Real-time measurement of the three-axis contact force distribution using a flexible capacitive polymer tactile sensor
Open accessThe DOI matches its Crossref record; 12 of the 12 references it cites were found in a registry or an index.
Abstract
In this paper, we report real-time measurement results of various contact forces exerted on a new flexible capacitive three-axis tactile sensor array based on polydimethylsiloxane (PDMS). A unit sensor consists of two thick PDMS layers with embedded copper electrodes, a spacer layer, an insulation layer and a bump layer. There are four capacitors in a unit sensor to decompose a contact force into its normal and shear components. They are separated by a wall-type spacer to improve the mechanical response time. Four capacitors are arranged in a square form. The whole sensor is an 8 _ 8 array of unit sensors and each unit sensor responds to forces in all three axes. Measurement results show that the full-scale range of detectable force is around 0–20 mN (250 kPa) for all three axes. The estimated sensitivities of a unit sensor with the current setup are 1.3, 1.2 and 1.2%/mN for the x- , y- and z -axes, respectively. A simple mechanical model has been established to calculate each axial force component from the measured capacitance value. Normal and shear force distribution images are captured from the fabricated sensor using a real-time measurement system. The mechanical response time of a unit sensor has been estimated to be less than 160 ms. The flexibility of the sensor has also been demonstrated by operating the sensor on a curved surface of 4 mm radius of curvature.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
State-of-the-Art in Force and Tactile Sensing for Minimally Invasive Surgery
Puangmali, P., Althoefer, K., Seneviratne, L. D., Murphy, D., & Dasgupta, P. (2008) · IEEE Sensors Journal · doi:10.1109/jsen.2008.917481 · Cited by 588 · cited 1×
“Many research groups are developing tactile sensors targeting MIS applications using various technologies [5].”
A Flexible Polymer Tactile Sensor: Fabrication and Modular Expandability for Large Area Deployment
Lee, H.-K., Chang, S.-I., & Yoon, E. (2006) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2006.886021 · Cited by 396
Self-citationLee, H.-K., Chung, J., Chang, S.-I., & Yoon, E. (2008) · Journal of Microelectromechanical Systems · doi:10.1109/jmems.2008.921727 · Cited by 350 · cited 5×
“A force gauge with 1 mN resolution and a motorized precision translation stage of about a 100 nm resolution have been used for unit sensor characterization as in the previous work [16].”
InfluentialSelf-citationDevelopment of polyimide flexible tactile sensor skin
Engel, J., Chen, J., & Liu, C. (2003) · Journal of Micromechanics and Microengineering · doi:10.1088/0960-1317/13/3/302 · Cited by 291
A traction stress sensor array for use in high-resolution robotic tactile imaging
Kane, B. J., Cutkosky, M. R., & Kovacs, G. T. A. (2000) · Journal of Microelectromechanical Systems · doi:10.1109/84.896763 · Cited by 235
Silicon three-axial tactile sensor
Chu, Z., Sarro, P. M., & Middelhoek, S. (1996) · Sensors and Actuators A Physical · doi:10.1016/s0924-4247(95)01190-0 · Cited by 150
A Novel Thick-Film Piezoelectric Slip Sensor for a Prosthetic Hand
Cotton, D. P. J., Chappell, P. H., Cranny, A., White, N. M., & Beeby, S. P. (2007) · IEEE Sensors Journal · doi:10.1109/jsen.2007.894912 · Cited by 135 · cited 1×
“Some of the works focused on the slip detection of an object using PVDF and relatively simple structure [9, 10].”
Beccai, L., Roccella, S., Ascari, L., Valdastri, P., Sieber, A., Carrozza, M. C., & Dario, P. (2008) · IEEE/ASME Transactions on Mechatronics · doi:10.1109/tmech.2008.918483 · Cited by 120 · cited 3×
“Therefore, the requirements for the tactile sensor for such applications are flexibility, compliance, robustness, around 1 mm spatial resolution for finger, and potential for large area deployment [6, 7].”
Thick-film force and slip sensors for a prosthetic hand
Cranny, A., Cotton, D. P. J., Chappell, P. H., Beeby, S., & White, N. M. (2005) · Sensors and Actuators A Physical · doi:10.1016/j.sna.2005.02.015 · Cited by 53 · cited 1×
“(Some figures in this article are in colour only in the electronic version)”
The revolution will be prosthetized
Adee, S. (2009) · IEEE Spectrum · doi:10.1109/mspec.2009.4734314 · Cited by 41
3-Axes Flexible Tactile Sensor Fabricated by Si Micromachining and Packaging Technology
Kim, K. S., Lee, K. R., Kim, Y. K., Lee, D. S., Cho, N. K., Kim, W. H., Park, K., Park, H. D., Park, Y. K., Kim, J. H., et al. (2006) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2006.1627890 · Cited by 40 · cited 1×
“In order to make the array sensor flexible, a few three-axis tactile sensors have been implemented on a flexible polymer substrate such as polyimide [13–15].”
A Polymer-Based Flexible Tactile Sensor for Normal and Shear Load Detection
Hwang, E.-S., Seo, J.-H., & Kim, Y.-J. (2006) · IEEE International Conference on Micro Electro Mechanical Systems (MEMS) · doi:10.1109/memsys.2006.1627899 · Cited by 37
Cited by
Hammock, M. L., Chortos, A., Tee, B. C. ‐., Tok, J. B. ‐., & Bao, Z. (2013) · Advanced Materials · doi:10.1002/adma.201302240 · Cited by 2,396
Recent Progress in Electronic Skin
Wang, X., Dong, L., Zhang, H., Yu, R., Pan, C., & Wang, Z. L. (2015) · Advanced Science · doi:10.1002/advs.201500169 · Cited by 976
Park, J., Lee, Y., Hong, J., Lee, Y., Ha, M., Jung, Y., Lim, H., Kim, S. Y., & Ko, H. (2014) · ACS Nano · doi:10.1021/nn505953t · Cited by 649
The TacTip Family: Soft Optical Tactile Sensors with 3D-Printed Biomimetic Morphologies
Ward-Cherrier, B., Pestell, N., Cramphorn, L., Winstone, B., Giannaccini, M. E., Rossiter, J., & Lepora, N. F. (2018) · Soft Robotics · doi:10.1089/soro.2017.0052 · Cited by 587
Skin-inspired electronic devices
Chortos, A., & Bao, Z. (2014) · Materials Today · doi:10.1016/j.mattod.2014.05.006 · Cited by 571
Metadata
- Authors
- Lee, H.-K., Chung, J., Chang, S.-I., & Yoon, E.
- Venue
- Journal of Micromechanics and Microengineering
- Publisher
- IOP Publishing
- Published
- 2011-02-08
- Volume
- 21
- Issue
- 3
- Pages
- 035010
- ISSN
- 0960-1317 (ISSN-L)
- 1361-6439
- OpenAlex
- W2122169310
- Cited by
- 187
- References
- 12
- FWCI
- 5.47
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.