A review of micropumps
The DOI matches its Crossref record; 70 of the 70 references it cites were found in a registry or an index.
Abstract
We survey progress over the past 25 years in the development of microscale devices for pumping fluids. We attempt to provide both a reference for micropump researchers and a resource for those outside the field who wish to identify the best micropump for a particular application. Reciprocating displacement micropumps have been the subject of extensive research in both academia and the private sector and have been produced with a wide range of actuators, valve configurations and materials. Aperiodic displacement micropumps based on mechanisms such as localized phase change have been shown to be suitable for specialized applications. Electroosmotic micropumps exhibit favorable scaling and are promising for a variety of applications requiring high flow rates and pressures. Dynamic micropumps based on electrohydrodynamic and magnetohydrodynamic effects have also been developed. Much progress has been made, but with micropumps suitable for important applications still not available, this remains a fertile area for future research.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Physical chemistry of surfaces
(1998) · Choice Reviews Online · doi:10.5860/choice.35-4499 · Cited by 11,648
High-performance heat sinking for VLSI
Tuckerman, D. B., & Pease, R. F. W. (1981) · IEEE Electron Device Letters · doi:10.1109/edl.1981.25367 · Cited by 5,291
Monolithic Microfabricated Valves and Pumps by Multilayer Soft Lithography
Unger, M. A., Chou, H.-P., Thorsen, T., Scherer, A., & Quake, S. R. (2000) · Science · doi:10.1126/science.288.5463.113 · Cited by 4,010
Introduction to Electrodynamics
Griffiths, D. J. (2017) · Cambridge University Press eBooks · doi:10.1017/9781108333511 · Cited by 3,408
Roark's Formulas for Stress and Strain
Roark, R. J., & Young, W. C. (1938) · Cited by 3,020
Silicon as a mechanical material
Petersen, K. E. (1982) · Proceedings of the IEEE · doi:10.1109/proc.1982.12331 · Cited by 2,902
Zeta Potential in Colloid Science
(1981) · Elsevier eBooks · doi:10.1016/c2013-0-07389-6 · Cited by 2,328
Micro Total Analysis Systems. 1. Introduction, Theory, and Technology
Reyes, D. R., Iossifidis, D., Auroux, P.-A., & Manz, A. (2002) · Analytical Chemistry · doi:10.1021/ac0202435 · Cited by 2,191
Fundamentals of Microfabrication
Madou, M. J. (2018) · CRC Press eBooks · doi:10.1201/9781482274004 · Cited by 2,020
Micromachining a Miniaturized Capillary Electrophoresis-Based Chemical Analysis System on a Chip
Harrison, D. J., Fluri, K., Seiler, K., Fan, Z., Effenhauser, C. S., & Manz, A. (1993) · Science · doi:10.1126/science.261.5123.895 · Cited by 1,800
Cited by
The origins and the future of microfluidics
Whitesides, G. M. (2006) · Nature · doi:10.1038/nature05058 · Cited by 9,687
Microfluidics: Fluid physics at the nanoliter scale
Squires, T. M., & Quake, S. R. (2005) · Reviews of Modern Physics · doi:10.1103/revmodphys.77.977 · Cited by 4,379
Lab-on-a-chip: microfluidics in drug discovery
Dittrich, P. S., & Manz, A. (2006) · Nature Reviews Drug Discovery · doi:10.1038/nrd1985 · Cited by 1,844
Nguyen, N.-T., & Wu, Z. (2005) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/15/2/r01 · Cited by 1,652
Microfluidic lab-on-a-chip platforms: requirements, characteristics and applications
Mark, D., Haeberle, S., Roth, G., von Stetten, F., & Zengerle, R. (2010) · Chemical Society Reviews · doi:10.1039/b820557b · Cited by 1,647
Point of Care Diagnostics: Status and Future
Gubala, V., Harris, L. F., Ricco, A. J., Tan, M. X., & Williams, D. E. (2012) · Analytical Chemistry · doi:10.1021/ac2030199 · Cited by 1,194
Microfluidic platforms for lab-on-a-chip applications
Haeberle, S., & Zengerle, R. (2007) · Lab on a Chip · doi:10.1039/b706364b · Cited by 1,124
Microscale acoustofluidics: Microfluidics driven via acoustics and ultrasonics
Friend, J., & Yeo, L. Y. (2011) · Reviews of Modern Physics · doi:10.1103/revmodphys.83.647 · Cited by 964
Bazant, M. Z., Kilic, M. S., Storey, B. D., & Ajdari, A. (2009) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2009.10.001 · Cited by 916
Oh, K. W., & Ahn, C. H. (2006) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/16/5/r01 · Cited by 838
Design of pressure-driven microfluidic networks using electric circuit analogy
Oh, K. W., Lee, K., Ahn, B., & Furlani, E. P. (2012) · Lab Chip · doi:10.1039/c2lc20799k · Cited by 685
Fu, Y. Q., Luo, J. K., Nguyen, N. T., Walton, A. J., Flewitt, A. J., Zu, X. T., Li, Y., McHale, G., Matthews, A., Iborra, E., et al. (2017) · Progress in Materials Science · doi:10.1016/j.pmatsci.2017.04.006 · Cited by 646
Microfluidics for cell separation
Bhagat, A. A. S., Bow, H., Hou, H. W., Tan, S. J., Han, J., & Lim, C. T. (2010) · Medical & Biological Engineering & Computing · doi:10.1007/s11517-010-0611-4 · Cited by 632
MEMS-based micropumps in drug delivery and biomedical applications
Nisar, A., Afzulpurkar, N., Mahaisavariya, B., & Tuantranont, A. (2008) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2007.10.064 · Cited by 614
Microfluidic Chips for Point‐of‐Care Immunodiagnostics
Gervais, L., de Rooij, N., & Delamarche, E. (2011) · Advanced Materials · doi:10.1002/adma.201100464 · Cited by 491
Disposable Microfluidic Devices: Fabrication, Function, and Application
Fiorini, G. S., & Chiu, D. T. (2005) · BioTechniques · doi:10.2144/05383rv02 · Cited by 487
Liquid metal enabled microfluidics
Khoshmanesh, K., Tang, S.-Y., Zhu, J. Y., Schaefer, S., Mitchell, A., Kalantar-zadeh, K., & Dickey, M. D. (2017) · Lab on a Chip · doi:10.1039/c7lc00046d · Cited by 458
Stretchable pumps for soft machines
Cacucciolo, V., Shintake, J., Kuwajima, Y., Maeda, S., Floreano, D., & Shea, H. (2019) · Nature · doi:10.1038/s41586-019-1479-6 · Cited by 447
Microfluidic cell culture systems for drug research
Wu, M.-H., Huang, S.-B., & Lee, G.-B. (2010) · Lab on a Chip · doi:10.1039/b921695b · Cited by 432
Ultrafast microfluidics using surface acoustic waves
Yeo, L. Y., & Friend, J. R. (2009) · Biomicrofluidics · doi:10.1063/1.3056040 · Cited by 391
A practical guide for the fabrication of microfluidic devices using glass and silicon
Iliescu, C., Taylor, H., Avram, M., Miao, J., & Franssila, S. (2012) · Biomicrofluidics · doi:10.1063/1.3689939 · Cited by 385
Waldbaur, A., Rapp, H., Länge, K., & Rapp, B. E. (2011) · Analytical Methods · doi:10.1039/c1ay05253e · Cited by 381
Nikonenko, V. V., Pismenskaya, N. D., Belova, E. I., Sistat, P., Huguet, P., Pourcelly, G., & Larchet, C. (2010) · Advances in Colloid and Interface Science · doi:10.1016/j.cis.2010.08.001 · Cited by 380
Micropumps, microvalves, and micromixers within PCR microfluidic chips: Advances and trends
Zhang, C., Xing, D., & Li, Y. (2007) · Biotechnology Advances · doi:10.1016/j.biotechadv.2007.05.003 · Cited by 376
Intelligent, self-powered, drug delivery systems
Patra, D., Sengupta, S., Duan, W., Zhang, H., Pavlick, R., & Sen, A. (2013) · Nanoscale · doi:10.1039/c2nr32600k · Cited by 375
Review on Micro- and Nanolithography Techniques and their Applications
Pimpin, A., & Srituravanich, W. (2012) · Engineering Journal · doi:10.4186/ej.2012.16.1.37 · Cited by 363
Piezopotential‐Driven Redox Reactions at the Surface of Piezoelectric Materials
Starr, M. B., Shi, J., & Wang, X. (2012) · Angewandte Chemie International Edition · doi:10.1002/anie.201201424 · Cited by 352
Electroosmotic pumps and their applications in microfluidic systems
Wang, X., Cheng, C., Wang, S., & Liu, S. (2009) · Microfluidics and Nanofluidics · doi:10.1007/s10404-008-0399-9 · Cited by 343
Current micropump technologies and their biomedical applications
Amirouche, F., Zhou, Y., & Johnson, T. (2009) · Microsystem Technologies · doi:10.1007/s00542-009-0804-7 · Cited by 332
Particle concentration and mixing in microdrops driven by focused surface acoustic waves
Shilton, R., Tan, M. K., Yeo, L. Y., & Friend, J. R. (2008) · Journal of Applied Physics · doi:10.1063/1.2951467 · Cited by 311
An integrated AC electrokinetic pump in a microfluidic loop for fast and tunable flow control
Studer, V., Pépin, A., Chen, Y., & Ajdari, A. (2004) · The Analyst · doi:10.1039/b408382m · Cited by 290
Induced-charge electrokinetic phenomena
Bazant, M. Z., & Squires, T. M. (2010) · Current Opinion in Colloid & Interface Science · doi:10.1016/j.cocis.2010.01.003 · Cited by 283
Pneumatic and hydraulic microactuators: a review
De Volder, M., & Reynaerts, D. (2010) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/20/4/043001 · Cited by 278
López-Herrera, J. M., Popinet, S., & Herrada, M. A. (2011) · Journal of Computational Physics · doi:10.1016/j.jcp.2010.11.042 · Cited by 265
Micro Electromechanical Systems (MEMS) Based Microfluidic Devices for Biomedical Applications
Ashraf, M. W., Tayyaba, S., & Afzulpurkar, N. (2011) · International Journal of Molecular Sciences · doi:10.3390/ijms12063648 · Cited by 263
Optically driven micropump produced by three-dimensional two-photon microfabrication
Maruo, S., & Inoue, H. (2006) · Applied Physics Letters · doi:10.1063/1.2358820 · Cited by 235
Flexible Microfluidics: Fundamentals, Recent Developments, and Applications
Fallahi, H., Zhang, J., Phan, H.-P., & Nguyen, N.-T. (2019) · Micromachines · doi:10.3390/mi10120830 · Cited by 224
“Non-mechanical micropumps do not have moving parts and are based on electrohydrodynamic, magnetohydrodynamic, electroosmotic, electrowetting and electromechanical concepts [5].”
BackgroundMicrofluidics and Raman microscopy: current applications and future challenges
Chrimes, A. F., Khoshmanesh, K., Stoddart, P. R., Mitchell, A., & Kalantar-zadeh, K. (2013) · Chemical Society Reviews · doi:10.1039/c3cs35515b · Cited by 217
Microfluidic Lab-on-a-Chip Platforms: Requirements, Characteristics and Applications
Mark, D., Haeberle, S., Roth, G., Von Stetten, F., & Zengerle, R. (2010) · NATO Science for Peace and Security Series A: Chemistry and Biology · doi:10.1007/978-90-481-9029-4_17 · Cited by 214
Oscillating bubbles: a versatile tool for lab on a chip applications
Hashmi, A., Yu, G., Reilly-Collette, M., Heiman, G., & Xu, J. (2012) · Lab on a Chip · doi:10.1039/c2lc40424a · Cited by 211
Enhanced Transport into and out of Dead-End Pores
Kar, A., Chiang, T.-Y., Ortiz Rivera, I., Sen, A., & Velegol, D. (2015) · ACS Nano · doi:10.1021/nn506216b · Cited by 206
Recent trends in mechanical micropumps and their applications: A review
Mohith, S., Karanth, P. N., & Kulkarni, S. M. (2019) · Mechatronics · doi:10.1016/j.mechatronics.2019.04.009 · Cited by 188
Towards practical sample preparation in point-of-care testing: user-friendly microfluidic devices
Park, J., Han, D. H., & Park, J.-K. (2020) · Lab on a Chip · doi:10.1039/d0lc00047g · Cited by 172
Chained Iron Microparticles for Directionally Controlled Actuation of Soft Robots
Schmauch, M. M., Mishra, S. R., Evans, E. E., Velev, O. D., & Tracy, J. B. (2017) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.7b01209 · Cited by 167
Fan, S.-K., Huang, P.-W., Wang, T.-T., & Peng, Y.-H. (2008) · Lab on a Chip · doi:10.1039/b803204a · Cited by 167
Xu, L., Lee, H., Jetta, D., & Oh, K. W. (2015) · Lab on a Chip · doi:10.1039/c5lc00716j · Cited by 164
Polymer-Based Microfluidic Devices for Pharmacy, Biology and Tissue Engineering
Alrifaiy, A., Lindahl, O. A., & Ramser, K. (2012) · Polymers · doi:10.3390/polym4031349 · Cited by 161
“This common method uses either embedded micro-pumps within the microfluidic chip [34], or external pump systems to generate external pressure flow, such as positive displacement pumping [35], or ultra-precise syringe pump systems [36].”
MethodMicrofluidic devices for in vitro studies on liver drug metabolism and toxicity
van Midwoud, P. M., Verpoorte, E., & Groothuis, G. M. M. (2011) · Integrative Biology · doi:10.1039/c0ib00119h · Cited by 115
Dumont-Fillon, D., Tahriou, H., Conan, C., & Chappel, E. (2014) · Micromachines · doi:10.3390/mi5041161 · Cited by 40
Metadata
- Authors
- Laser, D. J., & Santiago, J. G.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2004-04-21
- Volume
- 14
- Issue
- 6
- Pages
- R35-R64
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2051230121
- Cited by
- 1,848
- References
- 70
- FWCI
- 64.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.