Biosensors: recent advances
Open accessThe DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Abstract
This review discusses recent advances in biosensor technology which draw on the disciplines of physics, chemistry, biochemistry and electronics. We first show that a biosensor consists of three components, a biological detection system, a transducer and an output system. Biological receptors are briefly reviewed, followed by a detailed discussion of immobilization procedures for the efficacious attachment of receptor molecules to a transducer surface. Two classes of transducers, optical and piezoelectric, which involve interesting physics and show particular promise for commercial biosensors, are discussed thoroughly. We comment briefly on practical factors affecting the commercialization of various biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Verwendung von Schwingquarzen zur W�gung d�nner Schichten und zur Mikrow�gung
Sauerbrey, G. (1959) · Zeitschrift f�r Physik · doi:10.1007/bf01337937 · Cited by 9,653
Saiki, R. K., Scharf, S., Faloona, F., Mullis, K. B., Horn, G. T., Erlich, H. A., & Arnheim, N. (1985) · Science · doi:10.1126/science.2999980 · Cited by 8,956
Use of quartz vibration for weighing thin films on a microbalance
Sauerbrey, G., & Sauerbrey, F. (1959) · The European Physical Journal A · Cited by 6,791
The use of quarts oscillators for weighing thin layers and for microweighing
Sauerbrey, G., & Sauerbrey, G. (1959) · Medical Entomology and Zoology · Cited by 4,456
Ellipsometry and Polarized Light
Azzam, R. M. A., Bashara, N. M., & Ballard, S. S. (1978) · Physics Today · doi:10.1063/1.2994821 · Cited by 4,280
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Notizen: Radiative Decay of Non Radiative Surface Plasmons Excited by Light
Kretschmann, E., & Raether, H. (1968) · Zeitschrift für Naturforschung A · doi:10.1515/zna-1968-1247 · Cited by 3,377
Otto, A. (1968) · Zeitschrift für Physik A Hadrons and nuclei · doi:10.1007/bf01391532 · Cited by 3,065
Surface plasmon resonance for gas detection and biosensing
Liedberg, B., Nylander, C., & Lunström, I. (1983) · Sensors and Actuators · doi:10.1016/0250-6874(83)85036-7 · Cited by 2,539
UPDIKE, S. J., & HICKS, G. P. (1967) · Nature · doi:10.1038/214986a0 · Cited by 1,336
Cited by
Integrated Nanoparticle–Biomolecule Hybrid Systems: Synthesis, Properties, and Applications
Katz, E., & Willner, I. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200400651 · Cited by 2,450
Höök, F., Kasemo, B., Nylander, T., Fant, C., Sott, K., & Elwing, H. (2001) · Analytical Chemistry · doi:10.1021/ac0106501 · Cited by 1,162
Kasemo, B. (2002) · Surface Science · doi:10.1016/s0039-6028(01)01809-x · Cited by 1,079
Innovation in Layer-by-Layer Assembly
Richardson, J. J., Cui, J., Björnmalm, M., Braunger, J. A., Ejima, H., & Caruso, F. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00627 · Cited by 922
Self-citationSurface acoustic wave biosensors: a review
Länge, K., Rapp, B. E., & Rapp, M. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-1911-5 · Cited by 806
Recent advances in ZnO nanostructures and thin films for biosensor applications: Review
Arya, S. K., Saha, S., Ramirez-Vick, J. E., Gupta, V., Bhansali, S., & Singh, S. P. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.05.048 · Cited by 579
Luka, G., Ahmadi, A., Najjaran, H., Alocilja, E., DeRosa, M., Wolthers, K., Malki, A., Aziz, H., Althani, A., & Hoorfar, M. (2015) · Sensors · doi:10.3390/s151229783 · Cited by 566
Protein-modified nanocrystalline diamond thin films for biosensor applications
Härtl, A., Schmich, E., Garrido, J. A., Hernando, J., Catharino, S. C. R., Walter, S., Feulner, P., Kromka, A., Steinmüller, D., & Stutzmann, M. (2004) · Nature Materials · doi:10.1038/nmat1204 · Cited by 519
In Situ Assembly of Colloidal Particles into Miniaturized Biosensors
Velev, O. D., & Kaler, E. W. (1999) · Langmuir · doi:10.1021/la981729c · Cited by 472
Bioencapsulation within synthetic polymers (Part 1): sol–gel encapsulated biologicals
Gill, I., & Ballesteros, A. (2000) · Trends in Biotechnology · doi:10.1016/s0167-7799(00)01457-8 · Cited by 463
Biosensor technology: Technology push versus market pull
Luong, J. H. T., Male, K. B., & Glennon, J. D. (2008) · Biotechnology Advances · doi:10.1016/j.biotechadv.2008.05.007 · Cited by 454
Biosensors as useful tools for environmental analysis and monitoring
Rodriguez-Mozaz, S., Lopez de Alda, M. J., & Barceló, D. (2006) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-006-0574-3 · Cited by 451
Polymer microring resonators for biochemical sensing applications
Chao, C.-Y., Fung, W., & Guo, L. J. (2006) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2005.862945 · Cited by 442
Biosensors as innovative tools for the detection of food borne pathogens
Arora, P., Sindhu, A., Dilbaghi, N., & Chaudhury, A. (2011) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2011.06.002 · Cited by 350
Biosensor Technology for Pesticides—A review
Verma, N., & Bhardwaj, A. (2015) · Applied Biochemistry and Biotechnology · doi:10.1007/s12010-015-1489-2 · Cited by 284
Biosensors - classification, characterization and new trends
Monošík, R., Streďanský, M., & Šturdík, E. (2012) · Acta Chimica Slovaca · doi:10.2478/v10188-012-0017-z · Cited by 269
Katz, E., & Willner, I. (2004) · Angewandte Chemie · doi:10.1002/ange.200400651 · Cited by 260
Beyond micromachining: the potential of diatoms
Parkinson, J., & Gordon, R. (1999) · Trends in Biotechnology · doi:10.1016/s0167-7799(99)01321-9 · Cited by 222
The role of biosensors in the detection of emerging infectious diseases
Pejcic, B., Marco, R. D., & Parkinson, G. (2006) · The Analyst · doi:10.1039/b603402k · Cited by 213
Biosensors: Classifications, medical applications, and future prospective
Alhadrami, H. A. (2018) · Biotechnology and Applied Biochemistry · doi:10.1002/bab.1621 · Cited by 193
“The key analytical enzymes that have been employed in these types of biosensors are oxidoreductases and hydrolases [25].”
MethodToxicity assessment using different bioassays and microbial biosensors
Hassan, S. H. A., Van Ginkel, S. W., Hussein, M. A. M., Abskharon, R., & Oh, S.-E. (2016) · Environment International · doi:10.1016/j.envint.2016.03.003 · Cited by 170
Zimmermann, J. L., Nicolaus, T., Neuert, G., & Blank, K. (2010) · Nature Protocols · doi:10.1038/nprot.2010.49 · Cited by 168
Cao, B., Li, L., Wu, H., Tang, Q., Sun, B., Dong, H., Zhe, J., & Cheng, G. (2014) · Chem. Commun. · doi:10.1039/c3cc48878k · Cited by 66
Aponte, V. M., Finch, D. S., & Klaus, D. M. (2006) · Life Sciences · doi:10.1016/j.lfs.2006.04.007 · Cited by 51
“This linear behavior between the change in frequency and the amount of material deposited on the surface of the crystals has been studied extensively since the late 1950s and is characterized by the Sauerbrey equation (Collings and Caruso, 1997).”
Plasmonic metagratings for simultaneous determination of Stokes parameters
Pors, A., Nielsen, M. G., & Bozhevolnyi, S. I. (2015) · Optica · doi:10.1364/optica.2.000716 · Cited by 13
“, ellipsometry), astronomy[4], and biology[5].”
Metadata
- Authors
- Collings, A. F., & Caruso, F.
- Venue
- Reports on Progress in Physics
- Publisher
- IOP Publishing
- Published
- 1997-11-01
- Volume
- 60
- Issue
- 11
- Pages
- 1397-1445
- ISSN
- 0034-4885 (ISSN-L)
- 1361-6633
- OpenAlex
- W2099382155
- Cited by
- 258
- References
- 74
- FWCI
- 1.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.