Abstract
In this article, we introduce a simple method to characterize optical properties and blood oxygenation in tissue using spatially resolved, steady-state reflectance. The method considers multiple source-detector separations larger than 2 cm, i.e. 20 times the optical mean free path in tissue, and makes an approximation to linearize the relationship between the separation and reflectance. Simulation results show that errors of the algorithm due to the approximation are less than 10%. Using a calibration sample, we calculate from the slope and intercept the absorption and reduced scattering coefficients, mu a and mu's, of a tissue-like solution, and experimental results confirm the usefulness of the method for quantitation of haemoglobin saturation in tissue.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Farrell, T. J., Patterson, M. S., & Wilson, B. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,378
Light scattering in lntralipid-10% in the wavelength range of 400–1100 nm
van Staveren, H. J., Moes, C. J. M., van Marie, J., Prahl, S. A., & van Gemert, M. J. C. (1991) · Applied Optics · doi:10.1364/ao.30.004507 · Cited by 1,106
Cope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
Zijlstra, W. G., Buursma, A., & Meeuwsen-van der Roest, W. P. (1991) · Clinical Chemistry · doi:10.1093/clinchem/37.9.1633 · Cited by 665
Optical properties of intralipid: A phantom medium for light propagation studies
Flock, S. T., Jacques, S. L., Wilson, B. C., Star, W. M., & van Gemert, M. J. C. (1992) · Lasers in Surgery and Medicine · doi:10.1002/lsm.1900120510 · Cited by 578
Comparison of time-resolved and -unresolved measurements of deoxyhemoglobin in brain.
Chance, B., Leigh, J. S., Miyake, H., Smith, D. S., Nioka, S., Greenfeld, R., Finander, M., Kaufmann, K., Levy, W., & Young, M. (1988) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.85.14.4971 · Cited by 464
Self-citationOptical properties of normal and diseased human breast tissues in the visible and near infrared
Peters, V. G., Wyman, D. R., Patterson, M. S., & Frank, G. L. (1990) · Physics in Medicine and Biology · doi:10.1088/0031-9155/35/9/010 · Cited by 414
Sevick, E. M., Chance, B., Leigh, J., Nioka, S., & Maris, M. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90339-u · Cited by 360
Self-citationFrequency-domain multichannel optical detector for noninvasive tissue spectroscopy and oximetry
Fantini, S. (1995) · Optical Engineering · doi:10.1117/12.183988 · Cited by 330 · cited 1×
“In recent years, NIR light in forms of pulsed, amplitude-modulated, and steady-state has been used non-invasively to study optical properties and haemoglobin saturation in tissue (Delpy et nl 1988, Tamura et a1 1990, Sevick er al 1991, Farrell et al 1992% b, Fantini et al 1995 ).”
MethodTime-resolved spectroscopy of hemoglobin and myoglobin in resting and ischemic muscle
Chance, B., Nioka, S., Kent, J., McCully, K., Fountain, M., Greenfeld, R., & Holtom, G. (1988) · Analytical Biochemistry · doi:10.1016/0003-2697(88)90076-0 · Cited by 329
Self-citationLiu, H., Chance, B., Hielscher, A. H., Jacques, S. L., & Tittel, F. K. (1995) · Medical Physics · doi:10.1118/1.597520 · Cited by 179
Self-citationOptical properties of rat liver between 350 and 2200 nm
Parsa, P., Jacques, S. L., & Nishioka, N. S. (1989) · Applied Optics · doi:10.1364/ao.28.002325 · Cited by 176
Absolute quantification of deoxyhaemoglobin concentration in tissue near infrared spectroscopy
Matcher, S. J., & Cooper, C. E. (1994) · Physics in Medicine and Biology · doi:10.1088/0031-9155/39/8/008 · Cited by 166 · cited 1×
“A recent study reports the use of water absorption as a comparison signal to quantify deoxy-haemoglobin concentration, but here one must combine this method with another technique to obtain an absolute value of haemoglobin saturation ( Matcher and Cooper 1994 ).”
MethodFarrell, T. J., Wilson, B. C., & Patterson, M. S. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/12/009 · Cited by 130
Time-resolved photon emission from layered turbid media
Hielscher, A. H., Liu, H., Chance, B., Tittel, F. K., & Jacques, S. L. (1996) · Applied Optics · doi:10.1364/ao.35.000719 · Cited by 91
Self-citationAn oxidative defect in metabolic myopathies: Diagnosis by noninvasive tissue oximetry
Bank, W., & Chance, B. (1994) · Annals of Neurology · doi:10.1002/ana.410360606 · Cited by 86
Self-citationCope, M., van der Zee, P., Essenpreis, M., Arridge, S. R., & Delpy, D. T. (1991) · SPIE Proceedings · doi:10.1117/12.44196 · Cited by 76
A dynamic phantom brain model for near-infrared spectroscopy
Kurth, C. D., Liu, H., Thayer, W. S., & Chance, B. (1995) · Physics in Medicine and Biology · doi:10.1088/0031-9155/40/12/006 · Cited by 56
Self-citationFerrari, M., Zanette, E. M., Giannini, I., Sideri, G., Fieschi, C., & Carpi, A. (1986) · Advances in experimental medicine and biology · doi:10.1007/978-1-4684-5188-7_28 · Cited by 55
Cited by
Strangman, G., Culver, J. P., Thompson, J. H., & Boas, D. A. (2002) · NeuroImage · doi:10.1006/nimg.2002.1227 · Cited by 1,415
Self-citationDiffuse reflectance spectroscopy of human adenomatous colon polyps in vivo
Zonios, G., Perelman, L. T., Backman, V., Manoharan, R., Fitzmaurice, M., Van Dam, J., & Feld, M. S. (1999) · Applied Optics · doi:10.1364/ao.38.006628 · Cited by 534
Mourant, J. R., Fuselier, T., Boyer, J., Johnson, T. M., & Bigio, I. J. (1997) · Applied Optics · doi:10.1364/ao.36.000949 · Cited by 529
Wang, X., Xie, X., Ku, G., Wang, L. V., & Stoica, G. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2192804 · Cited by 505
A review of in‐vivo optical properties of human tissues and its impact on PDT
Sandell, J. L., & Zhu, T. C. (2011) · Journal of Biophotonics · doi:10.1002/jbio.201100062 · Cited by 384
Metadata
- Authors
- Liu, H., Boas, D. A., Zhang, Y., Yodh, A. G., & Chance, B.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1995-11-01
- Volume
- 40
- Issue
- 11
- Pages
- 1983-1993
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2047379477
- Cited by
- 167
- References
- 21
- FWCI
- 4.52
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.