Non-invasive optical monitoring of the newborn piglet brain using continuous-wave and frequency-domain spectroscopy
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
We have used continuous-wave (CW) and frequency-domain spectroscopy to investigate the optical properties of the newborn piglet brain in vivo and non-invasively. Three anaesthetized, intubated, ventilated and instrumented newborn piglets were placed into a stereotaxic instrument for optimal experimental stability, reproducible probe-to-scalp optical contact and 3D adjustment of the optical probe. By measuring the absolute values of the brain absorption and reduced scattering coefficients at two wavelengths (758 and 830 nm), frequency-domain spectroscopy provided absolute readings (in contrast to the relative readings of CW spectroscopy) of cerebral haemoglobin concentration and saturation during experimentally induced perturbations in cerebral haemodynamics and oxygenation. Such perturbations included a modulation of the inspired oxygen concentration, transient brain asphyxia, carotid artery occlusion and terminal brain asphyxia. The baseline cerebral haemoglobin saturation and concentration, measured with frequency-domain spectroscopy, were about 60% and 42 microM respectively. The cerebral saturation values ranged from a minimum of 17% (during transient brain asphyxia) to a maximum of 80% (during recovery from transient brain asphyxia). To analyse the CW optical data, we have (a) derived a mathematical relationship between the cerebral optical properties and the differential pathlength factor and (b) introduced a method based on the spatial dependence of the detected intens…
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This result is somehow expected since the assumption of fixed scattering heavily affects the hemoglobin concentrations absolute values (Fantini et al. 1999).”
From Validation of a novel wearable, wireless technology to estimate oxygen levels and lactate threshold power in the exercising muscle (2018) · cites this paper as Fantini et al. 1999
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245 · cited 2×
“The DPF is a parameter that takes into account the increased photon pathlength caused by multiple light scattering in tissues ( Delpy et al 1988, Cope et al 1991).”
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087 · cited 2×
“…≡ 〈L〉 r ∼= v〈t〉 r = v r ∫ ∞ 0 tGseminf(r, t) dt∫ ∞ 0 Gseminf(r, t) dt = √ 3μ′s 2√μa0 r √ 3μa0μ′s r √ 3μa0μ′s + 1 (10) where 〈t〉 is the average photon time of flight and the semi-infinite medium Green function Gseminf(r, t) is ∝ t−5/2 exp[−3μ′sr2/(4vt) − μavt] (Patterson et al 1989).”
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618 · cited 2×
“…Edwards et al 1988) and in adults to quantify cerebral hemodynamics (Elwell et al 1994), to monitor brain activity (Gratton et al 1995, Meek et al 1995, Wenzel et al 1996, Tamura et al 1997, Villringer and Chance 1997) and to detect intracranial haematomas (Gopinath et al 1993, Hennes et al 1999).”
Farrell, T. J., Patterson, M. S., & Wilson, B. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,378
Cope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
The composition of body tissues
Woodard, H. Q., & White, D. R. (1986) · The British Journal of Radiology · doi:10.1259/0007-1285-59-708-1209 · Cited by 764
Arridge, S. R., Cope, M., & Delpy, D. T. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/005 · Cited by 595 · cited 1×
“(8) This approach to finding the DPF is equivalent to the definition (Cope et al 1991, Arridge et al 1992) DPF ≡ 1 r ∂A ∂μa ∣∣∣∣ μa0 (9) where A is the optical attenuation defined as ln (dc(0)/dc(t)).”
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528 · cited 1×
“…Ltd 1543 oxygenation during ischaemia (Hampson and Piantadosi 1988, Ferrari et al 1992, Sahlin 1992, Fantini et al 1995, Miwa et al 1995) or exercise (Chance et al 1992, Belardinelli et al 1995, Hamaoka et al 1996, Franceschini et al 1997, Quaresima et al 1998), the assessment of the local blood…”
van der Zee, P., Cope, M., Arridge, S. R., Essenpreis, M., Potter, L. A., Edwards, A. D., Wyatt, J. S., McCormick, D. C., Roth, S. C., Reynolds, E. O. R., et al. (1992) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4615-3404-4_17 · Cited by 427 · cited 2×
“Since there are no published DPF values for the piglet brain, previous studies on piglets have assumed values of 3.85 (Brun et al 1997) or 4.39 (Stankovic et al 1998), which are values reported for the brain of newborn infants (Wyatt et al 1990, Van der Zee et al 1992).”
InfluentialCOTSIDE MEASUREMENT OF CEREBRAL BLOOD FLOW IN ILL NEWBORN INFANTS BY NEAR INFRARED SPECTROSCOPY
Edwards, A. D., Richardson, C., Cope, M., Wyatt, J. S., Delpy, D. T., & Reynolds, E. O. R. (1988) · The Lancet · doi:10.1016/s0140-6736(88)92418-x · Cited by 370 · cited 1×
“…spectroscopy has also been non-invasively applied to the human infant’s brain to measure cerebral oxygenation and hemodynamics (Cope and Delpy 1988, Edwards et al 1988) and in adults to quantify cerebral hemodynamics (Elwell et al 1994), to monitor brain activity (Gratton et al 1995, Meek et al…”
Cited by
Items 101–200 of 298
Hyperspectral image reconstruction for diffuse optical tomography
Larusson, F., Fantini, S., & Miller, E. L. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.000946 · Cited by 32
Self-citationZhang, G. C., Katz, A., Alfano, R. R., Kofinas, A. D., Kofinas, D. A., Stubblefield, P. G., Rosenfeld, W., Beyer, D., Maulik, D., & Stankovic, M. R. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/11/303 · Cited by 31
“Three basic types of optical instruments have been used for the purpose of physiological studies: continuous wave (CW) (Stankovic et al 1998b, Tsuji et al 1998, Fantini et al 1999), time-domain (Alfano et al 1998, Benaron et al 1997, Delpy et al 1988) and frequency-domain (FD) (Fantini et al 1999).”
BackgroundMethodInfluentialSelf-citationMeng, L., Mantulin, W. W., Alexander, B. S., Cerussi, A. E., Tromberg, B. J., Yu, Z., Laning, K., Kain, Z. N., Cannesson, M. P., & Gelb, A. W. (2012) · Canadian Journal of Anesthesia/Journal canadien d anesthésie · doi:10.1007/s12630-011-9662-8 · Cited by 31
Elliott, J. T., Milej, D. F., Gerega, A., Weigl, W., Diop, M., Morrison, L. B., Lee, T., Liebert, A., & Lawrence, K. S. (2013) · Biomedical Optics Express · doi:10.1364/boe.4.000206 · Cited by 31
Cerussi, A. E., Woerkom, R. V., Waffarn, F., & Tromberg, B. J. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2080102 · Cited by 31
Wallois, F., Patil, A., Kongolo, G., Goudjil, S., & Grebe, R. (2009) · Neurophysiologie Clinique · doi:10.1016/j.neucli.2009.08.001 · Cited by 31
Applications of near-infrared spectroscopy in neurocritical care
Thomas, R. E., Shin, S. S., & Balu, R. (2023) · Neurophotonics · doi:10.1117/1.nph.10.2.023522 · Cited by 30
“In addition, at the modulation frequencies typically used in FD-NIRS (<150 MHz), recorded signals are less susceptible to ambient light, minimizing background artifacts.(57,59,60) This may be particularly advantageous in the ICU where there are numerous potential artifacts from room lighting Thomas, Shin, and Balu: Ap…”
BackgroundMethodOptical Properties of Brain Tissue
Madsen, S. J., & Wilson, B. C. (2012) · Springer eBooks · doi:10.1007/978-1-4614-4978-2_1 · Cited by 30
Broadband Diffuse Optical Spectroscopic Imaging
Tromberg, B. J., Cerussi, A. E., Chung, S.-H., Tanamai, W., & Durkin, A. F. (2011) · CRC Press eBooks · doi:10.1201/b10951-13 · Cited by 29
Pal, U. M., Vishnu, G. K. A., Gogoi, G., Rila, S., Shroff, S., Gokul, A. M., Borah, P., Varma, M. M., Kurpad, V., Baruah, D. K., et al. (2020) · IEEE Transactions on Biomedical Circuits and Systems · doi:10.1109/tbcas.2020.3005971 · Cited by 28
Kusaka, T., Isobe, K., Nagano, K., Okubo, K., Yasuda, S., Kondo, M., Itoh, S., Hirao, K., & Onishi, S. (2002) · Comparative Biochemistry and Physiology Part A Molecular & Integrative Physiology · doi:10.1016/s1095-6433(01)00538-4 · Cited by 28
Blood oxygenation changes resulting from trains of low frequency transcranial magnetic stimulation
Thomson, R. H., Maller, J. J., Daskalakis, Z. J., & Fitzgerald, P. B. (2011) · Cortex · doi:10.1016/j.cortex.2011.04.028 · Cited by 27
Liu, X., Gu, Y., Huang, C., Zhao, M., Cheng, Y., Jawdeh, E. G. A., Bada, H. S., Chen, L., & Yu, G. (2021) · Journal of Biomedical Optics · doi:10.1117/1.jbo.26.1.012705 · Cited by 27
Blood oxygenation changes resulting from suprathreshold transcranial magnetic stimulation
Thomson, R. H., Maller, J. J., Daskalakis, Z. J., & Fitzgerald, P. B. (2010) · Brain stimulation · doi:10.1016/j.brs.2010.10.003 · Cited by 27
Real-time motion artifact removal using a dual-stage median filter
Huang, R., Qing, K., Yang, D., & Hong, K. (2021) · Biomedical Signal Processing and Control · doi:10.1016/j.bspc.2021.103301 · Cited by 26
Demel, A., Feilke, K., Wolf, M., Poets, C. F., & Franz, A. R. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.1.017004 · Cited by 26
Bluestone, A. Y., Stewart, M., Lei, B., Kass, I. S., Lasker, J., Abdoulaev, G. S., & Hielscher, A. H. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1784472 · Cited by 26
Peripheral oxygenation and management in the perinatal period
Weindling, A. M. (2010) · Seminars in Fetal and Neonatal Medicine · doi:10.1016/j.siny.2010.03.005 · Cited by 26
Demel, A., Wolf, M., Poets, C. F., & Franz, A. R. (2014) · BMC Pediatrics · doi:10.1186/1471-2431-14-206 · Cited by 25
“Light intensity and phase shift are recorded for each emitter-optode distance using the proprietary software package OxiTS, and the absolute μa and μs’ are calculated based on the slope of the respective regression lines at each wavelength using the diffusion equation for homogeneous, semi-infinite media [1,2].”
MethodWolf, U., Wolf, M., Choi, J. H., Paunescu, L. A., Michalos, A., & Gratton, E. (2007) · Journal of Vascular and Interventional Radiology · doi:10.1016/j.jvir.2007.06.004 · Cited by 25
“—The absolute values for absorption, scattering, and DPF were calculated (29,31) in three center regions according to the sensor (Fig 1) and the frequency-domain equations.”
MethodSelf-citationMulti-Distance Frequency-Domain Optical Measurements of Coherent Cerebral Hemodynamics
Blaney, G. P., Sassaroli, A., Pham, T., Krishnamurthy, N., & Fantini, S. (2019) · Photonics · doi:10.3390/photonics6030083 · Cited by 25
Self-citationThomson, R. H., Daskalakis, Z. J., & Fitzgerald, P. B. (2010) · Clinical Neurophysiology · doi:10.1016/j.clinph.2010.08.003 · Cited by 25
“(10) from Fantini et al. (1999): DPF ¼ ffiffiffiffiffiffiffiffi 3l0s p 2 ffiffiffiffiffilap ! r ffiffiffiffiffiffiffiffiffiffiffiffiffi 3lal0s p r ffiffiffiffiffiffiffiffiffiffiffiffiffi 3lal0s p þ 1 !”
BackgroundMethodKao, T.-C., & Sung, K. (2022) · Journal of Biomedical Optics · doi:10.1117/1.jbo.27.8.083021 · Cited by 24
Dong, L., Kudrimoti, M. R., Irwin, D., Chen, L., Kumar, S. S., Shang, Y., Huang, C., Johnson, E. L., Stevens, S. D., Shelton, B. J., et al. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.8.085004 · Cited by 24
“condition ρ√3μaμs ′ ≫ 1, which can be satisfied in practical application [129].”
Lee, I., Kim, D., Kim, S., Kim, H. J., Chung, U., & Lee, J. J. (2023) · Frontiers in Aging Neuroscience · doi:10.3389/fnagi.2023.1168815 · Cited by 22
Multi-Channel-Based Differential Pathlength Factor Estimation for Continuous-Wave fNIRS
Huang, R., & Hong, K. (2021) · IEEE Access · doi:10.1109/access.2021.3063120 · Cited by 22
“In frequency-domain fNIRS systems, a diffusion approximation of the Boltzmann transport equation has been developed [20]–[22].”
BackgroundJakubowski, D. B., Bevilacqua, F. P., Merritt, S. I., Cerussi, A. E., & Tromberg, B. J. (2009) · Oxford University Press eBooks · doi:10.1093/oso/9780195150445.003.0012 · Cited by 22
Applegate, M. B., Gómez, C. A., & Roblyer, D. M. (2021) · Journal of Biomedical Optics · doi:10.1117/1.jbo.26.3.036007 · Cited by 22
A noninvasive multimodal technique to monitor brain tumor vascularization
Saxena, V., González-Gómez, I., & Laug, W. E. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/17/013 · Cited by 21
Optical Detection of Tumors In Vivo by Visible Light Tissue Oximetry
Maxim, P. G., Carson, J. J. L., Benaron, D. A., Loo, B. W., Xing, L., Boyer, A. L., & Friedland, S. (2005) · Technology in Cancer Research & Treatment · doi:10.1177/153303460500400301 · Cited by 21
Yang, R., Brugniaux, J. V., Dhaliwal, H., Beaudin, A. E., Eliasziw, M., Poulin, M. J., & Dunn, J. F. (2015) · Physiological Reports · doi:10.14814/phy2.12378 · Cited by 20
“NIRS uses the principles of the Beer–Lambert law and the different absorption spectra of oxyhemoglobin (HbO2) and deoxyhemoglobin (HHb) to determine their respective concentrations within microvessels and tissues of the brain (Fantini et al. 1999).”
BackgroundMethodInfluentialBiomedical and atmospheric applications of optical spectroscopy in scattering media
Swartling, J. (2002) · Lund University Publications (Lund University) · Cited by 20
Stankovic, M. R., Maulik, D., Rosenfeld, W., Stubblefield, P. G., Kofinas, A. D., Gratton, E., Franceschini, M. A., Fantini, S., & Hueber, D. M. (2000) · The Journal of Maternal-Fetal & Neonatal Medicine · doi:10.3109/14767050009053440 · Cited by 20
“This animal model has been used previously for magnetic resonance [25] and optical imaging studies [10,19,26].”
BackgroundMethodInfluentialSelf-citationNoninvasive optical cytochrome c oxidase redox state measurements using diffuse optical spectroscopy
Lee, J., Kim, J. G., Mahon, S. B., Mukai, D. S., Yoon, D. S., Boss, G. R., Patterson, S. E., Rockwood, G. A., Isom, G. E., & Brenner, M. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.5.055001 · Cited by 20
“DPFs are estimated using the baseline absorption and reduced scattering coefficients and the equation described by Fantini et al.(46) The distance Table 2 Physiological values of control animals (n 1⁄4 5).”
MethodD'Arceuil, H. E., Hotakainen, M., Liu, C. H., Themelis, G., de Crespigny, A. J., & Franceschini, M. A. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1852554 · Cited by 19
Self-citationDesign of a source–detector array for dual-slope diffuse optical imaging
Blaney, G. P., Sassaroli, A., & Fantini, S. (2020) · Review of Scientific Instruments · doi:10.1063/5.0015512 · Cited by 19
Self-citationKo, T. S., Catenaccio, E., Shin, S. S., Stern, J. A., Massey, S. L., Kilbaugh, T. J., & Hwang, M. (2023) · Neurocritical Care · doi:10.1007/s12028-023-01690-9 · Cited by 19
Dual-slope imaging of cerebral hemodynamics with frequency-domain near-infrared spectroscopy
Blaney, G. P., Fernandez, C. M., Sassaroli, A., & Fantini, S. (2023) · Neurophotonics · doi:10.1117/1.nph.10.1.013508 · Cited by 19
Self-citationAge effects on brain oxygenation during hypercapnia
Gatto, R. G., Hoffman, W. E., Mueller, M., Paisansathan, C., & Charbel, F. T. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804705 · Cited by 19
“tissue in absolute concentration mol/L .(9) Eight laser diodes were coupled to the oximeter by optical fibers that emitted light at wavelengths of either 690 or 830 nm and one detector.”
BackgroundMethodIntensity dependent repetitive transcranial magnetic stimulation modulation of blood oxygenation
Thomson, R. H., Rogasch, N. C., Maller, J. J., Daskalakis, Z. J., & Fitzgerald, P. B. (2011) · Journal of Affective Disorders · doi:10.1016/j.jad.2011.08.005 · Cited by 18
“The Differential Pathlength Factor (DPF) and change in absorption were calculated from the AC and phase (Fantini et al., 1999) and changes in HbOwere then calculated with the extinction coefficients corresponding to the selected wavelengths (Toronov et al., 2001).”
MethodFeasibility of spatial frequency-domain imaging for monitoring palpable breast lesions
Robbins, C. M., Raghavan, G., Antaki, J. F., & Kainerstorfer, J. M. (2017) · Journal of Biomedical Optics · doi:10.1117/1.jbo.22.12.121605 · Cited by 18
Toya, T., Fujita, T., Fukushima, S., Shimahara, Y., Kume, Y., Yamashita, K., Matsumoto, Y., Kawamoto, N., & Kobayashi, J. (2018) · Journal of Artificial Organs · doi:10.1007/s10047-018-1057-y · Cited by 17
Parametric level set reconstruction methods for hyperspectral diffuse optical tomography
Larusson, F., Fantini, S., & Miller, E. L. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.001006 · Cited by 17
Self-citationTime-Resolved Measurements of in vivo Optical Properties of Piglet Brain
Sassaroli, A., Martelli, F., Tanikawa, Y., Tanaka, K., Araki, R., Onodera, Y., & Yamada, Y. (2000) · Optical Review · doi:10.1007/s10043-000-0420-3 · Cited by 17
Zhang, Z., Qi, M., Hügli, G., & Khatami, R. (2021) · Journal of Medical Internet Research · doi:10.2196/24171 · Cited by 16
“The robustness, precision, and accuracy of measuring HbO2, HHb, and StO2 of the Imagent system used in this study have been well validated in different physical blood-lipid models [45,58,61] and in vivo studies [59,62-64].”
BackgroundMethodLin, Y., Li, T., Shang, Y., He, L., Huang, C., Szabunio, M. M., & Yu, G. (2014) · Biomedical optics · doi:10.1364/biomed.2014.bm3a.69 · Cited by 16
Shang, Y., Lin, Y., Henry, B., Cheng, R., Huang, C., Chen, L., Shelton, B. J., Swartz, K. R., Salles, S. S., & Yu, G. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.10.105002 · Cited by 16
Zou, F., Jin, C., Ross, R. R., & Soller, B. R. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000748 · Cited by 16
Ruan, Z., Li, T., Ren, R., Zhao, Y., Li, K., Mao, Y. F., Shen, G., & Jiang, L. (2015) · Genetics and Molecular Research · doi:10.4238/2015.march.31.23 · Cited by 16
“The calculation module converts the collected data of original light intensity changes into the data of local tissue blood oxygen saturation, using an algorithm based on the methods of Fantini (Fantini et al., 1999; Hueber et al., 1999 ) and Liu (Liu et al., 1995).”
MethodMonitoring Diabetic Wound Healing by NIR Spectroscopy
Papazoglou, E. S., Zubkov, L. A., Zhu, L., Weingarten, M. S., Tyagi, S., & Pourrezaei, K. (2005) · Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC) · doi:10.1109/iembs.2005.1616030 · Cited by 16
“[5-9] We developed a fast, non-invasive, portable, and inexpensive diagnostic device based on DOT assess the state of a wound.”
MethodKo, T. S., Mavroudis, C. D., Morgan, R. W., Baker, W. B., Marquez, A. M., Boorady, T. W., Devarajan, M., Lin, Y., Roberts, A. L., Landis, W. P., et al. (2021) · Scientific Reports · doi:10.1038/s41598-021-83270-5 · Cited by 16
Perioperative Uses of Transcranial Perfusion Monitoring
Smith, M. (2008) · Neurosurgery Clinics of North America · doi:10.1016/j.nec.2008.07.008 · Cited by 15
Near-Infrared Spectroscopy and Its Use for the Assessment of Tissue Perfusion in the Neonate
Victor, S., & Weindling, M. (2012) · Elsevier eBooks · doi:10.1016/b978-1-4377-2763-0.00007-x · Cited by 14
Pulse oximeter bench tests under different simulated skin tones
Swamy, S. K. N., He, C., Hayes‐Gill, B., Clark, D. J., Green, S., & Morgan, S. P. (2024) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-024-03091-2 · Cited by 14
“However, the OPL within the tissue does change with wavelength and is also dependent on the underlying optical properties [24].”
Design and Validation of Android Based Wireless Integrated Device for Ubiquitous Health Monitoring
Singh, M., & Jain, N. (2015) · Wireless Personal Communications · doi:10.1007/s11277-015-2792-5 · Cited by 14
“Recently Beer—Lambert law based non-invasive method of oxygen measurement and heart rate is clinically used [9–11].”
MethodKashyap, D. (2007) · UTA ResearchCommons (University of Texas Arlington) · Cited by 13
Wigal, S. B., Polzonetti, C. M., Stehli, A., & Gratton, E. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.12.127002 · Cited by 12
Self-citationAlgorithm for automated selection of application-specific fiber-optic reflectance probes
Gomes, A., & Backman, V. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.2.027012 · Cited by 12
Blaney, G. P., Sassaroli, A., & Fantini, S. (2024) · Journal of Innovative Optical Health Sciences · doi:10.1142/s1793545824300015 · Cited by 12
Self-citationWu, J., Tabassum, S. M., Brown, W. L., Wood, S., Yang, J., & Kainerstorfer, J. M. (2022) · PLoS ONE · doi:10.1371/journal.pone.0274258 · Cited by 12
Data analysis and statistical tests for near-infrared functional studies of the brain
Sassaroli, A., Tong, Y., Beneš, C., & Fantini, S. (2008) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.761707 · Cited by 12
Self-citationEffect of age on brain oxygenation regulation during changes in position
Gatto, R. G., Hoffman, W. E., Paisansathan, C., Mantulin, W. W., Gratton, E., & Charbel, F. T. (2007) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2007.04.020 · Cited by 12
Self-citationYang, R., Zhang, Q., Wu, Y., & Dunn, J. F. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.1.016011 · Cited by 12
“By varying the source detector distances and plotting them against each of these three parameters, μa and μs can be solved using the slopes of these three regressions.(41) The TRS method utilizes the relationship between the amount of Fig.”
MethodNear-Infrared Spectroscopy and its Use for the Assessment of Tissue Perfusion in the Neonate
Victor, S., & Weindling, M. (2008) · Elsevier eBooks · doi:10.1016/b978-1-4160-3162-8.10006-5 · Cited by 11
Design of Smart Brain Oxygenation Monitoring System for Estimating Cardiovascular Disease Severity
Chou, W., Wu, P.-J., Fang, C.-C., Yen, Y.-S., & Lin, B. (2020) · IEEE Access · doi:10.1109/access.2020.2997865 · Cited by 11
Oziel, M., Rubinsky, B., & Korenstein, R. (2020) · PeerJ · doi:10.7717/peerj.10416 · Cited by 11
“158 Fantini et al. (Fantini et al., 1999) used pigs and light spectroscopy to detect disturbances in brain PeerJ reviewing PDF | (2020:07:51224:1:2:NEW 22 Oct 2020) 159 hemodynamics, and Zhou et al. (Zhou et al., 2009) performed similar research.”
MethodWu, J., McKnight, J. C., Bønnelycke, E. S., Bosco, G., Giacon, T. A., & Kainerstorfer, J. M. (2023) · Journal of Biomedical Optics · doi:10.1117/1.jbo.28.11.115002 · Cited by 11
“16 Further validation using data from various clinical settings and patient populations would be beneficial in assessing the generalizability of our findings.”
MethodGao, L., Elwell, C. E., Kohl‐Bareis, M., Gramer, M., Cooper, C. E., Leung, T. S., & Tachtsidis, I. (2011) · Advances in experimental medicine and biology · doi:10.1007/978-1-4419-7756-4_3 · Cited by 11
“From the diffusion theory, the relationship between the DPF and absorption coefficient (μa) and reduced scattering coefficient (μs’) in an infinite turbid medium has been shown to be [1]:”
BackgroundMethod for Measuring Absolute Optical Properties of Turbid Samples in a Standard Cuvette
Blaney, G. P., Sassaroli, A., & Fantini, S. (2022) · Applied Sciences · doi:10.3390/app122110903 · Cited by 11
“The motivation for utilizing the natural logarithm in this way is that it partly linearizes typical expressions for diffuse optical measurements (T̃ in this case) as a function of ρ [31].”
Self-citationChen, Y., Intes, X., Tailor, D. R., Regatte, R. R., Ma, H., Ntziachristos, V., LEIGH, J. S. J., Reddy, R. D., & Chance, B. (2003) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-0205-0_33 · Cited by 11
Artifact Management for Cerebral Near-Infrared Spectroscopy Signals: A Systematic Scoping Review
Bergmann, T., Vakitbilir, N., Gomez, A., Islam, A., Stein, K. Y., Sainbhi, A. S., Froese, L., & Zeiler, F. A. (2024) · Bioengineering · doi:10.3390/bioengineering11090933 · Cited by 10
“The main concern for the widespread clinical implementation of NIRS-based metrics is that monitoring conducted at the bedside is often riddled with artifacts from device disruption, patient motion, and loss of signal quality [14–17].”
BackgroundShanshool, A. S., Ziaee, S., Ansari, M. A., & Tuchin, V. V. (2024) · Progress in Quantum Electronics · doi:10.1016/j.pquantelec.2024.100506 · Cited by 10
Acharya, D., Mukherjea, A., Cao, J., Ruesch, A., Schmitt, S. E., Yang, J., Smith, M. A., & Kainerstorfer, J. M. (2022) · Metabolites · doi:10.3390/metabo12070667 · Cited by 10
“The measured tissue optical properties (μa and μs′) were also used to estimate a differential pathlength factor (DPF) under the assumption of a semi-infinite medium [43] for the third source-detector distance (2.”
MethodIncreased brain oxygenation during intubation-related stress
Paisansathan, C., Hoffman, W. E., Gatto, R. G., Baughman, V. L., Mueller, M., & Charbel, F. T. (2007) · European Journal of Anaesthesiology · doi:10.1017/s0265021507000567 · Cited by 10
“However, FD-NIRS uses an array of light sources arranged at multiple distances and frequency modulation of near-infrared light intensity to measure light scattering and absorption [15].”
MethodSassaroli, A., Blaney, G. P., & Fantini, S. (2023) · Biomedical Optics Express · doi:10.1364/boe.485651 · Cited by 10
Self-citationWang, H., Yang, X., Wang, Z., Deng, Z., Gong, H., & Luo, Q. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.6.061207 · Cited by 9
Fast optical signals in the peripheral nervous system
Tong, Y., Martin, J. M., Sassaroli, A., Clervil, P. R., Bergethon, P. R., & Fantini, S. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2234319 · Cited by 9
Self-citationZha, Y., Liu, G., Shang, X., Wang, F., Cai, J., & Wei, X. (2017) · Optik · doi:10.1016/j.ijleo.2017.10.116 · Cited by 8
Li, Z., Englund, E. K., Langham, M. C., Feng, J., Jia, K., Floyd, T. F., Yodh, A. G., & Baker, W. B. (2021) · Metabolites · doi:10.3390/metabo11120814 · Cited by 8
“, L (685 nm), L (785 nm), L (830 m)) used in the modified Beer–Lambert approach ere calculated based on t frequency-d main DOS measurements of resting calf muscle absorption and redu ed scatteri coefficients, as describ d el ewhere [44].”
MethodEvaluating feasibility of functional near-infrared spectroscopy in dolphins
Ruesch, A., Acharya, D., Bulger, E., Cao, J., McKnight, J. C., Manley, M., Fahlman, A., Shinn‐Cunningham, B. G., & Kainerstorfer, J. M. (2023) · Journal of Biomedical Optics · doi:10.1117/1.jbo.28.7.075001 · Cited by 8
“Using the multi-distance approach for optical property calculation, 25,26 we determined the average μ a and μ 0 s across the ∼ 2-min measurement period.”
MethodNguyen, T. K., Park, S., Hill, B. Y., & Gandjbakhche, A. (2023) · IEEE Open Journal of Engineering in Medicine and Biology · doi:10.1109/ojemb.2023.3246929 · Cited by 8
“(11) is an approximated version of the one reported in the literature under the zero-boundary condition [30].”
BackgroundBergmann, T., Froese, L., Gomez, A., Sainbhi, A. S., Vakitbilir, N., Islam, A., Stein, K. Y., Marquez, I., Amenta, F., Park, K., et al. (2023) · Bioengineering · doi:10.3390/bioengineering11010033 · Cited by 8
“Bedside monitoring induces various artifacts into data streams, like device disruption, patient motion, and loss of signal quality [8–11].”
BackgroundMitsuie, T., Nakamura, S., Htun, Y., Nakao, Y., Arioka, M., Koyano, K., Morimoto, A., Wakabayashi, T., Kuroda, Y., & Kusaka, T. (2021) · Scientific Reports · doi:10.1038/s41598-021-92586-1 · Cited by 8
“HR (bpm) 229 (35) 206 (27)*** 139 (25)** 193 (32) 249 (29) 255 (31) 224 (34)”
Three-dimensional optical tomographic brain imaging in small animals
Bluestone, A. Y., Abdoulaev, G. S., Lasker, J. M., Stewart, M., & Hielscher, A. H. (2002) · Biomedical Topical Meeting · doi:10.1364/bio.2002.suc5 · Cited by 8
Diffuse Optical Spectroscopy Assessment of Resting Oxygen Metabolism in the Leg Musculature
Boebinger, S. E., Brothers, R. O., Bong, S. M., Sanders, B., McCracken, C., Ting, L. H., & Buckley, E. M. (2021) · Metabolites · doi:10.3390/metabo11080496 · Cited by 7
“We also estimated the wavelength-dependent differential pathlength factor (DPF(λ)) that accounts for the increase in photon pathlength due to multiple scattering events using the following formula [39]: DPF(λ) = 3μ ′(λ) 2 3μ (λ)μ ′(λ) 1 (1)”
MethodCerebral Hemodynamics in High-Risk Neonates Probed by Diffuse Optical Spectroscopies
Buckley, E. M. (2011) · ScholarlyCommons (University of Pennsylvania) · Cited by 7
Optical cerebral blood flow monitoring of mice to men
Baker, W. B. (2015) · Scholarly Commons (University of Pennsylvania) · Cited by 7
Saeed, F., Carter, C., Kolade, J. O., Brothers, R. M., & Liu, H. (2024) · Journal of Biomedical Optics · doi:10.1117/1.jbo.29.11.117001 · Cited by 7
Perioperative Uses of Transcranial Perfusion Monitoring
Smith, M. (2007) · Anesthesiology Clinics · doi:10.1016/j.anclin.2007.05.002 · Cited by 6
Detecting Controlled Signals in the Human Brain by Near Infrared Spectroscopy
Kohlenberg, J., & Chau, T. T. (2006) · Conference proceedings · doi:10.1109/iembs.2006.4398695 · Cited by 6
Bluestone, A. Y., Abdoulaev, G. S., Barbour, R. L., Schmitz, C., & Hielscher, A. H. (2001) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.434496 · Cited by 6
“A MOBIIR scheme consists, in general, of three major parts: (1) a forward model that predicts the detector readings based on a given spatial distribution of optical properties ζ = ( μa(r) ,D(r)), (2) an objective function Φ that compares predicted with measured signals, and (3) an updating scheme that uses the gradien…”
BackgroundMethodCoherent hemodynamics spectroscopy: initial applications in the neurocritical care unit
Tgavalekos, K. T., Sassaroli, A., Cai, X., Kornbluth, J. A., & Fantini, S. (2017) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2251021 · Cited by 5
“The absolute values were computed from multi-distance, frequency-domain measurements with the assumptions of a semi-infinite, homogenous medium and extrapolated boundary conditions.(6) The phase at 0 Hz is 0 by definition.”
MethodSelf-citationHistory of Diffuse Optical Spectroscopy of Human Tissue
Huppert, T. J. (2012) · Springer eBooks · doi:10.1007/978-1-4614-4978-2_2 · Cited by 5
A novel noninvasive all optical technique to monitor physiology of an exercising muscle
Saxena, V., Marcu, L., & Karunasiri, G. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/21/021 · Cited by 5
“…been used extensively for studying tumor oxygenation both in human and small animal models (Saxena et al 2006, Caccia et al 2003, Franceschini et al 1997), functional response (Siegel et al 2003), cortical hemodynamics and brain activity (Saxena et al 2007a, Fantini et al 1999, Culver et al 2003).”
MethodA Non-invasive, in Vivo Technique for Monitoring Vascular Status of Glioblastoma during Angiogenesis
Saxena, V., González-Gómez, I., & Laug, W. E. (2007) · Technology in Cancer Research & Treatment · doi:10.1177/153303460700600608 · Cited by 5
Adingupu, D. D., Soroush, A., Hansen, A., Twomey, R., & Dunn, J. F. (2023) · Advances in experimental medicine and biology · doi:10.1007/978-3-031-42003-0_33 · Cited by 5
Intraoperative Human Functional Brain Mapping Using Optical Intrinsic Signal Imaging
Sameer, A., Yanamadala, V., & Emad, N. (2012) · InTech eBooks · doi:10.5772/29255 · Cited by 5
“Alternatively, frequency domain systems can measure the phase difference between incident and remitted light [120-121].”
BackgroundTachtsidis, I., Leung, T. S., Ghosh, A., Smith, M., Cooper, C. E., & Elwell, C. E. (2010) · Biomedical Optics and 3-D Imaging · doi:10.1364/biomed.2010.btub7 · Cited by 5
Zhang, Z., Qi, M., Hügli, G., & Khatami, R. (2021) · Biosensors · doi:10.3390/bios12010003 · Cited by 4
NONINVASIVE NEAR-INFRARED DIFFUSE OPTICAL MONITORING OF CEREBRAL HEMODYNAMICS AND AUTOREGULATION
Cheng, R. (2013) · UKnowledge (University of Kentucky) · Cited by 4
Metadata
- Authors
- Fantini, S., Hueber, D., Franceschini, M. A., Gratton, E., Rosenfeld, W., Stubblefield, P. G., Maulik, D., & Stankovic, M. R.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- International Space Station (US)
- Winthrop-University Hospital (US)
- Boston University (US)
- Boston Medical Center (US)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1999-01-01
- Volume
- 44
- Issue
- 6
- Pages
- 1543-1563
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2005686740
- Semantic Scholar
- 33e572f124903d86d761f0e4ed6fd287d63a48ab
- Cited by
- 277
- References
- 62
- Citations by year
- 2026: 6 · 2025: 8 · 2024: 10 · 2023: 13 · 2022: 11 · 2021: 20 · 2020: 15 · 2019: 8 · 2018: 4 · 2017: 3 · 2016: 6 · 2015: 13 · 2014: 8 · 2013: 12 · 2012: 23
- FWCI
- 8.00
- Type
- journal article
- Language
- en
- Open access
- green
- escholarship.org
- Licence
- cc-by
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion, cc-by)
- Funders
- National Institutes of Health (5r01rr010966-06, 5r01ca057032-08)
- National Cancer Institute (CA 57032)
- National Center for Research Resources (RR 10966)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Keywords
- reduced scattering coefficient, frequency domain spectroscopy, continuous-wave spectroscopy, carotid artery occlusion, cerebral hemodynamics, cerebral oxygenation, motion artifacts
- MeSH terms
- Animals, Animals, Newborn, Asphyxia, Brain, Hemoglobins, Models, Theoretical, Radiography, Swine, Time Factors, Reproducibility of Results, Carotid Stenosis, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.