A framework for evaluation of deformable image registration spatial accuracy using large landmark point sets
Open accessThe DOI matches its Crossref record; 30 of the 30 references it cites were found in a registry or an index.
Abstract
Expert landmark correspondences are widely reported for evaluating deformable image registration (DIR) spatial accuracy. In this report, we present a framework for objective evaluation of DIR spatial accuracy using large sets of expert-determined landmark point pairs. Large samples (>1100) of pulmonary landmark point pairs were manually generated for five cases. Estimates of inter- and intra-observer variation were determined from repeated registration. Comparative evaluation of DIR spatial accuracy was performed for two algorithms, a gradient-based optical flow algorithm and a landmark-based moving least-squares algorithm. The uncertainty of spatial error estimates was found to be inversely proportional to the square root of the number of landmark point pairs and directly proportional to the standard deviation of the spatial errors. Using the statistical properties of this data, we performed sample size calculations to estimate the average spatial accuracy of each algorithm with 95% confidence intervals within a 0.5 mm range. For the optical flow and moving least-squares algorithms, the required sample sizes were 1050 and 36, respectively. Comparative evaluation based on fewer than the required validation landmarks results in misrepresentation of the relative spatial accuracy. This study demonstrates that landmark pairs can be used to assess DIR spatial accuracy within a narrow uncertainty range.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Numerical recipes in C: the art of scientific computing
(1993) · Choice Reviews Online · doi:10.5860/choice.30-5638 · Cited by 17,933
Horn, B. K. P., & Schunck, B. G. (1981) · Artificial Intelligence · doi:10.1016/0004-3702(81)90024-2 · Cited by 10,312
Horn, B. K., & Schunck, B. G. (1981) · SPIE Proceedings · doi:10.1117/12.965761 · Cited by 7,394
Casella, G., & Berger, R. (2024) · Chapman & Hall/CRC eBooks · doi:10.1201/9781003456285 · Cited by 5,711
Gomarasca, M. A. (2009) · Basics of Geomatics · doi:10.1007/978-1-4020-9014-1_8 · Cited by 2,614
Hill, D. L. G., Batchelor, P. G., Holden, M., & Hawkes, D. J. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/3/201 · Cited by 2,093
Crimins, F. (2003) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-003-0001-6 · Cited by 2,000
The computation of optical flow
Beauchemin, S. S., & Barron, J. L. (1995) · ACM Computing Surveys · doi:10.1145/212094.212141 · Cited by 1,278
Image deformation using moving least squares
Schaefer, S., McPhail, T., & Warren, J. (2006) · ACM Transactions on Graphics · doi:10.1145/1141911.1141920 · Cited by 674
Self-citationWang, H., Dong, L., O'Daniel, J., Mohan, R., Garden, A. S., Ang, K. K., Kuban, D. A., Bonnen, M., Chang, J. Y., & Cheung, R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/12/011 · Cited by 610
Accuracy of finite element model‐based multi‐organ deformable image registration
Brock, K. K., Sharpe, M. B., Dawson, L. A., Kim, S. M., & Jaffray, D. A. (2005) · Medical Physics · doi:10.1118/1.1915012 · Cited by 375
Fast free-form deformable registration via calculus of variations
Lu, W., Chen, M.-L., Olivera, G. H., Ruchala, K. J., & Mackie, T. R. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/14/003 · Cited by 259
(2002) · Understanding Social Science Research · doi:10.4135/9780857020208.n7 · Cited by 195
Wang, H., Dong, L., Lii, M. F., Lee, A. L., de Crevoisier, R., Mohan, R., Cox, J. D., Kuban, D. A., & Cheung, R. (2005) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2004.07.677 · Cited by 181
Respiratory Motion Correction in 3-D PET Data With Advanced Optical Flow Algorithms
Dawood, M., Buther, F., Jiang, X., & Schafers, K. P. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.918321 · Cited by 179
Boldea, V., Sharp, G. C., Jiang, S. B., & Sarrut, D. (2008) · Medical Physics · doi:10.1118/1.2839103 · Cited by 167
Assessment of a model-based deformable image registration approach for radiation therapy planning.
Kaus, M., Brock, K., Pekar, V., Dawson, L., Nichol, A., & Jaffray, D. (2007) · International Journal of Radiation Oncology, Biology, Physics · doi:10.1016/j.ijrobp.2007.01.056 · Cited by 162
Lu, W., Olivera, G. H., Chen, Q., Ruchala, K. J., Haimerl, J., Meeks, S. L., Langen, K. M., & Kupelian, P. A. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/17/015 · Cited by 159
Wolthaus, J., Sonke, J., van Herk, M., & Damen, E. M. F. (2008) · Medical Physics · doi:10.1118/1.2966347 · Cited by 157
Evaluation of deformable registration of patient lung 4DCT with subanatomical region segmentations
Wu, Z., Rietzel, E., Boldea, V., Sarrut, D., & Sharp, G. C. (2008) · Medical Physics · doi:10.1118/1.2828378 · Cited by 151
Sarrut, D., Boldea, V., Miguet, S., & Ginestet, C. (2006) · Medical Physics · doi:10.1118/1.2161409 · Cited by 150
Coselmon, M. M., Balter, J. M., McShan, D. L., & Kessler, M. L. (2004) · Medical Physics · doi:10.1118/1.1803671 · Cited by 134
Contact surface and material nonlinearity modeling of human lungs
Al-Mayah, A., Moseley, J., & Brock, K. K. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/1/022 · Cited by 112
Deformable registration of 4D computed tomography data
Rietzel, E., & Chen, G. T. Y. (2006) · Medical Physics · doi:10.1118/1.2361077 · Cited by 102
Pevsner, A., Davis, B., Joshi, S. C., Hertanto, A., Mechalakos, J., Yorke, E. D., Rosenzweig, K., Nehmeh, S. A., Erdi, Y. E., Humm, J. L., et al. (2006) · Medical Physics · doi:10.1118/1.2161408 · Cited by 67
FEM-based evaluation of deformable image registration for radiation therapy
Zhong, H., Peters, T. M., & Siebers, J. V. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/16/001 · Cited by 60
A Comparison Framework for Breathing Motion Estimation Methods From 4-D Imaging
Sarrut, D., Delhay, S., Villard, P.-F., Boldea, V., Beuve, M., & Clarysse, P. (2007) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2007.901006 · Cited by 54
Accuracy and sensitivity of finite element model‐based deformable registration of the prostate
Brock, K. K., Nichol, A., Ménard, C. M., Moseley, J. L., Warde, P. R., Catton, C., & Jaffray, D. A. (2008) · Medical Physics · doi:10.1118/1.2965263 · Cited by 50
Quality Assurance of Serial 3D Image Registration, Fusion, and Segmentation
Sharpe, M., & Brock, K. K. (2008) · International Journal of Radiation Oncology*Biology*Physics · doi:10.1016/j.ijrobp.2007.06.087 · Cited by 34
Performance evaluation of medical image processing algorithms
Gee, J. C. (2000) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.387682 · Cited by 16
Cited by
Deformable medical image registration: a survey
Sotiras, A., Davatzikos, C., & Paragios, N. (2013) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2013.2265603 · Cited by 1,587
“One may cite the POPI model [452] containing 40 landmarks in every frame of a 4 D lung CT acquisition, or the 4 D CT dataset made available by Castillo et al. [453] with landmarks in the maximum inhale and exhale phase.”
MethodBrock, K. K., Mutic, S., McNutt, T. R., Li, H., & Kessler, M. L. (2017) · Medical Physics · doi:10.1002/mp.12256 · Cited by 881
A deep learning framework for unsupervised affine and deformable image registration
de Vos, B. D., Berendsen, F. F., Viergever, M. A., Sokooti, H., Staring, M., & Išgum, I. (2019) · Medical Image Analysis · doi:10.1016/j.media.2018.11.010 · Cited by 818
MIND: Modality independent neighbourhood descriptor for multi-modal deformable registration
Heinrich, M. P., Jenkinson, M., Bhushan, M., Matin, T., Gleeson, F. V., Brady, S. M., & Schnabel, J. A. (2012) · Medical Image Analysis · doi:10.1016/j.media.2012.05.008 · Cited by 707
Deep learning in medical image registration: a review
Fu, Y., Lei, Y., Wang, T., Curran, W. J., Liu, T., & Yang, X. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/ab843e · Cited by 661
“08 mm TRE on DIRLAB [12], which was much worse than 1.”
BackgroundMethod
Metadata
- Authors
- Castillo, R., Castillo, E., Guerra, R., Johnson, V. E., McPhail, T., Garg, A. K., & Guerrero, T.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2009-03-05
- Volume
- 54
- Issue
- 7
- Pages
- 1849-1870
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2065319605
- Cited by
- 592
- References
- 30
- FWCI
- 23.32
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.