CoChat

Similarity in bilateral photoplethysmographic peripheral pulse wave characteristics at the ears, thumbs and toes

Allen, John, Murray, Alan · 2000 · Physiological Measurement
Cited by 92

The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.

Abstract

The characteristics of the photoplethysmography (PPG) pulse signal are body site specific, with pulses from the various peripheral sites showing differences in pulse transit time, strength and shape, and variation of each over time. The aim of this study was to determine the similarity in the right-left pulse characteristics for a group of normal subjects with pulses obtained simultaneously from six peripheral sites (cars, thumbs and big toes). A multi-site photoplethysmography pulse measurement and analysis system is described and comprised six sets of pulse probes and amplifiers, arranged and electronically matched in pairs for the right and left side comparisons. Two sets of data were collected: firstly a set of validation data to test the electronic matching of right left channels, and secondly a set of physiological data for pulses from 40 normal subjects. The right-to-left side similarity in pulse waveform shape at the three segmental levels (ears, thumbs and toes) was assessed using two types of analysis: root mean square error (RMSE) providing a measure of differences, and cross correlation analysis providing a measure of the degree of similarity. Very low levels of RMSE and correlation coefficients close to unity were obtained for the system validation data, demonstrating good right-left channel matching. The RMSE was an order of magnitude lower than that calculated for the normative physiological data, where median RMSE levels were between 0.053 and 0.060 relative to a peak-to-peak pulse amplitude of unity. The median correlation coefficients were greater than 0.98 for all three segmental levels studied, with the maximum values approaching those of the validation data. We have shown that pulses from the right and left sides of normal subjects are highly correlated at each segmental level. We have obtained a normative range of pulse data, with which specific (vascular) patient groups can be compared.

Overview

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1088/0967-3334/21/3/303

Cites

3 of 3 references verified0 citation errors · 0 not checkable

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cites

Show all 3 references

Cited by

Metadata

Authors
Allen, J., & Murray, A.
Venue
Physiological Measurement
Published
2000-08-01
Volume
21
Issue
3
Pages
369-377
ISSN
  • 0967-3334 (ISSN-L)
  • 1361-6579
OpenAlex
W2039457474
Cited by
92
References
3
FWCI
2.02
Type
journal article
Language
en
Open access
closed

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.