CoChat

Distributed cavity phase frequency shifts of the caesium fountain PTB-CSF2

Open access
Weyers, S, Gerginov, V, Nemitz, N, Li, R, Gibble, K · 2012 · Metrologia
Cited by 80

The DOI matches its Crossref record.

Abstract

We evaluate the frequency error from distributed cavity phase in the caesium fountain clock PTB-CSF2 at the Physikalisch-Technische Bundesanstalt with a combination of frequency measurements and ab initio calculations. The associated uncertainty is 1.3 × 10 −16 , with a frequency bias of 0.4 × 10 −16 . The agreement between the measurements and calculations explains the previously observed frequency shifts at elevated microwave amplitude. We also evaluate the frequency bias and uncertainty due to the microwave lensing of the atomic wave packets. We report a total PTB-CSF2 systematic uncertainty of 4.1 × 10 −16 .

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0026-1394/49/1/012

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

No references could be resolved yet.

Research works printed but not linked: 20

  1. Wynands R, 2005, Metrologia, 42, S64, 10.1088/0026-1394/42/3/S08 · DOI · Paper page
  2. Li R, 2010, Metrologia, 47, 534, 10.1088/0026-1394/47/5/004 · DOI
  3. 10.1103/PhysRevLett.106.130801 · DOI · Paper page
  4. Li R, 2011, Metrologia, 48, 283, 10.1088/0026-1394/48/5/007 · DOI · Paper page
  5. Li R, 2004, Metrologia, 41, 376, 10.1088/0026-1394/41/6/004 · DOI · Paper page
  6. Gerginov V, 2010, Metrologia, 47, 65, 10.1088/0026-1394/47/1/008 · DOI · Paper page
  7. 10.1109/58.990959 · DOI
  8. 10.1103/PhysRevLett.97.073002 · DOI
  9. Vanier J, 1989, The Quantum Physics of Atomic Frequency Standards, 10.1887/085274434X · DOI · Paper page
  10. Bauch A, 1998, Metrologia, 35, 829, 10.1088/0026-1394/35/6/6 · doi:10.1088/0026-1394/35/6/6
  11. Jefferts S R, 2002, Metrologia, 39, 321, 10.1088/0026-1394/39/4/1 · DOI · Paper page
  12. Li R Gibble K, 2005, Proc. Joint IEEE Int. Frequency Control Symp. and Precise Time and Time Interval Systems and Applications Meeting, 99
  13. Weyers S Wynands R Szymaniec K Chałupczak W, 2007, Proc. IEEE Int. Frequency Control Symp. and the 21st European Frequency and Time Forum, 52
  14. Gerginov V Nemitz N Griebsch D Kazda M Li R Gibble K Wynands R Weyers S, 2010, Proc. 24th European Frequency and Time Forum
  15. Guéna J Bize S Clairon A Li R Gibble K, 2011, Proc. Joint Conf. IEEE Int. Frequency Control Symp. and European Frequency and Time Forum, 61
  16. Weyers S, 2001, Metrologia, 38, 343, 10.1088/0026-1394/38/4/7 · DOI · Paper page
  17. Weyers S Bauch A Schröder R Tamm Chr, 2001, Proc. 6th Symp. on Frequency Standards and Metrology, 64
  18. Chapelet F Bize S Wolf P Santarelli G Rosenbusch P Tobar M E Laurent Ph Salomon C Clairon A, 2006, Proc. 20th European Frequency and Time Forum, 160
  19. 10.1103/PhysRevLett.89.233004 · DOI · Paper page
  20. 10.1103/PhysRevLett.98.153002 · DOI

Cited by

See all 80

Metadata

Authors
Weyers, S., Gerginov, V, Nemitz, N., Li, R., & Gibble, K.
Venue
Metrologia
Published
2011-11-28
Volume
49
Issue
1
Pages
82-87
ISSN
  • 0026-1394 (ISSN-L)
  • 1681-7575
OpenAlex
W2121157558
Cited by
80
References
0
FWCI
4.69
Type
journal article
Language
en
Open access
green

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Distributed cavity phase frequency shifts of the caesium fountain PTB-CSF2. https://app.cochat.ai/papers/10.1088/0026-1394/49/1/012
The paper
Weyers, S., Gerginov, V, Nemitz, N., Li, R., & Gibble, K. (2012). Distributed cavity phase frequency shifts of the caesium fountain PTB-CSF2. Metrologia. https://doi.org/10.1088/0026-1394/49/1/012

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.