Non-invasive bone biopsy: a new method to analyse and display the three-dimensional structure of trabecular bone
The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Three-dimensional structure is one of the main factors influencing the mechanical behaviour of cancellous bone. To analyse the trabecular bone structure non-destructively we used a peripheral QCT system and applied a special thin-slice technique to create high-resolution volumetric data sets serving as a basis for something we would like to call non-invasive bone biopsy. In order to obtain binary data sets, the mineralized bone in the CT volume was separated from bone marrow and muscle tissue with the help of a sophisticated three-dimensional segmentation algorithm based on the analysis of directional derivatives, which are computed from a locally approximated fit function of the original CT volume. Binary volumes including either a solid representation of trabecular plates and rods or a topological representation of the cancellous bone architecture were acquired. Such volumes can be processed non-destructively and, even more important, repetitively. By using a surface reconstruction algorithm based on interpolating triangulation it was possible to visualize the three-dimensional surface of the trabecular bone structure. The results showed that surface representation and visualization in combination with a multiple thin-slice measuring technique are valuable tools in studying three-dimensional bone architecture. In the future, the non-invasive bone biopsies will be evaluated by means of three-dimensional mechanical analysis incorporating finite element modelling and direct morphological investigations of the cancellous bone architecture for a better prediction of bone strength as an index for fracture risk or osteoporosis.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
A Computational Approach to Edge Detection
Canny, J. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767851 · Cited by 30,004
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · Proceedings of the 14th annual conference on Computer graphics and interactive techniques · doi:10.1145/37401.37422 · Cited by 10,104
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · ACM SIGGRAPH Computer Graphics · doi:10.1145/37402.37422 · Cited by 8,647
Parfitt, A. M., Mathews, C. H., Villanueva, A. R., Kleerekoper, M., Frame, B., & Rao, D. S. (1983) · Journal of Clinical Investigation · doi:10.1172/jci111096 · Cited by 1,545
A survey on image segmentation
Fu, K. S., & Mui, J. K. (1981) · Pattern Recognition · doi:10.1016/0031-3203(81)90028-5 · Cited by 1,203
The direct examination of three-dimensional bone architecture in vitro by computed tomography
Feldkamp, L. A., Goldstein, S. A., Parfitt, M. A., Jesion, G., & Kleerekoper, M. (1989) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650040103 · Cited by 1,071
Digital Step Edges from Zero Crossing of Second Directional Derivatives
Haralick, R. M. (1984) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1984.4767475 · Cited by 1,026
Torre, V., & Poggio, T. A. (1986) · IEEE Transactions on Pattern Analysis and Machine Intelligence · doi:10.1109/tpami.1986.4767769 · Cited by 989
Kleerekoper, M., Villanueva, A. R., Stanciu, J., Rao, D. S., & Parfitt, A. M. (1985) · Calcified Tissue International · doi:10.1007/bf02554913 · Cited by 695
Trabecular bone pattern factor—a new parameter for simple quantification of bone microarchitecture
Hahn, M., Vogel, M., Pompesius-Kempa, M., & Delling, G. (1992) · Bone · doi:10.1016/8756-3282(92)90078-b · Cited by 540
Cited by
Hildebrand, T., Laib, A., Müller, R., Dequeker, J., & Rüegsegger, P. (1999) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.1999.14.7.1167 · Cited by 1,303
Self-citationBoutroy, S., Bouxsein, M. L., Munoz, F., & Delmas, P. D. (2005) · The Journal of Clinical Endocrinology & Metabolism · doi:10.1210/jc.2005-1258 · Cited by 1,192
Quantification of Bone Microarchitecture with the Structure Model Index
HILDEBRAND, T., & RÜEGSEGGER, P. (1997) · Computer Methods in Biomechanics and Biomedical Engineering · doi:10.1080/01495739708936692 · Cited by 1,051
Self-citationKhosla, S., Amin, S., & Orwoll, E. (2008) · Endocrine Reviews · doi:10.1210/er.2008-0002 · Cited by 930
A microtomographic system for the nondestructive evaluation of bone architecture
Rüegsegger, P., Koller, B., & Müller, R. (1996) · Calcified Tissue International · doi:10.1007/bf02509542 · Cited by 893
Repair of bone defects using synthetic mimetics of collagenous extracellular matrices
Lutolf, M. P., Weber, F. E., Schmoekel, H. G., Schense, J. C., Kohler, T., Müller, R., & Hubbell, J. A. (2003) · Nature Biotechnology · doi:10.1038/nbt818 · Cited by 850
Self-citationTRANCE/RANKL knockout mice are protected from bone erosion in a serum transfer model of arthritis.
Pettit, A. R., Ji, H., von Stechow, D., Müller, R., Goldring, S. R., Choi, Y., Benoist, C., & Gravallese, E. M. (2001) · The American Journal of Pathology · doi:10.1016/s0002-9440(10)63016-7 · Cited by 807
“Three-dimensional visualization was performed according to a previously described method.(39) All two-dimensional slices from the three-dimensional stack of microCT images were assessed for bone erosion by two independent observers (D.”
MethodSelf-citationThree-dimensional methods for quantification of cancellous bone architecture
Odgaard, A. (1997) · Bone · doi:10.1016/s8756-3282(97)00007-0 · Cited by 777
Vahle, J. L., Sato, M., Long, G. G., Young, J. K., Francis, P. C., Engelhardt, J. A., Westmore, M. S., Ma, Y. L., & Nold, J. B. (2002) · Toxicologic Pathology · doi:10.1080/01926230252929882 · Cited by 695
Müller, R., Van Campenhout, H., Van Damme, B., Van der Perre, G., Dequeker, J., Hildebrand, T., & Rüegsegger, P. (1998) · Bone · doi:10.1016/s8756-3282(98)00068-4 · Cited by 656
Self-citationPistoia, W., van Rietbergen, B., Lochmüller, E.-M., Lill, C. A., Eckstein, F., & Rüegsegger, P. (2002) · Bone · doi:10.1016/s8756-3282(02)00736-6 · Cited by 643
Jiang, Y., Zhao, J. J., Mitlak, B. H., Wang, O., Genant, H. K., & Eriksen, E. F. (2003) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2003.18.11.1932 · Cited by 616
A comparison of micro CT with other techniques used in the characterization of scaffolds
Ho, S. T., & Hutmacher, D. W. (2006) · Biomaterials · doi:10.1016/j.biomaterials.2005.08.035 · Cited by 609
Khosla, S., Riggs, B. L., Atkinson, E. J., Oberg, A. L., McDaniel, L. J., Holets, M., Peterson, J. M., & Melton, L. J. (2006) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.050916 · Cited by 583
Meinel, L., Karageorgiou, V., Fajardo, R., Snyder, B., Shinde-Patil, V., Zichner, L., Kaplan, D., Langer, R., & Vunjak-Novakovic, G. (2004) · Annals of Biomedical Engineering · doi:10.1023/b:abme.0000007796.48329.b4 · Cited by 561
Silk implants for the healing of critical size bone defects
Meinel, L., Fajardo, R., Hofmann, S., Langer, R., Chen, J., Snyder, B., Vunjak-Novakovic, G., & Kaplan, D. (2005) · Bone · doi:10.1016/j.bone.2005.06.010 · Cited by 460
MacNeil, J. A., & Boyd, S. K. (2007) · Medical Engineering & Physics · doi:10.1016/j.medengphy.2006.11.002 · Cited by 386
Macdonald, H. M., Nishiyama, K. K., Kang, J., Hanley, D. A., & Boyd, S. K. (2011) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.171 · Cited by 375
Hofmann, S., Hagenmüller, H., Koch, A. M., Müller, R., Vunjak-Novakovic, G., Kaplan, D. L., Merkle, H. P., & Meinel, L. (2007) · Biomaterials · doi:10.1016/j.biomaterials.2006.10.019 · Cited by 349
Engineering bone‐like tissue in vitro using human bone marrow stem cells and silk scaffolds
Meinel, L., Karageorgiou, V., Hofmann, S., Fajardo, R., Snyder, B., Li, C., Zichner, L., Langer, R., Vunjak‐Novakovic, G., & Kaplan, D. L. (2004) · Journal of Biomedical Materials Research Part A · doi:10.1002/jbm.a.30117 · Cited by 349
Majumdar, S., Kothari, M., Augat, P., Newitt, D. C., Link, T. M., Lin, J. C., Lang, T., Lu, Y., & Genant, H. K. (1998) · Bone · doi:10.1016/s8756-3282(98)00030-1 · Cited by 331
High-resolution Computed Tomography for Clinical Imaging of Bone Microarchitecture
Burghardt, A. J., Link, T. M., & Majumdar, S. (2011) · Clinical Orthopaedics & Related Research · doi:10.1007/s11999-010-1766-x · Cited by 296
Finite element analysis of trabecular bone structure: a comparison of image-based meshing techniques
Ulrich, D., van Rietbergen, B., Weinans, H., & Rüegsegger, P. (1998) · Journal of Biomechanics · doi:10.1016/s0021-9290(98)00118-3 · Cited by 279
Bone Structure at the Distal Radius During Adolescent Growth
Kirmani, S., Christen, D., van Lenthe, G. H., Fischer, P. R., Bouxsein, M. L., McCready, L. K., Melton, L. J., Riggs, B. L., Amin, S., Müller, R., et al. (2009) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.081255 · Cited by 278
A synchrotron radiation microtomography system for the analysis of trabecular bone samples
Salomé, M., Peyrin, F., Cloetens, P., Odet, C., Laval-Jeantet, A.-M., Baruchel, J., & Spanne, P. (1999) · Medical Physics · doi:10.1118/1.598736 · Cited by 275
Direct mechanics assessment of elastic symmetries and properties of trabecular bone architecture
van Rietbergen, B., Odgaard, A., Kabel, J., & Huiskes, R. (1996) · Journal of Biomechanics · doi:10.1016/0021-9290(96)00093-0 · Cited by 263
Finite element models in tissue mechanics and orthopaedic implant design
Prendergast, P. (1997) · Clinical Biomechanics · doi:10.1016/s0268-0033(97)00018-1 · Cited by 255
Three-dimensional finite element modelling of non-invasively assessed trabecular bone structures
Müller, R., & Rüegsegger, P. (1995) · Medical Engineering & Physics · doi:10.1016/1350-4533(95)91884-j · Cited by 240
Liu, X. S., Zhang, X. H., Sekhon, K. K., Adams, M. F., McMahon, D. J., Bilezikian, J. P., Shane, E., & Guo, X. E. (2010) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.090822 · Cited by 231
“BS/BV was computed by dividing the trabecular bone surface (BS) by the trabecular bone volume (BV), with BS and BV determined by a triangulation approach.((27)) SMI estimates, on average, the plate versus rod characteristics of trabecular bone.”
MethodSynthetic extracellular matrices for in situ tissue engineering
Pratt, A. B., Weber, F. E., Schmoekel, H. G., Müller, R., & Hubbell, J. A. (2004) · Biotechnology and Bioengineering · doi:10.1002/bit.10897 · Cited by 230
“Three-dimensional visualizations were created using in-house software for surface triangulation and rendering (Muller et al., 1994; Muller and Ruegsegger, 1997).”
MethodA review of morphology–elasticity relationships in human trabecular bone: theories and experiments
Zysset, P. K. (2003) · Journal of Biomechanics · doi:10.1016/s0021-9290(03)00128-3 · Cited by 223
Majumdar, S., Link, T. M., Augat, P., Lin, J. C., Newitt, D., Lane, N. E., & Genant, H. K. (1999) · Osteoporosis International · doi:10.1007/s001980050221 · Cited by 188
Van Rietbergen, B., Odgaard, A., Kabel, J., & Huiskes, R. (1998) · Journal of Orthopaedic Research · doi:10.1002/jor.1100160105 · Cited by 184
Finite Element Method (FEM), Mechanobiology and Biomimetic Scaffolds in Bone Tissue Engineering
Boccaccio, A., Ballini, A., Pappalettere, C., Tullo, D., Cantore, S., & Desiate, A. (2011) · International Journal of Biological Sciences · doi:10.7150/ijbs.7.112 · Cited by 178
Ridge number density: A new parameter for in vivo bone structure analysis
Laib, A., Hildebrand, T., Häuselmann, H. J., & Rüegsegger, P. (1997) · Bone · doi:10.1016/s8756-3282(97)00205-6 · Cited by 174
Self-citationStauber, M., & Müller, R. (2006) · Bone · doi:10.1016/j.bone.2005.09.019 · Cited by 174
“Bone microarchitecture can easily be assessed in vitro by means of microcomputed tomography (μCT) [45] and in peripheral regions in vivo by quantitative-computed tomography (QCT) [32,33] and magnetic resonance imaging (MRI) [24,25,51].”
BackgroundNuzzo, S., Lafage-Proust, M. H., Martin-Badosa, E., Boivin, G., Thomas, T., Alexandre, C., & Peyrin, F. (2002) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2002.17.8.1372 · Cited by 171
“Compared with reconstruction based on serial histological sections, which is time consuming and rarely performed,(45) CT, pioneered by Feldkamp et al.,(46) appears to be a suitable method for imaging and quantifying trabecular bone microstructure in 3D(14) in animals and in humans.”
InfluentialHierarchical microimaging for multiscale analysis of large vascular networks
Heinzer, S., Krucker, T., Stampanoni, M., Abela, R., Meyer, E. P., Schuler, A., Schneider, P., & Müller, R. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.03.043 · Cited by 170
“For visualization, the data were triangulated with an extended marching cubes algorithm and surface rendered with in house software (Müller et al., 1994).”
MethodComparison of structure extraction methods for in vivo trabecular bone measurements
Laib, A., & Rüegsegger, P. (1999) · Computerized Medical Imaging and Graphics · doi:10.1016/s0895-6111(98)00071-8 · Cited by 169
Pothuaud, L., Benhamou, C. L., Porion, P., Lespessailles, E., Harba, R., & Levitz, P. (2000) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.2000.15.4.691 · Cited by 168
“Automated serial sectioning, (3) quantitative computerized tomography,((4)) microcomputed tomographic scanning, (5,6) X-ray tomographic microscopy, (7,8) or magnetic resonance imaging (9–11) are all recent techniques designed to obtain high-resolution 3D reconstruction of trabecular bone microarchitecture.”
MethodDr. Müller, R., Hildebrand, T., Häuselmann, H. J., & Rüegsegger, P. (1996) · Journal of Bone and Mineral Research · doi:10.1002/jbmr.5650111118 · Cited by 166
Self-citationZhang, X. H., Liu, X. S., Vasilic, B., Wehrli, F. W., Benito, M., Rajapakse, C. S., Snyder, P. J., & Guo, X. E. (2008) · Journal of Bone and Mineral Research · doi:10.1359/jbmr.080405 · Cited by 79
Novel method to analyze post-yield mechanical properties at trabecular bone tissue level
Carretta, R., Luisier, B., Bernoulli, D., Stüssi, E., Müller, R., & Lorenzetti, S. (2013) · Journal of the Mechanical Behavior of Biomedical Materials · doi:10.1016/j.jmbbm.2012.12.003 · Cited by 43
Self-citationCarretta, R., Stüssi, E., Müller, R., & Lorenzetti, S. (2015) · BioMed Research International · doi:10.1155/2015/457371 · Cited by 14
Self-citation
Metadata
- Authors
- Muller, R., Hildebrand, T., & Ruegsegger, P.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1994-01-01
- Volume
- 39
- Issue
- 1
- Pages
- 145-164
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2052773841
- Cited by
- 245
- References
- 26
- FWCI
- 7.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.