CoChat

The Biological Clock: The Bodyguard of Temporal Homeostasis

Perreau-Lenz, Stéphanie, Pévet, Paul, Buijs, Ruud M., Kalsbeek, Andries · 2004 · Chronobiology International
Cited by 132

The DOI matches its Crossref record; 25 of the 25 references it cites were found in a registry or an index.

Abstract

In order for any organism to function properly, it is crucial that it be table to control the timing of its biological functions. An internal biological clock, located, in mammals, in the suprachiasmatic nucleus of the hypothalamus (SCN), therefore carefully guards this temporal homeostasis by delivering its message of time throughout the body. In view of the large variety of body functions (behavioral, physiological, and endocrine) as well as the large variety in their preferred time of main activity along the light:dark cycle, it seems logical to envision different means of time distribution by the SCN. In the present review, we propose that even though it presents a unimodal circadian rhythm of general electrical and metabolic activity, the SCN seems to use several sorts of output connections that are active at different times along the light:dark cycle to control the rhythmic expression of different body functions. Although the SCN is suggested to use diffusion of synchronizing factors in the rhythmic control of behavioral functions, it also needs neuronal connections for the control of endocrine functions. The distribution of the time-of-day message to neuroendocrine systems is either directly onto endocrine neurons or via intermediate neurons located in specific SCN targets. In addition, the SCN uses its connections with the autonomic nervous system for spreading its time-of-day message, either by setting the sensitivity of endocrine glands (i.e., thyroid, adrenal, ovary) or by directly controlling an endocrine output (i.e., melatonin synthesis). Moreover, the SCN seems to use different neurotransmitters released at different times along the light:dark cycle for each of the different connection types presented. Clearly, the temporal homeostasis of endocrine functions results from a diverse set of biological clock outputs.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1081/cbi-120027984

Cites

25 of 25 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 25 references

Cited by

See all 132

Metadata

Authors
Perreau-Lenz, S., Pévet, P., Buijs, R. M., & Kalsbeek, A.
Venue
Chronobiology International
Published
2004-01
Volume
21
Issue
1
Pages
1-25
ISSN
  • 0742-0528 (ISSN-L)
  • 1525-6073
OpenAlex
W2138722562
Cited by
132
References
25
FWCI
4.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: The Biological Clock: The Bodyguard of Temporal Homeostasis. https://app.cochat.ai/papers/10.1081/cbi-120027984
The paper
Perreau-Lenz, S., Pévet, P., Buijs, R. M., & Kalsbeek, A. (2004). The Biological Clock: The Bodyguard of Temporal Homeostasis. Chronobiology International. https://doi.org/10.1081/cbi-120027984

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.