An exponential growth of computational phantom research in radiation protection, imaging, and radiotherapy: a review of the fifty-year history
Open accessThe DOI matches its Crossref record; 104 of the 104 references it cites were found in a registry or an index.
Abstract
Radiation dose calculation using models of the human anatomy has been a subject of great interest to radiation protection, medical imaging, and radiotherapy. However, early pioneers of this field did not foresee the exponential growth of research activity as observed today. This review article walks the reader through the history of the research and development in this field of study which started some 50 years ago. This review identifies a clear progression of computational phantom complexity which can be denoted by three distinct generations. The first generation of stylized phantoms, representing a grouping of less than dozen models, was initially developed in the 1960s at Oak Ridge National Laboratory to calculate internal doses from nuclear medicine procedures. Despite their anatomical simplicity, these computational phantoms were the best tools available at the time for internal/external dosimetry, image evaluation, and treatment dose evaluations. A second generation of a large number of voxelized phantoms arose rapidly in the late 1980s as a result of the increased availability of tomographic medical imaging and computers. Surprisingly, the last decade saw the emergence of the third generation of phantoms which are based on advanced geometries called boundary representation (BREP) in the form of Non-Uniform Rational B-Splines (NURBS) or polygonal meshes. This new class of phantoms now consists of over 287 models including those used for non-ionizing radiation applications. This review article aims to provide the reader with a general understanding of how the field of computational phantoms came about and the technical challenges it faced at different times. This goal is achieved by defining basic geometry modeling techniques and by analyzing selected phantoms in terms of geometrical features and dosimetric problems to be solved. The rich historical information is summarized in four tables that are aided by highlights in the text on how some of the most well-known phantoms were developed and used in practice. Some of the information covered in this review has not been previously reported, for example, the CAM and CAF phantoms developed in 1970s for space radiation applications. The author also clarifies confusion about 'population-average' prospective dosimetry needed for radiological protection under the current ICRP radiation protection system and 'individualized' retrospective dosimetry often performed for medical physics studies. To illustrate the impact of computational phantoms, a section of this article is devoted to examples from the author's own research group. Finally the author explains an unexpected finding during the course of preparing for this article that the phantoms from the past 50 years followed a pattern of exponential growth. The review ends on a brief discussion of future research needs (a supplementary file '3DPhantoms.pdf' to figure 15 is available for download that will allow a reader to interactively visualize the phantoms in 3D).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Geant4 developments and applications
Allison, J., Amako, K., Apostolakis, J., Araujo, H., Arce Dubois, P., Asai, M., Barrand, G., Capra, R., Chauvie, S., Chytracek, R., et al. (2006) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2006.869826 · Cited by 6,946
MCNP-A General Monte Carlo N-Particle Transport Code
Briesmeister, J. F. (1993) · Cited by 5,110
Hammersley, J. M., & Handscomb, D. C. (1964) · Springer eBooks · doi:10.1007/978-94-009-5819-7 · Cited by 4,054
Introduction to Radiological Physics and Radiation Dosimetry
Attix, F. H. (1986) · Wiley eBooks · doi:10.1002/9783527617135 · Cited by 1,868
Recommendations of the International Commission on Radiological Protection, ICRP Publication 26
Icrp (1977) · Annals of the ICRP · Cited by 1,780
Report of the task group on reference man
(1979) · Annals of the ICRP · doi:10.1016/0146-6453(79)90123-4 · Cited by 1,706
Photon cross sections from 1 keV to 100 MeV for elements Z=1 to Z=100
Storm, L., & Israel, H. I. (1970) · Atomic Data and Nuclear Data Tables · doi:10.1016/s0092-640x(70)80017-1 · Cited by 1,539
Christ, A., Kainz, W., Hahn, E. G., Honegger, K., Zefferer, M., Neufeld, E., Rascher, W., Janka, R., Bautz, W., Chen, J., et al. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/n01 · Cited by 1,439
The FLUKA code: description and benchmarking
Battistoni, G., Cerutti, F., Fassò, A., Ferrari, A., Muraro, S., Ranft, J., Roesler, S., & Sala, P. R. (2007) · AIP Conference Proceedings · doi:10.1063/1.2720455 · Cited by 1,308
Computerized three‐dimensional segmented human anatomy
Zubal, I. G., Harrell, C. R., Smith, E. O., Rattner, Z., Gindi, G., & Hoffer, P. B. (1994) · Medical Physics · doi:10.1118/1.597290 · Cited by 1,103
Nagaoka, T., Watanabe, S., Sakurai, K., Kunieda, E., Watanabe, S., Taki, M., & Yamanaka, Y. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/1/001 · Cited by 774
Specific absorbed fractions of energy at various ages from internal photon sources: 6, Newborn
Cristy, M., & Eckerman, K. F. (1987) · doi:10.2172/6202949 · Cited by 692
Basic anatomical and physiological data for use in radiological protection : reference values
Valentin, J. (2002) · Medical Entomology and Zoology · Cited by 680
Ws, S., Hl, F., Mr, F., & Warner, G. G. (1969) · PubMed · Cited by 627
Hubbell, J. H. (1969) · doi:10.6028/nbs.nsrds.29 · Cited by 598
Initial MCNP6 Release Overview - MCNP6 version 1.0
Goorley, J. T., USDOE, James, M., Booth, T., Brown, F. B., Bull, J., Cox, L. J., Durkee, J. W., Elson, J. S., Fensin, M., et al. (2013) · OSTI OAI (U.S. Department of Energy Office of Scientific and Technical Information) · doi:10.2172/1086758 · Cited by 569
Nuclear Energy Agency (2015) · PENELOPE: A code system for Monte Carlo simulation of electron and photon transport · doi:10.1787/4e3f14db-en · Cited by 534
Gosselin, M.-C., Neufeld, E., Moser, H., Huber, E., Farcito, S., Gerber, L., Jedensjö, M., Hilber, I., Gennaro, F. D., Lloyd, B., et al. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/5287 · Cited by 520
Realistic reference phantoms: An ICRP/ICRU joint effort
(2009) · Annals of the ICRP · doi:10.1016/j.icrp.2009.09.001 · Cited by 496
Development of a 4-D digital mouse phantom for molecular imaging research
SEGARS, W. (2004) · Molecular Imaging & Biology · doi:10.1016/j.mibio.2004.03.002 · Cited by 420
Xu, X. G., Chao, T. C., & Bozkurt, A. (2000) · Health Physics · doi:10.1097/00004032-200005000-00003 · Cited by 364
Self-citationThe UF family of reference hybrid phantoms for computational radiation dosimetry
Lee, C., Lodwick, D., Hurtado, J., Pafundi, D., Williams, J. L., & Bolch, W. E. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/2/002 · Cited by 345
Dimbylow, P. J. (1997) · Physics in Medicine and Biology · doi:10.1088/0031-9155/42/3/003 · Cited by 284
The GSF family of voxel phantoms
Petoussi-Henss, N., Zankl, M., Fill, U., & Regulla, D. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/1/307 · Cited by 280
Relevance of accurate Monte Carlo modeling in nuclear medical imaging
Zaidi, H. (1999) · Medical Physics · doi:10.1118/1.598559 · Cited by 279
Dimbylow, P. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/6/002 · Cited by 276
Development and application of the new dynamic Nurbs-based Cardiac-Torso (NCAT) phantom.
Segars, W. P., Tsui, B. M. W., Lalush, D. S., Frey, E. C., King, M., & Manocha, D. (2001) · ScholarWorks@UMassAmherst (University of Massachusetts Amherst) · Cited by 254
Kramer, R., Vieira, J. W., Khoury, H. J., Lima, F. R. A., & Fuelle, D. (2003) · Physics in Medicine and Biology · doi:10.1088/0031-9155/48/10/301 · Cited by 239
Population of anatomically variable 4D XCAT adult phantoms for imaging research and optimization
Segars, W. P., Bond, J., Frush, J., Hon, S., Eckersley, C., Williams, C. H., Feng, J., Tward, D. J., Ratnanather, J. T., Miller, M. I., et al. (2013) · Medical Physics · doi:10.1118/1.4794178 · Cited by 228
Handbook of Anatomical Models for Radiation Dosimetry
(2009) · CRC Press eBooks · doi:10.1201/ebk1420059793 · Cited by 225
Dosage determination with radioactive isotopes; practical considerations in therapy and protection.
Marinelli, L. D., Quimby, E. H., & Hine, G. J. (1948) · PubMed · Cited by 224
Zaidi, H., & Xu, X. G. (2007) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.9.060906.151934 · Cited by 219
Self-citationVoxel-based computational models of real human anatomy: a review
Caon, M. (2004) · Radiation and Environmental Biophysics · doi:10.1007/s00411-003-0221-8 · Cited by 213
Xu, X. G., Taranenko, V., Zhang, J., & Shi, C. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/23/017 · Cited by 197
Self-citationStabin, M. G., Watson, E. E., Cristy, M., Ryman, J. C., Eckerman, K. F., Davis, J. L., Marshall, D., & Gehlen, M. K. (1995) · doi:10.2172/91944 · Cited by 194
An instrumented phantom system for analog computation of treatment plans.
Alderson, S. W., Lanzl, L. H., ROLLINS, M., & SPIRA, J. (1962) · PubMed · Cited by 190
Hybrid computational phantoms of the male and female newborn patient: NURBS-based whole-body models
Lee, C., Lodwick, D., Hasenauer, D., Williams, J. L., Lee, C., & Bolch, W. E. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/12/001 · Cited by 184
Zankl, M., Veit, R., Williams, G., Schneider, K., Fendel, H., Petoussi, N., & Drexler, G. (1988) · Radiation and Environmental Biophysics · doi:10.1007/bf01214605 · Cited by 172
Bouchet, L. G., Bolch, W. E., Blanco, H. P., Wessels, B. W., Siegel, J. A., Rajon, D. A., Clairand, I., & Sgouros, G. (2003) · PubMed · Cited by 165
Organ dose conversion coefficients for external photon irradiation of male and female voxel models
Zankl, M., Fill, U., Petoussi-Henss, N., & Regulla, D. (2002) · Physics in Medicine and Biology · doi:10.1088/0031-9155/47/14/301 · Cited by 162
The Phantoms of Medical and Health Physics: Devices for Research and Development
DeWerd, L. A., & Kissick, M. W. (2013) · Biological and medical physics, biomedical engineering · doi:10.1007/978-1-4614-8304-5 · Cited by 156
Jiang, H., Wang, B., Xu, X. G., Suit, H. D., & Paganetti, H. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/18/007 · Cited by 150
Self-citationQuantitative cardiac SPECT reconstruction with reduced image degradation due to patient anatomy
Tsui, B. M. W., Zhao, X., Gregoriou, G. K., Lalush, D. S., Frey, E. C., Johnston, R. E., & McCartney, W. H. (1994) · IEEE Transactions on Nuclear Science · doi:10.1109/23.340655 · Cited by 147
Tsui, B. M. W., Terry, J. A., & Gullberg, G. T. (1993) · Investigative Radiology · doi:10.1097/00004424-199312000-00004 · Cited by 138
Geyer, A. M., O’Reilly, S. E., Lee, C., Long, D., & Bolch, W. E. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/18/5225 · Cited by 134
Kramer, R., Khoury, H. J., Vieira, J. W., Loureiro, E. C. M., Lima, V. J. M., Lima, F. R. A., & Hoff, G. (2004) · Physics in Medicine and Biology · doi:10.1088/0031-9155/49/23/001 · Cited by 131
Gu, J., Bednarz, B. P., Caracappa, P. F., & Xu, X. G. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/9/007 · Cited by 130
Self-citationMAX06 and FAX06: update of two adult human phantoms for radiation protection dosimetry
Kramer, R. A., Khoury, H. J., Vieira, J. W., & Lima, V. J. M. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/51/14/003 · Cited by 129
Taddei, P. J., Mirković, D., Fontenot, J. D., Giebeler, A., Zheng, Y., Kornguth, D. G., Mohan, R., & Newhauser, W. D. (2009) · Physics in Medicine and Biology · doi:10.1088/0031-9155/54/8/001 · Cited by 125
Caon, M., Bibbo, G., & Pattison, J. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/9/309 · Cited by 123
Nagaoka, T., Togashi, T., Saito, K., Takahashi, M., Ito, K., & Watanabe, S. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/22/012 · Cited by 120
Dosage determination with radioactive isotopes.
Marinelli, L. D., Quimby, E. H., & Hine, G. J. (1948) · PubMed · Cited by 119
Fill, U. A., Zankl, M., Petoussi-Henss, N., Siebert, M., & Regulla, D. F. (2004) · Health Physics · doi:10.1097/00004032-200403000-00003 · Cited by 111
Schlattl, H., Zankl, M., & Petoussi-Henss, N. (2007) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/8/006 · Cited by 110
The UF series of tomographic computational phantoms of pediatric patients
Lee, C., Williams, J. L., Lee, C., & Bolch, W. E. (2005) · Medical Physics · doi:10.1118/1.2107067 · Cited by 110
An image-based skeletal dosimetry model for the ICRP reference adult male—internal electron sources
Hough, M. C., Johnson, P. B., Rajon, D. A., Jokisch, D. W., Lee, C., & Bolch, W. E. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/8/001 · Cited by 110
Jones, D. G. (1997) · Radiation Protection Dosimetry · doi:10.1093/oxfordjournals.rpd.a032072 · Cited by 105
Pretorius, P. H., Xia, W., King, M. A., Tsui, B. M. W., Pan, T. S., & Villegas, B. J. (1997) · PubMed · Cited by 102
Ding, A., Mille, M. M., Liu, T., Caracappa, P. F., & Xu, X. G. (2012) · Physics in Medicine and Biology · doi:10.1088/0031-9155/57/9/2441 · Cited by 102
Self-citationKim, C. H., Choi, S. H., Jeong, J. H., Lee, C., & Chung, M. S. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/15/006 · Cited by 100
Chao, T., Bozkurt, A., & Xu, X. G. (2001) · Health Physics · doi:10.1097/00004032-200108000-00010 · Cited by 98
Self-citationLee, C., Lodwick, D. L., Williams, J. L., & Bolch, W. E. (2008) · Medical Physics · doi:10.1118/1.2912178 · Cited by 95
Eom, J., Xu, X. G., De, S., & Shi, C. (2010) · Medical Physics · doi:10.1118/1.3455276 · Cited by 95
Self-citationNagaoka, T., Kunieda, E., & Watanabe, S. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/23/004 · Cited by 94
Na, Y. H., Zhang, B., Zhang, J., Caracappa, P. F., & Xu, X. G. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/13/015 · Cited by 90
Self-citationTissue doses from radiotherapy of cancer of the uterine cervix
Stovall, M., Smith, S. A., & Rosenstein, M. (1989) · Medical Physics · doi:10.1118/1.596331 · Cited by 87
Review of Computational Anthropomorphic Anatomical and Physiological Models
Zaidi, H., & Tsui, B. M. W. (2009) · Proceedings of the IEEE · doi:10.1109/jproc.2009.2032852 · Cited by 87
Japanese adult male voxel phantom constructed on the basis of CT images
Sato, K., Noguchi, H., Emoto, Y., Koga, S., & Saitô, K. (2006) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncl101 · Cited by 86
Hybrid computational phantoms for medical dose reconstruction
Bolch, W. E., Lee, C., Wayson, M. B., & Johnson, P. B. (2009) · Radiation and Environmental Biophysics · doi:10.1007/s00411-009-0260-x · Cited by 83
High-resolution human anatomy models for advanced electromagnetic field computations
Gjonaj, E., Bartsch, M., Clemens, M., Schupp, S., & Weiland, T. (2002) · IEEE Transactions on Magnetics · doi:10.1109/20.996096 · Cited by 79
Yeom, Y. S., Jeong, J. H., Kim, C. H., Han, M. C., Ham, B. K., Cho, K. W., & Hwang, S. B. (2014) · Physics in Medicine and Biology · doi:10.1088/0031-9155/59/14/3969 · Cited by 79
Therapeutic Applications of Monte Carlo Calculations in Nuclear Medicine
Ewell, L. (2003) · Medical Physics · doi:10.1118/1.1603742 · Cited by 77
Chao, T., & Xu, X. (2001) · Physics in Medicine and Biology · doi:10.1088/0031-9155/46/4/301 · Cited by 74
Self-citationKim, C. H., Jeong, J. H., Bolch, W. E., Cho, K.-W., & Hwang, S. B. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/10/016 · Cited by 74
DISTRIBUTION OF DOSE IN THE BODY FROM A SOURCE OF GAMMA RAYS DISTRIBUTED UNIFORMLY IN AN ORGAN
Hl, F., & Snyder, W. S. (1968) · Elsevier eBooks · doi:10.1016/b978-1-4832-8312-8.50220-4 · Cited by 68
Zhang, B., Ma, J., Liu, L., & Cheng, J. (2007) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncm184 · Cited by 64
Bozkurt, A., & Bor, D. (2006) · Physics in Medicine and Biology · doi:10.1088/0031-9155/52/2/001 · Cited by 62
Smith, T., Petoussi-Henss, N., & Zankl, M. (2000) · European Journal of Nuclear Medicine and Molecular Imaging · doi:10.1007/s002590000294 · Cited by 57
Bozkurt, A., Chao, T., Xu, X., Bozkurt, A., & Chao, T. (2000) · Physics in Medicine and Biology · doi:10.1088/0031-9155/45/10/321 · Cited by 55
Self-citationGSF male and female adult voxel models representing ICRP reference man-The present status
Zankl, M., Becker, J., Fill, U. A., Petoussi-Henss, N., & Kf, E. (2005) · Site cant be reached · Cited by 55
Goos, G., Leeuwen, J. V., & Hartmanis, J. (2001) · Lecture notes in computer science · doi:10.1007/3-540-45488-8 · Cited by 51
Conversion of ICRP male reference phantom to polygon-surface phantom
Yeom, Y. S., Han, M. C., Kim, C. H., & Jeong, J. H. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/19/6985 · Cited by 50
An image-based skeletal dosimetry model for the ICRP reference newborn—internal electron sources
Pafundi, D., Rajon, D. A., Jokisch, D. W., Lee, C., & Bolch, W. E. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/7/002 · Cited by 49
Korean adult male voxel model KORMAN segmented from magnetic resonance images
Lee, C., Lee, J., & Lee, C. (2004) · Medical Physics · doi:10.1118/1.1689013 · Cited by 49
Bozkurt, A., Chao, T., & Xu, X. (2001) · Health Physics · doi:10.1097/00004032-200108000-00011 · Cited by 49
Self-citationConstruction of an extended library of adult male 3D models: rationale and results
Broggio, D., Beurrier, J., Brémaud, M., Desbrée, A., Farah, J., Huet, C., & Franck, D. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/23/020 · Cited by 46
Veress, A. I., Segars, W. P., Tsui, B. M. W., & Gullberg, G. T. (2010) · IEEE Transactions on Medical Imaging · doi:10.1109/tmi.2010.2089801 · Cited by 44
Dimbylow, P. J., Bolch, W. E., & Lee, C. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/5/017 · Cited by 43
Prediction of myelotoxicity using radiation doses to marrow from body, blood and marrow sources.
Lim, S. M., DeNardo, G. L., DeNardo, D. A., Shen, S., Yuan, A., OʼDonnell, R. T., & DeNardo, S. J. (1997) · PubMed · Cited by 39
Zhang, J., Xu, X. G., Shi, C., & Fuß, M. (2008) · Journal of Applied Clinical Medical Physics · doi:10.1120/jacmp.v9i1.2700 · Cited by 38
Self-citationComputational lymphatic node models in pediatric and adult hybrid phantoms for radiation dosimetry
Lee, C., Lamart, S., & Moroz, B. E. (2013) · Physics in Medicine and Biology · doi:10.1088/0031-9155/58/5/n59 · Cited by 31
Calculation of organ doses in x-ray examinations of premature babies
Smans, K., Tapiovaara, M. J., Cannie, M., Struelens, L., Vanhavere, F., Smet, M., & Bosmans, H. (2008) · Medical Physics · doi:10.1118/1.2828183 · Cited by 30
McGurk, R., Seco, J. C., Riboldi, M., Wolfgang, J. A., Segars, W. P., & Paganetti, H. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/5/014 · Cited by 28
Márquez, G., Wang, L. V., Wang, C., & Hu, Z. (1999) · Physics in Medicine and Biology · doi:10.1088/0031-9155/44/1/022 · Cited by 27
Zhang, G., Liu, Q., Zeng, S., & Luo, Q. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/14/001 · Cited by 27
Bahadori, A. A., Baalen, M. G. V., Shavers, M. R., Dodge, C., Semones, E., & Bolch, W. E. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/6/010 · Cited by 25
Development of a Japanese Adult Female Voxel Phantom
Sato, K., Noguchi, H., Emoto, Y., Koga, S., & Saitô, K. (2009) · Journal of Nuclear Science and Technology · doi:10.1080/18811248.2009.9711599 · Cited by 24
Hegenbart, L., Na, Y. H., Zhang, J. Y., Urban, M., & Xu, X. G. (2008) · Physics in Medicine and Biology · doi:10.1088/0031-9155/53/19/017 · Cited by 20
Self-citationStatistical construction of a Japanese male liver phantom for internal radionuclide dosimetry
Mofrad, F. B., Zoroofi, R. A., Tehrani‐Fard, A. A., Akhlaghpoor, S., Hori, M., Chen, Y.-W., & Sato, Y. (2010) · Radiation Protection Dosimetry · doi:10.1093/rpd/ncq164 · Cited by 19
Computational high-resolution heart phantoms for medical imaging and dosimetry simulations
Gu, S., Gupta, R., & Kyprianou, I. S. (2011) · Physics in Medicine and Biology · doi:10.1088/0031-9155/56/18/005 · Cited by 16
Sun, W., JIA, X., XIE, T., XU, F., & Liu, Q. (2012) · Journal of Radiation Research · doi:10.1093/jrr/rrs100 · Cited by 16
Choi, S. H., Lee, C., Cho, S. K., et al. (2007) · Springer eBooks · doi:10.1007/978-3-540-36841-0_1066 · Cited by 7
Courageot, E., Sayah, R., & Huet, C. (2010) · Physics in Medicine and Biology · doi:10.1088/0031-9155/55/9/n02 · Cited by 6
MATSIM: Development of a Voxel Model of the MATROSHKA Astronaut Dosimetric Phantom
Beck, P. J., Zechner, A., Rollet, S., Berger, T., Bergmann, R., Hajek, M., Hranitzky, C., Latocha, M., Reitz, G., Stadtmann, H., et al. (2011) · IEEE Transactions on Nuclear Science · doi:10.1109/tns.2011.2157704 · Cited by 5
Cited by
Nuclear physics in particle therapy: a review
Durante, M., & Paganetti, H. (2016) · Reports on Progress in Physics · doi:10.1088/0034-4885/79/9/096702 · Cited by 345
Virtual clinical trials in medical imaging: a review
Abadi, E., Segars, W. P., Tsui, B. M. W., Kinahan, P. E., Bottenus, N., Frangi, A. F., Maidment, A., Lo, J., & Samei, E. (2020) · Journal of Medical Imaging · doi:10.1117/1.jmi.7.4.042805 · Cited by 224
Tissue mimicking materials for imaging and therapy phantoms: a review
McGarry, C. K., Grattan, L. J., Ivory, A. M., Leek, F., Liney, G. P., Liu, Y., Miloro, P., Rai, R., Robinson, A., Shih, A. J., et al. (2020) · Physics in Medicine & Biology · doi:10.1088/1361-6560/abbd17 · Cited by 215
Lee, C., Kim, K. P., Bolch, W. E., Moroz, B. E., & Folio, L. (2015) · Journal of Radiological Protection · doi:10.1088/0952-4746/35/4/891 · Cited by 197
Kainz, W., Neufeld, E., Bolch, W. E., Graff, C. G., Kim, C. H., Kuster, N., Lloyd, B., Morrison, T., Segars, P., Yeom, Y. S., et al. (2019) · IEEE Transactions on Radiation and Plasma Medical Sciences · doi:10.1109/trpms.2018.2883437 · Cited by 109
“A more comprehensive list can be found in the review papers by Xu [6], Zaidi and Xu [82], and Zaidi and Tsui [83].”
InfluentialSelf-citation
Metadata
- Authors
- Xu, X. G.
- Venue
- Physics in Medicine and Biology
- Publisher
- IOP Publishing
- Published
- 2014-08-21
- Volume
- 59
- Issue
- 18
- Pages
- R233-R302
- ISSN
- 0031-9155 (ISSN-L)
- 1361-6560
- OpenAlex
- W2015421863
- Cited by
- 280
- References
- 104
- FWCI
- 14.19
- Type
- journal article
- Language
- en
- Open access
- hybrid
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.