A review of invasive and non-invasive sensory feedback in upper limb prostheses
The DOI matches its Crossref record; 67 of the 68 references it cites were found in a registry or an index.
Abstract
INTRODUCTION: The constant challenge to restore sensory feedback in prosthetic hands has provided several research solutions, but virtually none has reached clinical fruition. A prosthetic hand with sensory feedback that closely imitates an intact hand and provides a natural feeling may induce the prosthetic hand to be included in the body image and also reinforces the control of the prosthesis. Areas covered: This review presents non-invasive sensory feedback systems such as mechanotactile, vibrotactile, electrotactile and combinational systems which combine the modalities; multi-haptic feedback. Invasive sensory feedback has been tried less, because of the inherent risk, but it has successfully shown to restore some afferent channels. In this review, invasive methods are also discussed, both extraneural and intraneural electrodes, such as cuff electrodes and transverse intrafascicular multichannel electrodes. The focus of the review is on non-invasive methods of providing sensory feedback to upper-limb amputees. Expert commentary: Invoking embodiment has shown to be of importance for the control of prosthesis and acceptance by the prosthetic wearers. It is a challenge to provide conscious feedback to cover the lost sensibility of a hand, not be overwhelming and confusing for the user, and to integrate technology within the constraint of a wearable prosthesis.
Overview
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
Citations
Cites
Rubber hands ‘feel’ touch that eyes see
Botvinick, M., & Cohen, J. (1998) · Nature · doi:10.1038/35784 · Cited by 4,410
Zagrean, L. (2014) · Acta Endocrinologica (Bucharest) · doi:10.4183/aeb.2014.529 · Cited by 1,909
High-performance neuroprosthetic control by an individual with tetraplegia
Collinger, J. L., Wodlinger, B., Downey, J. E., Wang, W., Tyler-Kabara, E. C., Weber, D. J., McMorland, A. J., Velliste, M., Boninger, M. L., & Schwartz, A. B. (2013) · The Lancet · doi:10.1016/s0140-6736(12)61816-9 · Cited by 1,848
Stretchable silicon nanoribbon electronics for skin prosthesis
Kim, J., Lee, M., Shim, H. J., Ghaffari, R., Cho, H. R., Son, D., Jung, Y. H., Soh, M., Choi, C., Jung, S., et al. (2014) · Nature Communications · doi:10.1038/ncomms6747 · Cited by 1,435
Upper limb prosthesis use and abandonment: A survey of the last 25 years
Biddiss, E. A., & Chau, T. T. (2007) · Prosthetics & Orthotics International · doi:10.1080/03093640600994581 · Cited by 1,111
The perception of phantom limbs. The D. O. Hebb lecture
Ramachandran, V. (1998) · Brain · doi:10.1093/brain/121.9.1603 · Cited by 1,064
Restoring natural sensory feedback in real-time bidirectional hand prostheses
Raspopovic, S., Capogrosso, M., Petrini, F. M., Bonizzato, M., Rigosa, J., Di Pino, G., Carpaneto, J., Controzzi, M., Boretius, T., Fernandez, E., et al. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3006820 · Cited by 1,001
Literature Review on Needs of Upper Limb Prosthesis Users
Cordella, F., Ciancio, A. L., Sacchetti, R., Davalli, A., Cutti, A. G., Guglielmelli, E., & Zollo, L. (2016) · Frontiers in Neuroscience · doi:10.3389/fnins.2016.00209 · Cited by 752
A neural interface provides long-term stable natural touch perception
Tan, D. W., Schiefer, M. A., Keith, M. W., Anderson, J. R., Tyler, J., & Tyler, D. J. (2014) · Science Translational Medicine · doi:10.1126/scitranslmed.3008669 · Cited by 751
Intracortical microstimulation of human somatosensory cortex
Flesher, S. N., Collinger, J. L., Foldes, S. T., Weiss, J. M., Downey, J. E., Tyler-Kabara, E. C., Bensmaia, S. J., Schwartz, A. B., Boninger, M. L., & Gaunt, R. A. (2016) · Science Translational Medicine · doi:10.1126/scitranslmed.aaf8083 · Cited by 704
Research works printed but not linked: 7
- Alessandro C, 2015, Biosystems & biorobotics, 225
- 10.1053/hanthe.2002.v15.01562 · doi:10.1053/hanthe.2002.v15.01562 · Paper page
- Purves D, 2012, Neuroscience
- Weber EH, 1978, E. H. Weber: the sense of touch
- Clemente F, 2015, IEEE Trans Neural Syst Rehabil Eng
- Desai VH, 2014, Conf Proc IEEE Eng Med Biol Soc, 2014, 1973
- Wodlinger B, 2014, J Neural Eng, 12, 0106011
Cited by
A Review of Sensory Feedback in Upper-Limb Prostheses From the Perspective of Human Motor Control
Sensinger, J. W., & Dosen, S. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00345 · Cited by 230
A Review of Non-Invasive Sensory Feedback Methods for Transradial Prosthetic Hands
Stephens-Fripp, B., Alici, G., & Mutlu, R. (2018) · IEEE Access · doi:10.1109/access.2018.2791583 · Cited by 210
“[31] provided a brief overview of sensors used to detect stimuli, as well as some of the invasive and noninvasive methods used to provide sensory feedback.”
MethodSalminger, S., Sturma, A., Hofer, C., Evangelista, M., Perrin, M., Bergmeister, K. D., Roche, A. D., Hasenoehrl, T., Dietl, H., Farina, D., et al. (2019) · Science Robotics · doi:10.1126/scirobotics.aaw6306 · Cited by 139
Marasco, P. D., Hebert, J. S., Sensinger, J. W., Beckler, D. T., Thumser, Z. C., Shehata, A. W., Williams, H. E., & Wilson, K. R. (2021) · Science Robotics · doi:10.1126/scirobotics.abf3368 · Cited by 156
Marković, M., Schweisfurth, M. A., Engels, L. F., Bentz, T., Wüstefeld, D., Farina, D., & Dosen, S. S. (2018) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-018-0371-1 · Cited by 151
“However, while state-of-the-art (SoA) commercial myoelectric prostheses do provide control of a dexterous, multi degrees of freedom (DoF) hand, thereby restoring the motor function, an effective method to provide sensory feedback is still missing [1 – 3].”
BackgroundProsthetic embodiment: systematic review on definitions, measures, and experimental paradigms
Zbinden, J., Lendaro, E., & Ortiz-Catalan, M. (2022) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-022-01006-6 · Cited by 157
“Recent technological progress has produced prostheses with increasingly faithful volitional control [2, 3] and sensory feedback [4, 5].”
BackgroundInterfaces with the peripheral nervous system for the control of a neuroprosthetic limb: a review
Yildiz, K. A., Shin, A. Y., & Kaufman, K. R. (2020) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-020-00667-5 · Cited by 113
“As these systems interface with the muscles, an additional feedback modality should also be employed in order to close the loop and provide the user with sensory feedback [18].”
BackgroundActive upper limb prostheses: a review on current state and upcoming breakthroughs
Marinelli, A., Boccardo, N., Tessari, F., Domenico, D. D., Caserta, G., Canepa, M., Gini, G. C., Barresi, G., Laffranchi, M., Michieli, L. D., et al. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/acac57 · Cited by 132
“Sensory feedback patterns are designed to enrich the perceived responsiveness of the device and the subjective experience of its use as a limb (Antfolk et al 2013b, Svensson et al 2017, Raspopovic et al 2021a).”
Jiang, N., Chen, C., He, J., Meng, J., Pan, L., Su, S., & Zhu, X. (2023) · National Science Review · doi:10.1093/nsr/nwad048 · Cited by 110
“Please refer to [32] for an excellent review of invasive methods.”
Kumar, D., Jelfs, B., Sui, X., & Arjunan, S. P. (2019) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2019.101588 · Cited by 90
Toledo-Peral, C. L., Vega-Martínez, G., Mercado-Gutierrez, J. A., Rodríguez‐Reyes, G., Vera, A., Leija, L., & Gutiérrez-Martínez, J. (2022) · Electronics · doi:10.3390/electronics11142271 · Cited by 88
Feel-Good Robotics: Requirements on Touch for Embodiment in Assistive Robotics
Beckerle, P., Kõiva, R., Kirchner, E. A., Bekrater‐Bodmann, R., Dosen, S. S., Christ, O., Abbink, D. A., Castellini, C., & Lenggenhager, B. (2018) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2018.00084 · Cited by 83
“The majority of contemporary tactile feedback techniques, however, focus on low-density and spatially constrained tactile feedback related to active touch of external objects typically through fingers and hand (Antfolk et al., 2013b; Schofield et al., 2014; Svensson et al., 2017; Stephens-Fripp et al., 2018).”
BackgroundLimakatso, K., & Parker, R. (2021) · PM&R · doi:10.1002/pmrj.12556 · Cited by 76
Soft Robotics Enables Neuroprosthetic Hand Design
Gu, G., Zhang, N., Chen, C., Xu, H., & Zhu, X. (2023) · ACS Nano · doi:10.1021/acsnano.3c01474 · Cited by 64
“Noninvasive feedback 126,132,145 is a kind of “indirect” method to elicit the sensation by delivering the sensory information through stimulation devices on the remanent skin of amputees.”
A wirelessly programmable, skin-integrated thermo-haptic stimulator system for virtual reality
Kim, J.-H., Vázquez‐Guardado, A., Luan, H., Kim, J.-T., Yang, D. S., Zhang, H., Chang, J., Yoo, S., Park, C., Wei, Y., et al. (2024) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.2404007121 · Cited by 60
Sensory- and Action-Oriented Embodiment of Neurally-Interfaced Robotic Hand Prostheses
Di Pino, G., Romano, D., Spaccasassi, C., Mioli, A., D’Alonzo, M., Sacchetti, R., Guglielmelli, E., Zollo, L., Di Lazzaro, V., Denaro, V., et al. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00389 · Cited by 52
Schoepp, K. R., Dawson, M. R. W., Schofield, J. S., Carey, J. P., & Hebert, J. S. (2018) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2018.2866105 · Cited by 60
“This system allowed us to evaluate capabilities in an unrestricted laboratory environment, closer to being representative of a real-world setting, which is a key step towards adequate evaluation of novel feedback for myoelectric systems [7], [20].”
BackgroundInfluentialDonati, E., & Indiveri, G. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/acb51c · Cited by 56
“However, restoring sensory feedback in prosthetic hands is still an open challenge and several research solutions have been proposed, using both non-invasive and invasive methods [24].”
MethodSensory Feedback in Hand Prostheses: A Prospective Study of Everyday Use
Wijk, U., Carlsson, I. K., Antfolk, C., Björkman, A., & Rosén, B. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00663 · Cited by 54
Self-citationHandelzalts, S., Ballardini, G., Avraham, C., Pagano, M., Casadio, M., & Nisky, I. (2021) · Frontiers in Neurorobotics · doi:10.3389/fnbot.2021.617636 · Cited by 48
“, 1989), as well as in prostheses, orthoses (Schweisfurth et al., 2016; Svensson et al., 2017) and stroke rehabilitation (for a review see Laufer and Elboim-Gabyzon, 2011).”
BackgroundSensory nerve regeneration and reinnervation in muscle following peripheral nerve injury
Adidharma, W., Khouri, A. N., Lee, J. C., Vanderboll, K., Kung, T. A., Cederna, P. S., & Kemp, S. W. P. (2022) · Muscle & Nerve · doi:10.1002/mus.27661 · Cited by 50
Masteller, A. M., Sankar, S., Kim, H., Ding, K., Liu, X., & All, A. H. (2020) · Annals of Biomedical Engineering · doi:10.1007/s10439-020-02678-8 · Cited by 46
Chai, G., Wang, H., Li, G., Sheng, X., & Zhu, X. (2022) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2022.3173329 · Cited by 45
Vargas, L., Huang, H., Zhu, Y., & Hu, X. (2020) · IEEE Transactions on Haptics · doi:10.1109/toh.2020.2967366 · Cited by 41
“It promotes essential object manipulation [1], and allows us to detect object physical properties without the need for visual/auditory feedback”
Li, M., Zhang, D., Chen, Y., Chai, X., He, L., Chen, Y., Guo, J., & Sui, X. (2018) · Frontiers in Neuroscience · doi:10.3389/fnins.2018.00283 · Cited by 46
“Practically, the significance of sensory feedback has been noticed ever since the 1950s (Clippinger et al., 1974), and has attracted great interest in recent years (Jiang et al., 2012; Antfolk et al., 2013b; Delhaye et al., 2016; Svensson et al., 2017).”
BackgroundMethodInfluentialEvoked Haptic Sensation in the Hand With Concurrent Non-Invasive Nerve Stimulation
Vargas, L., Whitehouse, G., Huang, H., Zhu, Y., & Hu, X. (2019) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2019.2895575 · Cited by 43
“[17]–[19].”
State of the Art in Bionic Hands
Basumatary, H., & Hazarika, S. M. (2020) · IEEE Transactions on Human-Machine Systems · doi:10.1109/thms.2020.2970740 · Cited by 44
“In the former case, the sensory loop remains inside the prostheses and may not include the user [21].”
BackgroundCognitive benefits of using non-invasive compared to implantable neural feedback
Chee, L., Valle, G., Preatoni, G., Basla, C., Marazzi, M., & Raspopović, S. (2022) · Scientific Reports · doi:10.1038/s41598-022-21057-y · Cited by 40
Garenfeld, M. A., Mortensen, C. K., Strbac, M. D., Dideriksen, J. L., & Dosen, S. S. (2020) · Journal of Neural Engineering · doi:10.1088/1741-2552/aba4fd · Cited by 40
“In most studies in the literature, feedback interfaces were designed to transmit a single feedback variable, most often the grasping force [14, 26].”
BackgroundVargas, L., Shin, H., Huang, H., Zhu, Y., & Hu, X. (2019) · Journal of Neural Engineering · doi:10.1088/1741-2552/ab4d99 · Cited by 43
“Tactile feedback plays a critical role when we interact with objects, and a lack of such feedback can limit motor performance and limit control of assistive devices, such as prosthetic arms or remotely operated manipulators [1, 2].”
BackgroundAbbass, Y., Saleh, M., Dosen, S. S., & Valle, M. (2021) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2021.3107723 · Cited by 44
Psychometric characterization of incidental feedback sources during grasping with a hand prosthesis
Schweisfurth, M. A., Niethammer, C., Meyer, B., Farina, D., & Dosen, S. S. (2019) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-019-0622-9 · Cited by 37
Gardetto, A., Baur, E., Prahm, C., Smekal, V., Jeschke, J., Peternell, G., Pedrini, M. T., & Kolbenschlag, J. (2021) · Journal of Clinical Medicine · doi:10.3390/jcm10174029 · Cited by 38
Bionic hand as artificial organ: Current status and future perspectives
Aman, M., Sporer, M. E., Gstoettner, C., Prahm, C., Höfer, C., Mayr, W., Farina, D., & Aszmann, O. C. (2019) · Artificial Organs · doi:10.1111/aor.13422 · Cited by 47
Human motor augmentation with an extra robotic arm without functional interference
Dominijanni, G., Pinheiro, D. J. L. L., Pollina, L., Orset, B., Gini, M., Anselmino, E., Pierella, C., Olivier, J., Shokur, S., & Micera, S. (2023) · Science Robotics · doi:10.1126/scirobotics.adh1438 · Cited by 38
“…is coherent with previous findings on the effect of visuorespiratory synchronization on the embodiment of virtual bodies ( 37 ), we would have expected an increased sense of ownership over the XVA when haptic feedback on its state was provided through the haptic feedback display ( 40 , 46–49 ).”
ResultDual-Parameter Modulation Improves Stimulus Localization in Multichannel Electrotactile Stimulation
Seminara, L., Fares, H., Franceschi, M., Valle, M., Strbac, M. D., Farina, D., & Dosen, S. S. (2019) · IEEE Transactions on Haptics · doi:10.1109/toh.2019.2950625 · Cited by 35
A compact system for simultaneous stimulation and recording for closed-loop myoelectric control
Garenfeld, M. A., Jorgovanović, N., Ilić, V., Strbac, M. D., Isaković, M. S., Dideriksen, J. L., & Dosen, S. S. (2021) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-021-00877-5 · Cited by 33
“In fact, a sensory intact residual limb is in many cases more valuable to the user [5].”
BackgroundGuo, W., Xu, W., Zhao, Y., Shi, X., Sheng, X., & Zhu, X. (2023) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2023.3292419 · Cited by 34
“theses are inadequate to match dexterous operation [7], [8].”
BackgroundRaveh, E., Portnoy, S., & Friedman, J. (2018) · Archives of Physical Medicine and Rehabilitation · doi:10.1016/j.apmr.2018.05.019 · Cited by 34
“Over the years, several studies investigated the benefits of adding VTF to a myoelectric prosthesis.(7,8) Most of these studies evaluated the role of VTF in assisting the prosthesis user to better control the applied force when grasping an object(9-11) or to have an improved object discrimination.”
BackgroundMultiparametric non-linear TENS modulation to integrate intuitive sensory feedback
Bucciarelli, V., Gozzi, N., Katic, N., Aiello, G., Razzoli, M., Valle, G. D., & Raspopović, S. (2023) · Journal of Neural Engineering · doi:10.1088/1741-2552/acd4e8 · Cited by 36
“at the heel-strike, we should perceive a pressure sensation directly under the heel) [2, 20, 38, 39].”
BackgroundClosed-loop Control using Electrotactile Feedback Encoded in Frequency and Pulse Width
Dideriksen, J. L., Mercader, I. U., & Dosen, S. S. (2020) · IEEE Transactions on Haptics · doi:10.1109/toh.2020.2985962 · Cited by 32
“In the latter, the stimulation can be delivered non-invasively using surface electrodes placed on the skin [21] or invasively by stimulating peripheral nerves [22], [23].”
MethodFluidic Haptic Interface for Mechano-Tactile Feedback
Shi, G., Palombi, A., Lim, Z., Astolfi, A., Burani, A., Campagnini, S., Loizzo, F. G. C., Preti, M. L., Vargas, A. M., Peperoni, E., et al. (2020) · IEEE Transactions on Haptics · doi:10.1109/toh.2020.2970056 · Cited by 28
“In [10], [11], mechano-, vibro-, electro-tactile and hybrid systems have been reviewed.”
BackgroundTchimino, J., Marković, M., Dideriksen, J. L., & Dosen, S. S. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac07be · Cited by 29
Sando, I. C., Adidharma, W., Nedic, A., Ursu, D. C., Mays, E. A., Hu, Y., Kubiak, C. A., Sugg, K. B., Kung, T. A., Cederna, P. S., et al. (2022) · Plastic & Reconstructive Surgery · doi:10.1097/prs.0000000000010086 · Cited by 30
Puma, D. R. C., Quispe, C. G. C., & Yanyachi, P. R. (2023) · HardwareX · doi:10.1016/j.ohx.2023.e00439 · Cited by 26
“Sensory feedback is essential for grasping objects, manipulation of the human hand, and for efficient motor planning and execution [18].”
BackgroundHuang, H., Hargrove, L. J., Ortiz-Catalan, M., & Sensinger, J. W. (2024) · Annual Review of Biomedical Engineering · doi:10.1146/annurev-bioeng-110222-095816 · Cited by 42
Ashraf, H., Waris, A., Gilani, S. O., Kashif, A. S., Jamil, M., Jochumsen, M., & Niazi, I. K. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/abcc7f · Cited by 27
“Two steps are required for the decomposition of composite EMG signal in classic approaches, i.e. (a) detecting action potentials by using windowing and (b) recognition of detected action potentials as a member of a specific class [8–10].”
Toward the Development of User-Centered Neurointegrated Lower Limb Prostheses
Barberi, F., Anselmino, E., Mazzoni, A., Goldfarb, M. T., & Micera, S. (2023) · IEEE Reviews in Biomedical Engineering · doi:10.1109/rbme.2023.3309328 · Cited by 32
“On the other hand, they need a higher current to stimulate the neurons and stimulate a larger portion of the nerves, making this technique less selective compared to the intraneural counterparts [162].”
BackgroundInfluentialMayer, R. M., Garcia-Rosas, R., Mohammadi, A., Tan, Y., Alıcı, G., Choong, P., & Oetomo, D. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00348 · Cited by 27
“The minimum spatial resolution is 40 mm for mechanotactile and vibrotactile feedback (on the forearm) and 9 mm for electrotactile feedback (Svensson et al., 2017).”
BackgroundDideriksen, J. L., Marković, M., Lemling, S., Farina, D., & Dosen, S. S. (2021) · IEEE Transactions on Haptics · doi:10.1109/toh.2021.3117628 · Cited by 24
Abbass, Y., Dosen, S. S., Seminara, L., & Valle, M. (2022) · Philosophical Transactions of the Royal Society A Mathematical Physical and Engineering Sciences · doi:10.1098/rsta.2021.0017 · Cited by 30
A review of upper limb pediatric prostheses and perspectives on future advancements
Battraw, M. A., Fitzgerald, J., Joiner, W. M., James, M. A., Bagley, A. M., & Schofield, J. S. (2022) · Prosthetics and Orthotics International · doi:10.1097/pxr.0000000000000094 · Cited by 27
“Furthermore, multiple peripheral nerve interfaces have been described in literature that measure and decode affected nerve activity for prosthetic control and even stimulate nerves to provide prosthetic sensory feedback.(58,59) Although many NMIs have shown significant promise in achieving intuitive prosthesis control…”
BackgroundGašparić, F., Jorgovanović, N., Höfer, C., Russold, M., Koppe, M., Stanišić, D., & Dosen, S. S. (2023) · IEEE Transactions on Haptics · doi:10.1109/toh.2023.3293545 · Cited by 23
“tion due to their low power consumption, ease of use, and small motor size [23], [24].”
BackgroundGuémann, M., Halgand, C., Bastier, A., Lansade, C., Borrini, L., Lapeyre, E., Cattaert, D., & de Rugy, A. (2022) · Journal of NeuroEngineering and Rehabilitation · doi:10.1186/s12984-022-01038-y · Cited by 30
“However, the actual use of such devices is somehow limited by the surgical procedure involved, the potential nerve damage and the limited lifetime of the implant [26].”
BackgroundInfluentialNizamis, K., Stienen, A. H. A., Kamper, D. G., Keller, T., Plettenburg, D. H., Rouse, E. J., Farina, D., Koopman, H. F. J. M., & Sartori, M. (2019) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2019.2912453 · Cited by 24
“impaired, similar to what is done for amputees [119].”
ResultClosed-Loop Multi-Amplitude Control for Robust and Dexterous Performance of Myoelectric Prosthesis
Marković, M., Varel, M., Schweisfurth, M. A., Schilling, A. F., & Dosen, S. S. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2959714 · Cited by 24
“Importantly, the vibrotactile stimulation did not transmit the state of the prosthesis as usually done in literature [24], [25]; instead, the role of feedback was to communicate the state of the CMAC controller to the subject.”
BackgroundWearable Integrated Soft Haptics in a Prosthetic Socket
Barontini, F., Catalano, M. G., Grioli, G., Bianchi, M., & Bicchi, A. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3060432 · Cited by 26
“The latter exploit sensory substitution through the usage of wearable haptic devices [8].”
BackgroundGholinezhad, S., Dosen, S. S., & Dideriksen, J. L. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac1fce · Cited by 24
“Furthermore, exploiting this stream is assumed to imply a substantial cognitive load since the sensation of tingling must be actively re-interpreted as the modality that is encoded in the feedback (in this case grasp force) [30].”
A neurocognitive pathway for engineering artificial touch
Nisky, I., & Makin, T. R. (2024) · Science Advances · doi:10.1126/sciadv.adq6290 · Cited by 25
A Decade of Haptic Feedback for Upper Limb Prostheses
Dey, A., Basumatary, H., & Hazarika, S. M. (2023) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2023.3310045 · Cited by 21
“Although most studies have provided feedback to enhance a closed-loop control in real-time [18], [22], [61], it is worth mentioning that discrete stimulation can also be used.”
BackgroundMethodInfluentialReal-Time Performance of a Tactile Neuroprosthesis on Awake Behaving Rats
Öztürk, S., Devecıoğlu, İ., Beygi, M., Atasoy, A., Mutlu, S., Özkan, M., & Güçlü, B. (2019) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2019.2910320 · Cited by 18
“nerves, non-invasive methods are also sometimes used for providing tactile feedback [14].”
BackgroundMethodBidirectional bionic limbs: a perspective bridging technology and physiology
Pasluosta, C. F., Kiele, P., Čvančara, P., Micera, S., Aszmann, O. C., & Stieglitz, T. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac4bff · Cited by 19
Resembled Tactile Feedback for Object Recognition Using a Prosthetic Hand
Vargas, L., Huang, H., Zhu, Y., Kamper, D. G., & Hu, X. (2022) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2022.3196958 · Cited by 18
“to alleviate motor deficits in arm amputees, intuitive control of prostheses is still limited, in part due to the lack of sensory information [3].”
BackgroundMarinelli, A., Boccardo, N., Canepa, M., Domenico, D. D., Semprini, M., Chiappalone, M., Laffranchi, M., Michieli, L. D., & Dosen, S. S. (2023) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2023.3285850 · Cited by 18
Rekant, J., Fisher, L. E., Boninger, M. L., Gaunt, R. A., & Collinger, J. L. (2022) · Assistive Technology · doi:10.1080/10400435.2021.2020935 · Cited by 18
Liquid Metal Enabled Electrobiology: A New Frontier to Tackle Disease Challenges
Wang, X., Ren, Y., & Liu, J. (2018) · Micromachines · doi:10.3390/mi9070360 · Cited by 35
“To meet even higher standards, a smart prosthetic hand should not only receive the instructions from the nervous system and make corresponding responses, but also feel various types of external stimuli and transmit signals to the corresponding peripheral nervous system to realize better control (Figure 6E) [103,105].”
BackgroundExcitation of natural spinal reflex loops in the sensory-motor control of hand prostheses
Alva, P. G. S., Boesendorfer, A., Aszmann, O. C., Ibáñez, J., & Farina, D. (2024) · Science Robotics · doi:10.1126/scirobotics.adl0085 · Cited by 18
“Although invasive technologies offer a homologous natural sensation to convey information about the prosthesis and its interaction with the environment, their main working principle still involves the cognitive processing of sensory inputs ( 25 , 27 , 31 ).”
BackgroundStatic and dynamic proprioceptive recognition through vibrotactile stimulation
Vargas, L., Huang, H., Zhu, Y., & Hu, X. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac0d43 · Cited by 16
“To overcome these losses, several studies have implemented sensory substitutional techniques that provide vibrotactile, electrotactile, or mechanotactile stimulation to the skin surface of the users [23–30].”
Substitutive proprioception feedback of a prosthetic wrist by electrotactile stimulation
Han, Y., Lu, Y., Zuo, Y., Song, H., Chou, C.-H., Xing, W., Li, X., Li, L., Niu, C. M., & Hou, W. (2023) · Frontiers in Neuroscience · doi:10.3389/fnins.2023.1135687 · Cited by 18
“Moreover, the electrotactile substitution system is easier to embed into upper-limb prostheses (Svensson et al., 2017) due to its benefits, such as non-invasiveness, portability, and low power consumption (Cornman et al.”
BackgroundGašparić, F., Jorgovanović, N., Höfer, C., Russold, M., Koppe, M., Stanišić, D., & Dosen, S. S. (2023) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2023.3330502 · Cited by 18
“Accordingly, there have been various attempts to restore sensory information and hence close the control loop [10], [11], [12].”
BackgroundWijk, U., Svensson, P., Antfolk, C., Carlsson, I. K., Björkman, A., & Rosén, B. (2019) · Journal of Rehabilitation Medicine · doi:10.2340/16501977-2518 · Cited by 16
“Advances in engineering have made it possible to build more advanced hand prostheses with improved grasping alternatives and range of motion (2, 3), but there is no hand prosthesis that is even close to replacing all of the lost functions (1).”
BackgroundSelf-citationClosed-loop control of a prosthetic finger via evoked proprioceptive information
Vargas, L., Huang, H., Zhu, Y., & Hu, X. (2021) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac3c9e · Cited by 18
“Our everyday activities rely on sensory feedbackwhen we perform basic motor functions [1].”
da Costa, A. C. P. R., Filosa, M., Soares, A. B., & Oddo, C. M. (2025) · Nature Machine Intelligence · doi:10.1038/s42256-025-01076-w · Cited by 13
“Tactile feedback could be provided to persons with disabilities, such as prosthesis users or quadriplegic subjects, by means of either invasive intraneural or intracortical stimulation or non-invasive wearable interfaces 62 .”
Kashiwakura, J., Alva, P. G. S., Guerra, I. M., Bona, C., Atashzar, S. F., & Farina, D. (2023) · IEEE Transactions on Medical Robotics and Bionics · doi:10.1109/tmrb.2023.3310717 · Cited by 12
“While several methods exist to sensory feedback to establish closed-loop control [3], [79], we chose a vibrotactile feedback approach provided by a custom-designed armband (Figure 5), adapted from previous work [80].”
MethodNataletti, S., Leo, F., Seminara, L., Trompetto, C., Valle, M., Dosen, S. S., & Brayda, L. G. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00555 · Cited by 13
“Many approaches have been proposed to elicit tactile sensations, including invasive or non-invasive methods, and they have been widely applied to restore sensory feedback in prosthetic limbs (Antfolk et al., 2013b; Svensson et al., 2017).”
BackgroundScarpelli, A., Demofonti, A., Cordella, F., Coffa, U., Mereu, F., Gruppioni, E., & Zollo, L. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3443398 · Cited by 14
“Therefore, in literature, different approaches have been proposed in order to restore somatic sensations in subjects by means of both invasive and non-invasive methods [8], [9], [10], [11], [12], [13].”
BackgroundParsnejad, S., Dávila-Montero, S., & Mason, A. J. (2020) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas45731.2020.9180797 · Cited by 12
Introduction to somatosensory neuroprostheses
Güçlü, B. (2021) · Elsevier eBooks · doi:10.1016/b978-0-12-822828-9.00022-8 · Cited by 12
Sensory Feedback in Upper Limb Prostheses
Dimante, D., Logina, I., Sinisi, M., & Krūmiņa, A. (2020) · Proceedings of the Latvian Academy of Sciences Section B Natural Exact and Applied Sciences · doi:10.2478/prolas-2020-0047 · Cited by 15
“Depending on invasiveness, three main types of electrodes are known: extraneural, intraneural, and regenerative (Svensson et al., 2017).”
BackgroundMethodZhang, J., Chou, C.-H., Hao, M., Liang, W., Zhang, Z., Xie, A., Patton, J. L., Pei, W., & Lan, N. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3435570 · Cited by 13
“A variety of invasive and non-invasive neural techniques have been explored for communicating tactile and proprioceptive sensory information [1], [2], [3], [4], [5], [6], [7], [8], [9].”
BackgroundBiorealistic hand prosthesis with compliance control and noninvasive somatotopic sensory feedback
Lan, N., Zhang, J., Zhang, Z., Chou, C.-H., Rymer, W. Z., Niu, C. M., & Fang, P. (2023) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/acc625 · Cited by 11
“Significant advances in control and sensory feedback in bionic hands in the past few decades have been extensively reviewed elsewhere in literature [1–6].”
Resnik, L. J., Benz, H. L., Borgia, M. L., & Clark, M. A. (2019) · Expert Review of Medical Devices · doi:10.1080/17434440.2019.1619453 · Cited by 10
Ultrathin Conformable Electronic Tattoo for Tactile Sensations
Mazzotta, A., & Mattoli, V. (2023) · Advanced Electronic Materials · doi:10.1002/aelm.202201327 · Cited by 10
Kelley, M. A., Benz, H. L., Engdahl, S. M., & Bridges, J. F. P. (2019) · Expert Review of Medical Devices · doi:10.1080/17434440.2019.1626231 · Cited by 13
Modelling the compression of a soft ellipsoid fingertip
Shi, G., Shariati, A., Eames, I., & Wurdemann, H. A. (2022) · Soft Matter · doi:10.1039/d2sm00763k · Cited by 9
Sarıyıldız, E., Hanss, F., Zhou, H., Sreenivasa, M., Armitage, L., Mutlu, R., & Alıcı, G. (2023) · Sensors · doi:10.3390/s23208492 · Cited by 16
“Several other noticeable studies on hybrid feedback were introduced in a review by Svensson et al. [25].”
BackgroundPsychophysical principles of discrete event-driven vibrotactile feedback for prostheses
Karakuş, İ., & Güçlü, B. (2020) · Somatosensory & Motor Research · doi:10.1080/08990220.2020.1769055 · Cited by 10
Dosen, S. S., Prahm, C., Amsuess, S., Vujaklija, I., & Farina, D. (2021) · Springer eBooks · doi:10.1007/978-3-030-60746-3_15 · Cited by 10
Evoked Tactile Feedback and Control Scheme on Functional Utility of Prosthetic Hand
Vargas, L., Huang, H., Zhu, Y., & Hu, X. (2021) · IEEE Robotics and Automation Letters · doi:10.1109/lra.2021.3139147 · Cited by 10
Bone Conduction as Sensory Feedback Interface: A Preliminary Study
Mayer, R. M., Mohammadi, A., Alıcı, G., Choong, P., & Oetomo, D. (2019) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/embc.2019.8856424 · Cited by 11
“Invasive approaches such as implanted nerve electrodes have great potential but are only applicable and desirable to a subset of the amputees due to surgical risks for patients and potential limited lifetime of electrodes [2][4][1][5].”
BackgroundWang, H., Chai, G., Sheng, X., & Zhu, X. (2021) · International IEEE/EMBS Conference on Neural Engineering · doi:10.1109/ner49283.2021.9441192 · Cited by 10
“Nevertheless, to date, none of commercially available prostheses can provide effective somatosensory feedback to the amputee users to close the control loop[5].”
BackgroundLiu, Y., Xi, P., Li, B., Zhang, M., Liu, H., Tang, R., Shan, X., Huang, Q., He, J., Liu, Z., et al. (2022) · Journal of Neural Engineering · doi:10.1088/1741-2552/ac5bf6 · Cited by 8
Zhen, G., Chen, H., Tsai, S., Zhang, J., Chen, T., & Jia, X. (2019) · Journal of Biomedical Materials Research Part B: Applied Biomaterials · doi:10.1002/jbm.b.34135 · Cited by 7
Gholinezhad, S., Farina, D., Dosen, S. S., & Dideriksen, J. L. (2023) · Scientific Reports · doi:10.1038/s41598-023-38753-y · Cited by 9
“(6) and (9) as well as (7) and (9) we find that:”
BackgroundClosed-Loop Force Control by Biorealistic Hand Prosthesis With Visual and Tactile Sensory Feedback
Zhang, Z., Xie, A., Chou, C.-H., Liang, W., Zhang, J., Bi, S., & Lan, N. (2024) · IEEE Transactions on Neural Systems and Rehabilitation Engineering · doi:10.1109/tnsre.2024.3439722 · Cited by 8
“In general, a large variety of neural interface techniques, including invasively and/or non-invasively, have been explored to facilitate the communicating of sensory information to amputees [7], [8], [9], [10], [11].”
BackgroundApplication of EMG feedback for hand prosthesis control in high-level amputation: a case study
Tchimino, J., Hansen, R. L., Jørgensen, P. H., Dideriksen, J. L., & Dosen, S. S. (2024) · Scientific Reports · doi:10.1038/s41598-024-80828-x · Cited by 18
A Sensory Feedback Neural Stimulator Prototype for Both Implantable and Wearable Applications
Mereu, F., Cordella, F., Paolini, R., Scarpelli, A., Demofonti, A., Zollo, L., & Gruppioni, E. (2024) · Micromachines · doi:10.3390/mi15040480 · Cited by 9
“According to the reviews [4,5] sensory feedback can be categorized into substitution, modality-matched, and somatotopically matched methods.”
BackgroundWang, X., Zhang, Y., Guo, T., Wu, S., Zhong, J., Cheng, C., & Sui, X. (2024) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2024.108556 · Cited by 7
Xiong, Q., Yao, H., Wang, J., Huang, Z., Luo, J., Zhong, C., Lin, Y., & Shu, L. (2025) · Frontiers in Neuroscience · doi:10.3389/fnins.2025.1519758 · Cited by 7
“This enhances operational efficiency (Svensson et al., 2017; Dangxiao et al., 2019; Yao et al., 2022).”
Analysis of Compensatory Movements Using a Supernumerary Robotic Hand for Upper Limb Assistance
Rossero, M., Ciullo, A. S., Grioli, G., Catalano, M. G., & Bicchi, A. (2020) · Frontiers in Robotics and AI · doi:10.3389/frobt.2020.587759 · Cited by 6
Metadata
- Authors
- Svensson, P., Wijk, U., Björkman, A., & Antfolk, C.
- Affiliations
- Lund University (SE)
- Skåne University Hospital (SE)
- Corresponding author
- Antfolk, Christian
- Venue
- Expert Review of Medical Devices
- Publisher
- Informa UK Limited
- Published
- 2017-05-31
- Volume
- 14
- Issue
- 6
- Pages
- 439-447
- ISSN
- 1743-4440 (ISSN-L)
- 1745-2422
- OpenAlex
- W2619254759
- Cited by
- 192
- References
- 68
- Citations by year
- 2026: 10 · 2025: 19 · 2024: 25 · 2023: 33 · 2022: 24 · 2021: 25 · 2020: 22 · 2019: 20 · 2018: 12 · 2017: 2
- FWCI
- 1.23
- Type
- journal article
- Language
- en
- Open access
- closed
- Locations
- Expert Review of Medical Devices (publishedVersion)
- PubMed (publishedVersion)
- Lund University Publications (Lund University) (submittedVersion)
- Funders
- Swedish Research Council (637-2013-444)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Prosthetics and Rehabilitation Robotics
- Life Sciences › Neuroscience › Cognitive Neuroscience › Tactile and Sensory Interactions
- Physical Sciences › Engineering › Biomedical Engineering › Muscle activation and electromyography studies
- Keywords
- sensory feedback, upper limb prosthesis, prosthetic hand, vibrotactile feedback, electrotactile feedback, cuff electrodes, embodiment, upper limb amputees, prosthesis acceptance
- MeSH terms
- Amputees, Artificial Limbs, Body Image, Electrodes, Implanted, Hand, Humans, Prosthesis Design, Upper Extremity, Feedback, Sensory
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.