Non-invasive optical monitoring of the newborn piglet brain using continuous-wave and frequency-domain spectroscopy
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
We have used continuous-wave (CW) and frequency-domain spectroscopy to investigate the optical properties of the newborn piglet brain in vivo and non-invasively. Three anaesthetized, intubated, ventilated and instrumented newborn piglets were placed into a stereotaxic instrument for optimal experimental stability, reproducible probe-to-scalp optical contact and 3D adjustment of the optical probe. By measuring the absolute values of the brain absorption and reduced scattering coefficients at two wavelengths (758 and 830 nm), frequency-domain spectroscopy provided absolute readings (in contrast to the relative readings of CW spectroscopy) of cerebral haemoglobin concentration and saturation during experimentally induced perturbations in cerebral haemodynamics and oxygenation. Such perturbations included a modulation of the inspired oxygen concentration, transient brain asphyxia, carotid artery occlusion and terminal brain asphyxia. The baseline cerebral haemoglobin saturation and concentration, measured with frequency-domain spectroscopy, were about 60% and 42 microM respectively. The cerebral saturation values ranged from a minimum of 17% (during transient brain asphyxia) to a maximum of 80% (during recovery from transient brain asphyxia). To analyse the CW optical data, we have (a) derived a mathematical relationship between the cerebral optical properties and the differential pathlength factor and (b) introduced a method based on the spatial dependence of the detected intens…
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This result is somehow expected since the assumption of fixed scattering heavily affects the hemoglobin concentrations absolute values (Fantini et al. 1999).”
From Validation of a novel wearable, wireless technology to estimate oxygen levels and lactate threshold power in the exercising muscle (2018) · cites this paper as Fantini et al. 1999
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245 · cited 2×
“The DPF is a parameter that takes into account the increased photon pathlength caused by multiple light scattering in tissues ( Delpy et al 1988, Cope et al 1991).”
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087 · cited 2×
“…≡ 〈L〉 r ∼= v〈t〉 r = v r ∫ ∞ 0 tGseminf(r, t) dt∫ ∞ 0 Gseminf(r, t) dt = √ 3μ′s 2√μa0 r √ 3μa0μ′s r √ 3μa0μ′s + 1 (10) where 〈t〉 is the average photon time of flight and the semi-infinite medium Green function Gseminf(r, t) is ∝ t−5/2 exp[−3μ′sr2/(4vt) − μavt] (Patterson et al 1989).”
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618 · cited 2×
“…Edwards et al 1988) and in adults to quantify cerebral hemodynamics (Elwell et al 1994), to monitor brain activity (Gratton et al 1995, Meek et al 1995, Wenzel et al 1996, Tamura et al 1997, Villringer and Chance 1997) and to detect intracranial haematomas (Gopinath et al 1993, Hennes et al 1999).”
Farrell, T. J., Patterson, M. S., & Wilson, B. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,378
Cope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
The composition of body tissues
Woodard, H. Q., & White, D. R. (1986) · The British Journal of Radiology · doi:10.1259/0007-1285-59-708-1209 · Cited by 764
Arridge, S. R., Cope, M., & Delpy, D. T. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/005 · Cited by 595 · cited 1×
“(8) This approach to finding the DPF is equivalent to the definition (Cope et al 1991, Arridge et al 1992) DPF ≡ 1 r ∂A ∂μa ∣∣∣∣ μa0 (9) where A is the optical attenuation defined as ln (dc(0)/dc(t)).”
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528 · cited 1×
“…Ltd 1543 oxygenation during ischaemia (Hampson and Piantadosi 1988, Ferrari et al 1992, Sahlin 1992, Fantini et al 1995, Miwa et al 1995) or exercise (Chance et al 1992, Belardinelli et al 1995, Hamaoka et al 1996, Franceschini et al 1997, Quaresima et al 1998), the assessment of the local blood…”
van der Zee, P., Cope, M., Arridge, S. R., Essenpreis, M., Potter, L. A., Edwards, A. D., Wyatt, J. S., McCormick, D. C., Roth, S. C., Reynolds, E. O. R., et al. (1992) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4615-3404-4_17 · Cited by 427 · cited 2×
“Since there are no published DPF values for the piglet brain, previous studies on piglets have assumed values of 3.85 (Brun et al 1997) or 4.39 (Stankovic et al 1998), which are values reported for the brain of newborn infants (Wyatt et al 1990, Van der Zee et al 1992).”
InfluentialCOTSIDE MEASUREMENT OF CEREBRAL BLOOD FLOW IN ILL NEWBORN INFANTS BY NEAR INFRARED SPECTROSCOPY
Edwards, A. D., Richardson, C., Cope, M., Wyatt, J. S., Delpy, D. T., & Reynolds, E. O. R. (1988) · The Lancet · doi:10.1016/s0140-6736(88)92418-x · Cited by 370 · cited 1×
“…spectroscopy has also been non-invasively applied to the human infant’s brain to measure cerebral oxygenation and hemodynamics (Cope and Delpy 1988, Edwards et al 1988) and in adults to quantify cerebral hemodynamics (Elwell et al 1994), to monitor brain activity (Gratton et al 1995, Meek et al…”
Cited by
Items 201–298 of 298
Tisdall, M. M. (2007) · UCL Discovery (University College London) · Cited by 4
Gurley, K. M. (2012) · UKnowledge (University of Kentucky) · Cited by 4
Optical clearing of human cranial bone by administration of immersion agents
Genina, E. A., Bashkatov, A. N., & Tuchin, V. V. (2006) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.697308 · Cited by 4
Choi, J., Choi, M.-G., & Bae, H. (2012) · IEEE International Symposium on Circuits and Systems proceedings · doi:10.1109/iscas.2012.6272091 · Cited by 4
Gomero, L. M., İzzetoğlu, M., Malaeb, S. N., & İzzetoğlu, K. (2024) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2024.3502725 · Cited by 4
Frequency-domain instrument with custom ASIC for dual-slope near-infrared spectroscopy
Kılıç, A., Blaney, G. P., Tavakoli, F., Frias, J., Sassaroli, A., Fantini, S., & Koomson, V. (2024) · Review of Scientific Instruments · doi:10.1063/5.0227363 · Cited by 4
Self-citationİzzetoğlu, K., Malaeb, S. N., Polat, M. D., Sinahon, R. S., Shoshany, D. S., Gomero, L. M., Shewokis, P. A., & İzzetoğlu, M. (2024) · Military Medicine · doi:10.1093/milmed/usae157 · Cited by 4
Real-time imaging of tissue optical properties and surface profile using 3D-SSOP
van de Giessen, M., Angelo, J. P., Vargas, C. R., & Gioux, S. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2076562 · Cited by 4
Fanta, A., Dosunmu-Ogunbi, A. M., Ruesch, A., Jonassaint, J., Disu, J. D. K., Xu, J. Z., Huppert, T. J., Kainerstorfer, J. M., Novelli, E. M., & Wood, S. (2025) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00426.2023 · Cited by 3
Artefacts in continuous neuromonitoring
Chen, X., Bögli, S. Y., Olakorede, I., Xu, W., Beqiri, E., Tang, C., Occhipinti, L. G., Gao, S., & Smielewski, P. S. (2026) · Nature Reviews Bioengineering · doi:10.1038/s44222-025-00378-3 · Cited by 3
Ko, T. S., Mavroudis, C. D., Benson, E. J., Forti, R. M. M., Melchior, R. W., Boorady, T. W., Morano, V. C., Mensah-Brown, K. G., Lin, Y., Aronowitz, D. I., et al. (2022) · Metabolites · doi:10.3390/metabo12080737 · Cited by 3
Mohammad, P. P. S., Isarangura, S., Eddins, A. C., & Parthasarathy, A. B. (2021) · Neurophotonics · doi:10.1117/1.nph.8.4.045004 · Cited by 3
“…for each subject and was calculated as ffiffiffiffiffiffiffiffiffi p , where μ a and μ 0 s were estimated from the baseline data calculated with FD-NIRS analysis, 27 ρ is the source – detector separation in cm, and ϵ HbO ∕ HbR ð λ i Þ is the molar extinction coefficient of HbO/HbR at wavelength λ i in cm − 1…”
Measurement of Hemoglobin Oxygenation Parameters in Arterial Occlusion and Physical Exertion
Buyanov, D., Владимирович, Ш. П., Zabodaev, S. V., Monakhova, P. A., Stavtsev, D. D., Konovalov, A. N., & Gerasimenko, A. Y. (2023) · Biomedical Engineering · doi:10.1007/s10527-023-10299-3 · Cited by 4
Gomero, L. M., İzzetoğlu, M., Sinahon, R. S., Malaeb, S. N., & İzzetoğlu, K. (2025) · IEEE Transactions on Instrumentation and Measurement · doi:10.1109/tim.2025.3619245 · Cited by 3
“In BFi estimation, for tissue optical properties, we used published values for piglets with µ a = 0.15 (1 / cm) and µ s = 9.3 (1 / cm) [58], [59], [60], [61], assuming they remained constant throughout the recording period.”
InfluentialFunctional Near Infrared Spectroscopy: Watching the Brain in Flight
Harrivel, A. R., & Hearn, T. A. (2012) · NASA STI Repository (National Aeronautics and Space Administration) · Cited by 3
Ho, J. H., Chin, H. L., Dong, J., & Lee, K. (2011) · Optics Communications · doi:10.1016/j.optcom.2011.12.018 · Cited by 3
Human cortical perfusion and the arterial pulse: a near-infrared spectroscopy study
Kwan, H. C., Cheng, A., Liu, R., & Borrett, D. S. (2004) · BMC Physiology · doi:10.1186/1472-6793-4-7 · Cited by 3
“More recently, in noninvasive optical monitoring of the newborn piglet brain under general anesthesia, a spectral component related to the arterial pulse was observed, which disappeared when the piglet died, an observation in confirmation of its cardiac origin [3].”
Sensitivity of functional near-infrared spectroscopy to optical properties in brain imaging
Donaldson, A., Andrare, D., & Das, M. (2023) · doi:10.1117/12.2657054 · Cited by 3
Wallace, D. J., Barbieri, B. B., & Hintz, S. R. (2000) · Biomedical Optical Spectroscopy and Diagnostics · doi:10.1364/bosd.2000.suf1 · Cited by 3
Characterization of Breast Tumors with NIR Methods using Optical Indices
Alacam, B., Yazıcı, B., Chance, B., & Nioka, S. (2007) · Conference proceedings · doi:10.1109/iembs.2007.4353510 · Cited by 3
“where I is light intensity after absorption and scattering, and I0 is the baseline light intensity obtained from the contralateral breast, using known extinction coefficients of Hb, HbO2 and differential pathlength factors [ 10 ].”
MethodFinite Element Modeling of Abdominal Near‐Infrared Spectroscopy for Infant Splanchnic Oximetry
Emani, V. S., Öztürk, Ç., Singh, M., Long, C., Duffy, S., Sen, D. G., Roche, E. T., & Baker, W. B. (2025) · International Journal for Numerical Methods in Biomedical Engineering · doi:10.1002/cnm.70035 · Cited by 2
Comparison of Kernels in Online SVM Classification of fNIRS Data
Huang, R., Kavichai, E., & Hong, K. (2018) · International Conference on Control, Automation and Systems (ICCAS) · Cited by 2
Huang, R., Woo, S.-W., & Hong, K. (2020) · International Conference on Computer and Automation Engineering · doi:10.1145/3384613.3384620 · Cited by 2
“A study shows that MA can be reduced by utilizing multi-optodes data to provide relative readings in the DC slope [9].”
BackgroundSelf-calibrated pulse oximetry based on absorption changes in photon pathlength
Wu, J., Gunther, J. E., Jayet, B., Ray, N., Andersson‐Engels, S., & Kainerstorfer, J. M. (2021) · Diffuse Optical Spectroscopy and Imaging · doi:10.1117/12.2615342 · Cited by 2
“For a semi-infinite medium, the analytical equation for <L> is given by [7]:”
BackgroundNear-Infrared Spectroscopy and Its Use for the Assessment of Tissue Perfusion in the Neonate
Victor, S., Lemmers, P. M. A., & Weindling, M. (2019) · Elsevier eBooks · doi:10.1016/b978-0-323-53366-9.00017-x · Cited by 2
Haratbar, S. R., Hamedi, F., Mohtasebi, M., Fathi, F., Akbari, F., Singh, D., Liu, X., Chen, L., Wong, L. K., Chen, L., et al. (2025) · Biomedical Optics Express · doi:10.1364/boe.573315 · Cited by 2
Diffuse optical detection of global cerebral ischemia in an adult porcine model
Fu, C., Wang, D., Wang, L., Zhu, L., Li, Z., Chen, T., Feng, H., & Li, F. (2022) · Journal of Biophotonics · doi:10.1002/jbio.202200168 · Cited by 2
Shoshany, D. S., İzzetoğlu, K., Shewokis, P. A., Shtraikh, S., Avraham, L. W., & Nachman, D. (2025) · Military Medicine · doi:10.1093/milmed/usaf127 · Cited by 2
Diffuse Optical Detection of Cerebral Ischemia During Carotid Endarterectomy
Shang, Y., Cheng, R., Dong, L., Saha, S. P., & Yu, G. (2010) · Biomedical Optics and 3-D Imaging · doi:10.1364/biomed.2010.bsud78 · Cited by 2
Scavariello, G. H. (2021) · doi:10.47749/t/unicamp.2021.1232305 · Cited by 1
Polat, M. D., İzzetoğlu, K., Shewokis, P. A., İzzetoğlu, M., Green, M. S., & Malaeb, S. N. (2026) · Neuroimaging · doi:10.3390/neuroimaging1030012 · Cited by 1
“During the in vivo fitting, the tissue optical properties were assumed constant, with an absorption coefficient ( µ a ) of 0.15 cm − 1 and a reduced scattering coefficient ( µ s ′ ) of 9.1 cm − 1 , based on literature values for neonatal piglet brain tissue [50].”
InfluentialSeparation of the hemodynamic responses in a simultaneous audio-stimuli using ICA: An fNIRS study
Santosa, H., & Hong, K. (2015) · International Conference on Control, Automation and Systems (ICCAS) · doi:10.1109/iccas.2015.7364655 · Cited by 1
“Keywords: functional near-infrared spectroscopy, independent component analysis, auditory cortex, multiple-stimuli.”
BackgroundFast optical signals during median nerve stimulation by using continuous-wave NIRS
Santosa, H., Huppert, T. J., & Hong, K. (2015) · International Conference on Automation, Cognitive Science, Optics, Micro Electro-Mechanical System, and Information Technology (ICACOMIT) · doi:10.1109/icacomit.2015.7440151 · Cited by 1
“The changes between incident and detected lights are causing the changes HbO and HbR which is calculated using modified Beer-Lambert law [7-9] and Boltzmann’s transport equation [10] for continuous-wave-(CW) and frequency-domain-(FD) type, respectively.”
Self-Calibrated Pulse Oximetry Based on Absorption Changes in Photon Pathlength
Wu, J., Gunther, J. E., Jayet, B., Ray, N., Andersson‐Engels, S., & Kainerstorfer, J. M. (2021) · European Conferences on Biomedical Optics (ECBO) · doi:10.1364/ecbo.2021.em3c.3 · Cited by 1
Wu, J., Debreczeny, M. P., Hanumara, N. C., Ray, N., Jayet, B., Andersson‐Engels, S., & Kainerstorfer, J. M. (2025) · Journal of Physics Photonics · doi:10.1088/2515-7647/ae1a27 · Cited by 1
“First, the photon mean pathlength ⟨ L ⟩ for reflectance geometry in a semi-infinite medium is analytically given by [23]: where r is the SD distance, and µ ′ s is the reduced scattering coefficient, typically obtained from literature or assumed based on tissue type.”
Which blood oxygen can sensitively indicate shock severity?
Pan, B., Li, K., Gao, Y., Ruan, Z., & Li, T. (2016) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2211335 · Cited by 1
Photodynamic Therapy for the Management of Disease: Advances and Perspectives
Malviya, R., Singh, A. K., & Sharma, R. (2025) · Apple Academic Press eBooks · doi:10.1201/9781003609841 · Cited by 1
Spatially-resolved optical monitoring of bioreactor cell growth
Gorecki, J., Redwood-Sawyerr, C., Cao, J., Dehghani, H., Kontoravdi, C., Polizzi, K. M., & Rowlands, C. J. (2026) · Biomedical Optics Express · doi:10.1364/boe.583724 · Cited by 1
“The effective scattering coefficient can be extracted from the imaging data by analysing the image intensity I along a straight line, as a function of distance d from the laser illumination spot [22].”
Monitoring muscle oxygenation and myoelectric activity after damage-inducing exercise
Ahmadi, S. (2007) · The Sydney eScholarship Repository (The University of Sydney) · Cited by 1
Noninvasive Optical Detection of Spontaneous Low Frequency Oscillations in Cerebral Blood Flow
Cheng, R., Shang, Y., & Yu, G. (2012) · Biomedical Optics and 3-D Imaging · doi:10.1364/biomed.2012.bm4a.6 · Cited by 1
Karagulleoglu-Kunduraci, S., Kamar, F., Eskandari, R., Samaei, S., & Diop, M. (2025) · Pediatric Research · doi:10.1038/s41390-025-04446-7 · Cited by 1
Differential pathlength factor model for near-infrared diffuse optical imaging
Niknam, K., Paul, M. B., & Das, M. (2026) · Biomedical Optics Express · doi:10.1364/boe.601705 · Cited by 1
“Fantini et al. , for example, applied this approach to assess cerebral oxygenation in neonates [24], while Chiarelli et al. employed it in high-density adult recordings to mitigate hemoglobin cross-talk [49].”
InfluentialPreliminary tests on a new near-infrared continuous-wave tissue oximeter
Casavola, C., Cicco, G., Pirrelli, A., & Lugarà, P. M. (2000) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.407618 · Cited by 1
Davies, D. J. (2017) · University of Birmingham Institutional Research Archive (University of Birmingham) · Cited by 1
Cerebral response to auditory oddball task using multi-distance near-infrared spectroscopy
Tong, Y., Martin, J. M., Sassaroli, A., Fantini, S., Rooney, E. J., & Bergethon, P. R. (2006) · Biomedical optics · doi:10.1364/bio.2006.mi3 · Cited by 1
Self-citationCalculations of BOLD signals by use of NIRS photon migration hitting density functions
Sassaroli, A., Tong, Y., Frederick, B. B., Renshaw, P. F., & Fantini, S. (2006) · Biomedical optics · doi:10.1364/bio.2006.me30 · Cited by 1
Self-citationHielscher, A. H., Bluestone, A. Y., Schmitz, C., Barbour, R. L., & Abdoulaev, G. S. (2002) · Biomedical Topical Meeting · doi:10.1364/bio.2002.mc6 · Cited by 1
Real-time optical imaging and spectroscopy of brain ischemia and hemorrhage
Stankovic, M. R., Hueber, D. M., Maulik, D., Stubblefield, P. G., Rosenfeld, W., Gratton, E., Franceschini, M. A., & Fantini, S. (1999) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.356808 · Cited by 1
Self-citationMohammad, P. P. S. (2018) · Digital Commons - University of South Florida (University of South Florida) · Cited by 1
Chetia, S. (2024) · UPCommons institutional repository (Universitat Politècnica de Catalunya) · doi:10.5821/dissertation-2117-422062
Mavroudis, C. D., Ko, T. S., Morgan, R. W., Volk, L. E., Landis, W. P., Smood, B. F., Xiao, R., Hefti, M., Boorady, T. W., Marquez, A., et al. (2020) · Figshare · doi:10.6084/m9.figshare.13024419
Mavroudis, C. D., Ko, T. S., Morgan, R. W., Volk, L. E., Landis, W. P., Smood, B. F., Xiao, R., Hefti, M., Boorady, T. W., Marquez, A., et al. (2020) · Figshare · doi:10.6084/m9.figshare.13024416
Mavroudis, C. D., Ko, T. S., Morgan, R. W., Volk, L. E., Landis, W. P., Smood, B. F., Xiao, R., Hefti, M., Boorady, T. W., Marquez, A., et al. (2020) · Figshare · doi:10.6084/m9.figshare.13024413
Advances in Hyperspectral and Multispectral Optical Spectroscopy and Imaging of Tissue
Toronov, V. Y., Diop, M., Sassaroli, A., & Tachtsidis, I. (2022) · MDPI eBooks · doi:10.3390/books978-3-0365-4478-6
Blaney, G. P., Sassaroli, A., Das, T., & Fantini, S. (2025) · Photonics · doi:10.3390/photonics12070697
“These two methods are the slopes method [2] and the iterative method [16], where the slope method is simpler but contains stronger assumptions in its derivation.”
Self-citationAnkit, J. H. A., & Singh, V. (2026) · Brain Structure and Function · doi:10.1007/s00429-026-03201-w
“However, motion artifacts (MAs) are a challenge as they introduce spikes and baseline shifts in the signal through movement in optical fibers which disrupt scalp-optode coupling (Fantini et al. 1999; Yamada et al. 2015).”
DEKF to Estimate Hemodynamic Response and Path-length in fNIRS Data
Huang, R., & Hong, K. (2019) · International Conference on Control, Automation and Systems (ICCAS) · doi:10.23919/iccas47443.2019.8971708
“The extraction methods of hemoglobin concentration in real time consist the Beer-Lambert law or the modified one (mBLL) [6-9], diffusion approximation to the Blotzmann transport equation [10-12] and time correlated single photon counting technique (TCSPC) [13].”
MethodDepth dependent coherent hemodynamics during induced blood pressure oscillations
Pham, T., Fantini, S., Sassaroli, A., & Blaney, G. P. (2019) · Optical Tomography and Spectroscopy of Tissue · doi:10.1117/12.2509861
Self-citationLaser/Light Applications in Neurology and Neurosurgery
Mathews, M. S., Abookasis, D., & Linskey, M. E. (2011) · Springer eBooks · doi:10.1007/978-0-85729-281-0_46
Tavakoli, F., Wang, X., & Liu, H. (2025) · Research Square · doi:10.21203/rs.3.rs-7760901/v1
Tavakoli, F., & Liu, H. (2026) · Biomedical Optics Express · doi:10.1364/boe.612014
Digging Deeper with Diffuse Correlation Spectroscopy
Verdecchia, K. (2016) · Scholarship@Western (Western University)
Eschle, T. M. (2017) · Northumbria Research Link (Northumbria University)
Fernandez, C. M., Blaney, G. P., Pham, T., Sassaroli, A., & Fantini, S. (2020) · Optics in the Life Sciences · doi:10.1364/translational.2020.jw3a.13
Self-citationA Novel Differential Pathlength Factor Model for Near-Infrared Diffuse Optical ImagingPreprint
Das, M., Niknam, K., & Paul, M. B. (2026) · doi:10.1364/opticaopen.31993923.v1
Evans, M. C. W. (2018) · RECERCAT (Consorci de Serveis Universitaris de Catalunya)
Mohammad Mirzaei Zarandi, S. (2014) · eScholarship (California Digital Library)
Suciu, D., Pham, T., Wei, L. L., Hoekstra, I., Yadati, P., Chitalia, V. C., & Roblyer, D. M. (2026) · Biophotonics discovery. · doi:10.1117/1.bios.3.1.015003
Safavi, P. N., Mohtasebi, M., Haque, C. A., Akbari, F., Liu, X., Yuan, Y., Chen, L., Chen, L., & Yu, G. (2026) · Journal of Biomedical Optics · doi:10.1117/1.jbo.31.4.047001
Wang, D., Wang, L., Wang, J., Gao, P., Zhu, L., Li, Z., Chen, T., Li, F. Y., & Hua, F. (2020) · bioRxiv (Cold Spring Harbor Laboratory) · doi:10.1101/2020.08.07.241182
Lee, I., Kim, D., Kim, S., Kim, H. J., Chung, U. S., & Lee, J. J. (2023) · doi:10.3389/fnagi.2023.1168815.s002
Correa, B., & Ricardo, F. (2016) · LA Referencia (Red Federada de Repositorios Institucionales de Publicaciones Científicas)
Liu, Y. (2025) · Carolina Digital Repository (University of North Carolina at Chapel Hill) · doi:10.17615/12ga-f782
Cerebrovascular Blood Flow and Perfusion
Horn, P. (2002) · Springer eBooks · doi:10.1007/978-3-642-56225-9_39
Application of gain-modulated image intensifier in biomedical imaging
Ho, J. H. (2012) · DR-NTU (Nanyang Technological University) · doi:10.32657/10356/48674
Real-time imaging of tissue optical properties and surface profile using 3D-SSOP
van de Giessen, M., Angelo, J. P., Vargas, C. R., & Gioux, S. (2015) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.2077651
Three-dimensional optical tomographic imaging of vascular reactivity in the brain
Hielscher, A. H., Bluestone, A. Y., Abdoulaev, G. S., Lasker, J. M., Barbour, R. L., & Schmitz, C. (2001) · Photon Migration, Optical Coherence Tomography, and Microscopy · doi:10.1364/ecbo.2001.4431_207
Analysis of the Optical Signals Associated with the Electrical Stimulation of Peripheral Nerves
Chen, D. K., Tong, Y., Sassaroli, A., Martin, J. M., Bergethon, P. R., & Fantini, S. (2008) · Biomedical optics · doi:10.1364/biomed.2008.btue2
“Such signal amplitude is comparable to that of signals associated with optical fiber/skin coupling effects, as reported in optical measurements on a piglet model [6].”
BackgroundSelf-citationVolumetric vascular brain imaging in small animals with near-infrared optical tomography
Bluestone, A. Y., Stewart, M., Lasker, J., Abdoulaev, G. S., & Hielscher, A. H. (2003) · IEEE International Symposium on Biomedical Imaging (ISBI) · doi:10.1109/isbi.2002.1029250
Roche‐Labarbe, N., Kongolo, G., Grebe, R., & Wallois, F. (2008) · Biomedical optics · doi:10.1364/biomed.2008.bme4
Dynamic Monitoring of Absolute Cerebral Blood Flow with Near-Infrared Spectroscopy
Tgavalekos, K. T., Sassaroli, A., & Fantini, S. (2016) · Biomedical optics · doi:10.1364/cancer.2016.jw3a.34
Self-citationDetection of Consciously Controlled Motor Cortical Activation by Near Infrared Spectroscopy (NIRS)
Kohlenberg, J., & Chau, T. T. (2007) · CMBES Proceedings
Low cost wireless cerebral oximeter using Bluetooth Low Energy technology
Wu, K.-C., Tamborini, D., Peruch, A., Stephens, K. A., Salat, D. H., & Franceschini, M. A. (2020) · Optics in the Life Sciences · doi:10.1364/brain.2020.bm3c.4
Self-citationDual-Slope Imaging in Frequency-Domain Near-Infrared Spectroscopy
Blaney, G. P., Sassaroli, A., Pham, T., Fernandez, C. M., & Fantini, S. (2020) · Optics in the Life Sciences · doi:10.1364/translational.2020.jth2a.9
Self-citationSelf-Calibrated Pulse Oximetry Development Applied to Data from Human Freedivers
Wu, J., Ruesch, A., Bønnelycke, E. S., McKnight, J. C., Ray, N., Bosco, G., Paganini, M., Giacon, T. A., & Kainerstorfer, J. M. (2022) · Optics in the Life Sciences · doi:10.1364/ots.2022.ow3d.6
FlexNIRS, an open source wearable NIRS cerebral health tracker
Wu, K.-C., Renna, M., Huang, Y., Tamborini, D., Peruch, A., Martin, A., Kaya, K., Starkweather, Z., Zavriyev, A. I., Carp, S. A., et al. (2022) · Optics in the Life Sciences · doi:10.1364/brain.2022.btu2c.6
Self-citationSignal Processing for Monitoring Cerebral Hemodynamics in Neonates
Dorado, A. C. (2013) · Lirias
Artefacts in continuous neuromonitoring
Chen, X., Bögli, S. Y., Olakorede, I., Xu, W., Beqiri, E., Tang, C., Occhipinti, L. G., Gao, S., & Smielewski, P. S. (2026) · Apollo (University of Cambridge) · doi:10.17863/cam.129208
Zhao, H., DAVIS, C., Anderson, D. E., Bayle, B., Schulz, A., Ranieri, N. R., Majeski, J. B., Forti, R. M., Ko, T., Yodh, A. G., et al. (2026) · Optics in the Life Sciences · doi:10.1364/brain.2026.bs3a.2
Sinahon, R. S., Gomero, L. M., İzzetoğlu, M., Shewokis, P. A., Malaeb, S., & İzzetoğlu, K. (2026) · Computer Methods and Programs in Biomedicine · doi:10.1016/j.cmpb.2026.109675
Metadata
- Authors
- Fantini, S., Hueber, D., Franceschini, M. A., Gratton, E., Rosenfeld, W., Stubblefield, P. G., Maulik, D., & Stankovic, M. R.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- International Space Station (US)
- Winthrop-University Hospital (US)
- Boston University (US)
- Boston Medical Center (US)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1999-01-01
- Volume
- 44
- Issue
- 6
- Pages
- 1543-1563
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2005686740
- Semantic Scholar
- 33e572f124903d86d761f0e4ed6fd287d63a48ab
- Cited by
- 277
- References
- 62
- Citations by year
- 2026: 6 · 2025: 8 · 2024: 10 · 2023: 13 · 2022: 11 · 2021: 20 · 2020: 15 · 2019: 8 · 2018: 4 · 2017: 3 · 2016: 6 · 2015: 13 · 2014: 8 · 2013: 12 · 2012: 23
- FWCI
- 8.00
- Type
- journal article
- Language
- en
- Open access
- green
- escholarship.org
- Licence
- cc-by
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion, cc-by)
- Funders
- National Institutes of Health (5r01rr010966-06, 5r01ca057032-08)
- National Cancer Institute (CA 57032)
- National Center for Research Resources (RR 10966)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Keywords
- reduced scattering coefficient, frequency domain spectroscopy, continuous-wave spectroscopy, carotid artery occlusion, cerebral hemodynamics, cerebral oxygenation, motion artifacts
- MeSH terms
- Animals, Animals, Newborn, Asphyxia, Brain, Hemoglobins, Models, Theoretical, Radiography, Swine, Time Factors, Reproducibility of Results, Carotid Stenosis, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.