C.-C., & Chen, J.-K. (2017) · Aerosol and Air Quality Research · doi:10.4209/aaqr.2016.11.0485 · Cited by 8
“Although face features such as bigonial breadth, face width, face length and nose protrusion might affect N95 respirator fit (Zhuang et al. , 2005), since we used full facepiece respirators instead, the respirator almost covered that entire face and the contact surface between the respirator and…”
The effect of N95 designs on respirator fit and its associations with gender and facial dimensions
Hasni, N. A. K., Ismail, R., Robat, R. M., Mohamad, N., Suib, F. A., Pahrol, M. A., Mahmud, H., Osman, B., Lim, Y. C., Seman, Z., et al. (2023) · PLoS ONE · doi:10.1371/journal.pone.0288105 · Cited by 14
“This is in contrast with studies by Zhuang et al. and Oestenstad et al., whereby all twelve measured facial dimensions have significant regression coefficient with fit factors [17, 48].”
ResultChan, J. K., Yep, K. H., Magarey, S., Keon-Cohen, Z., & Acheson, M. (2021) · COVID · doi:10.3390/covid1010007 · Cited by 8
Inward Leakage Variability between Respirator Fit Test Panels – Part I. Deterministic Approach
Zhuang, Z., Liu, Y., Coffey, C. C., Miller, C., & Szalajda, J. V. (2015) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2015.1047025 · Cited by 7
Self-citationDavidson, C. S., Green, C. F., Panlilio, A. L., Jensen, P. A., Stover, B. H., Roselle, G. A., Gibbs, S. G., & Scarpino, P. V. (2010) · Indoor and Built Environment · doi:10.1177/1420326x10378805 · Cited by 7
NIOSH-NPPTL, 6. C. M. R., & Zhuang, Z. (2015) · Journal of Nanotechnology and Materials Science · doi:10.15436/2377-1372.15.015 · Cited by 8
Self-citationYu, M., Griffin, L., Durfee, W. K., & Arnold, S. F. (2024) · Annals of Work Exposures and Health · doi:10.1093/annweh/wxae005 · Cited by 8
Yang, L., Wei, R., & Shen, H. (2016) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2016.1207778 · Cited by 6
“[15,16] National Institute for Occupational Safety and Health (NIOSH) suggested a new bivariate fit test panel based on the bivariate distribution of face length and face width[14] because the two dimensions had significant correlation with fit in six of the eight studies for half-facepiece respirators.[17] Although t…”
BackgroundMethodKumar, A., Subramanian, V., Shailesh, J., & Venkatraman, B. (2022) · Journal of Industrial Textiles · doi:10.1177/15280837221090663 · Cited by 8
“The NIOSHcertified N95 mask could filter out all particles, including bacteria and viruses, more than 95% for MPPS.(20,27,28) [21, 28, 29].”
BackgroundInfluentialIntra-rater and inter-rater reliability of 3D facial measurements
Hobbs-Murphy, K., Olmedo-Nockideneh, I., Brazile, W. J., Morris, K. D., & Rosecrance, J. C. (2024) · Applied Ergonomics · doi:10.1016/j.apergo.2023.104218 · Cited by 5
Computer-Aided Customized Shape Design of an N95 Filtering Facepiece Respirator
Lei, Z., & Yang, J. (2013) · ASME International Design Engineering Technical Conferences and Computers and Information in Engineering Conference (IDETC/CIE) · doi:10.1115/detc2013-13251 · Cited by 5
“Studies on N95 FFR have been mainly focusing on experimental methods of evaluating existing N95 FFR designs [1-3].”
MethodJohnson, A. T., Koh, F. C., Scott, W. H., & Rehak, T. E. (2011) · Journal of Environmental and Public Health · doi:10.1155/2011/402148 · Cited by 4
“Reports have been published relating facial measurements of wearers to respirator fit [13].”
BackgroundInward leakage variability between respirator fit test panels – Part II. Probabilistic approach
Liu, Y., Zhuang, Z., Coffey, C. C., Rengasamy, S., & Niezgoda, G. (2016) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2016.1161198 · Cited by 4
Self-citationA Method for Generation of a Sizing System and Representative Models for a Facial Mask Design
Lee, W., Lee, B., Yang, X., & You, H. (2022) · Applied Sciences · doi:10.3390/app122312387 · Cited by 4
Fu, L., Guo, J., Zhang, Y., Jing, X., Lu, L., Wang, Y., Jiang, R., & Liu, L. (2024) · Building Simulation · doi:10.1007/s12273-024-1144-3 · Cited by 4
“The number of subjects was chosen according to NIOSH bivariate panel (Zhuang et al. 2007) and Chinese bivariate panel (Chen et al. 2009).”
InfluentialGakhal, M., Bakshi, A., Gu, M., & Khambay, B. (2024) · Scientific Reports · doi:10.1038/s41598-024-80001-4 · Cited by 4
Wangsan, K., Sapbamrer, R., Sirikul, W., Kiratipaisarl, W., Ongprasert, K., Assavanopakun, P., Surawattanasakul, V., Kitro, A., Panumasvivat, J., & Wongcharoen, A. (2025) · Frontiers in Public Health · doi:10.3389/fpubh.2025.1561571 · Cited by 6
“However, other studies suggest that dimensions such as face length and lip length may be more relevant for half-face respirators (12).”
Performance of a Novel Non–Fit-Tested HEPA Filtering Face Mask
Hui, C. Y. T., Leung, C. C. H., & Gomersall, C. D. (2017) · Infection Control and Hospital Epidemiology · doi:10.1017/ice.2017.105 · Cited by 4
“Facial characteristics may vary between racial groups, and our results may not be replicated in other groups.(9) Finally, the study was unblinded; however, it was mainly based on objective parameters.”
ResultHuman head modeling and applications
Yang, J., & Lei, Z. (2019) · Elsevier eBooks · doi:10.1016/b978-0-12-816713-7.00018-0 · Cited by 4
Fakherpour, A., Jahangiri, M., & Banaee, S. (2021) · Industrial Health · doi:10.2486/indhealth.2020-0199 · Cited by 4
Utilization of a mask fitter or micropore tape to improve the fit of a surgical mask
Youcharoen, K., Taosiri, P., Muangthong, P., Poenateetai, A., Sombuntham, N., & Dhanesuan, N. (2022) · Journal of Oral Science · doi:10.2334/josnusd.22-0162 · Cited by 4
Respiratory Protective Equipment
Birkner, J. S., & Colton, C. E. (2011) · Wiley eBooks · doi:10.1002/0471435139.hyg032.pub2 · Cited by 4
Craniometric determinants of the fitted filtration efficiency of disposable masks
Griffin, J. S., Mcinroe, E. M., Pennington, E. R., Steinhardt, W., Chen, H., Prince, S. E., & Samet, J. M. (2024) · Frontiers in Public Health · doi:10.3389/fpubh.2024.1444411 · Cited by 3
“Previous studies have described the relationship between the FFE of respirators and craniofacial morphology and found that protection is a product of the interaction between the respirator and the wearer’s own facial features (9–16).”
BackgroundInfluentialRao, L., Lu, J., Wang, S., Li, H., & Han, W. (2025) · Journal of Hospital Infection · doi:10.1016/j.jhin.2025.10.001 · Cited by 3
A combined imaging, deformation and registration methodology for predicting respirator fitting
Caggiari, S., Keenan, B. E., Bader, D. L., Mavrogordato, M., Rankin, K. E., Evans, S. L., & Worsley, P. R. (2022) · PLoS ONE · doi:10.1371/journal.pone.0277570 · Cited by 3
Bray, C., & Vanberkel, P. T. (2023) · Health Policy · doi:10.1016/j.healthpol.2023.104857 · Cited by 3
“A study conducted in 2005 found that face length and lip length were not sufficient measures for N95 respirator fit testing [18].”
Gibbs, J. L., Sheridan, C., Sullivan, D., Rautiainen, R. H., Nonnenmann, M. W., & Wyatt, T. A. (2023) · American Journal of Industrial Medicine · doi:10.1002/ajim.23515 · Cited by 3
Evaluation of Rigidity of Surgical N95 Respirators Using a Manikin-System: A Pilot Study
Rengasamy, S., & Niezgoda, G. (2019) · Journal of the International Society for Respiratory Protection · doi:10.66828/001c.166465 · Cited by 3
“Many surgical N95 respirators have a rigid structural design (cup-shaped or trifold) that prevents the inner surface of the respirator from coming in contact with the user’s face (Coffey et al., 2004; Niezgoda, Kim, Roberge, & Benson, 2013; Zhuang, Coffey, & Ann, 2005).”
Silva, E. C., Castellucci, H. I., Valenzuela, S., Rodríguez, A. A., Escanilla, D. E., Caroca, L. A., Molenbroek, J. F. M., Huysmans, T., & Viviani, C. (2025) · Work · doi:10.1177/10519815241303337 · Cited by 2
Surgical helmets can be converted into efficient disinfectable powered air-purifying respirators
Temmesfeld, M. J., Gorzkowska-Sobas, A. A., Hedlund, K., Øyen, M. Ø., Kanten, L., Grant, P., & Jakobsen, R. B. (2021) · American Journal of Infection Control · doi:10.1016/j.ajic.2021.12.002 · Cited by 2
Zhu, J., Jiang, Q., Ye, Y., He, X., Shao, J., Li, X., Zhao, X., Xu, H., & Hu, Q. (2023) · Safety and Health at Work · doi:10.1016/j.shaw.2023.10.009 · Cited by 2
Fakherpour, A., Jahangiri, M., & Haghighi, A. (2025) · BMC Public Health · doi:10.1186/s12889-025-24867-7 · Cited by 1
“…such as materials (nanofiber, polypropylene spun bond, polypropylene melt blown, cloth mask, etc.) [77], brands, models, styles (e.g., flat-fold, cup-style, duckbill), sizes (e.g., two-, three-, five-size system) [78] and wear-ers’ characteristics (face size, face shape, gender, age, race) [52].”
McGuinness, K. L., Hinks, I., Westcott, K. E., & Gheewala, S. H. (2020) · Journal of Global Health Reports · doi:10.29392/001c.14598 · Cited by 1
Which alternative well-fit masks can be used in medical procedures?
Thapthim-on, M., Chaiear, N., & Mitsungnern, T. (2023) · Journal of Infection and Public Health · doi:10.1016/j.jiph.2023.11.023 · Cited by 3
Jahangiri, M., Fakherpour, A., & Yousefinejad, S. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95316-0.00004-9 · Cited by 1
Yu, M., & Griffin, L. (2024) · SSRN Electronic Journal · doi:10.2139/ssrn.4837907 · Cited by 2
SARS, Bird Flu and other scares — epidemic and pandemic preparedness in intensive care
Joynt, G. M., & Gomersall, C. D. (2008) · Southern African Journal of Anaesthesia and Analgesia · doi:10.1080/22201173.2008.10872526 · Cited by 1
Groce, D. W. (2007) · The Research Repository @ WVU (West Virginia University) · doi:10.33915/etd.8960
Simulation-based assessment for N95 filtering facepiece respirator
Lei, Z. (2014) · ThinkTech (Texas Tech University)
3D PRINTING OF A LOWELL MAKES MASK IN PLA
Elmoutawakkil, N., Alae-Eddine, S., Dalal, E., Hacib, N., & Bellemkhannate, S. (2021) · Medical Science of Ukraine (MSU) · doi:10.32345/2664-4738.3.2021.12
Dickson, E. F. G. (2012) · Wiley eBooks · doi:10.1002/9781118422991.refs
Short: A data-driven respirator fit test model via human speech signal
Chen, J., Zhang, Z., Zhao, S., Fang, S., Peters, T. M., Floyd, E. L., & Cai, C. (2023) · Smart Health · doi:10.1016/j.smhl.2023.100400
Filtering facepiece respirator use among farm youth in the US: A review
Gibbs, J. L., Vollmer, B., Sheridan, C., Pinkerton, K. E., Anthony, R. T., Holm, S. M., Karr, C. J., Proctor, A., & Swenson, A. V. R. (2026) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2025.2589137
“…are predominantly organized for adult occupational settings, leaving a critical gap in evidence-based guidance for youth/pediatric FFR use (Part 84—Approval of Respiratory Protective Devices 1995; Zhuang et al. 2005, 2007; Zhuang and Bradtmiller 2005; ASTM International 2021, 2022; NIOSH 2024).”
Fit testing of N95 respirators: A pilot study on respirator design and demographic factors
Niu, X., Yermakov, M. V., Grinshpun, S. A., & Wang, J. J. (2026) · Journal of Occupational and Environmental Hygiene · doi:10.1080/15459624.2026.2650644
“…a critical role in determining respirator fit, and demographic patterns in facial features may inform the development of more inclusive respirator design (Zhuang et al. 2005; Yang et al. 2007; Chen et al. 2009; Zhuang et al. 2010; Chopra et al. 2021; Caggiari et al. 2022; Chapman et al. 2023).”
InfluentialEighteen-Year Trends in Respirator Program Compliance: A Nationwide OSHA Enforcement Analysis
Pilgreen, J. (2026) · Journal of the International Society for Respiratory Protection · doi:10.66828/001c.164538
Gx, H., Li, L., 樊茹, (7081), W. L., Sheng, Z. J., & Zhang, W. H. (2026) · Frontiers in Public Health · doi:10.3389/fpubh.2026.1911331
“These population-specific differences may influence respirator fit performance and limit the direct generalizability of fit data derived from Western populations, supporting the need for region-specific respirator design and fit-test standards (24, 25).”
Chan, W.-Y., Ng, S.-P., Leung, S.-H. M., Yick, K., Loh, A. W.-K., Ng, S.-Y., & Lam, K. C. (2026) · Applied Sciences · doi:10.3390/app16168197
Lim, Y. C., Shakor, A. S. A., & Shaharudin, R. (2022) · doi:10.3389/fpubh.2021.813058.s003
Metadata
- Authors
- Zhuang, Z., Coffey, C. C., & Ann, R. B.
- Affiliations
- National Institute for Occupational Safety and Health (US)
- ORCID
- Zhuang, Ziqing
- Venue
- Journal of Occupational and Environmental Hygiene
- Publisher
- Informa UK Limited
- Published
- 2005-12
- Volume
- 2
- Issue
- 12
- Pages
- 641-649
- ISSN
- 1545-9624 (ISSN-L)
- 1545-9632
- OpenAlex
- W2161978306
- Cited by
- 93
- References
- 19
- Citations by year
- 2026: 5 · 2025: 4 · 2024: 7 · 2023: 7 · 2022: 6 · 2021: 9 · 2020: 5 · 2019: 4 · 2018: 3 · 2017: 5 · 2016: 4 · 2015: 5 · 2014: 3 · 2013: 3 · 2012: 1
- FWCI
- 2.94
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Journal of Occupational and Environmental Hygiene (publishedVersion)
- PubMed (publishedVersion)
- Topics
- Health Sciences › Medicine › Pulmonary and Respiratory Medicine › Infection Control and Ventilation
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Safety in Workplaces
- Health Sciences › Medicine › Public Health, Environmental and Occupational Health › Occupational Health and Performance
- Keywords
- N95 respirators, respirator fit, fit testing, face length, facial width, gender differences, lip length
- MeSH terms
- Adult, Equipment Design, Face, Female, Humans, Male, Materials Testing, Respiratory Protective Devices, Sex Factors, Reproducibility of Results, Workplace
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.