Small animal fluorescence and bioluminescence tomography: a review of approaches, algorithms and technology update
The DOI matches its Crossref record; 97 of the 97 references it cites were found in a registry or an index.
Abstract
Emerging fluorescence and bioluminescence tomography approaches have several common, yet several distinct features from established emission tomographies of PET and SPECT. Although both nuclear and optical imaging modalities involve counting of photons, nuclear imaging techniques collect the emitted high energy (100-511 keV) photons after radioactive decay of radionuclides while optical techniques count low-energy (1.5-4.1 eV) photons that are scattered and absorbed by tissues requiring models of light transport for quantitative image reconstruction. Fluorescence imaging has been recently translated into clinic demonstrating high sensitivity, modest tissue penetration depth, and fast, millisecond image acquisition times. As a consequence, the promise of quantitative optical tomography as a complement of small animal PET and SPECT remains high. In this review, we summarize the different instrumentation, methodological approaches and schema for inverse image reconstructions for optical tomography, including luminescence and fluorescence modalities, and comment on limitations and key technological advances needed for further discovery research and translation.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Donoho, D. L. (2006) · IEEE Transactions on Information Theory · doi:10.1109/tit.2006.871582 · Cited by 23,994
Donoho, D. L. (2004) · Cited by 16,591
Wave Propagation and Scattering in Random Media
(1978) · Elsevier eBooks · doi:10.1016/c2013-0-10906-3 · Cited by 4,709
Optical properties of biological tissues: A review
Jacques, S. L. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/11/r37 · Cited by 4,008
The restricted isometry property and its implications for compressed sensing
Candès, E. J. (2008) · Comptes Rendus. Mathématique · doi:10.1016/j.crma.2008.03.014 · Cited by 3,686 · cited 1×
“…regularization is developed to improve the performance of L1 regularization (Gao and Zhao 2010b): RTV(XD) = λ ∫ |∇XD| dr. (50) Theoretically, the exact solution can be recovered when the matrix relevant to the underdetermined system satisfies the restricted isometry property (RIP) (Candes 2008).”
BackgroundTemplates for the Solution of Linear Systems: Building Blocks for Iterative Methods
Barrett, R., Berry, M., Chan, T. F., Demmel, J., Donato, J., Dongarra, J., Eijkhout, V., Pozo, R., Romine, C., & van der Vorst, H. (1994) · Society for Industrial and Applied Mathematics eBooks · doi:10.1137/1.9781611971538 · Cited by 3,479
Optical tomography in medical imaging
Arridge, S. R. (1999) · Inverse Problems · doi:10.1088/0266-5611/15/2/022 · Cited by 2,524 · cited 5×
“…that although fluorescence optical tomography is an emerging imaging modality, optical tomography has been around for more than two decades (Arridge 1999) and developed from DOT, which seeks to reconstruct interior maps of endogenous scattering and absorption properties using…”
BackgroundMethodInfluentialWave Propagation and Scattering in Random Media
(1978) · Elsevier eBooks · doi:10.1016/b978-0-12-374701-3.x5001-7 · Cited by 2,447
Computational Methods of Neutron Transport
Lewis, E. E., & Miller, W. F. (1993) · Medical Entomology and Zoology · Cited by 1,565
Optical-Thermal Response of Laser-Irradiated Tissue
(2011) · Springer eBooks · doi:10.1007/978-90-481-8831-4 · Cited by 1,424
QUANTITATIVE OPTICAL SPECTROSCOPY FOR TISSUE DIAGNOSIS
Richards-Kortum, R., & Sevick-Muraca, E. (1996) · Annual Review of Physical Chemistry · doi:10.1146/annurev.physchem.47.1.555 · Cited by 1,172 · cited 2×
“The noise floor of fluorescence measurements results from this external source and arises due to two following phenomena: (1) autofluorescence (Richards-Kortum and Sevick-Muraca 1996) and (2) incomplete rejection of backscattered excitation light (Sevick-Muraca and Rasmussen 2008).”
BackgroundInfluentialSelf-citationRecent advances in diffuse optical imaging
Gibson, A. P., Hebden, J. C., & Arridge, S. R. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/4/r01 · Cited by 1,114 · cited 1×
“Several review papers and book chapters have comprehensively reviewed the mathematical models for image reconstruction from multiply scattered light (Arridge 1999, Gibson et al 2005, Arridge and Schotland 2009, Jacques 2011).”
BackgroundNtziachristos, V., Bremer, C., & Weissleder, R. (2003) · European Radiology · doi:10.1007/s00330-002-1524-x · Cited by 982 · cited 1×
“Transmission geometries may be better suited for tomographic imaging of targets located deep within the tissue (Ntziachristos et al 2003) and are less susceptible to excitation light leakage than reflectance measurements.”
BackgroundAdvances in In Vivo Bioluminescence Imaging of Gene Expression
Contag, C. H., & Bachmann, M. H. (2002) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.4.111901.093336 · Cited by 870 · cited 2×
“…depends upon the presence of the protein luciferase as a gene reporter to enzymatically catalyze the oxidation of exogenously administered luciferin to produce a single luminescence event of low-energy emission photons (480–560 nm, 2.2–2.5 eV) (Contag and Bachmann 2002) (figure 1(b)).”
BackgroundInfluentialComputational methods of neutron transport
Williams, M. M. R. (1985) · Annals of Nuclear Energy · doi:10.1016/0306-4549(85)90125-2 · Cited by 839
Schaafsma, B. E., Mieog, J. S. D., Hutteman, M., van der Vorst, J. R., Kuppen, P. J. K., Löwik, C. W. G. M., Frangioni, J. V., van de Velde, C. J. H., & Vahrmeijer, A. L. (2011) · Journal of Surgical Oncology · doi:10.1002/jso.21943 · Cited by 816 · cited 1×
“Although not the subject of this review, planar NIR fluorescence imaging has been recently translated into the clinic for non-invasive as well as intraoperative imaging (Marshall et al 2010, Schaafsma et al 2011, Polom et al 2011, Sevick-Muraca 2012).”
BackgroundVo-Dinh, T., & Masters, B. R. (2004) · Journal of Biomedical Optics · doi:10.1117/1.1776177 · Cited by 761
Erlandsson, K., Buvat, I., Pretorius, P. H., Thomas, B. A., & Hutton, B. F. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/r119 · Cited by 733
Dehghani, H., Eames, M. E., Yalavarthy, P. K., Davis, S. C., Srinivasan, S., Carpenter, C. M., Pogue, B. W., & Paulsen, K. D. (2009) · Communications in Numerical Methods in Engineering · doi:10.1002/cnm.1162 · Cited by 728 · cited 2×
“Classic Levenberg– Marquardt algorithm is usually used to solve the adjoint method (equation (39)) (Dehghani et al 2008).”
BackgroundMethodBright and stable near-infrared fluorescent protein for in vivo imaging
Filonov, G. S., Piatkevich, K. D., Ting, L.-M., Zhang, J., Kim, K., & Verkhusha, V. V. (2011) · Nature Biotechnology · doi:10.1038/nbt.1918 · Cited by 688
Mammalian Expression of Infrared Fluorescent Proteins Engineered from a Bacterial Phytochrome
Shu, X., Royant, A., Lin, M. Z., Aguilera, T. A., Lev-Ram, V., Steinbach, P. A., & Tsien, R. Y. (2009) · Science · doi:10.1126/science.1168683 · Cited by 675 · cited 1×
“4 (Filonov et al 2011, Shu et al 2009) have been reported in the literature, there is still significant autofluorescence background that arises from far-red 690 nm excitation (figure 2) (Adams et al 2007).”
BackgroundOptical tomography: forward and inverse problems
Arridge, S. R., & Schotland, J. C. (2009) · Inverse Problems · doi:10.1088/0266-5611/25/12/123010 · Cited by 625 · cited 4×
“…make use of the reconstruction algorithms to quantitatively recover the distribution of fluorescent (Sm(r, ŝ, t or ω)) or bioluminescent (S(r, ŝ)) sources from the surface measurements (J+,m(r, t or ω) or J+(r)) made using the measurement approaches described above (Arridge and Schotland 2009).”
BackgroundMethodInfluentialPre-clinical whole-body fluorescence imaging: Review of instruments, methods and applications
Leblond, F., Davis, S. C., Valdés, P. A., & Pogue, B. W. (2010) · Journal of Photochemistry and Photobiology B: Biology · doi:10.1016/j.jphotobiol.2009.11.007 · Cited by 593 · cited 1×
“59 (2014) R1 Topical Review see Leblond et al 2010) and an even larger number of prototypes have been developed in academic laboratories.”
BackgroundWiscombe, W. J. (1977) · Journal of the Atmospheric Sciences · doi:10.1175/1520-0469(1977)034<1408:tdmrya>2.0.co;2 · Cited by 503 · cited 2×
“The Delta-M (δ-M) phase function is developed by combining the Delta function for strong forward scattering with the HG function (Wiscombe 1977) pδ−M(cos θ ) = 1 2π f δ(1 − cos θ ) + (1 − f ) 2M−1∑ l=0 l∑ m=−l alY ∗ l,m(ŝ ′)Yl,m(ŝ), (21) where al = gl− f1− f .”
MethodNtziachristos, V., & Weissleder, R. (2001) · Optics Letters · doi:10.1364/ol.26.000893 · Cited by 475 · cited 1×
“In fluorescence tomography, linear approximation approaches are usually solved by algebraic reconstruction technique (ART) or its variants (Ntziachristos and Weissleder 2001, Intes et al 2002), which have been extensively used in CT reconstruction.”
MethodTroy, T., Jekic-McMullen, D., Sambucetti, L., & Rice, B. (2004) · Molecular Imaging · doi:10.1162/153535004773861688 · Cited by 418 · cited 1×
“Autofluorescence from red excitation can be mitigated through chlorophyll-free animal chow (Troy et al 2004); however, autofluorescence still represents a significant noise floor that can prevent preclinical fluorescence molecular imaging studies.”
BackgroundA submillimeter resolution fluorescence molecular imaging system for small animal imaging
Graves, E. E., Ripoll, J., Weissleder, R., & Ntziachristos, V. (2003) · Medical Physics · doi:10.1118/1.1568977 · Cited by 390
Adjoint Equations and Analysis of Complex Systems
Marchuk, G. I. (1995) · Springer eBooks · doi:10.1007/978-94-017-0621-6 · Cited by 364
Sevick, E. M., Chance, B., Leigh, J., Nioka, S., & Maris, M. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90339-u · Cited by 360 · cited 1×
“…is based on the fact that the Fourier transform of the distribution of ‘time-of-flights’ measured in TD gives a power spectrum from which the amplitude modulation and phase-delay relative to an incident wave of unit amplitude at modulation frequency ω can be directly determined (Sevick et al 1991).”
BackgroundNear-Infrared Fluorescence Imaging in Humans with Indocyanine Green: A Review and Update
Marshall, M. V., Rasmussen, J. C., Tan, I.-C., Aldrich, M. B., Adams, K. E., Wang, X., Fife, C. E., Maus, E. A., Smith, L. A., & Sevick-Muraca, E. M. (2010) · The Open Surgical Oncology Journal · doi:10.2174/1876504101002010012 · Cited by 341 · cited 1×
“Although not the subject of this review, planar NIR fluorescence imaging has been recently translated into the clinic for non-invasive as well as intraoperative imaging (Marshall et al 2010, Schaafsma et al 2011, Polom et al 2011, Sevick-Muraca 2012).”
Self-citationTranslation of Near-Infrared Fluorescence Imaging Technologies: Emerging Clinical Applications
Sevick-Muraca, E. M. (2012) · Annual Review of Medicine · doi:10.1146/annurev-med-070910-083323 · Cited by 339 · cited 1×
“Although not the subject of this review, planar NIR fluorescence imaging has been recently translated into the clinic for non-invasive as well as intraoperative imaging (Marshall et al 2010, Schaafsma et al 2011, Polom et al 2011, Sevick-Muraca 2012).”
BackgroundSelf-citationLebedev, V. I. (1976) · USSR Computational Mathematics and Mathematical Physics · doi:10.1016/0041-5553(76)90100-2 · Cited by 335
Fluorescence-enhanced, near infrared diagnostic imaging with contrast agents
Sevick-Muraca, E. M., Houston, J. P., & Gurfinkel, M. (2002) · Current Opinion in Chemical Biology · doi:10.1016/s1367-5931(02)00356-3 · Cited by 328 · cited 1×
“Hence as the ‘time-of-flight’ of photon travel can aid image reconstruction in PET, time-dependent measurements of photon travel can likewise aid in fluorescence tomography (Sevick-Muraca et al 2002).”
BackgroundSelf-citationFluorescence lifetime imaging in turbid media
O'Leary, M. A., Boas, D. A., Li, X. D., Chance, B., & Yodh, A. G. (1996) · Optics Letters · doi:10.1364/ol.21.000158 · Cited by 293
Ale, A., Ermolayev, V., Herzog, E., Cohrs, C., de Angelis, M. H., & Ntziachristos, V. (2012) · Nature Methods · doi:10.1038/nmeth.2014 · Cited by 276 · cited 1×
“…Contrast agent Imaging system (CW/TD/FD) and transmission/ reflectance/ circular modes Multimodal imaging Reconstruction techniques: forward and inverse approach, index matching fluid, acquisition times Ale et al (2012) Free-space scanned excitation lasers (2) and non-contact cooled CCD detection.”
BackgroundHyperspectral and multispectral bioluminescence optical tomography for small animal imaging
Chaudhari, A. J., Darvas, F., Bading, J. R., Moats, R. A., Conti, P. S., Smith, D. J., Cherry, S. R., & Leahy, R. M. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/23/001 · Cited by 273 · cited 1×
“…phantom: 4.4 MBq mouse: 11.1 MBq CW CLT/CT SP3 approximation to RTE with reconstruction using SVD CCD integration 1 min (phantom), 3 min (mouse) Chaudhari et al (2005) Four image projections using non-contact back-illuminated CCD detection with IVIS 200 imaging system with four mirrors (a)…”
MethodInfluentialLight transport in biological tissue based on the simplified spherical harmonics equations
Klose, A. D., & Larsen, E. W. (2006) · Journal of Computational Physics · doi:10.1016/j.jcp.2006.07.007 · Cited by 268
Marshall, M. V., Rasmussen, J. C., Tan, I.-C., Aldrich, M. B., Adams, K. E., Wang, X., Fife, C. E., Maus, E. A., Smith, L. A., & Sevick-Muraca, E. M. (2010) · The Open Surgical Oncology Journal · doi:10.2174/1876504101002020012 · Cited by 260
Self-citationPolom, K., Murawa, D., Rho, Y., Nowaczyk, P., Hünerbein, M., & Murawa, P. (2011) · Cancer · doi:10.1002/cncr.26087 · Cited by 251 · cited 1×
“Although not the subject of this review, planar NIR fluorescence imaging has been recently translated into the clinic for non-invasive as well as intraoperative imaging (Marshall et al 2010, Schaafsma et al 2011, Polom et al 2011, Sevick-Muraca 2012).”
BackgroundSPECT detectors: the Anger Camera and beyond
Peterson, T. E., & Furenlid, L. R. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/17/r01 · Cited by 217
Lebedev, V. I. (1975) · USSR Computational Mathematics and Mathematical Physics · doi:10.1016/0041-5553(75)90133-0 · Cited by 197 · cited 1×
“LMN and LCN quadratures based on the Markov and Chebyshev types, are developed by integrating the spherical harmonics functions on the unit sphere (Lebedev 1975, 1976).”
MethodThree-dimensional reconstruction of in vivo bioluminescent sources based on multispectral imaging
Kuo, C., Coquoz, O., Troy, T. L., Xu, H., & Rice, B. W. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2717898 · Cited by 195 · cited 2×
“Instead of using multiple projections as conducted with fluorescence and Cerenkov imaging, the approach uses surface CW measurements conducted at multiple wavelengths to reconstruct the source of luminescent photons (Kuo et al 2007).”
MethodThe TN Quadrature Set for the Discrete Ordinates Method
Thurgood, C. P., Pollard, A., & Becker, H. A. (1995) · ASME Journal of Heat and Mass Transfer · doi:10.1115/1.2836285 · Cited by 174 · cited 1×
“Using the FEM, piecewise constant (TN quadratures) and quasilinear angular (PQLAN quadratures) methods are developed (El Wakil and Sacadura 1992, Thurgood et al 1995).”
MethodExperimental Fluorescence Tomography of Tissues With Noncontact Measurements
Schulz, R. B., Ripoll, J., & Ntziachristos, V. (2004) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.825633 · Cited by 174 · cited 3×
“…Lin et al 2010, Cao and Peter 2010) and in small animals (Graves et al 2003, Deliolanis et al 2007, Garofalakis et al 2007, Bourayou et al 2008, Schulz et al 2004, 2010, Patwardhan et al 2005, Zacharakis et al 2005, Meyer et al 2007, Herve et al 2007, Koenig et al 2010, Davis et al 2008, Da…”
BackgroundMethodMagnetic resonance–coupled fluorescence tomography scanner for molecular imaging of tissue
Davis, S. C., Pogue, B. W., Springett, R., Leussler, C., Mazurkewitz, P., Tuttle, S. B., Gibbs-Strauss, S. L., Jiang, S. S., Dehghani, H., & Paulsen, K. D. (2008) · Review of Scientific Instruments · doi:10.1063/1.2919131 · Cited by 171
Brooksby, B. A., Jiang, S., Dehghani, H., Pogue, B. W., Paulsen, K. D., Weaver, J. B., Kogel, C. A., & Poplack, S. P. (2005) · Journal of Biomedical Optics · doi:10.1117/1.2098627 · Cited by 171 · cited 2×
“Using phantoms, Cao and Peter (2010) utilized SPECT priors for suppressing reconstruction-related artifacts and for achieving”
MethodA multilevel adaptive finite element algorithm for bioluminescence tomography
Lv, Y., Tian, J., Cong, W., Wang, G., Luo, J., Yang, W., & Li, H. (2006) · Optics Express · doi:10.1364/oe.14.008211 · Cited by 170 · cited 1×
“…add a priori information of the unknown source variable such as physical constraints (Cong et al 2004), permissible source region (Cong et al 2005, Lv et al 2006) and multispectral information (Cong and Wang 2006, Lv et al 2007) into B in order to improve the tomographical quality of emission…”
BackgroundTime-dependent whole-body fluorescence tomography of probe bio-distributions in mice
Patwardhan, S. V., Bloch, S. R., Achilefu, S., & Culver, J. P. (2005) · Optics Express · doi:10.1364/opex.13.002564 · Cited by 168 · cited 3×
“…reflectance/ circular modes Multimodal imaging Reconstruction techniques: forward and inverse approach, index matching fluid, acquisition times Patwardhan et al (2005) Free-space scanned excitation beam; non-contact, cooled, lens-coupled EMCCD detection (a) Dye-filled tubes (∅3 mm) suspended…”
BackgroundMethodInfluentialIn vivo Cerenkov luminescence imaging: a new tool for molecular imaging
Mitchell, G. S., Gill, R. K., Boucher, D. L., Li, C., & Cherry, S. R. (2011) · Philosophical Transactions of the Royal Society A: Mathematical, Physical and Engineering Sciences · doi:10.1098/rsta.2011.0271 · Cited by 164 · cited 1×
“It is noteworthy that low-energy luminescent Cerenkov photons are also generated as the charged positron particle, traveling faster than the speed of light, interacts with the medium (Mitchell et al 2011).”
BackgroundGurfinkel, M., Thompson, A. B., Ralston, W., Troy, T. L., Moore, A. L., Moore, T. A., Gust, J. D., Tatman, D., Reynolds, J. S., Muggenburg, B., et al. (2007) · Photochemistry and Photobiology · doi:10.1562/0031-8655(2000)0720094poiahc2.0.co2 · Cited by 164
Self-citationHybrid System for Simultaneous Fluorescence and X-Ray Computed Tomography
Schulz, R. B., Ale, A. B. F., Sarantopoulos, A., Freyer, M., Soehngen, E., Zientkowska, M., & Ntziachristos, V. (2009) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2009.2035310 · Cited by 157 · cited 2×
“…Lin et al 2010, Cao and Peter 2010) and in small animals (Graves et al 2003, Deliolanis et al 2007, Garofalakis et al 2007, Bourayou et al 2008, Schulz et al 2004, 2010, Patwardhan et al 2005, Zacharakis et al 2005, Meyer et al 2007, Herve et al 2007, Koenig et al 2010, Davis et al 2008, Da…”
BackgroundYalavarthy, P. K., Pogue, B. W., Dehghani, H., & Paulsen, K. D. (2007) · Medical Physics · doi:10.1118/1.2733803 · Cited by 156 · cited 1×
“When Helmholtz-type anatomical information (Yalavarthy et al 2007) is used, Li j becomes Li j = ⎧⎪⎪⎨ ⎪⎪⎩ 0 if i and j are not in the same region − 1 N + (kh)2 if i and j are in the same region 1 if i = j, (48) where k is the wave number in the Helmholtz equation and is usually selected to be the…”
MethodNtziachristos, V., & Weissleder, R. (2002) · Medical Physics · doi:10.1118/1.1470209 · Cited by 153 · cited 2×
“The CCD alone is too slow for time-dependent measurements but has been utilized for CW-based image reconstruction in phantoms (Ntziachristos and Weissleder 2002, Tan and Jiang 2008, Barber et al 2010, Lin et al 2010, Cao and Peter 2010) and in small animals (Graves et al 2003, Deliolanis et al…”
MethodFluorescence-enhanced optical imaging in large tissue volumes using a gain-modulated ICCD camera
Godavarty, A., Eppstein, M. J., Zhang, C., Theru, S., Thompson, A. B., Gurfinkel, M., & Sevick-Muraca, E. M. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/12/303 · Cited by 144 · cited 16×
“In contrast to CCDs which read out arrays of accumulated charge on pixels, CMOS sensors enable individual readout of pixels, potentially enabling enhanced capabilities.”
BackgroundMethodInfluentialSelf-citationJointL1and total variation regularization for fluorescence molecular tomography
Dutta, J., Ahn, S., Li, C., Cherry, S. R., & Leahy, R. M. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/6/1459 · Cited by 139 · cited 1×
“Different regularization methods and parameters can result in different reconstruction results (Gao and Zhao 2010a, Dutta et al 2012).”
ResultA Time Domain Fluorescence Tomography System for Small Animal Imaging
Kumar, A. T. N., Raymond, S. B., Dunn, A. K., Bacskai, B. J., & Boas, D. A. (2008) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2008.918341 · Cited by 139 · cited 4×
“…Recent advancements in the tomographic algorithms, and surface rendering techniques offered by profilometry (Koenig et al 2010, Zhang et al 2009, Kumar et al 2008) and hybrid imaging (Kepshire et al 2009, Darne et al 2012) have enabled developments to evolve from the practice of confining and…”
BackgroundMethodInfluentialNoise performance comparison of ICCD with CCD and EMCCD cameras
Dussault, D., & Hoess, P. (2004) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.561839 · Cited by 126 · cited 2×
“Therefore, the SNR of the CCD camera can be given by (Dussault and Hoess 2004) SNRCCD = Gη pτ( N2st + N2dc + N2rd )1/2 , (32) where G is a multiplication gain (G = 1 when the CCD is employed); η is the quantum efficiency (QE); p denotes the incident photon flux; and τ is the integration time for…”
MethodA finite-element-based reconstruction method for 3D fluorescence tomography
Cong, A. X., & Wang, G. (2005) · Optics Express · doi:10.1364/opex.13.009847 · Cited by 125 · cited 1×
“As a result, similar linear reconstruction strategies can be readily developed for fluorescence tomography (Cong and Wang 2005, Lu et al 2011b).”
BackgroundThree‐dimensional fluorescence lifetime tomography
Godavarty, A., Sevick-Muraca, E. M., & Eppstein, M. J. (2005) · Medical Physics · doi:10.1118/1.1861160 · Cited by 124 · cited 17×
“In contrast to CCDs which read out arrays of accumulated charge on pixels, CMOS sensors enable individual readout of pixels, potentially enabling enhanced capabilities.”
BackgroundMethodInfluentialSelf-citationLu, Y., Zhang, X., Douraghy, A., Stout, D., Tian, J., Chan, T. F.-C., & Chatziioannou, A. F. (2009) · Optics Express · doi:10.1364/oe.17.008062 · Cited by 112 · cited 30×
“Although the HG phase function is the most accurate among the existing phase functions, it becomes difficult to realize efficient computation or the acquisition of the RTE approximations.”
MethodInfluentialSelf-citationMultilevel bioluminescence tomography based on radiative transfer equation Part 1: l1 regularization
Gao, H., & Zhao, H. (2010) · Optics Express · doi:10.1364/oe.18.001854 · Cited by 112 · cited 3×
“Total variation (TV) regularization is developed to improve the performance of L1 regularization (Gao and Zhao 2010b): RTV(XD) = λ ∫ |∇XD| dr. (50) Theoretically, the exact solution can be recovered when the matrix relevant to the underdetermined system satisfies the restricted isometry property…”
BackgroundMethodResultSevick-Muraca, E. M., & Rasmussen, J. C. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2953185 · Cited by 110 · cited 1×
“The noise floor of fluorescence measurements results from this external source and arises due to two following phenomena: (1) autofluorescence (Richards-Kortum and Sevick-Muraca 1996) and (2) incomplete rejection of backscattered excitation light (Sevick-Muraca and Rasmussen 2008).”
BackgroundInfluentialSelf-citationProjection access order in algebraic reconstruction technique for diffuse optical tomography
Intes, X., Ntziachristos, V., Culver, J. P., Yodh, A. G., & Chance, B. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/1/401 · Cited by 108 · cited 1×
“In fluorescence tomography, linear approximation approaches are usually solved by algebraic reconstruction technique (ART) or its variants (Ntziachristos and Weissleder 2001, Intes et al 2002), which have been extensively used in CT reconstruction.”
MethodFluorescent protein tomography scanner for small animal imaging
Zacharakis, G., Ripoll, J., Weissleder, R., & Ntziachristos, V. (2005) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2004.843254 · Cited by 104 · cited 3×
“…animals (Graves et al 2003, Deliolanis et al 2007, Garofalakis et al 2007, Bourayou et al 2008, Schulz et al 2004, 2010, Patwardhan et al 2005, Zacharakis et al 2005, Meyer et al 2007, Herve et al 2007, Koenig et al 2010, Davis et al 2008, Da Silva et al 2008, Li et al 2009, 2010, Yang et al…”
BackgroundInfluentialA microcomputed tomography guided fluorescence tomography system for small animal molecular imaging
Kepshire, D., Mincu, N. E., Hutchins, M., Gruber, J. D., Dehghani, H., Hypnarowski, J., Leblond, F., Khayat, M., & Pogue, B. W. (2009) · Review of Scientific Instruments · doi:10.1063/1.3109903 · Cited by 97
Li, C., Mitchell, G. S., Dutta, J., Ahn, S., Leahy, R. M., & Cherry, S. R. (2009) · Optics Express · doi:10.1364/oe.17.007571 · Cited by 94 · cited 2×
“…Bourayou et al 2008, Schulz et al 2004, 2010, Patwardhan et al 2005, Zacharakis et al 2005, Meyer et al 2007, Herve et al 2007, Koenig et al 2010, Davis et al 2008, Da Silva et al 2008, Li et al 2009, 2010, Yang et al 2010, Guo et al 2010, Liu et al 2011, Hu et al 2010, 2012, Zhong et al 2011b).”
MethodNoncontact fluorescence diffuse optical tomography of heterogeneous media
Hervé, L., Koenig, A., Silva, A. D., Berger, M., Boutet, J., Dinten, J., Peltié, P., & Rizo, P. (2007) · Applied Optics · doi:10.1364/ao.46.004896 · Cited by 83
Klose, A. D., Beattie, B. J., Dehghani, H., Vider, J., Le, C. H., Ponomarev, V., & Blasberg, R. G. (2009) · Medical Physics · doi:10.1118/1.3273034 · Cited by 83
Noncontact optical imaging in mice with full angular coverage and automatic surface extraction
Meyer, H., Garofalakis, A., Zacharakis, G., Psycharakis, S. E., Mamalaki, C., Kioussis, D., Economou, E. N., Ntziachristos, V., & Ripoll, J. (2007) · Applied Optics · doi:10.1364/ao.46.003617 · Cited by 80
Kim, H. K., & Hielscher, A. H. (2008) · Inverse Problems · doi:10.1088/0266-5611/25/1/015010 · Cited by 78
Discrete ordinates quadrature schemes for multidimensional radiative transfer
Koch, R., Krebs, W., Wittig, S. L. K., & Viskanta, R. (1995) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/0022-4073(95)90012-8 · Cited by 77 · cited 1×
“A general construction principle called double cyclic triangles (DCT quadratures) is developed using the SN methods (Koch et al 1995).”
MethodA Combined Fluorescence and Microcomputed Tomography System for Small Animal Imaging
Guo, X., Liu, X., Wang, X., Tian, F., Liu, F., Zhang, B., Hu, G., & Bai, J. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2073468 · Cited by 77 · cited 4×
“…transmission/ reflectance/ circular modes Multimodal imaging Reconstruction techniques: forward and inverse approach, index matching fluid, acquisition times Guo et al (2010) ∗ , Liu et al (2011)† Free-space tungsten halogen (300–2500 nm) source; non-contact, lens-coupled, cooled EMCCD detection.”
BackgroundMethodResultInfluentialStuker, F., Baltes, C., Dikaiou, K., et al. (2011) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2011.2112669 · Cited by 76 · cited 1×
“…reflectance/ circular modes Multimodal imaging Reconstruction techniques: forward and inverse approach, index matching fluid, acquisition times Stuker et al (2011) Free-space scanned excitation source; non-contact detection using 32 × 32 array of lens-coupled singlephoton avalanche diodes…”
MethodSynthesis of a DOTA−Biotin Conjugate for Radionuclide Chelation via Cu-Free Click Chemistry
Schultz, M. K., Parameswarappa, S. G., & Pigge, F. C. (2010) · Organic Letters · doi:10.1021/ol100774p · Cited by 76 · cited 1×
“Schultz et al (2010), have shown that in vivo fluorescence reconstruction can be improved upon incorporating segmented CT images as a priori information for use in reconstruction algorithms.”
BackgroundDetector concept for OPET-a combined PET and optical imaging system
Prout, D. L., Silverman, R. W., & Chatziioannou, A. F. (2004) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2004.829736 · Cited by 63 · cited 1×
“Area detectors comprised of multi-anode PMTs are used in optical-PET (OPET) R37 (which couples bioluminescence and PET tomography) and are coupled with gadolinium silicate crystal arrays for simultaneous PET annihilation and bioluminescent photon detection (Prout et al 2004).”
MethodGarofalakis, A., Zacharakis, G., Meyer, H., Economou, E. N., Mamalaki, C., Papamatheakis, J. D., Kioussis, D., Ntziachristos, V., & Ripoll, J. (2007) · Molecular Imaging · doi:10.2310/7290.2007.00007 · Cited by 60 · cited 4×
“…2002, Tan and Jiang 2008, Barber et al 2010, Lin et al 2010, Cao and Peter 2010) and in small animals (Graves et al 2003, Deliolanis et al 2007, Garofalakis et al 2007, Bourayou et al 2008, Schulz et al 2004, 2010, Patwardhan et al 2005, Zacharakis et al 2005, Meyer et al 2007, Herve et al…”
BackgroundMethodInfluentialCerenkov Luminescence Tomography forIn VivoRadiopharmaceutical Imaging
Zhong, J., Qin, C., Yang, X., Zhu, S., Zhang, X., & Tian, J. (2011) · International Journal of Biomedical Imaging · doi:10.1155/2011/641618 · Cited by 51 · cited 2×
“…collection configuration Phantom/animal model Contrast agent Imaging system (CW/TD/FD) Multimodal imaging Reconstruction techniques: forward and inverse approach, acquisition times Zhong et al (2011a, 2011b) Non-contact, cooled CCD detection with vertically rotated animal (four projections).”
MethodYang, X., Gong, H., Quan, G., Deng, Y., & Luo, Q. (2010) · Review of Scientific Instruments · doi:10.1063/1.3422252 · Cited by 49 · cited 3×
“…the focused beam of excitation light is typically scanned across the tissue surface using galvanometer-based dual-mirrors (Patwardhan et al 2005) or motor-controlled linear translation stages (Yang et al 2010) that can precisely position the excitation light with good accuracy and repeatability.”
BackgroundHu, Z., Ma, X., Qu, X., et al. (2012) · PLoS ONE · doi:10.1371/journal.pone.0037623 · Cited by 47 · cited 2×
“Preconditioned conjugate gradient method for reconstruction CCD integration time 5 min (phantom), 15 min (mouse) Hu et al (2010, 2012) Optical imaging with IVIS Kinetic system.”
MethodA Novel Sparsity Reconstruction Method from Poisson Data for 3D Bioluminescence Tomography
Zhang, X., Lu, Y., & Chan, T. F.-C. (2011) · Journal of Scientific Computing · doi:10.1007/s10915-011-9533-z · Cited by 45 · cited 2×
“…it is a non-deterministic polynomial problem to solve L0 regularization-based reconstructions; some researchers have sought to improve the computational efficiency and reconstruction quality by using Lp (0 < p < 1) regularization methods (Okawa et al 2011, Zhang et al 2012a, Zhong et al 2012).”
MethodResultSelf-citationSimultaneous PET and Multispectral 3-Dimensional Fluorescence Optical Tomography Imaging System
Li, C., Yang, Y., Mitchell, G. S., & Cherry, S. R. (2011) · Journal of Nuclear Medicine · doi:10.2967/jnumed.110.082859 · Cited by 45 · cited 3×
“CT-derived structural priors Li et al (2011) CW system using conical mirror placed within microPET to reflect fluorescence signals on EMCCD placed external to gantry.”
BackgroundMethodInfluentialGe, J., Zhu, B., Regalado, S., & Godavarty, A. (2008) · Medical Physics · doi:10.1118/1.2940603 · Cited by 43
Comparison of noncontact and fiber-based fluorescence-mediated tomography
Schulz, R. B., Peter, J., Semmler, W., D’Andrea, C., Valentini, G., & Cubeddu, R. (2006) · Optics Letters · doi:10.1364/ol.31.000769 · Cited by 40 · cited 1×
“A study by (Schulz et al 2006) concluded that non-contact imaging significantly improves the tomographic imaging quality compared to contact imaging using identical numbers of excitation illumination and fluorescence collection sites, although the performance may be more likely to be a result of…”
BackgroundLiu, K., Tian, J., Lu, Y., Qin, C., Yang, X., Zhu, S., & Zhang, X. (2010) · Optics Express · doi:10.1364/oe.18.003732 · Cited by 34 · cited 1×
“…methods such as the modified Newton method and the limited memory variable metric algorithm (BLMVM) (Cong et al 2005, Lu et al 2009a), the generalized graph cut strategy (Liu et al 2010) and differential evolution approach (Cong et al 2010) are also further developed for linear reconstruction.”
MethodSelf-citationDifferential Evolution Approach for Regularized Bioluminescence Tomography
Cong, A. X., Cong, W., Lu, Y., Santago, P., Chatziioannou, A. F., & Wang, G. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2010.2041452 · Cited by 32 · cited 1×
“…methods such as the modified Newton method and the limited memory variable metric algorithm (BLMVM) (Cong et al 2005, Lu et al 2009a), the generalized graph cut strategy (Liu et al 2010) and differential evolution approach (Cong et al 2010) are also further developed for linear reconstruction.”
MethodSelf-citationIn Vivo Mouse Bioluminescence Tomography with Radionuclide-Based Imaging Validation
Lu, Y., Machado, H. B., Bao, Q., Stout, D., Herschman, H., & Chatziioannou, A. F. (2010) · Molecular Imaging and Biology · doi:10.1007/s11307-010-0332-y · Cited by 30 · cited 5×
“…model Contrast agent Imaging system (CW/TD/FD) Multimodal imaging Reconstruction techniques: forward and inverse approach, acquisition times Lu et al (2011a) Single projection, non-contact CCD detection using Maestro 2 imaging system Mouse model with xenograft tumor Firefly luciferase CW…”
BackgroundMethodInfluentialSelf-citationTurchin, I. V., Kamensky, V. A., Plekhanov, V. I., Orlova, A., Kleshnin, M. S., Fiks, I. I., Shirmanova, M. V., Meerovich, I. G., Arslanbaeva, L. R., Jerdeva, V. V., et al. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2953528 · Cited by 29 · cited 3×
“…∗†‡/ PET‡/CT‡ DA and FDM for forward approach; normalized heterogeneity reconstruction using Rytov expansion for inverse approach. with ∗ and without ∗†‡ the use of index matching fluid Turchin et al (2008) Simultaneous modulated scanning (1 kHz) of free-space excitation beam and non-contact,…”
BackgroundMethodInfluentialCombined Fluorescence and X-Ray Tomography for Quantitative In Vivo Detection of Fluorophore
Barber, W. C., Lin, Y.-T., Nalcioglu, O., Iwanczyk, J. S., Hartsough, N. E., & Gülşen, G. (2010) · Technology in Cancer Research & Treatment · doi:10.1177/153303461000900105 · Cited by 28 · cited 4×
“…measurements but has been utilized for CW-based image reconstruction in phantoms (Ntziachristos and Weissleder 2002, Tan and Jiang 2008, Barber et al 2010, Lin et al 2010, Cao and Peter 2010) and in small animals (Graves et al 2003, Deliolanis et al 2007, Garofalakis et al 2007,…”
BackgroundMethodInfluentialNear- Infrared Fluorescence Imaging and Spectroscopy in Random Media and Tissues
Sevick-Muraca, E. M., Kuwana, E., Godavarty, A., Houston, J. P., Thompson, A., & Roy, R. (2003) · CRC Press eBooks · doi:10.1201/9780203008997.ch33 · Cited by 27 · cited 1×
“FD measurements at MHz frequencies must employ the use of homodyne or heterodyne schemas (Sevick-Muraca et al 2003) in which the excitation source and the detector (whether an intensified ICCD or a PMT) are modulated at the same MHz ω (homodyne operation) with varying phase lags, or at ω + ω…”
MethodSelf-citationQuantitative fluorescence imaging of point-like sources in small animals
Comsa, D. C., Farrell, T. J., & Patterson, M. S. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/20/016 · Cited by 25 · cited 1×
“One current goal of optical tomography is the reconstruction of source strength, its absolute position (Comsa et al 2008), and, in the case of fluorescence tomography using timedependent methods, lifetime.”
BackgroundCao, L., & Peter, J. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/9/018 · Cited by 23 · cited 5×
“In this framework, the maximum likelihood-expectation maximization (MLEM) algorithm (Cao and Peter 2010), iterative coordinate descent (ICD) method (Milstein”
MethodInfluentialFluorescence tomography technique optimized for noninvasive imaging of the mouse brain
Bourayou, R., Boeth, H., Benav, H., Betz, T., Lindauer, U., Nierhaus, T., Klohs, J., Wunder, A., Dirnagl, U., & Steinbrink, J. M. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2968262 · Cited by 23 · cited 3×
“Excitation light is delivered in one of two ways: (1) by a fiber optic in contact with the tissue (Schulz et al 2004, Bourayou et al 2008, Davis et al 2008, Lin et al 2011) or a container holding the animal submerged within the index-matched fluid (Graves et al 2003), or (2) as in the majority of…”
BackgroundMethodInfluentialZhang, Q., Chen, X., Qu, X., Liang, J., & Tian, J. (2012) · Biomedical Optics Express · doi:10.1364/boe.3.002916 · Cited by 20 · cited 2×
“…it is a non-deterministic polynomial problem to solve L0 regularization-based reconstructions; some researchers have sought to improve the computational efficiency and reconstruction quality by using Lp (0 < p < 1) regularization methods (Okawa et al 2011, Zhang et al 2012a, Zhong et al 2012).”
MethodResultLiu, S., Zhang, B., Wang, X. Y., Li, L., Chen, Y., Liu, X., Liu, F., Shan, B., & Bai, J. (2010) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2010.2068310 · Cited by 18 · cited 5×
“Studies show that, multi-spectral fluorescence imaging conducted across 360◦ projections as performed in conventional gantry-based CT, nuclear and MR imaging enables better fluorescence image reconstruction than those made with single projections (Garofalakis et al 2007, Liu et al 2011).”
BackgroundMethodResultInfluentialFast-Specific Tomography Imaging via Cerenkov Emission
Zhong, J., Qin, C., Yang, X., Chen, Z., Yang, X., & Tian, J. (2011) · Molecular Imaging and Biology · doi:10.1007/s11307-011-0510-6 · Cited by 17 · cited 1×
“…it is a non-deterministic polynomial problem to solve L0 regularization-based reconstructions; some researchers have sought to improve the computational efficiency and reconstruction quality by using Lp (0 < p < 1) regularization methods (Okawa et al 2011, Zhang et al 2012a, Zhong et al 2012).”
MethodWu, P., Liu, K., Zhang, Q., Xue, Z., Li, Y., Ning, N., Yang, X., Li, X. D., & Tian, J. (2012) · Journal of Biomedical Optics · doi:10.1117/1.jbo.17.12.126012 · Cited by 16 · cited 1×
“A new-emerging compressed sensing (CS) theory (Donoho 2006) that makes use of sparse characteristics of the recovered signal to find the solution from an underdetermined system can be used to improve the quality of image reconstruction (Lu et al 2009b, Gao and Zhao 2010a, Wu et al 2012).”
MethodComsa, D. C., Farrell, T. J., & Patterson, M. S. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/17/021 · Cited by 15 · cited 1×
“…of 20 nm) BLT Analytical DA for sensitivity matrix; weight least-squares problem with adaptive mesh refinement Imaging time 3 min/wavelength (mouse) Comsa et al (2007) Non-contact, cooled CCD detection using single projections assuming point source One nude mouse, four white mice, four rats Diode…”
Cited by
Erlandsson, K., Buvat, I., Pretorius, P. H., Thomas, B. A., & Hutton, B. F. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/21/r119 · Cited by 733
Li, L., Zhu, L., Ma, C., Lin, L., Yao, J., Wang, L., Maslov, K., Zhang, R., Chen, W., Shi, J., et al. (2017) · Nature Biomedical Engineering · doi:10.1038/s41551-017-0071 · Cited by 477
Deep in vivo photoacoustic imaging of mammalian tissues using a tyrosinase-based genetic reporter
Jathoul, A. P., Laufer, J., Ogunlade, O., Treeby, B., Cox, B., Zhang, E., Johnson, P., Pizzey, A. R., Philip, B., Marafioti, T., et al. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.22 · Cited by 442
In Vivo Molecular Bioluminescence Imaging: New Tools and Applications
Mezzanotte, L., van ‘t Root, M., Karatas, H., Goun, E. A., & Löwik, C. W. G. M. (2017) · Trends in Biotechnology · doi:10.1016/j.tibtech.2017.03.012 · Cited by 288
A review of performance of near-infrared fluorescence imaging devices used in clinical studies
Zhu, B., & Sevick-Muraca, E. M. (2015) · The British Journal of Radiology · doi:10.1259/bjr.20140547 · Cited by 175
Self-citation
Metadata
- Authors
- Darne, C., Lu, Y., & Sevick-Muraca, E. M.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2013-12-16
- Volume
- 59
- Issue
- 1
- Pages
- R1-R64
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2043818471
- Cited by
- 199
- References
- 97
- FWCI
- 17.59
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.