Image-guidance for surgical procedures
The DOI matches its Crossref record; 105 of the 105 references it cites were found in a registry or an index.
Abstract
Contemporary imaging modalities can now provide the surgeon with high quality three- and four-dimensional images depicting not only normal anatomy and pathology, but also vascularity and function. A key component of image-guided surgery (IGS) is the ability to register multi-modal pre-operative images to each other and to the patient. The other important component of IGS is the ability to track instruments in real time during the procedure and to display them as part of a realistic model of the operative volume. Stereoscopic, virtual- and augmented-reality techniques have been implemented to enhance the visualization and guidance process. For the most part, IGS relies on the assumption that the pre-operatively acquired images used to guide the surgery accurately represent the morphology of the tissue during the procedure. This assumption may not necessarily be valid, and so intra-operative real-time imaging using interventional MRI, ultrasound, video and electrophysiological recordings are often employed to ameliorate this situation. Although IGS is now in extensive routine clinical use in neurosurgery and is gaining ground in other surgical disciplines, there remain many drawbacks that must be overcome before it can be employed in more general minimally-invasive procedures. This review overviews the roots of IGS in neurosurgery, provides examples of its use outside the brain, discusses the infrastructure required for successful implementation of IGS approaches and outlines the challenges that must be overcome for IGS to advance further.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Co-Planar Stereotaxic Atlas of the Human Brain
Talairach, J., & Tournoux, P. (1988) · Medical Entomology and Zoology · Cited by 11,798
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · Proceedings of the 14th annual conference on Computer graphics and interactive techniques · doi:10.1145/37401.37422 · Cited by 10,104
Marching cubes: A high resolution 3D surface construction algorithm
Lorensen, W. E., & Cline, H. E. (1987) · ACM SIGGRAPH Computer Graphics · doi:10.1145/37402.37422 · Cited by 8,647
Co-planar stereotaxic atlas of the human brain
Laitinen, L. (1989) · Clinical Neurology and Neurosurgery · doi:10.1016/0303-8467(89)90128-5 · Cited by 7,565
A survey of medical image registration
Maintz, J. B. A., & Viergever, M. A. (1998) · Medical Image Analysis · doi:10.1016/s1361-8415(01)80026-8 · Cited by 3,327
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093 · cited 1×
“To achieve this latter aim, the video image produced by the endoscope may be mapped onto an interior surface model explored by the endoscope (Dey et al 2002). A similar approach has been described by Szpala et al (2005) for registering endoscopic images with pre-operatively acquired dynamic models of the beating heart.”
MethodDrebin, R. A., Carpenter, L., & Hanrahan, P. (1988) · ACM SIGGRAPH Computer Graphics · doi:10.1145/378456.378484 · Cited by 1,612
Accurate Three-Dimensional Registration of CT, PET, and/or MR Images of the Brain
Pelizzari, C. A., Chen, G. T. Y., Spelbring, D. R., Weichselbaum, R. R., & Chen, C.-T. (1989) · Journal of Computer Assisted Tomography · doi:10.1097/00004728-198901000-00004 · Cited by 1,096
Predicting error in rigid-body point-based registration
Fitzpatrick, J. M., West, J. B., & Maurer, C. R. (1998) · IEEE Transactions on Medical Imaging · doi:10.1109/42.736021 · Cited by 1,010
Stereotaxic Apparatus for Operations on the Human Brain
Spiegel, E. A., Wycis, H. T., Marks, M., & Lee, A. J. (1947) · Science · doi:10.1126/science.106.2754.349 · Cited by 982
Cited by
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“In the case of surgical operations, providing a continuous real-time mapping between interventional data (often 2D) and images used for planning (CT/MR) would have a great impact and help ensure the success of surgery [10 12].”
BackgroundA Review of 3d/2d Registration Methods for Image-Guided Interventions
Markelj, P., Tomaževič, D., Likar, B., & Pernuš, F. (2012) · Medical Image Analysis · doi:10.1016/j.media.2010.03.005 · Cited by 746
“…these images and treatment plan) and intra-intervention data (patient’s images, positions of tools, radiation fields, etc.) into the same coordinate frame (Peters, 2006; Sauer, 2005; Galloway, 2001; DiMaio et al., 2007; Yaniv and Cleary, 2006; Romanelli et al., 2006a,b; Avanzo and Romanelli, 2009).”
BackgroundInfluentialThe status of augmented reality in laparoscopic surgery as of 2016
Bernhardt, S., Nicolau, S. A., Soler, L., & Doignon, C. (2017) · Medical Image Analysis · doi:10.1016/j.media.2017.01.007 · Cited by 314
Virtual reality training in neurosurgery: Review of current status and future applications
Alaraj, A., Lemole, M., Finkle, J., Yudkowsky, R., Wallace, A., Luciano, C., Banerjee, P., Rizzi, S., & Charbel, F. (2011) · Surgical Neurology International · doi:10.4103/2152-7806.80117 · Cited by 204
Three-Dimensional Tissue Deformation Recovery and Tracking
Mountney, P., Stoyanov, D., & Yang, G.-Z. (2010) · IEEE Signal Processing Magazine · doi:10.1109/msp.2010.936728 · Cited by 188
Navigation in Endoscopic Soft Tissue Surgery: Perspectives and Limitations
Baumhauer, M., Feuerstein, M., Meinzer, H.-P., & Rassweiler, J. (2008) · Journal of Endourology · doi:10.1089/end.2007.9827 · Cited by 181
Weakly supervised machine learning
Ren, Z., Wang, S., & Zhang, Y. (2023) · CAAI Transactions on Intelligence Technology · doi:10.1049/cit2.12216 · Cited by 163
Three-dimensional ultrasound imaging
Prager, R. W., Ijaz, U. Z., Gee, A. H., & Treece, G. M. (2010) · Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine · doi:10.1243/09544119jeim586 · Cited by 162
4D interventional device reconstruction from biplane fluoroscopy
Wagner, M., Schafer, S., Strother, C., & Mistretta, C. (2016) · Medical Physics · doi:10.1118/1.4941950 · Cited by 48
Gendrin, C., Markelj, P., Pawiro, S. A., Spoerk, J., Bloch, C., Weber, C., Figl, M., Bergmann, H., Birkfellner, W., Likar, B., et al. (2011) · Medical Physics · doi:10.1118/1.3553403 · Cited by 38
Metadata
- Authors
- Peters, T. M.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2006-06-26
- Volume
- 51
- Issue
- 14
- Pages
- R505-R540
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2042641515
- Cited by
- 249
- References
- 105
- FWCI
- 23.13
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.