A review of invasive and non-invasive sensory feedback in upper limb prostheses
The DOI matches its Crossref record; 67 of the 68 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: The constant challenge to restore sensory feedback in prosthetic hands has provided several research solutions, but virtually none has reached clinical fruition. A prosthetic hand with sensory feedback that closely imitates an intact hand and provides a natural feeling may induce the prosthetic hand to be included in the body image and also reinforces the control of the prosthesis. Areas covered: This review presents non-invasive sensory feedback systems such as mechanotactile, vibrotactile, electrotactile and combinational systems which combine the modalities; multi-haptic feedback. Invasive sensory feedback has been tried less, because of the inherent risk, but it has successfully shown to restore some afferent channels. In this review, invasive methods are also discussed, both extraneural and intraneural electrodes, such as cuff electrodes and transverse intrafascicular multichannel electrodes. The focus of the review is on non-invasive methods of providing sensory feedback to upper-limb amputees. Expert commentary: Invoking embodiment has shown to be of importance for the control of prosthesis and acceptance by the prosthetic wearers. It is a challenge to provide conscious feedback to cover the lost sensibility of a hand, not be overwhelming and confusing for the user, and to integrate technology within the constraint of a wearable prosthesis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Rubber hands ‘feel’ touch that eyes see
Botvinick, M., & Cohen, J. (1998) · Nature · doi:10.1038/35784 · Cited by 4,410
Zagrean, L. (2014) · Acta Endocrinologica (Bucharest) · doi:10.4183/aeb.2014.529 · Cited by 1,909
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Stretchable silicon nanoribbon electronics for skin prosthesis
Kim, J., Lee, M., Shim, H. J., Ghaffari, R., Cho, H. R., Son, D., Jung, Y. H., Soh, M., Choi, C., Jung, S., et al. (2014) · Nature Communications · doi:10.1038/ncomms6747 · Cited by 1,435
Upper limb prosthesis use and abandonment: A survey of the last 25 years
Biddiss, E. A., & Chau, T. T. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600994581 · Cited by 1,111
The perception of phantom limbs. The D. O. Hebb lecture
Ramachandran, V. (1998) · Brain · doi:10.1093/brain/121.9.1603 · Cited by 1,064
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Literature Review on Needs of Upper Limb Prosthesis Users
Cordella, F., Ciancio, A. L., Sacchetti, R., Davalli, A., Cutti, A. G., Guglielmelli, E., & Zollo, L. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00209 · Cited by 752
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
Intracortical microstimulation of human somatosensory cortex
Flesher, S. N., Collinger, J. L., Foldes, S. T., Weiss, J. M., Downey, J. E., Tyler-Kabara, E. C., Bensmaia, S. J., Schwartz, A. B., Boninger, M. L., & Gaunt, R. A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf8083 · Cited by 704
Research works printed but not linked: 7
- Alessandro C, 2015, Biosystems & biorobotics, 225
- 10.1053/hanthe.2002.v15.01562 · doi:10.1053/hanthe.2002.v15.01562 · Paper page
- Purves D, 2012, Neuroscience
- Weber EH, 1978, E. H. Weber: the sense of touch
- Clemente F, 2015, IEEE Trans Neural Syst Rehabil Eng
- Desai VH, 2014, Conf Proc IEEE Eng Med Biol Soc, 2014, 1973
- Wodlinger B, 2014, J Neural Eng, 12, 0106011
Cited by
Items 101–192 of 192
Bruni, G., Marinelli, A., Bucchieri, A., Boccardo, N., Caserta, G., Domenico, D. D., Barresi, G., Florio, A., Canepa, M., Tessari, F., et al. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1078846 · Cited by 10
“…et al., 2019; Di Pino et al., 2020; Shehata et al., 2020; Raspopovic et al., 2021), allowing subjects to embody the device (Antfolk et al., 2013; Svensson et al., 2017; Raspopovic et al., 2021), hence, improving the compliance among the user, the prosthesis, and the grasped objects (Osborn et…”
BackgroundUneven Terrain Recognition Using Neuromorphic Haptic Feedback
Prasanna, S., D’Abbraccio, J., Filosa, M., Ferraro, D., Cesini, I., Spigler, G., Aliperta, A., Dell’Agnello, F., Davalli, A., Gruppioni, E., et al. (2023) · Sensors · doi:10.3390/s23094521 · Cited by 6
“In addition, their small form factor and low cost make them appealing for many commercial and daily-life applications [17,18].”
BackgroundKindel, J., Andreas, D., Hou, Z., Dwivedi, A., & Beckerle, P. (2024) · Multimodal Technologies and Interaction · doi:10.3390/mti8060044 · Cited by 7
“Due to its interference with electromyography signals [10], it is, however, less suitable as a feedback device for myoelectric prostheses, for instance.”
BackgroundCut wires: The Electrophysiology of Regenerated Tissue
Lowe, A. L., & Thakor, N. V. (2021) · Bioelectronic Medicine · doi:10.1186/s42234-021-00062-y · Cited by 6
Novel Wearable Tactile Feedback System for post-stroke Rehabilitation
Abbass, Y., Seminara, L., Saleh, M., & Valle, M. (2021) · IEEE Biomedical Circuits and Systems Conference (BioCAS) · doi:10.1109/biocas49922.2021.9645020 · Cited by 6
Mayer, R. M., Mohammadi, A., Tan, Y., Alıcı, G., Choong, P., & Oetomo, D. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1113009 · Cited by 9
“There are cases that osseointegration is not suited for people with upper-limb loss due to the lack of length or strength in the residual limb or the inherent surgical risks of the invasive technique (Schofield et al., 2014; Cordella et al., 2016; Farina and Amsüss, 2016; Svensson et al., 2017).”
BackgroundMethodHaptics: The Science of Touch As a Foundational Pathway to Precision Education and Assessment
Perrone, K. H., Abdelaal, A. E., Pugh, C. M., & Okamura, A. M. (2023) · Academic Medicine · doi:10.1097/acm.0000000000005607 · Cited by 6
“10,14,15 In medical education, haptic devices enhance realism in virtual reality and manikin simulations to improve learning and provide a way to objectively quantify performance for individualized feedback.”
BackgroundA Multi-modal Haptic Armband for Finger-Level Sensory Feedback from a Prosthetic Hand
Berkovic, A., Laganier, C., Chappell, D., Nanayakkara, T., Kormushev, P. S., Bello, F., & Rojas, N. (2022) · Lecture notes in computer science · doi:10.1007/978-3-031-06249-0_16 · Cited by 5
Barontini, F., Straaten, M. G. V., Catalano, M. G., Thoreson, A. R., Lopez, C., Lennon, R. J., Bianchi, M., Andrews, K. L., Santello, M., Bicchi, A., et al. (2023) · PLoS ONE · doi:10.1371/journal.pone.0285081 · Cited by 7
“Invasive feedback can be provided with electrodes implanted surgically, relaying information directly to the nervous system [8, 9].”
BackgroundLin, Z., Zheng, H., Lu, Y., Zhang, J., Chai, G., & Zuo, G. (2024) · Frontiers in Computer Science · doi:10.3389/fcomp.2024.1401560 · Cited by 5
Liu, X., Hao, M., Cao, C., Niu, C. M., & Lan, N. (2017) · IEEE Life Sciences Conference (LSC) · doi:10.1109/lsc.2017.8268206 · Cited by 5
“Fruitful research to restore sensory feedback for prosthetic hands has been advanced in several directions [2].”
BackgroundVibrotactile Feedback for a Person with Transradial Amputation and Visual Loss: A Case Report
Peternell, G., Penasso, H., Luttenberger, H., Ronacher, H., Schlintner, R., Ashcraft, K. R., Gardetto, A., Ernst, J., & Kropiunig, U. (2023) · Medicina · doi:10.3390/medicina59101710 · Cited by 8
“To our knowledge, no commercially available somatosensory feedback system for upper-limb prostheses is on the market [11–13] and restoring the sensitivity of the hand remains a challenge [14–17].”
BackgroundStudy on Prosthetic Hand Proprioception Feedback Based on Hybrid Vibro-Electrotactile Stimulation
Wu, G., Gu, W., Luo, Y., Zhang, X., Li, L., Hou, J., Deng, H., Hou, W., Chen, L., & Wang, X. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3593354 · Cited by 5
“This is exemplified by the HyVE (Hybrid Vibro-Electrotactile) interface [22], which concurrently transmits both vibrotactile and electrotactile signals to the same skin region, thereby enhancing information throughput without requiring additional skin surface [23].”
Hussain, R. S., Razak, N. A. A., Alfatafta, M., Khuen, C. C., Qaroot, B. A., & Ramousse, T. (2026) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2025.1722817 · Cited by 5
“Non-invasive somatosensory feedback systems have gained significant attention (Svensson et al., 2017).”
Multichannel Sensorimotor Integration with a Dexterous Artificial Hand
Abd, M. A., & Engeberg, E. D. (2024) · Robotics · doi:10.3390/robotics13070097 · Cited by 6
Electrical nerve stimulation for sensory-neural pathway reconstruction in upper-limb amputees
Wang, Y., Liu, H., Zeng, P., Ji, L., Zhou, Y., Zhou, L., & Tao, Y. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1114962 · Cited by 5
A Review of Proprioceptive Feedback Strategies for Upper-Limb Myoelectric Prostheses
Lecompte, O., Achiche, S., & Mohebbi, A. (2024) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2024.3407532 · Cited by 10
“…for a trend observed in the literature surrounding the field of sensory restoration, citing the users’ reluctance to undergo invasive surgical procedures for the installation or the maintenance of the device [4] and their concerns about the stability of the technology through time [47], [48], [49].”
BackgroundYe, S., Zhu, K., Li, P., & Sui, X. (2019) · Journal of Shanghai Jiaotong University (Science) · doi:10.1007/s12204-019-2134-y · Cited by 4
Toward improving control performance of myoelectric arm prosthesis by adding wrist position feedback
Zheng, Y., Tian, L., Li, X., Tan, Y., Yang, Z., & Li, G. (2022) · Frontiers in Human Neuroscience · doi:10.3389/fnhum.2022.905885 · Cited by 5
“These methods can be divided into invasive and non-invasive sensory feedback methods (Svensson et al., 2017).”
MethodShi, G., Shi, J., Shariati, A., Motaghedolhagh, K., Homer‐Vanniasinkam, S., & Wurdemann, H. A. (2024) · IEEE Transactions on Haptics · doi:10.1109/toh.2024.3454179 · Cited by 5
“A spectrum of systems, including static mechano-, vibro-, electro-tactile, and hybrid models, have been assessed in [10], [11], [12].”
Idowu, O. P., Huang, J., Zhao, Y., Samuel, O. W., Yu, M., Fang, P., & Li, G. (2020) · Cognitive Neurodynamics · doi:10.1007/s11571-020-09603-8 · Cited by 4
Mayer, R. M., Mohammadi, A., Alıcı, G., Choong, P., & Oetomo, D. (2018) · Research Online (University of Wollongong) · Cited by 4
Stieglitz, T., Bersch, I., Mrachacz‐Kersting, N., & Pasluosta, C. F. (2025) · Artificial Organs · doi:10.1111/aor.15017 · Cited by 4
A psychophysical investigation on vibrotactile sensing for transradial prosthesis users
Hanif, N. H. H. M., Chappell, P. H., White, N. M., & Cranny, A. (2018) · Cogent Engineering · doi:10.1080/23311916.2018.1539943 · Cited by 4
Parsnejad, S., Dávila-Montero, S., & Mason, A. J. (2020) · IEEE World Forum on Internet of Things (WF-IoT) · doi:10.1109/wf-iot48130.2020.9221040 · Cited by 4
A framework for understanding prosthetic embodiment for the plastic surgeon
Eftekari, S. C., Sears, L. A., Moura, S. P., Garelick, S., Donnelly, D. T., Shaffrey, E. C., & Dingle, A. M. (2023) · Journal of Plastic Reconstructive & Aesthetic Surgery · doi:10.1016/j.bjps.2023.06.041 · Cited by 7
Garenfeld, M. A., Jiménez-Díaz, A., Navarro-Moreno, V., Tormo, M., Strbac, M. D., Hernández, E., Baños, R., Herrero, R., & Dosen, S. S. (2024) · IEEE Transactions on Haptics · doi:10.1109/toh.2024.3424298 · Cited by 5
“However, delivering modality-matched stimulation usually requires a complex and bulky mechanical system [11], [12].”
Hierarchical Clustering Approach for Information-Extreme Machine Learning of Hand Brush Prosthesis.
Dovbysh, A. S., & Piatachenko, V. (2021) · COLINS · Cited by 3
[Research progress on perception and feedback technology in artificial prosthesis].
Zhu, B., Chu, Y., & Zhao, X. (2019) · PubMed Central · doi:10.7507/1001-5515.201904064 · Cited by 3
Dideriksen, J. L., & Dosen, S. S. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00019-8 · Cited by 4
Measuring, modeling and fostering embodiment of robotic prosthesis
Bliek, A., Andreas, D., Beckerle, P., & Rohe, T. (2024) · Frontiers in Neuroergonomics · doi:10.3389/fnrgo.2024.1400868 · Cited by 2
“To achieve this somatotopic match, the location of the haptic stimulus should ideally match the map of referred sensations on the residual limb (Björkman et al., 2016; Svensson et al., 2017).”
BackgroundMethodInfluentialAn Ultrathin and Lightweight Soft Inflatable Actuator for Natural Tactile Sensory Feedback
Scherer, H., Iberite, F., Caserta, G., Boccardo, N., Carpaneto, J., Gruppioni, E., Micera, S., & Proietti, T. (2025) · Advanced Intelligent Systems · doi:10.1002/aisy.202500262 · Cited by 4
Valette, R., Gonzalez-Vargas, J. E., & Dosen, S. S. (2025) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-025-01793-8 · Cited by 2
“This is an important goal since non-invasive feedback methods are simpler to translate into clinical applications [31, 32], as they avoid surgical risks and can be rapidly integrated into routine care, making them particularly promising for real-world use beyond the laboratory setting.”
Haptic guidance: Advancements, challenges, and future directions in human-computer interaction
Sirwal, S. A., Ahmad, B., & Koul, M. H. (2026) · Proceedings of the Institution of Mechanical Engineers Part C Journal of Mechanical Engineering Science · doi:10.1177/09544062261416177 · Cited by 7
Sensory Substitution for Tactile Feedback in Upper Limb Prostheses
Abdelrahman, Y. M., Bennington, M. J., Huberts, J. C. D. W., Sebt, S., Talwar, N., & Cauwenberghs, G. (2021) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc46164.2021.9629539 · Cited by 2
“Other systems have circumvented this problem by placing the electrodes on remote parts of the body, but this does not provide intuitive feedback to the user [4].”
BackgroundMagbagbeola, M., Miodownik, M. A., Hailes, S. M. V., & Loureiro, R. C. V. (2022) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr55369.2022.9896412 · Cited by 3
“The most common type of sensory feedback is vibration, as its versatility can elicit a wide range of proprioceptive information that can be applied to any surface on the users’ body and mapped to the appropriate function or feedback [6-8].”
Background1-D Manual Tracing Based on a High Density Haptic Stimulation Grid - a Pilot Effort
Driscoll, B., Liu, M., & Huang, H. (2023) · IEEE World Haptics Conference (WHC) · doi:10.1109/whc56415.2023.10224505 · Cited by 3
“The substituted sensation is often through stimulators, such as electrotactile stimulation [13] [14], inflatable balloons for pressure feedback [15] [16], or vibrotactile motors [17] [18].”
BackgroundKiele, P., Laengle, G., Schmoll, M., Pasluosta, C. F., Pfeifer, R., Schüettler, M., Aszmann, O. C., & Stieglitz, T. (2024) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2024.3477267 · Cited by 3
Liu, J., Björkman, A., Antfolk, C., & Malešević, N. (2025) · IEEE Transactions on Haptics · doi:10.1109/toh.2025.3526542 · Cited by 4
“Electrotactilestimulation primarilytargetsskinreceptorsandsuperficialnerves[10],while TENSprimarilystimulatesafferentnervefibers[8]toproduce tactilesensations.”
Self-citationScarpelli, A., Cordella, F., & Zollo, L. (2025) · Journal of Neural Engineering · doi:10.1088/1741-2552/ade503 · Cited by 2
“Substitution methods (i.e. vibrotactile, electro-tactile) are sensory feedback techniques that are not matched in modality and location the stimulus on the prosthesis sensors [30].”
A novel portable device and validation procedure for transcutaneous electrical nerve stimulation
Paolini, R., Liu, F., Scarpelli, A., Demofonti, A., Cordella, F., Jiang, D., Demosthenous, A., & Zollo, L. (2025) · Wearable Technologies · doi:10.1017/wtc.2025.10004 · Cited by 3
“Upper limb myoelectric prosthetic systems implementing open-loop control have been hardly accepted by prosthesis users, contributing to a device abandonment rate of 19 – 39% (Svensson et al., 2017).”
Multi-Path Integrate and Fire Circuit for Determination of Tactile Sensations in a Prosthetic Limb
Madler, R., Kundu, A., Fahmy, A., Patrick, E. E., Bashirullah, R., & Maghari, N. (2019) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2019.8702511 · Cited by 2
“Equation [1] and [2] describe the firing rate relationship for the static and dynamic paths and show that including an offset gives a second degree of freedom when fitting the firing frequency for each I&F when combined with an adjustable threshold.”
BackgroundIntegration of a Virtual Protheses with a Multichannel Tactile Feedback Interface
Fares, H., Dosen, S. S., & Valle, M. (2019) · IEEE International Conference on Electronics, Circuits and Systems (ICECS) · doi:10.1109/icecs46596.2019.8965137 · Cited by 2
“It is hypothesized that closing the loop could improve prosthesis utility and facilitate the feeling of embodiment, minimize the phantom pain and decrease the rejection rates [1, 2].”
BackgroundMethodMayer, R. M., Mohammadi, A., Tan, Y., Alıcı, G., Choong, P., & Oetomo, D. (2020) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob49111.2020.9224406 · Cited by 3
“With the long term goal of providing prosthesis users with sensory feedback in mind ([1], [2]), several sensory feedback interfaces have been studied and developed in the past decade ([3], [4], [5], [6]).”
BackgroundMagbagbeola, M., Jevtic, T., Miodownik, M. A., Hailes, S. M. V., & Loureiro, R. C. V. (2020) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob49111.2020.9224402 · Cited by 2
“Typically, it is used to provide information about grasping force; however, research has been conducted into its application as a modality that provides texture, shape and proprioceptive information [9].”
BackgroundAutomated Complex of Motion Control Based on Vibrotactile Feedback for Rehabilitation
Kutyina, D. V., Наконечный, Д. Г., Motailo, A., Pigareva, Y., Kiseleva, A. N., Kazantsev, V., Gordleeva, S., Kaplan, A., & Pimashkin, A. S. (2017) · Современные технологии в медицине · doi:10.17691/stm2017.9.4.04 · Cited by 2
“limb prostheses because in these cases a feedback is necessary not only for training but also for normal functioning of the artificial limb [3, 4].”
BackgroundLiquid Metal Enabled Electrobiology: A Generalized Easy Going Way to Tackle Disease ChallengesPreprint
Wang, X., Ren, Y., & Liu, J. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1805.04002 · Cited by 2
“and make corresponding responses, but also feel various types of external stimuli and transmit signals to the corresponding peripheral nervous system to realize better control of prostheses (Fig. 6E) [97, 98]. For this purpose, artificial sensing skin and myoelectric prostheses can be combined to makes the prostheses…”
BackgroundДовбиш, А. С., Piatachenko, V., Myronenko, M., Suprunenko, M., & Simonovskiy, J. (2024) · Journal of Engineering Sciences · doi:10.21272/jes.2024.11(2).e1 · Cited by 1
Driscoll, B., Prabhu, N., Lee, I., Liu, M., & Huang, H. (2025) · IEEE Transactions on Haptics · doi:10.1109/toh.2025.3568705 · Cited by 2
“There are two approaches for delivering sensory feedback: sensory restoration [3] and sensory substitution [4].”
Enabling the sense of touch in EMG-controlled hand prostheses using vibro-tactile stimulation
Tayeb, Z., Jakovleski, P., Chen, Z., Lippert, J., Lanillos, P., Lee, D., & Cheng, G. (2019) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner.2019.8717124 · Cited by 1
Hong, X. (2021) · E3S Web of Conferences · doi:10.1051/e3sconf/202127104026 · Cited by 1
Multi-Electrode electrotactile Stimulation to Combat Skin Dependency in Machine-to-Human Feedback
Parsnejad, S., Ashoori, E., & Mason, A. J. (2021) · IEEE International Midwest Symposium on Circuits and Systems (MWSCAS) · doi:10.1109/mwscas47672.2021.9531684 · Cited by 2
Smart sensing and actuators for people with hand motion impairment
Izdrui, D., Geman, O., Postolache, O. A., Elahi, H., Vicoveanu, D. I., & Curea, S. (2022) · Elsevier eBooks · doi:10.1016/b978-0-323-85174-9.00002-9 · Cited by 1
Antonello, M., Collu, R., Roberto, P., Andrea, D., Cordella, F., Zollo, L., Massimo, B., & Cosseddu, P. (2025) · Scientific Reports · doi:10.1038/s41598-025-21599-x · Cited by 2
“…or electro-tactile approaches lack a somatosensory match: the elicited sensation is perceived just locally on the stump and not in the missing limb 17,66,67 and intuitiveness of sensory location and sensation are fundamental to improving dexterity and cognitive load during prosthetic wearing 17 .”
Recovery of the Response of Sensory Fibers to the Second of a Pair of Peripheral Nerve Stimuli
Brunton, E., Silveira, C. R. A., Riddell, J. S., & Nazarpour, K. (2018) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2018.8512560 · Cited by 1
“Prosthetics that stimulate the peripheral nervous system have the potential to restore sensory feedback to prosthetic hand users [1]–[3].”
BackgroundIntracortical microstimulation for tactile feedback in awake behaving rats
Devecıoğlu, İ., Öztürk, S., & Güçlü, B. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00013-7 · Cited by 1
Suprunenko, M., Zborshchyk, O. P., & Sokołov, O. (2022) · Journal of Engineering Sciences · doi:10.21272/jes.2022.9(2).e4 · Cited by 1
Tchimino, J. (2023) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau539427829 · Cited by 1
Sensory Feedback in Prosthetic Arms
Ahad, N. A. (2019) · Lund University Publications Student Papers (Lund University)
Beckerle, P. (2021) · Springer series on touch and haptic systems · doi:10.1007/978-3-030-38688-7_8
Brain-Machine Interfaces for Upper and Lower Limb Prostheses
Brantley, J. A., Paek, A. Y., Steele, A. G., & Contreras-Vidal, J. L. (2022) · Handbook of Neuroengineering · doi:10.1007/978-981-15-2848-4_35-2 · Cited by 3
Gholinezhad, S. (2022) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau498358925
“Despite the availability of incidental feedback, it is likely that the presence of supplementary feedback can still enhance the quality of the state estimation [8], [15], [22], [23].”
BackgroundMethodInfluentialMagbagbeola, M., Miodownik, M. A., Hailes, S. M. V., & Loureiro, R. C. V. (2022) · IEEE/RAS-EMBS International Conference on Biomedical Robotics and Biomechatronics (BioRob) · doi:10.1109/biorob52689.2022.9925430
“Through technological advancements in sensory feedback, both prosthetic users and able-bodied individuals are able to feel a variety of tactile information from the external environment [1-3].”
BackgroundSridhar, V. (2022) · IEEE MIT Undergraduate Research Technology Conference (URTC) · doi:10.1109/urtc56832.2022.10002232
“In this paper, a mixed method approach was used to demonstrate Non-Invasive proof of concepts that involves modality matched Mechanotactile stimulation [7],[10].”
MethodReal-time vibrotactile pattern generation and identification using discrete event-driven feedback
Erbaş, İ., & Güçlü, B. (2023) · Somatosensory & Motor Research · doi:10.1080/08990220.2023.2175811 · Cited by 1
“It is also compatible with EMG control and the acceptance rate is good (Kaczmarek et al. 1991; Svensson et al. 2017; Stephens-Fripp et al. 2018).”
BackgroundBrain-Machine Interfaces for Upper and Lower Limb Prostheses
Brantley, J. A., Paek, A. Y., Steele, A. G., & Contreras-Vidal, J. L. (2023) · Handbook of Neuroengineering · doi:10.1007/978-981-16-5540-1_35
Intraneural SiC multi electrodes to detect multimodal sensory signals
González‐González, M. A., Ghazavi, A., Cogan, S. F., & Romero‐Ortega, M. I. (2023) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner52421.2023.10123843
“Technologies in neural interfaces include invasive and nor invasive approaches targeting nerves or muscle, being a main challenge the degree of freedom and sensibility for signal discrimination [8], [9].”
BackgroundGarenfeld, M. A. (2023) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau561809161
Mamidanna, P. (2023) · VBN Forskningsportal (Aalborg Universitet) · doi:10.54337/aau561808227
Innovatives nichtinvasives gangsynchrones vibrotaktiles Feedbacksystem: „Ich fühle, wie ich gehe“
Kalff, M. N., Witowski, V., Hoursch, V., Kirsten, N., Niehage, L., Kramer, H., Gardetto, A., Sehmisch, S., & Ernst, J. (2024) · Die Unfallchirurgie · doi:10.1007/s00113-024-01466-6
Vadeghani, E. M., Moallemi, A., & Shahriari, D. (2024) · Elsevier eBooks · doi:10.1016/b978-0-323-95730-4.00005-6
Barontini, F. (2024) · Springer series on touch and haptic systems · doi:10.1007/978-3-031-70539-7_1
Can Force Feedback Improve the Control of a Neuroprosthesis?
Barontini, F. (2024) · Springer series on touch and haptic systems · doi:10.1007/978-3-031-70539-7_6 · Cited by 1
Toward Somatotopic Matching: The Wearable Integrated Soft Haptic Device (WISH)
Barontini, F. (2024) · Springer series on touch and haptic systems · doi:10.1007/978-3-031-70539-7_7
Hirao, Y., & Hashimoto, T. (2024) · SIGGRAPH Asia Emerging Technologies · doi:10.1145/3681755.3688943
Psychophysical Evaluation of A Mechanotactile Haptic Feedback Device
Roshan, D., Shariati, A., Motaghedolhagh, K., Wurdemann, H. A., & Mukherjee, B. (2025) · International Conference on Rehabilitation Robotics · doi:10.1109/icorr66766.2025.11063024
Baljić, M., Garenfeld, M. A., Borg, A. L., Budimir, F., Kojić, V., Dosen, S. S., & Strbac, M. D. (2025) · International Conference on Electrical, Electronic and Computing Engineering (IcETRAN) · doi:10.1109/icetran66854.2025.11114296
“While various electrical and mechanical feedback methods have been proposed [10], they usually convey only one or two low-resolution variables, such as grasping force and hand aperture [11].”
Optimizing Electrotactile Stimulation Parameters for Responses under Cognitive LoadPreprint
Jarto, F., Corbett, E., & Dupan, S. S. G. (2025) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2025.09.08.674827
Somatotopic non-invasive proprioceptive feedback strategy for prosthetic hands: a preliminary study
Lecompte, O., Achiche, S., Gesta, A., & Mohebbi, A. (2025) · Biomedical Physics & Engineering Express · doi:10.1088/2057-1976/ae093e · Cited by 1
Magnetically Induced Skin Stretch Enhances Proprioceptive Feedback in Prosthetics
Fontana, E., Catalano, M. G., Grioli, G., Bianchi, M., & Bicchi, A. (2025) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2025.3633082
“Despite these challenges, invasive methodologies hold considerable promise for advancing the next generation of high-performance bionic limbs, potentially bridging the gap between biological and artificial sensory integration [69], [70].”
Peresada, D., Mzeihem, M., & Rybalko, D. A. (2025) · Springer eBooks · doi:10.1007/978-3-032-04688-8_26
Validation and Verification of a Haptic Interface for Body-Powered Partial Hand Prostheses
Motaghedolhagh, K., Shariati, A., Hardwicke, J., Homer‐Vanniasinkam, S., & Wurdemann, H. A. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11253578
“This is referred to as modality-matched feedback when a participant perceives the information in the same way as the original stimulus [3].”
Neuro-computational modelling of closed-loop prostheses control
Nacci, L., Sanguineti, V., & Dosen, S. S. (2025) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc58623.2025.11254755
“The supplementary feedback can be provided by leveraging haptic, vibrotactile, electrotactile, or osseoperception-based approaches [4], [5].”
Meng, X., Meng, J., Chai, G., Sheng, M. X., & Zhu, X. L. (2026) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2026.3653788
“Supplementary sensory feedback can be delivered invasively or non-invasively [18].”
A Multi-Criteria Framework for Transparency in the Design and Use of Brain-Computer Interfaces
Zilio, F. (2026) · AJOB Neuroscience · doi:10.1080/21507740.2025.2606296
“Consider a hypothetical but technologically realistic case (Svensson et al. 2017): a cortically controlled upper limb neuroprosthesis with adaptive AI feedback (Table 1).”
Optimizing electrotactile stimulation intensity for responses under cognitive load
Jarto, F., Corbett, E., & Dupan, S. S. G. (2026) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-026-01883-1
Nabawi, S., El-Sayed, A.-H. M., Marzouk, W. W., & Salah, O. (2026) · International Journal of Intelligent Robotics and Applications · doi:10.1007/s41315-026-00533-y
“…various grip patterns and the ability to emulate the real hand, imposes more challenges that reflect on the whole functionality of the prosthetic system, with the ability to collect and utilize sensory and proprioceptive inputs from these prostheses being the most affected (Svensson et al. 2017).”
Augmenting natural skin stretch during active finger motion reshapes hand proprioception
Fontana, E., Moscatelli, A., Catalano, M. G., Bicchi, A., & Bianchi, M. (2026) · Journal of The Royal Society Interface · doi:10.1098/rsif.2025.1242 · Cited by 2
Movement is a Sensory Phenomenon
Tereshenko, V., & Aszmann, O. C. (2026) · Hand Clinics · doi:10.1016/j.hcl.2026.03.005
Cheng, C. H., Eden, J., Oetomo, D., & Tan, Y. (2026) · IEEE Transactions on Haptics · doi:10.1109/toh.2026.3702652
“Electrotactile actuators are particularly suitable for these multi-actuator setups because they are small and can be placed close together while still being distinguishable by the user, allowing denser arrangements and higher-resolution feedback [17], [18].”
Marliani, V., Mori, T., Anselmi, M., Cappello, L., Mastinu, E., & Cipriani, C. (2026) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2026.3719427
“In recent years, several approaches to provide sensory feedback and close the sensory-motor control loop have been proposed, including invasive and non-invasive strategies [13], [14].”
Metadata
- Authors
- Svensson, P., Wijk, U., Björkman, A., & Antfolk, C.
- Affiliations
- Lund University (SE)
- Skåne University Hospital (SE)
- Corresponding author
- Antfolk, Christian
- Venue
- Expert Review of Medical Devices
- Publisher
- Informa UK Limited
- Published
- 2017-05-31
- Volume
- 14
- Issue
- 6
- Pages
- 439-447
- ISSN
- 1743-4440 (ISSN-L)
- 1745-2422
- OpenAlex
- W2619254759
- Cited by
- 192
- References
- 68
- Citations by year
- 2026: 10 · 2025: 19 · 2024: 25 · 2023: 33 · 2022: 24 · 2021: 25 · 2020: 22 · 2019: 20 · 2018: 12 · 2017: 2
- FWCI
- 1.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Expert Review of Medical Devices (publishedVersion)
- PubMed (publishedVersion)
- Lund University Publications (Lund University) (submittedVersion)
- Funders
- Swedish Research Council (637-2013-444)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- sensory feedback, upper limb prosthesis, prosthetic hand, vibrotactile feedback, electrotactile feedback, cuff electrodes, embodiment, upper limb amputees, prosthesis acceptance
- MeSH terms
- Amputees, Artificial Limbs, Body Image, Electrodes, Implanted, Hand, Humans, Prosthesis Design, Upper Extremity, Feedback, Sensory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.