The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Distance-driven projection and backprojection in three dimensions
Abstract
Projection and backprojection are operations that arise frequently in tomographic imaging. Recently, we proposed a new method for projection and backprojection, which we call distance-driven, and that offers low arithmetic cost and a highly sequential memory access pattern. Furthermore, distance-driven projection and backprojection avoid several artefact-inducing approximations characteristic of some other methods. We have previously demonstrated the application of this method to parallel and fan beam geometries. In this paper, we extend the distance-driven framework to three dimensions and demonstrate its application to cone beam reconstruction. We also present experimental results to demonstrate the computational performance, the artefact characteristics and the noise-resolution characteristics of the distance-driven method in three dimensions.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Feldkamp, L. A., Davis, L. C., & Kress, J. W. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000612 · Cited by 6,319
Fast calculation of the exact radiological path for a three‐dimensional CT array
Siddon, R. L. (1985) · Medical Physics · doi:10.1118/1.595715 · Cited by 1,535
Fast volume rendering using a shear-warp factorization of the viewing transformation
Lacroute, P., & Levoy, M. (1994) · Proceedings of the 21st annual conference on Computer graphics and interactive techniques - SIGGRAPH '94 · doi:10.1145/192161.192283 · Cited by 1,013
Image Reconstruction from Projections
(2004) · Biomedical Engineering · doi:10.1201/9780203492543.ch9 · Cited by 915
Penalized weighted least-squares image reconstruction for positron emission tomography
Fessler, J. A. (1994) · IEEE Transactions on Medical Imaging · doi:10.1109/42.293921 · Cited by 611
An iterative maximum-likelihood polychromatic algorithm for CT
De Man, B., Nuyts, J., Dupont, P., Marchal, G., & Suetens, P. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.959297 · Cited by 430
An Improved Algorithm for Reprojecting Rays through Pixel Images
Joseph, P. M. (1982) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.1982.4307572 · Cited by 375
Fundamentals of Medical Imaging
Suetens, P. (2009) · Cambridge University Press eBooks · doi:10.1017/cbo9780511596803 · Cited by 344
Metal streak artifacts in X-ray computed tomography: a simulation study
De Man, B., Nuyts, J., Dupont, P., Marchal, G., & Suetens, P. (1999) · IEEE Transactions on Nuclear Science · doi:10.1109/23.775600 · Cited by 311
Iterative reconstruction for helical CT: a simulation study
Nuyts, J., Man, B. D., Dupont, P., Defrise, M., Suetens, P., & Mortelmans, L. (1998) · Physics in Medicine and Biology · doi:10.1088/0031-9155/43/4/003 · Cited by 291
Self-citationAn iterative approach to the beam hardening correction in cone beam CT
Hsieh, J., Molthen, R. C., Dawson, C. A., & Johnson, R. H. (2000) · Medical Physics · doi:10.1118/1.598853 · Cited by 280
Zwicker, M., Pfister, H., van Baar, J., & Gross, M. (2002) · IEEE Transactions on Visualization and Computer Graphics · doi:10.1109/tvcg.2002.1021576 · Cited by 270
Unmatched projector/backprojector pairs in an iterative reconstruction algorithm
Zeng, G. L., & Gullberg, G. T. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.870265 · Cited by 228
Image Reconstruction from Projections
Norton-Wayne, L. (1980) · Optica Acta: International Journal of Optics · doi:10.1080/713820221 · Cited by 184
O(N/sup 2/log/sub 2/N) filtered backprojection reconstruction algorithm for tomography
Basu, S., & Bresler, Y. (2000) · IEEE Transactions on Image Processing · doi:10.1109/83.869187 · Cited by 175
Self-citationFast implementations of algebraic methods for three-dimensional reconstruction from cone-beam data
Mueller, K., Yagel, R., & Wheller, J. J. (1999) · IEEE Transactions on Medical Imaging · doi:10.1109/42.781018 · Cited by 74
Incremental algorithm-a new fast backprojection scheme for parallel beam geometries
Cho, Z. H., Chen, C., & Lee, S. (1990) · IEEE Transactions on Medical Imaging · doi:10.1109/42.56333 · Cited by 49
Cited by
Yang, Q., Yan, P., Zhang, Y., Yu, H., Shi, Y., Mou, X., Kalra, M. K., Zhang, Y., Sun, L., & Wang, G. (2018) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2827462 · Cited by 1,630
Schulze, R., Heil, U., Groβ, D., Bruellmann, D., Dranischnikow, E., Schwanecke, U., & Schoemer, E. (2011) · Dentomaxillofacial Radiology · doi:10.1259/dmfr/30642039 · Cited by 999
A three‐dimensional statistical approach to improved image quality for multislice helical CT
Thibault, J., Sauer, K. D., Bouman, C. A., & Hsieh, J. (2007) · Medical Physics · doi:10.1118/1.2789499 · Cited by 937
Iterative reconstruction methods in X-ray CT
Beister, M., Kolditz, D., & Kalender, W. A. (2012) · Physica Medica · doi:10.1016/j.ejmp.2012.01.003 · Cited by 751
Low-Dose X-ray CT Reconstruction via Dictionary Learning
Xu, Q., Yu, H., Mou, X., Zhang, L., Hsieh, J., & Wang, G. (2012) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2012.2195669 · Cited by 690
Metadata
- Authors
- Man, B. D., & Basu, S.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2004-05-20
- Volume
- 49
- Issue
- 11
- Pages
- 2463-2475
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2068454934
- Cited by
- 459
- References
- 17
- FWCI
- 7.49
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.