Biosensors: recent advances
Open accessThe DOI matches its Crossref record; 74 of the 74 references it cites were found in a registry or an index.
Abstract
This review discusses recent advances in biosensor technology which draw on the disciplines of physics, chemistry, biochemistry and electronics. We first show that a biosensor consists of three components, a biological detection system, a transducer and an output system. Biological receptors are briefly reviewed, followed by a detailed discussion of immobilization procedures for the efficacious attachment of receptor molecules to a transducer surface. Two classes of transducers, optical and piezoelectric, which involve interesting physics and show particular promise for commercial biosensors, are discussed thoroughly. We comment briefly on practical factors affecting the commercialization of various biosensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Verwendung von Schwingquarzen zur W�gung d�nner Schichten und zur Mikrow�gung
Sauerbrey, G. (1959) · Zeitschrift f�r Physik · doi:10.1007/bf01337937 · Cited by 9,653
Saiki, R. K., Scharf, S., Faloona, F., Mullis, K. B., Horn, G. T., Erlich, H. A., & Arnheim, N. (1985) · Science · doi:10.1126/science.2999980 · Cited by 8,956
Use of quartz vibration for weighing thin films on a microbalance
Sauerbrey, G., & Sauerbrey, F. (1959) · The European Physical Journal A · Cited by 6,791
The use of quarts oscillators for weighing thin layers and for microweighing
Sauerbrey, G., & Sauerbrey, G. (1959) · Medical Entomology and Zoology · Cited by 4,456
Ellipsometry and Polarized Light
Azzam, R. M. A., Bashara, N. M., & Ballard, S. S. (1978) · Physics Today · doi:10.1063/1.2994821 · Cited by 4,280
ELECTRODE SYSTEMS FOR CONTINUOUS MONITORING IN CARDIOVASCULAR SURGERY
Clark, L. C., & Lyons, C. (1962) · Annals of the New York Academy of Sciences · doi:10.1111/j.1749-6632.1962.tb13623.x · Cited by 3,945
Notizen: Radiative Decay of Non Radiative Surface Plasmons Excited by Light
Kretschmann, E., & Raether, H. (1968) · Zeitschrift für Naturforschung A · doi:10.1515/zna-1968-1247 · Cited by 3,377
Otto, A. (1968) · Zeitschrift für Physik A Hadrons and nuclei · doi:10.1007/bf01391532 · Cited by 3,065
Surface plasmon resonance for gas detection and biosensing
Liedberg, B., Nylander, C., & Lunström, I. (1983) · Sensors and Actuators · doi:10.1016/0250-6874(83)85036-7 · Cited by 2,539
UPDIKE, S. J., & HICKS, G. P. (1967) · Nature · doi:10.1038/214986a0 · Cited by 1,336
Johnsson, B., Löfås, S., & Lindquist, G. (1991) · Analytical Biochemistry · doi:10.1016/0003-2697(91)90424-r · Cited by 1,262
Three-Dimensional Structure of an Antigen-Antibody Complex at 2.8 Å Resolution
Amit, A. G., Mariuzza, R. A., Phillips, S. E. V., & Poljak, R. J. (1986) · Science · doi:10.1126/science.2426778 · Cited by 1,182
Karlsson, R., Michaelsson, A., & Mattsson, L. (1991) · Journal of Immunological Methods · doi:10.1016/0022-1759(91)90331-9 · Cited by 1,077
Built-Up Films of Barium Stearate and Their Optical Properties
Blodgett, K. B., & Langmuir, I. (1937) · Physical Review · doi:10.1103/physrev.51.964 · Cited by 1,065
Stenberg, E., Persson, B., Roos, H., & Urbaniczky, C. (1991) · Journal of Colloid and Interface Science · doi:10.1016/0021-9797(91)90284-f · Cited by 1,059
Jönsson, U., Fägerstam, L. G., Ivarsson, B., Johnsson, B., Karlsson, R., Lundh, K., Löfås, S., Persson, B. S., Roos, H., & Rönnberg, I. (1991) · PubMed · Cited by 902
Enzymes and Other Proteins Entrapped in Sol-Gel Materials
Avnir, D., Braun, S., Lev, O., & Ottolenghi, M. (1994) · Chemistry of Materials · doi:10.1021/cm00046a008 · Cited by 836
Piezoelectric Sorption Detector.
King, W. H. (1964) · Analytical Chemistry · doi:10.1021/ac60215a012 · Cited by 786
Löfås, S., & Johnsson, B. (1990) · J. Chem. Soc., Chem. Commun. · doi:10.1039/c39900001526 · Cited by 766
Gas detection by means of surface plasmon resonance
Nylander, C., Liedberg, B., & Lind, T. (1982) · Sensors and Actuators · doi:10.1016/0250-6874(82)80008-5 · Cited by 745
Lvov, Y., Decher, G., & Sukhorukov, G. (1993) · Macromolecules · doi:10.1021/ma00072a016 · Cited by 482
A review of the immobilization of enzymes in electropolymerized films
Barlett, P. N., & Cooper, J. M. (1993) · Journal of Electroanalytical Chemistry · doi:10.1016/0022-0728(93)80001-x · Cited by 472
Mechanism of operation and design considerations for surface acoustic wave device vapour sensors
Wohltjen, H. (1984) · Sensors and Actuators · doi:10.1016/0250-6874(84)85014-3 · Cited by 465
Fägerstam, L. G., Frostell-Karlsson, Å., Karlsson, R., Persson, B., & Rönnberg, I. (1992) · Journal of Chromatography A · doi:10.1016/0021-9673(92)80137-j · Cited by 437
御子柴, 宣. (1974) · 日本物理學會誌 · Cited by 420
Chemical Sensors Based on Fiber Optics
Seitz, W. R. (1984) · Analytical Chemistry · doi:10.1021/ac00265a001 · Cited by 417
Three-dimensional structure of an intact human immunoglobulin.
Silverton, E. W., Navia, M. A., & Davies, D. R. (1977) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.74.11.5140 · Cited by 375
Vroman, L., & Adams, A. L. (1969) · Surface Science · doi:10.1016/0039-6028(69)90037-5 · Cited by 368
Piezoelectric crystal biosensor modified with protein A for determination of immunoglobulins
Muramatsu, H., Dicks, J. M., Tamiya, E., & Karube, I. (1987) · Analytical Chemistry · doi:10.1021/ac00150a007 · Cited by 350
Surface plasmon spectroscopy of organic monolayer assemblies
Pockrand, I., Swalen, J. D., Gordon, J. G., & Philpott, M. R. (1978) · Surface Science · doi:10.1016/0039-6028(78)90283-2 · Cited by 319
Microgravimetric immunoassay with piezoelectric crystals
Roederer, J. E., & Bastiaans, G. J. (1983) · Analytical Chemistry · doi:10.1021/ac00264a030 · Cited by 314
Schultz, J. S., Mansouri, S., & Goldstein, I. J. (1982) · Diabetes Care · doi:10.2337/diacare.5.3.245 · Cited by 305
Fiber-Optic Sensors for Biomedical Applications
Peterson, J. I., & Vurek, G. G. (1984) · Science · doi:10.1126/science.6422554 · Cited by 300
Chemical Sensors Based on Immobilized Indicators and Fiber Optics
Seitz, W. R., & Sepaniak, M. J. (1988) · C R C Critical Reviews in Analytical Chemistry · doi:10.1080/10408348808085620 · Cited by 272
Enzyme or protein immobilization techniques for applications in biosensor design
Scouten, W. H., Luong, J. H. T., & Brown, R. S. (1995) · Trends in biotechnology · doi:10.1016/s0167-7799(00)88935-0 · Cited by 269
Haeussling, L., Ringsdorf, H., Schmitt, F., & Knoll, W. (1991) · Langmuir · doi:10.1021/la00057a001 · Cited by 264
Biosensors for chemical and biological agents of defence interest
Paddle, B. M. (1996) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(96)82333-5 · Cited by 240
Recent developments in instrumentation in ellipsometry
Hauge, P. S. (1980) · Surface Science · doi:10.1016/0039-6028(80)90297-6 · Cited by 239
Cullen, D. C., Brown, R. G. W., & Lowe, C. R. (1987) · Biosensors · doi:10.1016/0265-928x(87)85002-2 · Cited by 224
MacCraith, B. D., McDonagh, C. M., O'Keeffe, G., Keyes, E. T., Vos, J. G., O'Kelly, B., & McGilp, J. F. (1993) · The Analyst · doi:10.1039/an9931800385 · Cited by 215
Acoustic wave viscosity sensor
Ricco, A. J., & Martin, S. J. (1987) · Applied Physics Letters · doi:10.1063/1.97804 · Cited by 206
Sol-gel coatings for optical chemical sensors and biosensors
MacCraith, B. D., McDonagh, C. M., O'Keeffe, G., McEvoy, A. K., Butler, T., & Sheridan, F. R. (1995) · Sensors and Actuators B: Chemical · doi:10.1016/0925-4005(95)01662-7 · Cited by 188
Kajiya, Y., Sugai, H., Iwakura, C., & Yoneyama, H. (1991) · Analytical Chemistry · doi:10.1021/ac00001a009 · Cited by 184
Ji, T. H. (1979) · Biochimica et Biophysica Acta (BBA) - Reviews on Biomembranes · doi:10.1016/0304-4157(79)90007-8 · Cited by 184
Parathion antibodies on piezoelectric crystals
Ngeh-Ngwainbi, J., Foley, P. H., Kuan, S. S., & Guilbault, G. G. (1986) · Journal of the American Chemical Society · doi:10.1021/ja00278a012 · Cited by 177
Attridge, J. W., Daniels, P. B., Deacon, J. K., Robinson, G. A., & Davidson, G. P. (1991) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(91)80005-i · Cited by 167
Biosensors: recent trends. A review
Vadgama, P. M., & Crump, P. W. (1992) · The Analyst · doi:10.1039/an9921701657 · Cited by 163
Optical Properties of Thin Layers of Bovine Serum Albumin, γ-Globulin, and Hemoglobin*
Arwin, H. (1986) · Applied Spectroscopy · doi:10.1366/0003702864509204 · Cited by 142
Comparison of the QCM and the SPR method for surface studies and immunological applications
Köβlinger, C., Uttenthaler, E., Drost, S., Aberl, F., Wolf, H. J., Brink, G., Stanglmaier, A., & Sackmann, E. (1995) · Sensors and Actuators B Chemical · doi:10.1016/0925-4005(95)85023-6 · Cited by 141
Chemical Sensors and Biosensors—Principles and Applications
Cammann, K., Lemke, U., Rohen, A., Sander, J., Wilken, H., & Winter, B. (1991) · Angewandte Chemie International Edition in English · doi:10.1002/anie.199105161 · Cited by 127
Immunosensors: Antibody-based biosensors
North, J. R. (1985) · Trends in Biotechnology · doi:10.1016/0167-7799(85)90119-2 · Cited by 123
Hegner, M., Wagner, P., & Semenza, G. (1993) · FEBS Letters · doi:10.1016/0014-5793(93)80854-n · Cited by 122
du Poët, P. D. T., Miyamoto, S., Murakami, T., Kimura, J., & Karube, I. (1990) · Analytica Chimica Acta · doi:10.1016/s0003-2670(00)82082-6 · Cited by 108
Opto-electronic immunosensors: A review of optical immunoassay at continuous surfaces
Place, J. F., Sutherland, R. M., & Dähne, C. (1985) · Biosensors · doi:10.1016/0265-928x(85)80004-3 · Cited by 107
AFM Studies of Protein Adsorption
Cullen, D. C., & Lowe, C. R. (1994) · Journal of Colloid and Interface Science · doi:10.1006/jcis.1994.1276 · Cited by 107
Ellipsometry as a tool to study protein films at liquid-solid interfaces
Cuypers, P., Hermens, W. T., & Hemker, H. C. (1978) · Analytical Biochemistry · doi:10.1016/0003-2697(78)90483-9 · Cited by 104
A surface plasmon resonance immunosensor based on the streptavidin-biotin complex
Morgan, H., & Taylor, D. M. (1992) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(92)85039-d · Cited by 96
Direct observation of immunoglobulin adsorption dynamics using the atomic force microscope
Lin, J. N., Drake, B., Lea, S., Hansma, P. K., & Andrade, J. D. (1990) · Langmuir · doi:10.1021/la00092a036 · Cited by 87
Fourier Transform Infrared Spectroscopy of Protein Adsorption from Whole Blood: Ex Vivo Dog Studies
Gendreau, R. M., Winters, S., Leininger, R. I., Fink, D. J., Hassler, C. R., & Jakobsen, R. J. (1981) · Applied Spectroscopy · doi:10.1366/0003702814732562 · Cited by 85
The three-dimensional structure of antibodies
Marquart, M., & Deisenhofer, J. (1982) · Immunology Today · doi:10.1016/0167-5699(82)90107-4 · Cited by 74
Surface plasmon resonance studies of immunoreactions utilizing disposable diffraction gratings
Lawrence, C. R., Geddes, N. J., Furlong, D. N., & Sambles, J. R. (1996) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(96)82734-5 · Cited by 74
Immunoassay based on surface plasmon oscillations
Mayo, C. S., & Hallock, R. B. (1989) · Journal of Immunological Methods · doi:10.1016/0022-1759(89)90295-0 · Cited by 62
Geddes, N. J., Martin, A. S., Caruso, F., Urquhart, R. S., Furlong, D. N., Sambles, J. R., Than, K. A., & Edgar, J. A. (1994) · Journal of Immunological Methods · doi:10.1016/0022-1759(94)90358-1 · Cited by 52
Self-citationProbing Protein Adsorption: Total Internal Reflection Intrinsic Fluorescence
Wagenen, R. A. V., Rockhold, S. A., & Andrade, J. D. (1982) · Advances in chemistry series · doi:10.1021/ba-1982-0199.ch023 · Cited by 52
Current developments in optical biochemical sensors
Narayanaswamy, R. (1991) · Biosensors and Bioelectronics · doi:10.1016/0956-5663(91)85044-w · Cited by 41
A solid-phase optoelectronic sensor for serum albumin
Goldfinch, M. J., & Lowe, C. R. (1980) · Analytical Biochemistry · doi:10.1016/0003-2697(80)90639-9 · Cited by 41
Continuous ex vivo and in vivo monitoring with chemical sensors
Fogt, E. J. (1990) · Clinical Chemistry · doi:10.1093/clinchem/36.8.1573 · Cited by 30
Biosensors for process monitoring
Scheper, T. H. (1992) · Journal of Industrial Microbiology & Biotechnology · doi:10.1007/bf01569620 · Cited by 28
Chemically modified cellulose acetate membrane for biosensor applications
Gunasingham, H., Teo, P. Y. T., Lai, Y., & Tan, S.-G. (1989) · Biosensors · doi:10.1016/0265-928x(89)80001-x · Cited by 21
Gölander, C.-G., Hlady, V., Caldwell, K. D., & Andrade, J. D. (1990) · Colloids and Surfaces · doi:10.1016/0166-6622(90)80257-5 · Cited by 21
Lowe, C. R., Hin, B. F. Y. Y., Cullen, D. C., et al. (1990) · Journal of Chromatography A · doi:10.1016/s0021-9673(01)93769-0 · Cited by 21
Freitag, R. (1993) · Current Opinion in Biotechnology · doi:10.1016/0958-1669(93)90036-v · Cited by 21
Towards a fluorescent chemoreceptive lipid membrane-based optode
Krull, U. J. (1988) · Talanta · doi:10.1016/0039-9140(88)80051-1 · Cited by 19
Ellipsometric Techniques to Study Surfaces and Thin Films
Rzhanov, A. V., & Svitashev, K. K. (1979) · Advances in Electronics and Electron Physics · doi:10.1016/s0065-2539(08)60765-9 · Cited by 17
Cited by
Integrated Nanoparticle–Biomolecule Hybrid Systems: Synthesis, Properties, and Applications
Katz, E., & Willner, I. (2004) · Angewandte Chemie International Edition · doi:10.1002/anie.200400651 · Cited by 2,450
Höök, F., Kasemo, B., Nylander, T., Fant, C., Sott, K., & Elwing, H. (2001) · Analytical Chemistry · doi:10.1021/ac0106501 · Cited by 1,162
Kasemo, B. (2002) · Surface Science · doi:10.1016/s0039-6028(01)01809-x · Cited by 1,079
Innovation in Layer-by-Layer Assembly
Richardson, J. J., Cui, J., Björnmalm, M., Braunger, J. A., Ejima, H., & Caruso, F. (2016) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00627 · Cited by 922
Self-citationSurface acoustic wave biosensors: a review
Länge, K., Rapp, B. E., & Rapp, M. (2008) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-008-1911-5 · Cited by 806
Metadata
- Authors
- Collings, A. F., & Caruso, F.
- Venue
- Reports on Progress in Physics
- Publisher
- IOP Publishing
- Published
- 1997-11-01
- Volume
- 60
- Issue
- 11
- Pages
- 1397-1445
- ISSN
- 0034-4885 (ISSN-L)
- 1361-6633
- OpenAlex
- W2099382155
- Cited by
- 258
- References
- 74
- FWCI
- 1.57
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.