Spectral emissivity of skin and pericardium
Open accessThe DOI matches its Crossref record; 10 of the 10 references it cites were found in a registry or an index.
Abstract
A monochromator was modified to measure the emissivity, ε(λ), of living tissue in the infrared region between 1 and 14 μm. The infrared radiation from the tissue was compared with blackbody radiation and in this way ε(λ) has been determined for white skin, black skin, burnt skin and pericardium. A compensating skin thermometer was constructed to measure the temperature of the surface of the tissue. The temperature difference before and after contact between a gold ring and the surface was made as small as possible (0.05 K). A reference radiator with the same spectral radiance (experimentally determined) mas used in compensating for the environment. It appeared that ε(λ) for skin is independent of the wavelength and equal to 0.98+-0.01. These results contradict those of Elam, Goodwin and Lloyd Williams, but are in good agreement with those of Hardy and Watmough and Oliver. In addition there was no difference between ε(λ) for normal skin and burnt skin. Epicardium values were found to lie between 0.83 (fresh heart) and 0.90 (after 7 h and after 9 d).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physiologie der Thermoreception
Hensel, H. (1952) · Ergebnisse der Physiologie Biologischen Chemie und Experimentellen Pharmakologie · doi:10.1007/bf02269025 · Cited by 190
Spectral Transmittance and Reflectance of Excised Human Skin
Hardy, J. D., Hammel, H. T., & Murgatroyd, D. (1956) · Journal of Applied Physiology · doi:10.1152/jappl.1956.9.2.257 · Cited by 166
THE RADIATION OF HEAT FROM THE HUMAN BODY
Hardy, J. D. (1934) · Journal of Clinical Investigation · doi:10.1172/jci100607 · Cited by 137
Hardy, J. D., & Muschenheim, C. (1934) · Journal of Clinical Investigation · doi:10.1172/jci100624 · Cited by 127
TEMPERATURE GRADIENTS IN THE TISSUES IN MAN
Bazett, H. C., & McGlone, B. (1927) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1927.82.2.415 · Cited by 106
THE RADIATING POWER OF HUMAN SKIN IN THE INFRA-RED
Hardy, J. D. (1939) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1939.127.3.454 · Cited by 63
Emissivity of Human Skin in the Waveband between 2µ and 6µ
WATMOUGH, D. J., & Oliver, R. (1968) · Nature · doi:10.1038/219622a0 · Cited by 33
Measurement of the Total Normal Emissivity of Skin Without The Need For Measuring Skin Temperature
Mitchell, D., Wyndham, C. H., Hodgson, T., & Nabarro, F. R. N. (1967) · Physics in Medicine and Biology · doi:10.1088/0031-9155/12/3/308 · Cited by 32
Derksen, W. L., Monahan, T. I., & Lawes, A. J. (1957) · Journal of the Optical Society of America · doi:10.1364/josa.47.000995 · Cited by 30
THE TEMPERATURE OF THE AIR IN CONTACT WITH THE SKIN
McGlone, B., & Bazett, H. C. (1927) · American Journal of Physiology-Legacy Content · doi:10.1152/ajplegacy.1927.82.2.452 · Cited by 16
Cited by
Terahertz Technology in Biology and Medicine
Siegel, P. H. (2004) · IEEE Transactions on Microwave Theory and Techniques · doi:10.1109/tmtt.2004.835916 · Cited by 1,378
Medical applications of infrared thermography: A review
Lahiri, B. B., Bagavathiappan, S., Jayakumar, T., & Philip, J. (2012) · Infrared Physics & Technology · doi:10.1016/j.infrared.2012.03.007 · Cited by 1,333
Radiative human body cooling by nanoporous polyethylene textile
Hsu, P.-C., Song, A. Y., Catrysse, P. B., Liu, C., Peng, Y., Xie, J., Fan, S., & Cui, Y. (2016) · Science · doi:10.1126/science.aaf5471 · Cited by 1,222
Infrared Thermography for Temperature Measurement and Non-Destructive Testing
Usamentiaga, R., Venegas, P., Guerediaga, J., Vega, L., Molleda, J., & Bulnes, F. (2014) · Sensors · doi:10.3390/s140712305 · Cited by 1,181
Advanced Textiles for Personal Thermal Management and Energy
Peng, Y., & Cui, Y. (2020) · Joule · doi:10.1016/j.joule.2020.02.011 · Cited by 747
Spectrally Selective Nanocomposite Textile for Outdoor Personal Cooling
Cai, L., Song, A. Y., Li, W., Hsu, P., Lin, D., Catrysse, P. B., Liu, Y., Peng, Y., Chen, J., Wang, H., et al. (2018) · Advanced Materials · doi:10.1002/adma.201802152 · Cited by 660
A dual-mode textile for human body radiative heating and cooling
Hsu, P.-C., Liu, C., Song, A. Y., Zhang, Z., Peng, Y., Xie, J., Liu, K., Wu, C.-L., Catrysse, P. B., Cai, L., et al. (2017) · Science Advances · doi:10.1126/sciadv.1700895 · Cited by 650
Classification of factors influencing the use of infrared thermography in humans: A review
Fernández-Cuevas, I., Bouzas Marins, J. C., Arnáiz Lastras, J., Gómez Carmona, P. M., Piñonosa Cano, S., García-Concepción, M. Á., & Sillero-Quintana, M. (2015) · Infrared Physics & Technology · doi:10.1016/j.infrared.2015.02.007 · Cited by 586
A reappraisal of the use of infrared thermal image analysis in medicine
Jones, B. F. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.746635 · Cited by 572
An Overview of Recent Application of Medical Infrared Thermography in Sports Medicine in Austria
Hildebrandt, C., Raschner, C., & Ammer, K. (2010) · Sensors · doi:10.3390/s100504700 · Cited by 419
Moreira, D. G., Costello, J. T., Brito, C. J., Adamczyk, J. G., Ammer, K., Bach, A. J. E., Costa, C. M. A., Eglin, C., Fernandes, A. A., Fernández-Cuevas, I., et al. (2017) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2017.07.006 · Cited by 406
Temperature Regulation in Colored Infrared-Transparent Polyethylene Textiles
Cai, L., Peng, Y., Xu, J., Zhou, C., Zhou, C., Wu, P., Lin, D., Fan, S., & Cui, Y. (2019) · Joule · doi:10.1016/j.joule.2019.03.015 · Cited by 392
Infrared-Transparent Visible-Opaque Fabrics for Wearable Personal Thermal Management
Tong, J. K., Huang, X., Boriskina, S. V., Loomis, J., Xu, Y., & Chen, G. (2015) · ACS Photonics · doi:10.1021/acsphotonics.5b00140 · Cited by 380
Miao, D., Cheng, N., Wang, X., Yu, J., & Ding, B. (2022) · Nano Letters · doi:10.1021/acs.nanolett.1c03801 · Cited by 256
Kandlikar, S. G., Perez-Raya, I., Raghupathi, P. A., Gonzalez-Hernandez, J.-L., Dabydeen, D., Medeiros, L., & Phatak, P. (2017) · International Journal of Heat and Mass Transfer · doi:10.1016/j.ijheatmasstransfer.2017.01.086 · Cited by 208
“Similar findings were also reported by Steketee [25] and Patil and Williams [26].”
ResultInfrared thermal imaging for detection of peripheral vascular disorders
Philip, J., Bagavathiappan, S., Saravanan, T., Jayakumar, T., Raj, B., Karunanithi, R., Panicker, T. M. R., Korath, M., & Jagadeesan, K. (2009) · Journal of Medical Physics · doi:10.4103/0971-6203.48720 · Cited by 204
Infrared imaging technology and biological applications
Kastberger, G., & Stachl, R. (2003) · Behavior Research Methods, Instruments, & Computers · doi:10.3758/bf03195520 · Cited by 197
“Also, organic materials, such as the thoracic cuticular surface of foraging honeybees, have emissivities between 0.955 and 0.990 (Stabentheiner & Schmaranzer, 1987), which is as close to the emissivity of a black body as that of the skin of humans or other mammals ( Steketee, 1973; Watmough & Oliver, 1968).”
BackgroundInfluentialConventional and newly developed bioheat transport models in vascularized tissues: A review
Bhowmik, A., Singh, R., Repaka, R., & Mishra, S. C. (2013) · Journal of Thermal Biology · doi:10.1016/j.jtherbio.2012.12.003 · Cited by 188
MEASUREMENT OF THE THERMAL PROPERTIES OF HUMAN SKIN. A REVIEW
Cohen, M. L. (1977) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12507965 · Cited by 179
Infrared camera assessment of skin surface temperature—Effect of emissivity
Bernard, V., Staffa, E., Mornstein, V., & Bourek, A. (2013) · Physica Medica · doi:10.1016/j.ejmp.2012.09.003 · Cited by 177
Yue, X., Zhang, T., Yang, D., Qiu, F., Wei, G., & Zhou, H. (2019) · Nano Energy · doi:10.1016/j.nanoen.2019.06.004 · Cited by 175
Radiative and convective heat transfer coefficients of the human body in natural convection
Kurazumi, Y., Tsuchikawa, T., Ishii, J., Fukagawa, K., Yamato, Y., & Matsubara, N. (2008) · Building and Environment · doi:10.1016/j.buildenv.2007.12.012 · Cited by 158
“There have been many reports on the emissivity of the human body [49–76].”
BackgroundSurvey of energy scavenging for wearable and implantable devices
Ghomian, T., & Mehraeen, S. (2019) · Energy · doi:10.1016/j.energy.2019.04.088 · Cited by 126
Dell’Isola, G. B., Cosentini, E., Canale, L., Ficco, G., & Dell’Isola, M. (2021) · Sensors · doi:10.3390/s21020346 · Cited by 101
“In fact, such measurement is particularly influenced by the unavoidable instrumental uncertainties and by the operator’s ability, but also by numerous “influence quantities”, such as (i) the emissivity and the reflection coefficient of the emitting skin surface [6]; (ii) the transmission coefficient of the medium betw…”
BackgroundWang, Q., Zhou, Y., Ghassemi, P., McBride, D., Casamento, J. P., & Pfefer, T. J. (2021) · Sensors · doi:10.3390/s22010215 · Cited by 48
Metadata
- Authors
- Steketee, J.
- Venue
- Physics in Medicine & Biology
- Publisher
- IOP Publishing
- Published
- 1973-09-01
- Volume
- 18
- Issue
- 5
- Pages
- 686-694
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W1983928519
- Cited by
- 429
- References
- 10
- FWCI
- 2.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.