Microfluidic organ-on-chip technology for blood-brain barrier research
Open accessThe DOI matches its Crossref record; 61 of the 61 references it cites were found in a registry or an index.
Abstract
Organs-on-chips are a new class of microengineered laboratory models that combine several of the advantages of current in vivo and in vitro models. In this review, we summarize the advances that have been made in the development of organ-on-chip models of the blood-brain barrier (BBBs-on-chips) and the challenges that are still ahead. The BBB is formed by specialized endothelial cells and separates blood from brain tissue. It protects the brain from harmful compounds from the blood and provides homeostasis for optimal neuronal function [corrected]. Studying BBB function and dysfunction is important for drug development and biomedical research. Microfluidic BBBs-on-chips enable real-time study of (human) cells in an engineered physiological microenvironment, for example incorporating small geometries and fluid flow as well as sensors. Examples of BBBs-on-chips in literature already show the potential of more realistic microenvironments and the study of organ-level functions. A key challenge in the field of BBB-on-chip development is the current lack of standardized quantification of parameters such as barrier permeability and shear stress. This limits the potential for direct comparison of the performance of different BBB-on-chip models to each other and existing models. We give recommendations for further standardization in model characterization and conclude that the rapidly emerging field of BBB-on-chip models holds great promise for further studies in BBB biology and drug development.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Astrocyte-endothelial interactions at the blood-brain barrier
Abbott, N. J., Rönnbäck, L., & Hansson, E. (2006) · Nature Reviews Neuroscience · doi:10.1038/nrn1824 · Cited by 5,595
Reconstituting organ-level lung functions on a chip
Huh, D., Matthews, B. D., Mammoto, A., Montoya-Zavala, M., Hsin, H. Y., & Ingber, D. E. (2010) · Science · doi:10.1126/science.1188302 · Cited by 4,250 · cited 1×
“An additional example of a BBB function, which cannot be studied in Transwell, is the complex and specialized mechanism of recruitment of leukocytes at the BBB, analogous to the extravasation of leukocytes in the lungon-a-chip in case of bacterial infection.(21) In addition, the recently discovered glymphatic pathway,…”
BackgroundBhatia, S. N., & Ingber, D. E. (2014) · Nature Biotechnology · doi:10.1038/nbt.2989 · Cited by 3,305
The blood-brain barrier: Bottleneck in brain drug development
Pardridge, W. M. (2005) · NeuroRX · doi:10.1602/neurorx.2.1.3 · Cited by 2,798
TEER Measurement Techniques for In Vitro Barrier Model Systems
Srinivasan, B., Kolli, A. R., Esch, M. B., Abaci, H. E., Shuler, M. L., & Hickman, J. J. (2015) · SLAS Technology · doi:10.1177/2211068214561025 · Cited by 2,145
Kim, H. J., Huh, D., Hamilton, G., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40074j · Cited by 1,734
Can Animal Models of Disease Reliably Inform Human Studies?
van der Worp, H. B., Howells, D. W., Sena, E. S., Porritt, M. J., Rewell, S., O'Collins, V., & Macleod, M. R. (2010) · PLoS Medicine · doi:10.1371/journal.pmed.1000245 · Cited by 1,354
Blood–brain barrier structure and function and the challenges for CNS drug delivery
Abbott, N. J. (2013) · Journal of Inherited Metabolic Disease · doi:10.1007/s10545-013-9608-0 · Cited by 909
Derivation of blood-brain barrier endothelial cells from human pluripotent stem cells
Lippmann, E. S., Azarin, S. M., Kay, J. E., Nessler, R. A., Wilson, H. K., Al-Ahmad, A., Palecek, S. P., & Shusta, E. V. (2012) · Nature Biotechnology · doi:10.1038/nbt.2247 · Cited by 800
Gut-on-a-Chip microenvironment induces human intestinal cells to undergo villus differentiation
Kim, H. J., & Ingber, D. E. (2013) · Integrative Biology · doi:10.1039/c3ib40126j · Cited by 750
Characterization of a microfluidic in vitro model of the blood-brain barrier (μBBB)
Booth, R., & Kim, H. (2012) · Lab on a Chip · doi:10.1039/c2lc40094d · Cited by 739
Nedergaard, M. (2013) · Science · doi:10.1126/science.1240514 · Cited by 718
Are animal models predictive for humans?
Shanks, N., Greek, R., & Greek, J. (2009) · Philosophy, Ethics, and Humanities in Medicine · doi:10.1186/1747-5341-4-2 · Cited by 677
Preclinical research: Make mouse studies work
Perrin, S. (2014) · Nature · doi:10.1038/507423a · Cited by 668 · cited 1×
“In addition, the translation of animal models to the human clinic is difficult, evidenced by the statement that more than 80% of candidate drugs that were successfully tested in animal models failed in clinical trials.(8,9) This is partly caused by poor methodology and regulation of (some) animal experiments,(10-13) b…”
BackgroundMicroengineered physiological biomimicry: Organs-on-Chips
Huh, D., Torisawa, Y.-S., Hamilton, G. A., Kim, H. J., & Ingber, D. E. (2012) · Lab on a Chip · doi:10.1039/c2lc40089h · Cited by 667
The blood-brain barrier: an engineering perspective
Wong, A. D., Ye, M., Levy, A. F., Rothstein, J. D., Bergles, D. E., & Searson, P. C. (2013) · Frontiers in Neuroengineering · doi:10.3389/fneng.2013.00007 · Cited by 662 · cited 5×
“In addition, TEER measurements are sensitive to temperature and the ionic composition of the culture medium.(37) These factors have to be kept constant in TEER measurement protocols.”
BackgroundMethodInfluentialGriep, L. M., Wolbers, F., de Wagenaar, B., ter Braak, P. M., Weksler, B. B., Romero, I. A., Couraud, P. O., Vermes, I., van der Meer, A. D., & van den Berg, A. (2013) · Biomedical Microdevices · doi:10.1007/s10544-012-9699-7 · Cited by 537
Self-citationLippmann, E. S., Al-Ahmad, A., Azarin, S. M., Palecek, S. P., & Shusta, E. V. (2014) · Scientific Reports · doi:10.1038/srep04160 · Cited by 508 · cited 1×
“In contrast, advances have been made in deriving brain-specific endothelial cells from human induced pluripotent stem cells (hiPSC).(57,58) This development holds great promise for personalized (or precision) medicine, since brain endothelium can be derived from both “healthy” cells and “diseased” cells (e.”
BackgroundInduced pluripotent stem cells: the new patient?
Bellin, M., Marchetto, M. C., Gage, F. H., & Mummery, C. L. (2012) · Nature Reviews Molecular Cell Biology · doi:10.1038/nrm3448 · Cited by 431
Brown, J. A., Pensabene, V., Markov, D. A., Allwardt, V., Neely, M. D., Shi, M., Britt, C. M., Hoilett, O. S., Yang, Q., Brewer, B. M., et al. (2015) · Biomicrofluidics · doi:10.1063/1.4934713 · Cited by 410
Impedance-based cell monitoring: barrier properties and beyond
Benson, K., Cramer, S., & Galla, H.-J. (2013) · Fluids and Barriers of the CNS · doi:10.1186/2045-8118-10-5 · Cited by 400
Anatomy and physiology of the blood-brain barrier
Serlin, Y., Shelef, I., Knyazer, B., & Friedman, A. (2015) · Seminars in Cell & Developmental Biology · doi:10.1016/j.semcdb.2015.01.002 · Cited by 397 · cited 13×
“The gel was allowed to set for 2 hours and subsequently the device was perfused for 3 days before testing the BBB.”
BackgroundInfluentialIs There a Cerebral Lymphatic System?
Iliff, J. J., & Nedergaard, M. (2013) · Stroke · doi:10.1161/strokeaha.112.678698 · Cited by 364
SyM-BBB: a microfluidic blood brain barrier model
Prabhakarpandian, B., Shen, M.-C., Nichols, J. B., Mills, I. R., Sidoryk-Wegrzynowicz, M., Aschner, M., & Pant, K. (2013) · Lab on a Chip · doi:10.1039/c2lc41208j · Cited by 339
Hatherell, K., Couraud, P.-O., Romero, I. A., Weksler, B., & Pilkington, G. J. (2011) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2011.05.012 · Cited by 334
Organs-on-chips: breaking the in vitro impasse
Meer, A. D. V. D., & Berg, A. V. D. (2012) · Integrative Biology · doi:10.1039/c2ib00176d · Cited by 314
Westein, E., van der Meer, A. D., Kuijpers, M. J. E., Frimat, J.-P., van den Berg, A., & Heemskerk, J. W. M. (2013) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1209905110 · Cited by 304
Self-citationIn Vitro Blood–Brain Barrier Models: Current and Perspective Technologies
Naik, P., & Cucullo, L. (2012) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.23022 · Cited by 288
Li, G., Simon, M. J., Cancel, L. M., Shi, Z.-D., Ji, X., Tarbell, J. M., Morrison, B., & Fu, B. M. (2010) · Annals of Biomedical Engineering · doi:10.1007/s10439-010-0023-5 · Cited by 231
Yuan, F., Leunig, M., Berk, D. A., & Jain, R. K. (1993) · Microvascular Research · doi:10.1006/mvre.1993.1024 · Cited by 210
Measuring direct current trans-epithelial electrical resistance in organ-on-a-chip microsystems
Odijk, M., van der Meer, A. D., Levner, D., Kim, H. J., van der Helm, M. W., Segerink, L. I., Frimat, J.-P., Hamilton, G. A., Ingber, D. E., & van den Berg, A. (2015) · Lab on a Chip · doi:10.1039/c4lc01219d · Cited by 209 · cited 3×
“This can be corrected with the mathematical model presented in this publication.(53) Measuring TEER with impedance spectroscopy (using alternating currents; AC) is preferred over measuring the ohmic resistance with DC.”
BackgroundMethodOrgans-on-a-Chip: A Focus on Compartmentalized Microdevices
Moraes, C., Mehta, G., Lesher-Perez, S. C., & Takayama, S. (2012) · Annals of Biomedical Engineering · doi:10.1007/s10439-011-0455-6 · Cited by 199
Cell-Culture Models of the Blood–Brain Barrier
He, Y., Yao, Y., Tsirka, S. E., & Cao, Y. (2014) · Stroke · doi:10.1161/strokeaha.114.005427 · Cited by 194
A modular approach to create a neurovascular unit-on-a-chip
Achyuta, A. K. H., Conway, A. J., Crouse, R. B., Bannister, E. C., Lee, R. N., Katnik, C. P., Behensky, A. A., Cuevas, J., & Sundaram, S. S. (2013) · Lab Chip · doi:10.1039/c2lc41033h · Cited by 191
Wolff, A., Antfolk, M., Brodin, B., & Tenje, M. (2015) · Journal of Pharmaceutical Sciences · doi:10.1002/jps.24329 · Cited by 191
Three-Dimensional Blood-Brain Barrier Model for in vitro Studies of Neurovascular Pathology
Cho, H., Seo, J. H., Wong, K. H. K., Terasaki, Y., Park, J., Bong, K., Arai, K., Lo, E. H., & Irimia, D. (2015) · Scientific Reports · doi:10.1038/srep15222 · Cited by 184
A Novel Dynamic Neonatal Blood-Brain Barrier on a Chip
Deosarkar, S. P., Prabhakarpandian, B., Wang, B., Sheffield, J. B., Krynska, B., & Kiani, M. F. (2015) · PLOS ONE · doi:10.1371/journal.pone.0142725 · Cited by 182
Abbott, N. J. (2004) · Drug Discovery Today: Technologies · doi:10.1016/j.ddtec.2004.11.014 · Cited by 181
A versatile lab-on-a-chip tool for modeling biological barriers
Walter, F. R., Valkai, S., Kincses, A., Petneházi, A., Czeller, T., Veszelka, S., Ormos, P., Deli, M. A., & Dér, A. (2016) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2015.07.110 · Cited by 177
Son, Y. (2007) · Polymer · doi:10.1016/j.polymer.2006.11.048 · Cited by 168
Translating animal research into clinical benefit
Hackam, D. G. (2007) · BMJ · doi:10.1136/bmj.39104.362951.80 · Cited by 157
Collagen-based brain microvasculature model in vitro using three-dimensional printed template
Kim, J. A., Kim, H. N., Im, S.-K., Chung, S., Kang, J. Y., & Choi, N. (2015) · Biomicrofluidics · doi:10.1063/1.4917508 · Cited by 152
Reliable permeability assay system in a microfluidic device mimicking cerebral vasculatures
Yeon, J. H., Na, D., Choi, K., Ryu, S., Choi, C., & Park, J. (2012) · Biomedical Microdevices · doi:10.1007/s10544-012-9680-5 · Cited by 148
Flow-induced stress on adherent cells in microfluidic devices
Shemesh, J., Jalilian, I., Shi, A., Heng Yeoh, G., Knothe Tate, M. L., & Ebrahimi Warkiani, M. (2015) · Lab on a Chip · doi:10.1039/c5lc00633c · Cited by 144
Booth, R., & Kim, H. (2014) · Annals of Biomedical Engineering · doi:10.1007/s10439-014-1086-5 · Cited by 132
Sellgren, K. L., Hawkins, B. T., & Grego, S. (2015) · Biomicrofluidics · doi:10.1063/1.4935594 · Cited by 119
Biological and medical applications of a brain-on-a-chip
Pamies, D., Hartung, T., & Hogberg, H. T. (2014) · Experimental Biology and Medicine · doi:10.1177/1535370214537738 · Cited by 116
van der Meer, A. D., Poot, A. A., Feijen, J., & Vermes, I. (2010) · Biomicrofluidics · doi:10.1063/1.3366720 · Cited by 108
Self-citationTwo-Path Impedance Spectroscopy for Measuring Paracellular and Transcellular Epithelial Resistance
Krug, S. M., Fromm, M., & Günzel, D. (2009) · Biophysical Journal · doi:10.1016/j.bpj.2009.08.003 · Cited by 106
Mechanotransduction at the basis of endothelial barrier function
Gulino-Debrac, D. (2013) · Tissue Barriers · doi:10.4161/tisb.24180 · Cited by 93
Booth, R., Noh, S., & Kim, H. (2014) · Lab Chip · doi:10.1039/c3lc51304a · Cited by 87
Mechanisms of Endothelial Survival Under Shear Stress
Desai, S. Y., Marroni, M., Cucullo, L., Krizanac-Bengez, L., Mayberg, M. R., Hossain, M. T., Grant, G. G., & Janigro, D. (2002) · Endothelium · doi:10.1080/10623320212004 · Cited by 82
Shawahna, R., Declèves, X., & Scherrmann, J. (2012) · Current Drug Metabolism · doi:10.2174/1389200211309010120 · Cited by 78
Shawahna, R., Declèves, X., & Scherrmann, J. (2012) · Current Drug Metabolism · doi:10.2174/138920013804545232 · Cited by 61
Microfluidic approaches for epithelial cell layer culture and characterisation
Thuenauer, R., Rodriguez-Boulan, E. J., & Römer, W. (2014) · The Analyst · doi:10.1039/c4an00056k · Cited by 59
Gliovascular and cytokine interactions modulate brain endothelial barrier in vitro
Chaitanya, G. V., Cromer, W. E., Wells, S., Jennings, M. H., Couraud, P., Romero, I. A., Weksler, B. B., Erdreich‐Epstein, A., Mathis, J. M., Minagar, A., et al. (2011) · Journal of Neuroinflammation · doi:10.1186/1742-2094-8-162 · Cited by 44
In Vitro Models of CNS Barriers
Abbott, N. J., Dolman, D. E. M., Yusof, S. R., & Reichel, A. (2013) · AAPS advances in the pharmaceutical sciences series · doi:10.1007/978-1-4614-9105-7_6 · Cited by 39
Microengineered Vascular Systems for Drug Development
Hovell, C. M., Sei, Y. J., & Kim, Y. (2014) · SLAS TECHNOLOGY · doi:10.1177/2211068214560767 · Cited by 15
Yeste, J., Illa, X., Guimerà‐Brunet, A., & Villa, R. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2180567 · Cited by 13
van der Meer, A. D., Wolbers, F., Vermes, I., & van den Berg, A. (2014) · Royal Society of Chemistry eBooks · doi:10.1039/9781849737593-00040 · Cited by 5
Simple and stable transendothelial electrical resistance measurement in organs-on-chips
van der Helm, M. W., Odijk, M., Frimat, J. M. S., Eijkel, J. C. T., van den Berg, A., & Segerink, L. I. (2015) · University of Twente Research Information · Cited by 2
Self-citation
Cited by
Campisi, M., Shin, Y., Osaki, T., Hajal, C., Chiono, V., & Kamm, R. D. (2018) · Biomaterials · doi:10.1016/j.biomaterials.2018.07.014 · Cited by 718
Organ-on-a-Chip: A New Paradigm for Drug Development
Ma, C., Peng, Y., Li, H., & Chen, W. (2021) · Trends in Pharmacological Sciences · doi:10.1016/j.tips.2020.11.009 · Cited by 576
Herland, A., van der Meer, A. D., FitzGerald, E. A., Park, T.-E., Sleeboom, J. J. F., & Ingber, D. E. (2016) · PLOS ONE · doi:10.1371/journal.pone.0150360 · Cited by 476
Self-citationInduced pluripotent stem cells (iPSCs): molecular mechanisms of induction and applications
Cerneckis, J., Cai, H., & Shi, Y. (2024) · Signal Transduction and Targeted Therapy · doi:10.1038/s41392-024-01809-0 · Cited by 452
Development of Polymeric Nanoparticles for Blood–Brain Barrier Transfer—Strategies and Challenges
Zhang, W., Mehta, A., Tong, Z., Esser, L., & Voelcker, N. H. (2021) · Advanced Science · doi:10.1002/advs.202003937 · Cited by 430
Metadata
- Authors
- van der Helm, M. W., van der Meer, A. D., Eijkel, J. C. T., van den Berg, A., & Segerink, L. I.
- Venue
- Tissue Barriers
- Publisher
- Informa UK Limited
- Published
- 2016-01-02
- Volume
- 4
- Issue
- 1
- Pages
- e1142493
- ISSN
- 2168-8362 (ISSN-L)
- 2168-8370
- OpenAlex
- W2333671040
- Cited by
- 333
- References
- 61
- FWCI
- 15.29
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.