Non-invasive optical monitoring of the newborn piglet brain using continuous-wave and frequency-domain spectroscopy
Open accessThe DOI matches its Crossref record; 62 of the 62 references it cites were found in a registry or an index.
Abstract
We have used continuous-wave (CW) and frequency-domain spectroscopy to investigate the optical properties of the newborn piglet brain in vivo and non-invasively. Three anaesthetized, intubated, ventilated and instrumented newborn piglets were placed into a stereotaxic instrument for optimal experimental stability, reproducible probe-to-scalp optical contact and 3D adjustment of the optical probe. By measuring the absolute values of the brain absorption and reduced scattering coefficients at two wavelengths (758 and 830 nm), frequency-domain spectroscopy provided absolute readings (in contrast to the relative readings of CW spectroscopy) of cerebral haemoglobin concentration and saturation during experimentally induced perturbations in cerebral haemodynamics and oxygenation. Such perturbations included a modulation of the inspired oxygen concentration, transient brain asphyxia, carotid artery occlusion and terminal brain asphyxia. The baseline cerebral haemoglobin saturation and concentration, measured with frequency-domain spectroscopy, were about 60% and 42 microM respectively. The cerebral saturation values ranged from a minimum of 17% (during transient brain asphyxia) to a maximum of 80% (during recovery from transient brain asphyxia). To analyse the CW optical data, we have (a) derived a mathematical relationship between the cerebral optical properties and the differential pathlength factor and (b) introduced a method based on the spatial dependence of the detected intens…
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
In the citing paper
“This result is somehow expected since the assumption of fixed scattering heavily affects the hemoglobin concentrations absolute values (Fantini et al. 1999).”
From Validation of a novel wearable, wireless technology to estimate oxygen levels and lactate threshold power in the exercising muscle (2018) · cites this paper as Fantini et al. 1999
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Estimation of optical pathlength through tissue from direct time of flight measurement
Delpy, D. T., Cope, M., Zee, P. V. D., Arridge, S., Wray, S., & Wyatt, J. (1988) · Physics in Medicine and Biology · doi:10.1088/0031-9155/33/12/008 · Cited by 2,245 · cited 2×
“The DPF is a parameter that takes into account the increased photon pathlength caused by multiple light scattering in tissues ( Delpy et al 1988, Cope et al 1991).”
Patterson, M. S., Chance, B., & Wilson, B. C. (1989) · Applied Optics · doi:10.1364/ao.28.002331 · Cited by 2,087 · cited 2×
“…≡ 〈L〉 r ∼= v〈t〉 r = v r ∫ ∞ 0 tGseminf(r, t) dt∫ ∞ 0 Gseminf(r, t) dt = √ 3μ′s 2√μa0 r √ 3μa0μ′s r √ 3μa0μ′s + 1 (10) where 〈t〉 is the average photon time of flight and the semi-infinite medium Green function Gseminf(r, t) is ∝ t−5/2 exp[−3μ′sr2/(4vt) − μavt] (Patterson et al 1989).”
Non-invasive optical spectroscopy and imaging of human brain function
Villringer, A., & Chance, B. (1997) · Trends in Neurosciences · doi:10.1016/s0166-2236(97)01132-6 · Cited by 1,618 · cited 2×
“…Edwards et al 1988) and in adults to quantify cerebral hemodynamics (Elwell et al 1994), to monitor brain activity (Gratton et al 1995, Meek et al 1995, Wenzel et al 1996, Tamura et al 1997, Villringer and Chance 1997) and to detect intracranial haematomas (Gopinath et al 1993, Hennes et al 1999).”
Farrell, T. J., Patterson, M. S., & Wilson, B. (1992) · Medical Physics · doi:10.1118/1.596777 · Cited by 1,378
Cope, M., & Delpy, D. T. (1988) · Medical & Biological Engineering & Computing · doi:10.1007/bf02447083 · Cited by 1,065
The composition of body tissues
Woodard, H. Q., & White, D. R. (1986) · The British Journal of Radiology · doi:10.1259/0007-1285-59-708-1209 · Cited by 764
Arridge, S. R., Cope, M., & Delpy, D. T. (1992) · Physics in Medicine and Biology · doi:10.1088/0031-9155/37/7/005 · Cited by 595 · cited 1×
“(8) This approach to finding the DPF is equivalent to the definition (Cope et al 1991, Arridge et al 1992) DPF ≡ 1 r ∂A ∂μa ∣∣∣∣ μa0 (9) where A is the optical attenuation defined as ln (dc(0)/dc(t)).”
Recovery from exercise-induced desaturation in the quadriceps muscles of elite competitive rowers
Chance, B., Dait, M. T., Zhang, C., Hamaoka, T., & Hagerman, F. (1992) · American Journal of Physiology-Cell Physiology · doi:10.1152/ajpcell.1992.262.3.c766 · Cited by 528 · cited 1×
“…Ltd 1543 oxygenation during ischaemia (Hampson and Piantadosi 1988, Ferrari et al 1992, Sahlin 1992, Fantini et al 1995, Miwa et al 1995) or exercise (Chance et al 1992, Belardinelli et al 1995, Hamaoka et al 1996, Franceschini et al 1997, Quaresima et al 1998), the assessment of the local blood…”
van der Zee, P., Cope, M., Arridge, S. R., Essenpreis, M., Potter, L. A., Edwards, A. D., Wyatt, J. S., McCormick, D. C., Roth, S. C., Reynolds, E. O. R., et al. (1992) · Advances in Experimental Medicine and Biology · doi:10.1007/978-1-4615-3404-4_17 · Cited by 427 · cited 2×
“Since there are no published DPF values for the piglet brain, previous studies on piglets have assumed values of 3.85 (Brun et al 1997) or 4.39 (Stankovic et al 1998), which are values reported for the brain of newborn infants (Wyatt et al 1990, Van der Zee et al 1992).”
InfluentialCOTSIDE MEASUREMENT OF CEREBRAL BLOOD FLOW IN ILL NEWBORN INFANTS BY NEAR INFRARED SPECTROSCOPY
Edwards, A. D., Richardson, C., Cope, M., Wyatt, J. S., Delpy, D. T., & Reynolds, E. O. R. (1988) · The Lancet · doi:10.1016/s0140-6736(88)92418-x · Cited by 370 · cited 1×
“…spectroscopy has also been non-invasively applied to the human infant’s brain to measure cerebral oxygenation and hemodynamics (Cope and Delpy 1988, Edwards et al 1988) and in adults to quantify cerebral hemodynamics (Elwell et al 1994), to monitor brain activity (Gratton et al 1995, Meek et al…”
Cited by
Diffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
“[35, 147–150], and many others).”
Progress of near-infrared spectroscopy and topography for brain and muscle clinical applications
Ferrari, M. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2804899 · Cited by 600
Strangman, G., Franceschini, M. A., & Boas, D. A. (2003) · NeuroImage · doi:10.1016/s1053-8119(03)00021-1 · Cited by 581
“Details on this hybrid frequency-domain (to measure the DPF) and continuous-wave (modified Beer–Lambert law) approach have been described elsewhere (Fantini et al., 1999).”
BackgroundSelf-citationBest practices for fNIRS publications
Yücel, M. A., Lühmann, A. V., Scholkmann, F., Gervain, J., Dan, I., Ayaz, H., Boas, D., Cooper, R. J., Culver, J., Elwell, C. E., et al. (2021) · Neurophotonics · doi:10.1117/1.nph.8.1.012101 · Cited by 492
Self-citationScholkmann, F., & Wolf, M. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.10.105004 · Cited by 450
“From the mathematical point of view, the dependence of d on the DPF is negligible when the inequality d ffiffiffiffiffiffiffiffiffiffiffi 3μaμ 0 s p ≫ 1 holds.(8) Since Eq.”
BackgroundCulver, J. P., Durduran, T., Furuya, D., Cheung, C., Greenberg, J. H., & Yodh, A. G. (2003) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/01.wcb.0000076703.71231.bb · Cited by 420
“…as the modified Beer-Lambert law (Kohl et al., 1998b; Nomura et al., 1997), in which one assumes or measures an effective total pathlength at a particular wavelength and optode separation (Delpy et al., 1988; Fantini et al., 1999; Hueber et al., 2001; Kohl et al., 1998b; Patterson et al., 1989).”
BackgroundA review of in‐vivo optical properties of human tissues and its impact on PDT
Sandell, J. L., & Zhu, T. C. (2011) · Journal of Biophotonics · doi:10.1002/jbio.201100062 · Cited by 384
Multimodal monitoring in traumatic brain injury: current status and future directions
Tisdall, M. M., & Smith, M. (2007) · British Journal of Anaesthesia · doi:10.1093/bja/aem143 · Cited by 365
Modified Beer-Lambert law for blood flow
Baker, W. B., Parthasarathy, A. B., Busch, D. R., Mesquita, R. C., Greenberg, J. H., & Yodh, A. G. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.004053 · Cited by 283
Beer–Lambert law for optical tissue diagnostics: current state of the art and the main limitations
Oshina, I., & Spigulis, J. (2021) · Journal of Biomedical Optics · doi:10.1117/1.jbo.26.10.100901 · Cited by 273
Three-dimensional optical tomography of hemodynamics in the human head
Bluestone, A. Y., Abdoulaev, G., Schmitz, C. H., Barbour, R. L., & Hielscher, A. H. (2001) · Optics Express · doi:10.1364/oe.9.000272 · Cited by 259
Near-Infrared Spectroscopy Cerebral Oxygen Saturation Thresholds for Hypoxia–Ischemia in Piglets
Kurth, C. D., Levy, W. J., & McCann, J. (2002) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1097/00004647-200203000-00011 · Cited by 236
“In many sick neonates, cerebral hemoglobin oxygenation is at or below the functional ScO2 threshold, indicating that cerebral hypoxia-ischemia may not be recognized during clinical care (Brun et al., 1997; Tsuji et al., 1998; Watzman et al., 2000; Kurth et al., 2001; Fantini et al., 1999; Springett et al., 2001).”
BackgroundMethodInfluentialWang, X., Tian, F., Soni, S. S., Gonzalez-Lima, F., & Liu, H. (2016) · Scientific Reports · doi:10.1038/srep30540 · Cited by 219
Chance, B., Nioka, S., Zhang, J., Conant, E. F., Hwang, E. M., Briest, S., Orel, S. G., Schnall, M. D., & Czerniecki, B. J. (2005) · Academic Radiology · doi:10.1016/j.acra.2005.04.016 · Cited by 202
“In this way the effect of demographic and other changes upon the cancer detection are minimized and an otherwise obscured diagnostic capability emerges based on the incremental cancer values with respect to cancer-free values ( 35 ).”
BackgroundMethodResultInfluentialSaager, R. B., Telleri, N. L., & Berger, A. J. (2011) · NeuroImage · doi:10.1016/j.neuroimage.2011.01.043 · Cited by 176
“A weak wavelength dependence is consistent with time- and phase-resolved pathlength measurements (Duncan et al., 1995; Fantini et al., 1999) and has been mentioned in other two-detector studies (Zhang et al.”
BackgroundDiffuse optical monitoring of hemodynamic changes in piglet brain with closed head injury
Zhou, C., Eucker, S. A., Durduran, T., Yu, G., Ralston, J., Friess, S. H., Ichord, R. N., Margulies, S. S., & Yodh, A. G. (2009) · Journal of Biomedical Optics · doi:10.1117/1.3146814 · Cited by 176
Hueber, D. M., Franceschini, M. A., Ma, H. Y., Zhang, Q., Ballesteros, J. R., Fantini, S., Wallace, D., Ntziachristos, V, & Chance, B. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/1/304 · Cited by 158
“As part of an earlier study, the same methodology was used to observe changing in absorption and scattering in a piglet head during and after the sacrifice of the piglet (via potassium induced cardiac arrest) ( Fantini et al 1999 ).”
MethodResultInfluentialSelf-citationFrequency-Domain Techniques for Cerebral and Functional Near-Infrared Spectroscopy
Fantini, S., & Sassaroli, A. (2020) · Frontiers in Neuroscience · doi:10.3389/fnins.2020.00300 · Cited by 134
“if the condition ρ √ 3μaμ ′ s 1 is fulfilled (Fantini et al., 1999).”
BackgroundMethodSelf-citationCerebral Oxygen Saturation-Time Threshold for Hypoxic-Ischemic Injury in Piglets
Kurth, C. D., McCann, J., Wu, J., Miles, L., & Loepke, A. W. (2009) · Anesthesia & Analgesia · doi:10.1213/ane.0b013e318196ac8e · Cited by 133
“from the instrument (measurement accuracy) or the individual (biological diversity).(8,9,17,19,23,25,26) The ScO2 threshold for neurophysiological impairment occurs”
BackgroundRoche‐Labarbe, N., Zaaimi, B., Berquin, P. C., Nehlig, A., Grebe, R., & Wallois, F. (2008) · Epilepsia · doi:10.1111/j.1528-1167.2008.01711.x · Cited by 126
“Changes in the absorption coefficient were calculated using the differential pathlength factor (DPF) method (Fantini et al., 1999).”
MethodPortable optical tissue flow oximeter based on diffuse correlation spectroscopy
Shang, Y., Zhao, Y., Cheng, R., Dong, L., Irwin, D., & Yu, G. (2009) · Optics Letters · doi:10.1364/ol.34.003556 · Cited by 122
Roche‐Labarbe, N., Wallois, F., Ponchel, E., Kongolo, G., & Grebe, R. (2007) · NeuroImage · doi:10.1016/j.neuroimage.2007.04.002 · Cited by 114
Noninvasive optical evaluation of spontaneous low frequency oscillations in cerebral hemodynamics
Cheng, R., Shang, Y., Hayes, D., Saha, S. P., & Yu, G. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.05.069 · Cited by 111
“The extinction coefficients were determined based on literature (Duncan et al., 1995) and DPF values were calculated using the measured absolute baseline values of μ a and μ s ′ (Fantini et al., 1999; Irwin et al., 2011), and were assumed constant over time.”
Farzam, P., Starkweather, Z., & Franceschini, M. A. (2018) · Physiological Reports · doi:10.14814/phy2.13664 · Cited by 107
“This result is somehow expected since the assumption of fixed scattering heavily affects the hemoglobin concentrations absolute values (Fantini et al. 1999).”
BackgroundSelf-citationLi, T., Lin, Y., Shang, Y., He, L., Huang, C., Szabunio, M. M., & Yu, G. (2013) · Scientific Reports · doi:10.1038/srep01358 · Cited by 103
Near infrared technology in neuroscience: past, present and future
Calderon‐Arnulphi, M., Alaraj, A. M., & Slavin, K. V. (2009) · Neurological Research · doi:10.1179/174313209x383286 · Cited by 102
Buckley, E. M., Hance, D. J., Lynch, J. M., Mesquita, R. C., Yodh, A. G., Licht, D. J., Pawlowski, T., Wilson, F. B., Fogel, M. A., Durduran, T., et al. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.3.037007 · Cited by 101
“ForDOSdataanalysis,themodified Beer-Lambertlaw, 22,23 was employed to compute changes in the absorption coefficient, Δ μ a ð λ Þ : μ a ð λ Þ is linearly dependent on the changes in concentrations of oxy-and deoxy-hemoglobin ( Δ HbO 2 and Δ Hb , respectively).”
MethodVirtanen, J., Kotilahti, K. M., Ilmoniemi, R. J., Noponen, T., & Virtanen, J. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3606576 · Cited by 101
Quaresima, V., Sacco, S., Totaro, R., & Ferrari, M. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429987 · Cited by 100
“9 Since the results obtained in animal models are not always transferable to humans, due to consistent anatomical differences, it is necessary to validate the NIRS devices directly in humans.”
Shen, Y., Lifante, J., Gutiérrez, I. Z., de la Fuente‐Fernández, M., Granado, M., Fernández, N., Rubio‐Retama, J., Jaque, D., Marin, R., Ximendes, E. C., et al. (2022) · Advanced Materials · doi:10.1002/adma.202107764 · Cited by 100
Dehaes, M., Grant, P. E., Sliva, D. D., Roche‐Labarbe, N., Pienaar, R., Boas, D. A., Franceschini, M. A., & Selb, J. J. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.000552 · Cited by 97
Self-citationPressure modulation algorithm to separate cerebral hemodynamic signals from extracerebral artifacts
Baker, W. B., Parthasarathy, A. B., Ko, T. S., Busch, D. R., Abramson, K., Tzeng, S.-Y., Mesquita, R. C., Durduran, T., Greenberg, J. H., Kung, D. K., et al. (2015) · Neurophotonics · doi:10.1117/1.nph.2.3.035004 · Cited by 95
Kolyva, C., Ghosh, A., Tachtsidis, I., Highton, D., Cooper, C. E., Smith, M., & Elwell, C. E. (2013) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.070 · Cited by 95
“…assumed to be equal to 6.26 for the two detectors proximal to the BB light source (source-detector spacing 2.0 and 2.5 cm) (Duncan et al., 1995) and was calculated for the two distal detectors (source-detector spacing 3.0 and 3.5 cm) using an initial FD measurement at 790 nm (Fantini et al., 1999).”
MethodInfluentialFranceschini, M. A., Boas, D. A., Zourabian, A., Diamond, S. G., Nadgir, S., Lin, D. W., Moore, J. B., & Fantini, S. (2002) · Journal of Applied Physiology · doi:10.1152/jappl.2002.92.1.372 · Cited by 95
Self-citationShang, Y., Cheng, R., Dong, L., Ryan, S., Saha, S. P., & Yu, G. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/10/008 · Cited by 91
“…spectroscopy (NIRS) offers a noninvasive, rapid, portable and low-cost alternative for direct monitoring of cerebral tissue oxygenation in microvasculature (Fantini et al 1999, Boas et al 2001, Culver et al 2005, Hebden et al 2004, Everdell et al 2005, Tian et al 2009, Franceschini et al 2006).”
Ferreira, L. F., Hueber, D. M., & Barstow, T. J. (2007) · Journal of Applied Physiology · doi:10.1152/japplphysiol.00920.2005 · Cited by 90
“The peak work rate achieved during the incremental exercise was 287 ± 63 W. DPF 690 830decreased slightly, but significantly from baseline (DPF = 5.22 ± 0.88; DPF = 4.49 ± 0.83) to 690 830peak exercise (DPF = 4.88 ± 0.86, DPF = 4.27 ± 0.80, P # 0.002 vs. baseline). sThe values of m’ for both wavelengths during baselin…”
BackgroundMethodInfluentialSelf-citationWall shear stress and strain modulate experimental aneurysm cellularity
Hoshina, K., Sho, E., Sho, M., Nakahashi, T. K., & Dalman, R. L. (2003) · Journal of Vascular Surgery · doi:10.1016/s0741-5214(03)70052-4 · Cited by 90
Calderon‐Arnulphi, M., Alaraj, A. M., Amin‐Hanjani, S., Mantulin, W. W., Polzonetti, C. M., Gratton, E., & Charbel, F. T. (2007) · Journal of neurosurgery · doi:10.3171/jns.2007.106.2.283 · Cited by 89
Self-citationWolf, U., Wolf, M., Choi, J. H., Levi, M., Choudhury, D., Hull, S., Coussirat, D. J., Paunescu, L. A., Safonova, L. P., Michalos, A., et al. (2003) · Journal of Vascular Surgery · doi:10.1067/mva.2003.214 · Cited by 86
“From these absolute values DPF can be calculated.(6)”
BackgroundMethodInfluentialSelf-citationVerdecchia, K., Diop, M., Lee, T., & Lawrence, K. S. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.2.027007 · Cited by 86
Recent Advances in Application of Cerebral Oximetry in Adult Cardiovascular Surgery
Fischer, G. W. (2008) · Seminars in Cardiothoracic and Vascular Anesthesia · doi:10.1177/1089253208316443 · Cited by 84
“By fitting the data to a diffusion model, the changes in chromophore concentrations can be calculated from attenuation changes.(37) The SR refers to a methodology used in some NIRS devices by measuring intensity changes at multiple light sources and detector spacings.”
MethodDiffuse optical monitoring of repeated cerebral ischemia in mice
Shang, Y., Chen, L., Toborek, M. J., & Yu, G. (2011) · Optics Express · doi:10.1364/oe.19.020301 · Cited by 82
Gurley, K., Shang, Y., & Yu, G. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.7.075010 · Cited by 81
“39 To reduce noise contributed by the phase component of the detected signals present in four-wavelength spatially-resolved analysis, relative changes (Δ[Hb], Δ1⁄2HbO2 ) were calculated with the data from two wavelengths (830 and 690 nm) at a separation of 2 cm using the modified Beer–Lambert method.(40) The Δ1⁄2Hb an…”
Toronov, V. Y., WEBB, A. G., Choi, J. H., Wolf, M., Safonova, L. P., Wolf, U., & Gratton, E. (2001) · Optics Express · doi:10.1364/oe.9.000417 · Cited by 81
Self-citationOptical measurements of absorption changes in two-layered diffusive media
Fabbri, F., Sassaroli, A., Henry, M., & Fantini, S. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/7/007 · Cited by 80
“In particular, the absorption coefficient is given by the following equation (Fantini et al 1999): µeffa = 2πf 2v ( S Sac − Sac S ) (3) where f is the modulation frequency, v is the speed of light in the medium and the superscript ‘eff’ indicates an effective absorption coefficient in the case of…”
Self-citationHallacoglu, B., Sassaroli, A., & Fantini, S. (2013) · PLoS ONE · doi:10.1371/journal.pone.0064095 · Cited by 78
Self-citationKolyva, C., Tachtsidis, I., Ghosh, A., Moroz, T., Cooper, C. E., Smith, M., & Elwell, C. E. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.002550 · Cited by 73
Casavola, C., Paunescu, L. A., Fantini, S., & Gratton, E. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429995 · Cited by 73
Self-citationZhao, J., Ding, H. S., Hou, X. L., Zhou, C. L., & Chance, B. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1891345 · Cited by 71
Dual-slope method for enhanced depth sensitivity in diffuse optical spectroscopy
Sassaroli, A., Blaney, G. P., & Fantini, S. (2019) · Journal of the Optical Society of America A · doi:10.1364/josaa.36.001743 · Cited by 71
Self-citationIjichi, S., Kusaka, T., Isobe, K., Islam, F., Okubo, K., Okada, H., Namba, M., Kawada, K., Imai, T., & Itoh, S. (2005) · Journal of Biomedical Optics · doi:10.1117/1.1899184 · Cited by 71
Yeganeh, H. Z., Toronov, V. Y., Elliott, J. T., Diop, M., Lee, T., & Lawrence, K. S. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.002761 · Cited by 71
Huang, R., Hong, K., Yang, D., & Huang, G. (2022) · Frontiers in Neuroscience · doi:10.3389/fnins.2022.878750 · Cited by 70
Cortical brain imaging by adaptive filtering of NIRS signals
Aqil, M., Hong, K., Jeong, M.-Y., & Ge, S. S. (2012) · Neuroscience Letters · doi:10.1016/j.neulet.2012.02.048 · Cited by 69
“Functional near-infrared spectroscopy (fNIRS) is a non-invasive robing technology for brain-activity monitoring, which meaures the absorbed quantity of near-infrared light of 650–950 nm avelength [1,4–6,8,13–15,20–22,24,25].”
Shang, Y., Symons, T. B., Durduran, T., Yodh, A. G., & Yu, G. (2010) · Biomedical Optics Express · doi:10.1364/boe.1.000500 · Cited by 68
Kamran, M. A., & Hong, K.-S. (2013) · Journal of Neural Engineering · doi:10.1088/1741-2560/10/5/056002 · Cited by 67
Mavroudis, C. D., Ko, T. S., Morgan, R. W., Volk, L. E., Landis, W. P., Smood, B. F., Xiao, R., Hefti, M. M., Boorady, T. W., Marquez, A. M., et al. (2020) · Critical Care · doi:10.1186/s13054-020-03297-4 · Cited by 67
Selb, J. J., Ogden, T. M., Dubb, J., Fang, Q., & Boas, D. A. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.1.016010 · Cited by 67
“11,13 It has been successfully applied to the monitoring of brain oxygenation and metabolism in healthy and brain-injured infants.”
Aqil, M., Hong, K., Jeong, M.-Y., & Ge, S. S. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.07.006 · Cited by 65
“…scale by solving Boltzmann's transport equation for absorption and reduced-scattering coefficients, if utilized in multi-distance configuration (Fantini et al., 1999); and ii) on a relative scale (similar to CW-fNIRS), if utilized in spatially distributed source–detector configuration…”
MethodGeneralized Beer–Lambert model for near-infrared light propagation in thick biological tissues
Bhatt, M., Ayyalasomayajula, K. R., & Yalavarthy, P. K. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.076012 · Cited by 65
“Equation (21) was fit to OD versus source–detector distance (d) data in MATLAB R2013b by nonlinear least square regression, which used the Levenberg–Marquardt algorithm(36) to determine the values of the two parameters μ0 and η.”
MethodSassaroli, A., Frederick, B. B., Tong, Y., Renshaw, P. F., & Fantini, S. (2006) · NeuroImage · doi:10.1016/j.neuroimage.2006.07.006 · Cited by 62
“Because the optical helmet is not devised for multi-distance measurements (Fantini et al., 1999) of the absolute optical properties, we have considered different values of k to study the sensitivity of the results on the choice of the effective attenuation coefficient.”
BackgroundSelf-citationActivation detection in diffuse optical imaging by means of the general linear model
Cohen‐Adad, J., Chapuisat, S., Doyon, J., Rossignol, S., Lina, J.-M., Benali, H., & Lesage, F. (2007) · Medical Image Analysis · doi:10.1016/j.media.2007.06.002 · Cited by 61
“Fantini et al. (1999) have allowed a better estimation of absorption and diffusion coefficients, an essential input to the imaging problem.”
BackgroundMethodYu, G., Durduran, T., Furuya, D., Greenberg, J. H., & Yodh, A. G. (2003) · Applied Optics · doi:10.1364/ao.42.002931 · Cited by 60
Age-correlated changes in cerebral hemodynamics assessed by near-infrared spectroscopy
Safonova, L. P., Michalos, A., Wolf, U., Wolf, M., Hueber, D. M., Choi, J. H., Gupta, R., Polzonetti, C. M., Mantulin, W. W., & Gratton, E. (2004) · Archives of Gerontology and Geriatrics · doi:10.1016/j.archger.2004.03.007 · Cited by 59
Self-citationIntraoperative Near‐Infrared Fluorescent Cholangiography (NIRFC) in Mouse Models of Bile Duct Injury
Figueiredo, J., Siegel, C. D., Nahrendorf, M., & Weissleder, R. (2009) · World Journal of Surgery · doi:10.1007/s00268-009-0332-8 · Cited by 58
“However, considering that the thickness of a normal human bile duct wall is 0.6 ± 0.3 mm and the wall thickness in a biliary obstruction situation is 0.8 ± 0.5 mm [26], the low penetration depth would be unlikely to pose a problem, and our strategy would therefore be suitable for laparoscopic cholecystectomy [ 35 ].”
MethodInfluentialPierro, M. L., Sassaroli, A., Bergethon, P. R., Ehrenberg, B. L., & Fantini, S. (2012) · NeuroImage · doi:10.1016/j.neuroimage.2012.07.015 · Cited by 58
“Specifically , the DPF was calculated by using explicit expressions as a function of the tissue optical properties, as derived from diffusion theory (Fantini et al., 1999).”
Self-citationSpatial sensitivity and penetration depth of three cerebral oxygenation monitors
Gunadi, S., Leung, T. S., Elwell, C. E., & Tachtsidis, I. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.002896 · Cited by 56
Yu, G., Shang, Y., Zhao, Y., Cheng, R., Dong, L., & Saha, S. P. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3533320 · Cited by 54
Munk, N., Symons, T. B., Shang, Y., Cheng, R., & Yu, G. (2011) · Journal of Bodywork and Movement Therapies · doi:10.1016/j.jbmt.2011.01.018 · Cited by 54
Blaney, G. P., Sassaroli, A., Pham, T., Fernandez, C. M., & Fantini, S. (2019) · Journal of Biophotonics · doi:10.1002/jbio.201960018 · Cited by 51
Self-citationBrain hypoxia, neurocognitive impairment, and quality of life in people post-COVID-19
Adingupu, D. D., Soroush, A., Hansen, A., Twomey, R., & Dunn, J. F. (2023) · Journal of Neurology · doi:10.1007/s00415-023-11767-2 · Cited by 49
Thomson, R. H., Cleve, T. J., Bailey, N. W., Rogasch, N. C., Maller, J. J., Daskalakis, Z. J., & Fitzgerald, P. B. (2013) · Brain Stimulation · doi:10.1016/j.brs.2012.12.001 · Cited by 49
“The Differential Pathlength Factor (DPF) and change in absorption were calculated from the AC and phase [27] and changes in HbO were then calculated with the extinction coefficients corresponding to the selected wavelengths [28].”
MethodHe, L., Lin, Y., Shang, Y., Shelton, B. J., & Yu, G. (2013) · Journal of Biomedical Optics · doi:10.1117/1.jbo.18.3.037001 · Cited by 49
“The relative change in the tissue absorption coefficient (Δμa) can be derived from the light intensity changes measured at the two wavelengths.(43) Variations of oxy- and deoxyhemoglobin concentrations (Δ1⁄2HbO2 and Δ1⁄2Hb ) relative to their baseline values (determined before physiological changes) can be resolved fr…”
MethodLi, T., Duan, M., Li, K., Yu, G., & Ruan, Z. (2015) · Biomedical Optics Express · doi:10.1364/boe.6.003431 · Cited by 47
Davies, D. J., Clancy, M. T., Lighter, D., Balanos, G. M., Lucas, S. J. E., Dehghani, H., Su, Z., Forcione, M., & Belli, A. (2016) · Journal of Clinical Monitoring and Computing · doi:10.1007/s10877-016-9942-5 · Cited by 47
“Specifically, observations regarding the shift in phase allow derivation of a more tissue specific value (quantification) of the degree of light scatter; hence the magnitude of this phenomenon is no longer assumed [8].”
Isobe, K., Kusaka, T., Fujikawa, Y., Kondo, M., Kawada, K., Yasuda, S., Itoh, S., Hirao, K., & Onishi, S. (2000) · Journal of Biomedical Optics · doi:10.1117/1.429997 · Cited by 47
Quaresima, V., Ferrari, M., Franceschini, M. A., Hoimes, M. L., & Fantini, S. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1646417 · Cited by 45
Self-citationPeripheral haemodynamics in newborns: Best practice guidelines
Weindling, M., & Paize, F. (2010) · Early Human Development · doi:10.1016/j.earlhumdev.2010.01.033 · Cited by 45
Ko, T. S., Mavroudis, C. D., Baker, W. B., Morano, V. C., Mensah-Brown, K. G., Boorady, T. W., Schmidt, A. L., Lynch, J. M., Busch, D. R., Gentile, J. I., et al. (2018) · Journal of Cerebral Blood Flow & Metabolism · doi:10.1177/0271678x18809828 · Cited by 45
Diop, M., Elliott, J. T., Tichauer, K. M., Lee, T., & Lawrence, K. S. (2009) · Review of Scientific Instruments · doi:10.1063/1.3123347 · Cited by 45
Roche‐Labarbe, N., Zaaimi, B., Mahmoudzadeh, M., Osharina, V., Wallois, A., Nehlig, A., Grebe, R., & Wallois, F. (2010) · Epilepsia · doi:10.1111/j.1528-1167.2010.02574.x · Cited by 44
“Changes in the absorption coefficient were calculated using the DPF (differential path–length factor) method (Fantini et al., 1999).”
MethodQuantitative measurements of cerebral blood flow with near-infrared spectroscopy
Pham, T., Tgavalekos, K. T., Sassaroli, A., Blaney, G. P., & Fantini, S. (2019) · Biomedical Optics Express · doi:10.1364/boe.10.002117 · Cited by 44
Self-citationChen, Y., Tailor, D. R., Intes, X., & Chance, B. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/4/301 · Cited by 41
“Theories and instruments have been developed to improve the measurement sensitivity and quantification accuracy of NIRS (Franceschini et al 2002, Hueber et al 2001, Fantini et al 1999, Ntziachristos et al 2000b, Ma et al 1999).”
MethodMedial frontal activity in brand-loyal consumers: A behavior and near-infrared ray study.
Lin, C.-H., Tuan, H.-P., & Chiu, Y.-C. (2010) · Journal of Neuroscience Psychology and Economics · doi:10.1037/a0015461 · Cited by 41
Wolf, U., Wolf, M., Choi, J. H., Paunescu, L. A., Safonova, L. P., Michalos, A., & Gratton, E. (2003) · Advances in experimental medicine and biology · doi:10.1007/978-1-4615-0205-0_37 · Cited by 41
Self-citationGatto, R. G., Hoffman, W. E., Mueller, M., Flores, A., Vályi-Nagy, T., & Charbel, F. T. (2006) · Journal of Neuroscience Methods · doi:10.1016/j.jneumeth.2006.04.013 · Cited by 41
Busch, D. R., Baker, W. B., Mavroudis, C. D., Ko, T. S., Lynch, J. M., McCarthy, A. L., Pont‐Thibodeau, G. D., Buckley, E. M., Jacobwitz, M., Boorady, T. W., et al. (2020) · Pediatric Research · doi:10.1038/s41390-020-0841-6 · Cited by 41
Non-invasive optical mapping of the piglet brain in real time
Fantini, S., Franceschini, M. A., Gratton, E., Hueber, D. M., Rosenfeld, W., Maulik, D., Stubblefield, P. G., & Stankovic, M. R. (1999) · Optics Express · doi:10.1364/oe.4.000308 · Cited by 41
Self-citationNoncontact diffuse correlation tomography of human breast tumor
He, L., Lin, Y., Huang, C., Irwin, D., Szabunio, M. M., & Yu, G. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.8.086003 · Cited by 40
Nelson, L. A., McCann, J., Loepke, A. W., Wu, J., Ben-Dor, B., & Kurth, C. D. (2006) · Journal of Biomedical Optics · doi:10.1117/1.2393251 · Cited by 38
“In laboratory settings, studies of frequency- and time-domain devices report accuracy similar to our study.(9,15,28) Studies of commercially available spatialdomain devices reveal poor agreement among the devices and less accuracy compared with our study.”
ResultOptical Properties of Wounds: Diabetic Versus Healthy Tissue
Papazoglou, E. S., Weingarten, M. S., Zubkov, L. A., Zhu, L., Tyagi, S., & Pourrezaei, K. (2006) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2006.873541 · Cited by 38
“The key difference among the various techniques lies in the source of incident light.”
BackgroundMartelli, F., Sassaroli, A., Bianco, S. D., & Zaccanti, G. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/10/013 · Cited by 38
“The results of more recent papers (Bevilacqua et al 1999, Fantini et al 1999, Sassaroli et al 2000, Johns et al 2005, Comelli et al 2007) suggest for µ′s lower values.”
BackgroundResultInfluentialLi, Z., Baker, W. B., Parthasarathy, A. B., Ko, T. S., Wang, D., Schenkel, S. S., Durduran, T., Li, G., & Yodh, A. G. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.12.125005 · Cited by 37
Open-source FlexNIRS: A low-cost, wireless and wearable cerebral health tracker
Wu, K.-C., Tamborini, D., Renna, M., Peruch, A., Huang, Y., Martin, A., Kaya, K., Starkweather, Z., Zavriyev, A. I., Carp, S. A., et al. (2022) · NeuroImage · doi:10.1016/j.neuroimage.2022.119216 · Cited by 37
Self-citationSassaroli, A., Martelli, F., Zaccanti, G., & Yamada, Y. (2001) · Applied Optics · doi:10.1364/ao.40.000185 · Cited by 37
Pierro, M. L., Kainerstorfer, J. M., Civiletto, A., Weiner, D. E., Sassaroli, A., Hallacoglu, B., & Fantini, S. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.2.026005 · Cited by 34
“Detected light intensity changes at 690 and 830 nm were translated into oxy- and deoxyhemoglobin concentrations in tissue (O and D) by utilizing the modified Beer–Lambert law(34) with a differential pathlength factor (DPF) obtained by using diffusion theory expressions in terms of the tissue optical properties.(35) We…”
MethodSelf-citationApplications of Near‐Infrared Spectroscopy in Medical Sciences
Heise, H. M. (2001) · Wiley eBooks · doi:10.1002/9783527612666.ch13 · Cited by 34
Dual-Slope Diffuse Reflectance Instrument for Calibration-Free Broadband Spectroscopy
Blaney, G. P., Donaldson, R., Mushtak, S., Nguyen, H. T. N., Vignale, L., Fernandez, C. M., Pham, T., Sassaroli, A., & Fantini, S. (2021) · Applied Sciences · doi:10.3390/app11041757 · Cited by 33
“This guess was determined based on the linear slopes of complex reflectance amplitude and phase as previously described [19,21].”
MethodSelf-citationHuang, C., Radabaugh, J. P., Aouad, R. K., Lin, Y., Gal, T. J., Patel, A., Valentino, J. P., Shang, Y., & Yu, G. (2015) · Journal of Biomedical Optics · doi:10.1117/1.jbo.20.7.075008 · Cited by 33
Using Wireless Near-Infrared Spectroscopy to Predict Wound Prognosis in Diabetic Foot Ulcers
Lin, B., Chang, C., Tseng, Y., Li, J.-R., Peng, Y.-S., & Huang, Y. (2019) · Advances in Skin & Wound Care · doi:10.1097/01.asw.0000613552.50065.d5 · Cited by 32
“Therefore, the diffusely reflected light contained physiologic information related to the biologic tissues through which it penetrated.(17,18)”
Background
Metadata
- Authors
- Fantini, S., Hueber, D., Franceschini, M. A., Gratton, E., Rosenfeld, W., Stubblefield, P. G., Maulik, D., & Stankovic, M. R.
- Affiliations
- University of Illinois Urbana-Champaign (US)
- International Space Station (US)
- Winthrop-University Hospital (US)
- Boston University (US)
- Boston Medical Center (US)
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 1999-01-01
- Volume
- 44
- Issue
- 6
- Pages
- 1543-1563
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2005686740
- Semantic Scholar
- 33e572f124903d86d761f0e4ed6fd287d63a48ab
- Cited by
- 277
- References
- 62
- Citations by year
- 2026: 6 · 2025: 8 · 2024: 10 · 2023: 13 · 2022: 11 · 2021: 20 · 2020: 15 · 2019: 8 · 2018: 4 · 2017: 3 · 2016: 6 · 2015: 13 · 2014: 8 · 2013: 12 · 2012: 23
- FWCI
- 8.00
- Type
- journal article
- Language
- en
- Open access
- green
- escholarship.org
- Licence
- cc-by
- Locations
- Physics in Medicine and Biology (publishedVersion)
- PubMed (publishedVersion)
- eScholarship (California Digital Library) (submittedVersion, cc-by)
- Funders
- National Institutes of Health (5r01rr010966-06, 5r01ca057032-08)
- National Cancer Institute (CA 57032)
- National Center for Research Resources (RR 10966)
- Topics
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Life Sciences › Biochemistry, Genetics and Molecular Biology › Biophysics › Spectroscopy Techniques in Biomedical and Chemical Research
- Keywords
- reduced scattering coefficient, frequency domain spectroscopy, continuous-wave spectroscopy, carotid artery occlusion, cerebral hemodynamics, cerebral oxygenation, motion artifacts
- MeSH terms
- Animals, Animals, Newborn, Asphyxia, Brain, Hemoglobins, Models, Theoretical, Radiography, Swine, Time Factors, Reproducibility of Results, Carotid Stenosis, Spectroscopy, Near-Infrared
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.