The expanding field of extracellular vesicle (EV) research needs reproducible and accurate methods to characterize single EVs. Nanoparticle Tracking Analysis (NTA) is commonly used to determine EV concentration and diameter. As the EV field is lacking methods to easily confirm and validate NTA data, questioning the reliability of measurements remains highly important. In this regard, a comparison addressing measurement quality between different NTA devices such as Malvern's NanoSight NS300 or Particle Metrix' ZetaView has not yet been conducted. To evaluate the accuracy and repeatability of size and concentration determinations of both devices, we employed comparative methods including transmission electron microscopy (TEM) and single particle interferometric reflectance imaging sensing (SP‐IRIS) by ExoView. Multiple test measurements with nanospheres, liposomes and ultracentrifuged EVs from human serum and cell culture supernatant were performed. Additionally, serial dilutions and freeze‐thaw cycle‐dependent EV decrease were measured to determine the robustness of each system. Strikingly, NanoSight NS300 exhibited a 2.0–2.1‐fold overestimation of polystyrene and silica nanosphere concentration. By measuring serial dilutions of EV samples, we demonstrated higher accuracy in concentration determination by ZetaView (% BIAS range: 2.7–8.5) in comparison with NanoSight NS300 (% BIAS range: 32.9–36.8). The concentration measurements by ZetaView were also more precise (% CV range: 0.0–4.7) than measurements by NanoSight NS300 (% CV range: 5.4–10.7). On the contrary, quantitative TEM imaging indicated more accurate EV sizing by NanoSight NS300 (% D TEM range: 79.5–134.3) compared to ZetaView (% D TEM range: 111.8–205.7), while being equally repeatable (NanoSight NS300% CV range: 0.8–6.7; ZetaView: 1.4–7.8). However, both devices failed to report a peak EV diameter below 60 nm compared to TEM and SP‐IRIS. Taken together, NTA devices differ strongly in their hardware and software affecting measuring results. ZetaView provided a more accurate and repeatable depiction of EV concentration, whereas NanoSight NS300 supplied size measurements of higher resolution.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Théry, C., Witwer, K. W., Aikawa, E., Alcaraz, M. J., Anderson, J. D., Andriantsitohaina, R., Antoniou, A., Arab, T., Archer, F., Atkin‐Smith, G. K., et al. (2018) · Journal of Extracellular Vesicles · doi:10.1080/20013078.2018.1535750 · Cited by 11,099
Self-citationShedding light on the cell biology of extracellular vesicles
van Niel, G., D'Angelo, G., & Raposo, G. (2018) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm.2017.125 · Cited by 8,369 · cited 2×
“shaped morphology of EVs [4,11] as well as being timeconsuming and technically challenging.”
BackgroundPancreatic cancer exosomes initiate pre-metastatic niche formation in the liver
Costa-Silva, B., Aiello, N. M., Ocean, A. J., Singh, S., Zhang, H., Thakur, B. K., Becker, A., Hoshino, A., Mark, M. T., Molina, H., et al. (2015) · Nature Cell Biology · doi:10.1038/ncb3169 · Cited by 2,692 · cited 1×
“The preparation of a metastatic niche in pancreatic cancer [1], the mediation of immune modulation by mesenchymal stem cells [2] or the communication between neurons and glia cells [3] are only few examples highlighting the immense impact of EVs in biomedical research.”
BackgroundLötvall, J., Hill, A. F., Hochberg, F., Buzás, E. I., Di Vizio, D., Gardiner, C., Gho, Y. S., Kurochkin, I. V., Mathivanan, S., Quesenberry, P., et al. (2014) · Journal of Extracellular Vesicles · doi:10.3402/jev.v3.26913 · Cited by 2,451
Filipe, V., Hawe, A., & Jiskoot, W. (2010) · Pharmaceutical Research · doi:10.1007/s11095-010-0073-2 · Cited by 1,885
Sizing and phenotyping of cellular vesicles using Nanoparticle Tracking Analysis
Dragovic, R. A., Gardiner, C., Brooks, A. S., Tannetta, D. S., Ferguson, D. J. P., Hole, P., Carr, B., Redman, C. W. G., Harris, A. L., Dobson, P. J., et al. (2011) · Nanomedicine: Nanotechnology, Biology and Medicine · doi:10.1016/j.nano.2011.04.003 · Cited by 1,362
EV-TRACK: transparent reporting and centralizing knowledge in extracellular vesicle research
EV-TRACK Consortium, Van Deun, J., Mestdagh, P., Agostinis, P., Akay, Ö., Anand, S., Anckaert, J., Martinez, Z. A., Baetens, T., Beghein, E., et al. (2017) · Nature Methods · doi:10.1038/nmeth.4185 · Cited by 1,284 · cited 1×
“We have submitted all relevant data of our experiments to the EV-TRACK knowledgebase (EV-TRACK ID: EV180021) [25].”
Methodvan der Pol, E., Coumans, F. A. W., Grootemaat, A. E., Gardiner, C., Sargent, I. L., Harrison, P., Sturk, A., van Leeuwen, T. G., & Nieuwland, R. (2014) · Journal of Thrombosis and Haemostasis · doi:10.1111/jth.12602 · Cited by 917
Neurotransmitter-Triggered Transfer of Exosomes Mediates Oligodendrocyte–Neuron Communication
Frühbeis, C., Fröhlich, D., Kuo, W. P., Amphornrat, J., Thilemann, S., Saab, A. S., Kirchhoff, F., Möbius, W., Goebbels, S., Nave, K.-A., et al. (2013) · PLoS Biology · doi:10.1371/journal.pbio.1001604 · Cited by 902
Extracellular vesicle sizing and enumeration by nanoparticle tracking analysis
Gardiner, C., Ferreira, Y. J., Dragovic, R. A., Redman, C. W. G., & Sargent, I. L. (2013) · Journal of Extracellular Vesicles · doi:10.3402/jev.v2i0.19671 · Cited by 584
Cited by
Welsh, J. A., Goberdhan, D. C. I., O'Driscoll, L., Buzas, E. I., Blenkiron, C., Bussolati, B., Cai, H., Di Vizio, D., Driedonks, T. A. P., Erdbrügger, U., et al. (2024) · Journal of Extracellular Vesicles · doi:10.1002/jev2.12404 · Cited by 4,663
Exosomes as a new frontier of cancer liquid biopsy
Yu, D., Li, Y., Wang, M., Gu, J., Xu, W., Cai, H., Fang, X., & Zhang, X. (2022) · Molecular Cancer · doi:10.1186/s12943-022-01509-9 · Cited by 855
Midekessa, G., Godakumara, K., Ord, J., Viil, J., Lättekivi, F., Dissanayake, K., Kopanchuk, S., Rinken, A., Andronowska, A., Bhattacharjee, S., et al. (2020) · ACS Omega · doi:10.1021/acsomega.0c01582 · Cited by 597
Ha, D. H., Kim, H.-K., Lee, J., Kwon, H. H., Park, G.-H., Yang, S. H., Jung, J. Y., Choi, H., Lee, J. H., Sung, S., et al. (2020) · Cells · doi:10.3390/cells9051157 · Cited by 539
Technologies and Standardization in Research on Extracellular Vesicles
Gandham, S., Su, X., Wood, J., Nocera, A. L., Alli, S. C., Milane, L., Zimmerman, A., Amiji, M., & Ivanov, A. R. (2020) · Trends in Biotechnology · doi:10.1016/j.tibtech.2020.05.012 · Cited by 494
The ins-and-outs of exosome biogenesis, secretion, and internalization
Arya, S. B., Collie, S. P., & Parent, C. A. (2024) · Trends in Cell Biology · doi:10.1016/j.tcb.2023.06.006 · Cited by 427
Analytical characterization of liposomes and other lipid nanoparticles for drug delivery
Fan, Y., Marioli, M., & Zhang, K. (2021) · Journal of Pharmaceutical and Biomedical Analysis · doi:10.1016/j.jpba.2020.113642 · Cited by 395
Exosome Isolation by Ultracentrifugation and Precipitation and Techniques for Downstream Analyses
Coughlan, C., Bruce, K. D., Burgy, O., Boyd, T. D., Michel, C. R., Garcia‐Perez, J. E., Adame, V., Anton, P., Bettcher, B. M., Chial, H. J., et al. (2020) · Current Protocols in Cell Biology · doi:10.1002/cpcb.110 · Cited by 335
Veerman, R. E., Teeuwen, L., Czarnewski, P., Güclüler Akpinar, G., Sandberg, A., Cao, X., Pernemalm, M., Orre, L. M., Gabrielsson, S., & Eldh, M. (2021) · Journal of Extracellular Vesicles · doi:10.1002/jev2.12128 · Cited by 327
Using single-vesicle technologies to unravel the heterogeneity of extracellular vesicles
Bordanaba-Florit, G., Royo, F., Kruglik, S. G., & Falcón-Pérez, J. M. (2021) · Nature Protocols · doi:10.1038/s41596-021-00551-z · Cited by 325
Comprehensive isolation of extracellular vesicles and nanoparticles
Zhang, Q., Jeppesen, D. K., Higginbotham, J. N., Franklin, J. L., & Coffey, R. J. (2023) · Nature Protocols · doi:10.1038/s41596-023-00811-0 · Cited by 294
Characterizing Extracellular Vesicles and Their Diverse RNA Contents
Veziroglu, E. M., & Mias, G. I. (2020) · Frontiers in Genetics · doi:10.3389/fgene.2020.00700 · Cited by 222
“Furthermore, NTA studies have reported a practical detection limit of 60–70 nm (van der Pol et al., 2014; Bachurski et al., 2019), while TEM analysis found the mode particle size of serum-derived EVs to be 50 nm (Bachurski et al.”
BackgroundMethodInfluentialWang, D., Wang, P., Bian, X., Xu, S., Zhou, Q., Zhang, Y., Ding, M., Han, M., Huang, L., Bi, J., et al. (2020) · Molecular Medicine Reports · doi:10.3892/mmr.2020.11118 · Cited by 65
Finkernagel, F., Reinartz, S., Schuldner, M., Malz, A., Jansen, J. M., Wagner, U., Worzfeld, T., Graumann, J., von Strandmann, E. P., & Müller, R. (2019) · Theranostics · doi:10.7150/thno.37549 · Cited by 55
“EVs were collected from the supernatant of ovarian cancer cells cultivated in EV-depleted medium (overnight centrifugation at 100,000 x g) using sequential ultracentrifugation [32].”
MethodSelf-citationJiang, S., Li, X., Li, Y., Chang, Z., Yuan, M., Zhang, Y., Zhu, H., Xiu, Y., Cong, H., Yin, L., et al. (2024) · Science Translational Medicine · doi:10.1126/scitranslmed.adg5116 · Cited by 30
Liang, J., Gu, S., Mao, X., Tan, Y., Wang, H., Li, S., & Zhou, Y. (2020) · Frontiers in Bioengineering and Biotechnology · doi:10.3389/fbioe.2020.00369 · Cited by 26
Metadata
- Authors
- Bachurski, D., Schuldner, M., Nguyen, P., Malz, A., Reiners, K. S., Grenzi, P. C., Babatz, F., Schauss, A. C., Hansen, H. P., Hallek, M., & von Strandmann, E. P.
- Venue
- Journal of Extracellular Vesicles
- Publisher
- Wiley
- Published
- 2019-04
- Volume
- 8
- Issue
- 1
- Pages
- 1596016-1596016
- ISSN
- 2001-3078 (ISSN-L)
- OpenAlex
- W2925523925
- Cited by
- 602
- References
- 34
- FWCI
- 15.83
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.