A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Expert landmark correspondences are widely reported for evaluating deformable image registration (DIR) spatial accuracy. In this report, we present a framework for objective evaluation of DIR spatial accuracy using large sets of expert-determined landmark point pairs. Large samples (>1100) of pulmonary landmark point pairs were manually generated for five cases. Estimates of inter- and intra-observer variation were determined from repeated registration. Comparative evaluation of DIR spatial accuracy was performed for two algorithms, a gradient-based optical flow algorithm and a landmark-based moving least-squares algorithm. The uncertainty of spatial error estimates was found to be inversely proportional to the square root of the number of landmark point pairs and directly proportional to the standard deviation of the spatial errors. Using the statistical properties of this data, we performed sample size calculations to estimate the average spatial accuracy of each algorithm with 95% confidence intervals within a 0.5 mm range. For the optical flow and moving least-squares algorithms, the required sample sizes were 1050 and 36, respectively. Comparative evaluation based on fewer than the required validation landmarks results in misrepresentation of the relative spatial accuracy. This study demonstrates that landmark pairs can be used to assess DIR spatial accuracy within a narrow uncertainty range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
Horn, B. K. P., & Schunck, B. G. (1981) · Artificial Intelligence · doi:10.1016/0004-3702(81)90024-2 · Cited by 10,312
Horn, B. K., & Schunck, B. G. (1981) · SPIE Proceedings · doi:10.1117/12.965761 · Cited by 7,394
Casella, G., & Berger, R. (2024) · Chapman & Hall/CRC eBooks · doi:10.1201/9781003456285 · Cited by 5,711
Gomarasca, M. A. (2009) · Basics of Geomatics · doi:10.1007/978-1-4020-9014-1_8 · Cited by 2,614
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Crimins, F. (2003) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-003-0001-6 · Cited by 2,000
The computation of optical flow
Beauchemin, S. S., & Barron, J. L. (1995) · ACM Computing Surveys · doi:10.1145/212094.212141 · Cited by 1,278
Image deformation using moving least squares
Schaefer, S., McPhail, T., & Warren, J. (2006) · ACM Transactions on Graphics · doi:10.1145/1141911.1141920 · Cited by 674
Self-citationWang, H., Dong, L., O'Daniel, J., Mohan, R., Garden, A. S., Ang, K. K., Kuban, D. A., Bonnen, M., Chang, J. Y., & Cheung, R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/12/011 · Cited by 610
Cited by
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“One may cite the POPI model [452] containing 40 landmarks in every frame of a 4 D lung CT acquisition, or the 4 D CT dataset made available by Castillo et al. [453] with landmarks in the maximum inhale and exhale phase.”
MethodBrock, K. K., Mutic, S., McNutt, T. R., Li, H., & Kessler, M. L. (2017) · Medical Physics · doi:10.1002/mp.12256 · Cited by 881
A deep learning framework for unsupervised affine and deformable image registration
de Vos, B. D., Berendsen, F. F., Viergever, M. A., Sokooti, H., Staring, M., & Išgum, I. (2019) · Medical Image Analysis · doi:10.1016/j.media.2018.11.010 · Cited by 818
MIND: Modality independent neighbourhood descriptor for multi-modal deformable registration
Heinrich, M. P., Jenkinson, M., Bhushan, M., Matin, T., Gleeson, F. V., Brady, S. M., & Schnabel, J. A. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.05.008 · Cited by 707
Deep learning in medical image registration: a review
Fu, Y., Lei, Y., Wang, T., Curran, W. J., Liu, T., & Yang, X. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab843e · Cited by 661
“08 mm TRE on DIRLAB [12], which was much worse than 1.”
BackgroundMethodEvaluation of Registration Methods on Thoracic CT: The EMPIRE10 Challenge
Murphy, K., van Ginneken, B., Reinhardt, J. M., Kabus, S., Ding, K., Deng, X., Cao, K., Du, K., Christensen, G. E., Garcia, V., et al. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2158349 · Cited by 440
MRF-Based Deformable Registration and Ventilation Estimation of Lung CT
Heinrich, H. P., Jenkinson, M., Brady, M., & Schnabel, J. A. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2246577 · Cited by 311
The ANACONDA algorithm for deformable image registration in radiotherapy
Weistrand, O., & Svensson, S. (2015) · Medical Physics · doi:10.1118/1.4894702 · Cited by 284
Four-dimensional deformable image registration using trajectory modeling
Castillo, E., Castillo, R., Martinez, J., Shenoy, M., & Guerrero, T. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/1/018 · Cited by 261
Self-citationHering, A., Hansen, L., Mok, T. C. W., Chung, A. C. S., Siebert, H., Hager, S., Lange, A., Kuckertz, S., Heldmann, S., Shao, W., et al. (2023) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2022.3213983 · Cited by 250
“The DIR-Lab datasets [13] have been widely used to benchmark intra-patient CT lung motion estimation and provide a leaderboard for state-of-theart comparison.”
MethodImplementation and evaluation of various demons deformable image registration algorithms on a GPU
Gu, X., Pan, H., Liang, Y., Castillo, R., Yang, D., Choi, D., Castillo, E., Majumdar, A., Guerrero, T., & Jiang, S. B. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/1/012 · Cited by 243
“The performance of the implemented demons algorithms was assessed using thoracic 4D CT images obtained from five clinical cases (Castillo et al. , 2009).”
MethodSelf-citationMetz, C. T., Klein, S., Schaap, M., van Walsum, T., & Niessen, W. J. (2011) · Medical Image Analysis · doi:10.1016/j.media.2010.10.003 · Cited by 236
“, 2007) and DIR-lab data were used (Castillo et al., 2009).”
MethodPulmonary CT Registration Through Supervised Learning With Convolutional Neural Networks
Eppenhof, K. A. J., & Pluim, J. P. W. (2019) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2018.2878316 · Cited by 173
“To validate our methodology and test generalization to different data, we use the trained network to register expiration images (moving) to inspiration images (fixed) from a separate set of test data, the DIR-Lab dataset [17], [18].”
MethodOu, Y., Akbari, H., Bilello, M., Da, X., & Davatzikos, C. (2014) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2014.2330355 · Cited by 171
PCA-based groupwise image registration for quantitative MRI
Huizinga, W., Poot, D. H. J., Guyader, J.-M., Klaassen, R., Coolen, B. F., van Kranenburg, M., van Geuns, R. J. M., Uitterdijk, A., Polfliet, M., Vandemeulebroucke, J., et al. (2016) · Medical Image Analysis · doi:10.1016/j.media.2015.12.004 · Cited by 170
“Ten 4D CT lung datasets from the DIR-LAB database (Castillo et al., 2009) were used to demonstrate the results of the meth-ods on datasets with only slight intensity changes.”
Chen, J., Liu, Y., Wei, S., Bian, Z., Subramanian, S., Carass, A., Prince, J. L., & Du, Y. (2025) · Medical Image Analysis · doi:10.1016/j.media.2024.103385 · Cited by 167
Deep Learning in Medical Image Registration
Chen, X., Diaz-Pinto, A., Ravikumar, N., & Frangi, A. (2020) · Progress in Biomedical Engineering · doi:10.1088/2516-1091/abd37c · Cited by 106
A review of deep learning-based deformable medical image registration
Zou, J., Gao, B., Song, Y., & Qin, J. (2022) · Frontiers in Oncology · doi:10.3389/fonc.2022.1047215 · Cited by 126
“DirLAB (42) CT Lung 3D 10 2009 Normal 300 landmarks”
BackgroundA review of deep learning-based three-dimensional medical image registration methods
Xiao, H., Teng, X., Liu, C., Li, T., Ren, G., Yang, R., Shen, D., & Cai, J. (2021) · Quantitative Imaging in Medicine and Surgery · doi:10.21037/qims-21-175 · Cited by 77
The truth is hard to make: Validation of medical image registration
Pluim, J. P. W., Muenzing, S. E. A., Eppenhof, K. A. J., & Murphy, K. (2016) · 2016 23rd International Conference on Pattern Recognition (ICPR) · doi:10.1109/icpr.2016.7899978 · Cited by 34
“• Dir-lab (the University of Texas Medical Branch) [18]: lung CT, both 4D and inspiration-expiration, with manually identified landmarks, http://www.”
BackgroundMethod
Metadata
- Authors
- Castillo, R., Castillo, E., Guerra, R., Johnson, V. E., McPhail, T., Garg, A. K., & Guerrero, T.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2009-03-05
- Volume
- 54
- Issue
- 7
- Pages
- 1849-1870
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2065319605
- Cited by
- 592
- References
- 30
- FWCI
- 23.32
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.