Similarity in bilateral photoplethysmographic peripheral pulse wave characteristics at the ears, thumbs and toes
The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Abstract
The characteristics of the photoplethysmography (PPG) pulse signal are body site specific, with pulses from the various peripheral sites showing differences in pulse transit time, strength and shape, and variation of each over time. The aim of this study was to determine the similarity in the right-left pulse characteristics for a group of normal subjects with pulses obtained simultaneously from six peripheral sites (cars, thumbs and big toes). A multi-site photoplethysmography pulse measurement and analysis system is described and comprised six sets of pulse probes and amplifiers, arranged and electronically matched in pairs for the right and left side comparisons. Two sets of data were collected: firstly a set of validation data to test the electronic matching of right left channels, and secondly a set of physiological data for pulses from 40 normal subjects. The right-to-left side similarity in pulse waveform shape at the three segmental levels (ears, thumbs and toes) was assessed using two types of analysis: root mean square error (RMSE) providing a measure of differences, and cross correlation analysis providing a measure of the degree of similarity. Very low levels of RMSE and correlation coefficients close to unity were obtained for the system validation data, demonstrating good right-left channel matching. The RMSE was an order of magnitude lower than that calculated for the normative physiological data, where median RMSE levels were between 0.053 and 0.060 relative to a peak-to-peak pulse amplitude of unity. The median correlation coefficients were greater than 0.98 for all three segmental levels studied, with the maximum values approaching those of the validation data. We have shown that pulses from the right and left sides of normal subjects are highly correlated at each segmental level. We have obtained a normative range of pulse data, with which specific (vascular) patient groups can be compared.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Skin photoplethysmography — a review
Kamal, A. A. R., Harness, J. B., Irving, G., & Mearns, A. J. (1989) · Computer Methods and Programs in Biomedicine · doi:10.1016/0169-2607(89)90159-4 · Cited by 328 · cited 1×
“The PPG signal is complex and has several components which can be classified as either low frequency (LF) or high frequency (HF) (Kamal et al 1989).”
BackgroundNitzan, M., Babchenko, A., Khanokh, B., & Landau, D. (1998) · Physiological Measurement · doi:10.1088/0967-3334/19/1/008 · Cited by 217 · cited 2×
“The low frequency components include information relating to blood pressure control, venous return to the heart, respiration and thermoregulation (Nitzan et al 1998, 1999, Johansson and Öberg 1999a, b); the higher frequency (HF) components include the pulse itself which contains information about…”
BackgroundBasal perfusion of the cutaneous microcirculation: Measurements as a function of anatomic position
Tur, E., Tur, M., Maibach, H. I., & Guy, R. H. (1983) · Journal of Investigative Dermatology · doi:10.1111/1523-1747.ep12522619 · Cited by 163 · cited 1×
“The characteristics of the PPG pulse signal are also body site specific (Tur et al 1983), with pulses from the various peripheral sites showing differences in pulse transit time, strength and shape, and variation of each over time.”
Background
Cited by
Photoplethysmography and its application in clinical physiological measurement
Allen, J. (2007) · Physiological Measurement · doi:10.1088/0967-3334/28/3/r01 · Cited by 3,967
“These characteristics are also body site dependent (Allen and Murray 2000b).”
BackgroundInfluentialSelf-citationGhamari, M. (2018) · International Journal of Biosensors & Bioelectronics · doi:10.15406/ijbsbe.2018.04.00125 · Cited by 945
Photoplethysmography Revisited: From Contact to Noncontact, From Point to Imaging
Sun, Y., & Thakor, N. (2016) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2015.2476337 · Cited by 556
Photoplethysmogram Analysis and Applications: An Integrative Review
Park, J., Seok, H. S., Kim, S.-S., & Shin, H. (2022) · Frontiers in Physiology · doi:10.3389/fphys.2021.808451 · Cited by 422
Contact-Free Measurement of Cardiac Pulse Based on the Analysis of Thermal Imagery
Garbey, M., Sun, N., Merla, A., & Pavlidis, I. (2007) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2007.891930 · Cited by 402
Advances in Photopletysmography Signal Analysis for Biomedical Applications
Moraes, J. L., Rocha, M. X., Vasconcelos, G. G., Vasconcelos Filho, J. E., De Albuquerque, V. H. C., & Alexandria, A. R. (2018) · Sensors · doi:10.3390/s18061894 · Cited by 292
Adaptive threshold method for the peak detection of photoplethysmographic waveform
Shin, H. S., Lee, C., & Lee, M. (2009) · Computers in Biology and Medicine · doi:10.1016/j.compbiomed.2009.10.006 · Cited by 210
Allen, J., & Murray, A. (2003) · Physiological Measurement · doi:10.1088/0967-3334/24/2/306 · Cited by 202
Self-citationAge-related changes in peripheral pulse timing characteristics at the ears, fingers and toes
Allen, J., & Murray, A. (2002) · Journal of Human Hypertension · doi:10.1038/sj.jhh.1001478 · Cited by 179
Self-citationRelation between heart rate and pulse transit time during paced respiration
Drinnan, M. J., Allen, J., & Murray, A. (2001) · Physiological Measurement · doi:10.1088/0967-3334/22/3/301 · Cited by 167
Self-citationPhotoplethysmography signal processing and synthesis
Mejía-Mejía, E., Allen, J., Budidha, K., El-Hajj, C., Kyriacou, P. A., & Charlton, P. H. (2022) · Photoplethysmography · doi:10.1016/b978-0-12-823374-0.00015-3 · Cited by 138
“Healthy subjects tend to exhibit high bilateral CC values [34], whereas there are greater differences between bilateral PATs in peripheral arterial disease [145], and greater levels of variability over time [146].”
BackgroundMethodSelf-citationMW-PPG Sensor: An on-Chip Spectrometer Approach
Chang, C.-C., Wu, C.-T., Choi, B. I., & Fang, T.-J. (2019) · Sensors · doi:10.3390/s19173698 · Cited by 30
Sex-Related Differences in Photoplethysmography Signals Measured From Finger and Toe
Dehghanojamahalleh, S., & Kaya, M. (2019) · IEEE Journal of Translational Engineering in Health and Medicine · doi:10.1109/jtehm.2019.2938506 · Cited by 25
“Even though the previous studies evaluated the effect of parameters such as age, systolic blood pressure, height, and HR on features (primarily PTT) extracted from ear, finger and toe PPGs [4]–[6], [22], [23], they did not analyze additional important physiological parameters such as weight, sex, BMI, or morphological…”
Method
Metadata
- Authors
- Allen, J., & Murray, A.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2000-08-01
- Volume
- 21
- Issue
- 3
- Pages
- 369-377
- ISSN
- 0967-3334 (ISSN-L)
- 1361-6579
- OpenAlex
- W2039457474
- Cited by
- 92
- References
- 3
- FWCI
- 2.02
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.