How valid are wearable physical activity trackers for measuring steps?
The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Abstract
Wearable activity trackers have become popular for tracking individual's daily physical activity, but little information is available to substantiate the validity of these devices in step counts. Thirty‐five healthy individuals completed three conditions of activity tracker measurement: walking/jogging on a treadmill, walking over‐ground on an indoor track, and a 24‐hour free‐living condition. Participants wore 10 activity trackers at the same time for both treadmill and over‐ground protocol. Of these 10 activity trackers three were randomly given for 24‐hour free‐living condition. Correlations of steps measured to steps observed were r = 0.84 and r = 0.67 on a treadmill and over‐ground protocol, respectively. The mean MAPE (mean absolute percentage error) score for all devices and speeds on a treadmill was 8.2% against manually counted steps. The MAPE value was higher for over‐ground walking (9.9%) and even higher for the 24‐hour free‐living period (18.48%) on step counts. Equivalence testing for step count measurement resulted in a significant level within ±5% for the Fitbit Zip, Withings Pulse, and Jawbone UP24 and within ±10% for the Basis B1 band, Garmin VivoFit, and SenseWear Armband Mini. The results show that the Fitbit Zip and Withings Pulse provided the most accurate measures of step count under all three different conditions (i.e. treadmill, over‐ground, and 24‐hour condition), and considerable variability in accuracy across monitors and also by speeds and conditions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The Physical Activity Guidelines for Americans
Piercy, K. L., Troiano, R. P., Ballard, R. M., Carlson, S. A., Fulton, J. E., Galuska, D. A., George, S. M., & Olson, R. D. (2018) · JAMA · doi:10.1001/jama.2018.14854 · Cited by 9,755
Validity of 10 Electronic Pedometers for Measuring Steps, Distance, and Energy Cost
CROUTER, S. E., SCHNEIDER, P. L., KARABULUT, M., & BASSETT, D. R. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000078932.61440.a2 · Cited by 899
Accuracy of Smartphone Applications and Wearable Devices for Tracking Physical Activity Data
Case, M. A., Burwick, H. A., Volpp, K. G., & Patel, M. S. (2015) · JAMA · doi:10.1001/jama.2014.17841 · Cited by 694 · cited 3×
“Few studies are available for comparison but Case et al. found that four smartphone pedometer applications had MPE scores ranging from −6.7% to 6.2% (Case et al., 2015).”
BackgroundResultInfluentialValidity of Consumer-Based Physical Activity Monitors
LEE, J.-M., KIM, Y., & WELK, G. J. (2014) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000287 · Cited by 401 · cited 3×
“Previous studies have examined the validity of these devices for estimating energy expenditure (Bai et al., 2015; Lee et al., 2014b); however, this is one of the only studies to examine the relative validity for counting steps, an outcome measure of greater interest to consumers.”
BackgroundResultSelf-citationComparison of Pedometer and Accelerometer Accuracy under Controlled Conditions
LE MASURIER, G. C., & TUDOR-LOCKE, C. (2003) · Medicine & Science in Sports & Exercise · doi:10.1249/01.mss.0000064996.63632.10 · Cited by 360 · cited 2×
“Traditional pedometers have been validated as accurate measures of step counts in controlled and free-living conditions (Le Masurier & Tudor-Locke, 2003; Wilde, Corbin, & Le Masurier, 2004), and they have been widely used in behavioural interventions (Butler, Furber, Phongsavan, Mark, & Bauman,…”
BackgroundMethodEffects of Walking on Coronary Heart Disease in Elderly Men: The Honolulu Heart Program
Hakim, A. A., Curb, J. D., Petrovitch, H., Rodriguez, B. L., Yano, K., Ross, G. W., White, L. R., & Abbott, R. D. (1999) · Circulation · doi:10.1161/01.cir.100.1.9 · Cited by 277 · cited 1×
“When active older adults were compared to those who seldom walk, they have lower blood pressure, and also had lower Body Mass Index (BMI) values (Hakim et al., 1999).”
BackgroundComparison of Step Outputs for Waist and Wrist Accelerometer Attachment Sites
TUDOR-LOCKE, C., BARREIRA, T. V., & SCHUNA, J. M. (2015) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000476 · Cited by 218
Accuracy of 2 Activity Monitors in Detecting Steps in People With Stroke and Traumatic Brain Injury
Fulk, G. D., Combs, S. A., Danks, K. A., Nirider, C. D., Raja, B., & Reisman, D. S. (2014) · Physical Therapy · doi:10.2522/ptj.20120525 · Cited by 182 · cited 2×
“Fulk et al. (2014) performed a validity study on step counts with stroke and traumatic brain injury population during a two-minute walk test (Fulk et al., 2014).”
MethodTully, M. A., McBride, C., Heron, L., & Hunter, R. F. (2014) · BMC Research Notes · doi:10.1186/1756-0500-7-952 · Cited by 172 · cited 1×
“Tully, McBride, Heron, Allen, and Hunter (2014) examined the validity of the Fitbit Zip on step counts in free-living condition for 7-day-wear period and found no significant difference between the FZ and the two reference devices (i.e. Yamax CW700, Actigraph GT3X+) (Tully et al., 2014).”
BackgroundComparison of Consumer and Research Monitors under Semistructured Settings
BAI, Y., WELK, G. J., NAM, Y. H., LEE, J. A., LEE, J.-M., KIM, Y., MEIER, N. F., & DIXON, P. M. (2016) · Medicine & Science in Sports & Exercise · doi:10.1249/mss.0000000000000727 · Cited by 149 · cited 4×
“Previous studies have examined the validity of these devices for estimating energy expenditure (Bai et al., 2015; Lee et al., 2014b); however, this is one of the only studies to examine the relative validity for counting steps, an outcome measure of greater interest to consumers.”
BackgroundResultSelf-citation
Cited by
Fuller, D., Colwell, E., Low, J., Orychock, K., Tobin, M. A., Simango, B., Buote, R., Van Heerden, D., Luan, H., Cullen, K., et al. (2020) · JMIR mHealth and uHealth · doi:10.2196/18694 · Cited by 715
“[45,50,72,79,80,88-117] Thigh or wrist Discontinued 2013 Flex Fitbit”
BackgroundInfluentialAccuracy of Fitbit Devices: Systematic Review and Narrative Syntheses of Quantitative Data
Feehan, L. M., Geldman, J., Sayre, E. C., Park, C., Ezzat, A. M., Yoo, J. Y., Hamilton, C. B., & Li, L. C. (2018) · JMIR mHealth and uHealth · doi:10.2196/10527 · Cited by 616
“Our evaluation for step count accuracy in free-living settings was consistent with those of 5 other studies examining MAPE or level-of-agreement differences in daily step measures in healthy adults for Fitbit compared with an accelerometer worn on the torso or a pedometer worn on the ankle [42,64-67].”
ResultHenriksen, A., Haugen Mikalsen, M., Woldaregay, A. Z., Muzny, M., Hartvigsen, G., Hopstock, L. A., & Grimsgaard, S. (2018) · Journal of Medical Internet Research · doi:10.2196/jmir.9157 · Cited by 542
“In 22 of the studies, one or more Garmin devices were used [32,33,46,49,50,62,77-92].”
MethodXie, J., Wen, D., Liang, L., Jia, Y., Gao, L., & Lei, J. (2018) · JMIR mHealth and uHealth · doi:10.2196/mhealth.9754 · Cited by 310
“For measuring the number of steps, Jones et al [27] evaluated the accuracies of the measurements by 10 types of wearable devices simultaneously worn by 35 subjects under three activity states and found that the measurements were most accurate on the treadmill, with a MAPE of 0.08, followed by that under the state of n…”
MethodInfluentialSember, V., Meh, K., Sorić, M., Starc, G., Rocha, P., & Jurak, G. (2020) · International Journal of Environmental Research and Public Health · doi:10.3390/ijerph17197161 · Cited by 266
Metadata
- Authors
- An, H., Jones, G. C., Kang, S., Welk, G. J., & Lee, J.
- Venue
- European Journal of Sport Science
- Publisher
- Wiley
- Published
- 2016-12-02
- Volume
- 17
- Issue
- 3
- Pages
- 360-368
- ISSN
- 1536-7290 (ISSN-L)
- 1746-1391
- OpenAlex
- W2558700065
- Cited by
- 132
- References
- 11
- FWCI
- 10.04
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: How valid are wearable physical activity trackers for measuring steps? https://app.cochat.ai/papers/10.1080/17461391.2016.1255261
- The paper
- An, H., Jones, G. C., Kang, S., Welk, G. J., & Lee, J. (2017). How valid are wearable physical activity trackers for measuring steps? European Journal of Sport Science. https://doi.org/10.1080/17461391.2016.1255261
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.