Optical pathlength measurements on adult head, calf and forearm and the head of the newborn infant using phase resolved optical spectroscopy
Open accessThe DOI matches its Crossref record; 21 of the 21 references it cites were found in a registry or an index.
Abstract
We have used an intensity modulated optical spectrometer, which measures the phase shift across tissue experienced by intensity modulated near-infrared light, to determine the absolute optical pathlength through tissue. The instrument is portable and takes only 5 s to record pathlength at four wavelengths (690 nm, 744 nm, 807 nm and 832 nm). The absolute pathlength divided by the known spacing between the light source and detector on the skin is the differential pathlength factor (DPF) which previous studies have shown is approximately constant for spacings greater than 2.5 cm. DPF results are presented for measurements on 100 adults and 35 newborn infants to determine the statistical variation on the DPF. All measurements were made at a frequency of 200 MHz with source-detector spacings of > 4 cm. Results at 807 nm show a DPF of 4.16(+/- 18.8%) for adult arm, 5.51(+/- 18%) for adult leg, 6.26(+/- 14.1%) for adult head and 4.99(+/- 9%) for the head of a newborn infant. A wavelength dependence was obtained for DPF on all tissues and a difference in DPF between male and female was observed for both the adult arm and leg. The results can be used to improve the quantitation of chromophore concentration changes in adults and newborn infants.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Jöbsis, F. F. (1977) · Science · doi:10.1126/science.929199 · Cited by 3,899
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245
Self-citationCope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
Self-citationWyatt, J. S., Delpy, D. T., Cope, M., Wray, S., & Reynolds, E. O. R. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90467-8 · Cited by 876
Self-citationArridge, S. R., Cope, M., & Delpy, D. T. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/005 · Cited by 595
Self-citationRecovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528
Refractive index of some mammalian tissues using a fiber optic cladding method
Bolin, F. P., Preuss, L. E., Taylor, R. C., & Ference, R. J. (1989) · Applied Optics · doi:10.1364/ao.28.002297 · Cited by 522
Quantitation of cerebral blood volume in human infants by near-infrared spectroscopy
Wyatt, J. S., Cope, M., Delpy, D. T., Richardson, C. E., Edwards, A. D., Wray, S., & Reynolds, E. O. (1990) · Journal of Applied Physiology · doi:10.1152/jappl.1990.68.3.1086 · Cited by 442
Self-citationvan der Zee, P., Cope, M., Arridge, S. R., Essenpreis, M., Potter, L. A., Edwards, A. D., Wyatt, J. S., McCormick, D. C., Roth, S. C., Reynolds, E. O. R., et al. (1992) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4615-3404-4_17 · Cited by 427
Self-citationCOTSIDE MEASUREMENT OF CEREBRAL BLOOD FLOW IN ILL NEWBORN INFANTS BY NEAR INFRARED SPECTROSCOPY
Edwards, A. D., Richardson, C., Cope, M., Wyatt, J. S., Delpy, D. T., & Reynolds, E. O. R. (1988) · The Lancet · doi:10.1016/s0140-6736(88)92418-x · Cited by 370
Self-citationQuantification of adult cerebral hemodynamics by near-infrared spectroscopy
Elwell, C. E., Cope, M., Edwards, A. D., Wyatt, J. S., Delpy, D. T., & Reynolds, E. O. (1994) · Journal of Applied Physiology · doi:10.1152/jappl.1994.77.6.2753 · Cited by 219
Self-citationSpectral dependence of temporal point spread functions in human tissues
Essenpreis, M., Elwell, C. E., Cope, M., van der Zee, P., Arridge, S. R., & Delpy, D. T. (1993) · Applied Optics · doi:10.1364/ao.32.000418 · Cited by 195
Self-citationMeasurement of Optical Path Length for Cerebral Near-Infrared Spectroscopy in Newborn Infants
Wyatt, J. S., Cope, M., Delpy, D. T., van der Zee, P., Arridge, S., Edwards, A. D., & Reynolds, E. O. R. (1990) · Developmental Neuroscience · doi:10.1159/000111843 · Cited by 182
Self-citationWyatt, J. S., Edwards, A. D., Azzopardi, D., & Reynolds, E. O. (1989) · Archives of Disease in Childhood · doi:10.1136/adc.64.7_spec_no.953 · Cited by 173
Near-infrared spectroscopy in peripheral vascular disease
Cheatle, T. R., Potter, L. A., Cope, M., Delpy, D. T., Smith, P. D. C., & Scurr, J. H. (1991) · Journal of British Surgery · doi:10.1002/bjs.1800780408 · Cited by 157
Self-citationTime-resolved spectroscopy of the human forearm
Ferrari, M., Wei, Q., Carraresi, L., Blasi, R. A. D., & Zaccanti, G. (1992) · Journal of Photochemistry and Photobiology B Biology · doi:10.1016/1011-1344(92)80005-g · Cited by 138
Chance, B., Maris, M. B., Sorge, J., & Zhang, M. Z. (1990) · SPIE Proceedings · doi:10.1117/12.17711 · Cited by 94
The Effect of Optode Positioning on Optical Pathlength in Near Infrared Spectroscopy of Brain
van der Zee, P., Arridge, S., Cope, M., & Delpy, D. T. (1990) · Advances in experimental medicine and biology · doi:10.1007/978-1-4684-8181-5_11 · Cited by 62
Self-citationDuncan, A., Whitlock, T. L., Cope, M., & Delpy, D. T. (1993) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.154641 · Cited by 58
Self-citationQuantitation of Pathlength in Optical Spectroscopy
Delpy, D. T., Arridge, S., Cope, M., Edwards, D., Reynolds, E. O. R., Richardson, C. E., Wray, S., Wyatt, J. S., & van der Zee, P. (1989) · Advances in experimental medicine and biology · doi:10.1007/978-1-4684-5643-1_5 · Cited by 55
Self-citationFirbank, M. (1994) · UCL Discovery (University College London) · Cited by 25
Cited by
Ferrari, M., & Quaresima, V. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.03.049 · Cited by 2,274
“The instrument developed at the University College Londonwas utilized tomeasure the optical pathlength on newborn and adult head (Duncan et al., 1995); the instruments developed at Urbana-Champaign and Philadelphia were utilized also tomeasure for the first time O2Hb saturation on adult PFC (De Blasi et al.”
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618
Strangman, G., Culver, J. P., Thompson, J. H., & Boas, D. A. (2002) · NeuroImage · doi:10.1006/nimg.2002.1227 · Cited by 1,415
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Metadata
- Authors
- Duncan, A., Meek, J. H., Clemence, M., Elwell, C. E., Tyszczuk, L., Cope, M., & Delpy, D.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1995-02-01
- Volume
- 40
- Issue
- 2
- Pages
- 295-304
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2114510322
- Cited by
- 649
- References
- 21
- FWCI
- 15.62
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.