Time variation of ammonia, acetone, isoprene and ethanol in breath: a quantitative SIFT-MS study over 30 days
Open accessThe DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
A study of the concentrations of the common breath metabolites ammonia, acetone, isoprene, ethanol and acetaldehyde in the breath of five subjects over a period of 30 days has been carried out. Breath samples were taken and analysed in the early morning on arrival at the laboratory. The real time analyses of three consecutive breath exhalations were carried out using selected ion flow tube mass spectrometry (SIFT-MS) on line to the instrument. Sufficient data were obtained to allow meaningful concentration distributions to be obtained for ammonia, acetone, isoprene and ethanol. These showed that the ammonia, acetone and isoprene concentrations exhibited sensibly normal distributions, with coefficients of variation of typically 0.3. Obvious and statistically significant (p < 0.01) differences are apparent in the mean concentrations of these metabolites between the five individuals. The acetaldehyde concentrations were relatively low and close to the instrument detection limit, and the differences between the mean concentrations of the five subjects were not statistically significant (p = 0.4), so distributions were not obtained. The mean concentrations, in parts per billion (ppb), of each metabolite range amongst the five subjects are as follows: ammonia, 422-2389: acetone, 293-870; isoprene, 55-121; ethanol, 27-153; acetaldehyde, 2-5. There are no obvious patterns in the distributions of these particular metabolites for these individuals, except that the ammonia levels were greatest in the breath of the two oldest subjects.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Quantitative analysis of ammonia on the breath of patients in end-stage renal failure
Davies, S., Spanel, P., & Smith, D. (1997) · Kidney International · doi:10.1038/ki.1997.324 · Cited by 406
Self-citationThe diagnostic potential of breath analysis.
Manolis, A. (1983) · Clinical Chemistry · doi:10.1093/clinchem/29.1.5 · Cited by 399
Selected ion flow tube: a technique for quantitative trace gas analysis of air and breath
Španěl, P., & Smith, D. (1996) · Medical & Biological Engineering & Computing · doi:10.1007/bf02523843 · Cited by 229
Self-citationŠpaněl, P., Smith, D., Holland, T. A., Singary, W. A., & Elder, J. B. (1999) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19990730)13:14<1354::aid-rcm641>3.0.co;2-j · Cited by 189
Self-citationSmith, D., Spanel, P., & Davies, S. (1999) · Journal of Applied Physiology · doi:10.1152/jappl.1999.87.5.1584 · Cited by 180
Self-citationThe Novel Selected-ion Flow Tube Approach to Trace Gas Analysis of Air and Breath
Smith, D. C., & Španěl, P. (1996) · Rapid Communications in Mass Spectrometry · doi:10.1002/(sici)1097-0231(19960731)10:10<1183::aid-rcm641>3.0.co;2-3 · Cited by 177
Self-citationTrace Composition of Human Respiratory Gas
Conkle, J. P., Camp, B. J., & Welch, B. E. (1975) · Archives of Environmental Health An International Journal · doi:10.1080/00039896.1975.10666702 · Cited by 173
Isoprene synthesis by plants and animals
Sharkey, T. D. (1996) · Endeavour · doi:10.1016/0160-9327(96)10014-4 · Cited by 148
Smith, D. C., & Španěl, P. (1996) · International Reviews in Physical Chemistry · doi:10.1080/01442359609353183 · Cited by 135
Self-citationKohlmüller, D., & Kochen, W. (1993) · Analytical Biochemistry · doi:10.1006/abio.1993.1195 · Cited by 112
Cited by
Selected ion flow tube mass spectrometry (SIFT‐MS) for on‐line trace gas analysis
Smith, D., & Španěl, P. (2005) · Mass Spectrometry Reviews · doi:10.1002/mas.20033 · Cited by 801
Self-citationRighettoni, M., Tricoli, A., & Pratsinis, S. E. (2010) · Analytical Chemistry · doi:10.1021/ac902695n · Cited by 630
Wang, C., & Sahay, P. (2009) · Sensors · doi:10.3390/s91008230 · Cited by 596
Microbial Volatile Organic Compounds
Korpi, A., Järnberg, J., & Pasanen, A.-L. (2009) · Critical Reviews in Toxicology · doi:10.1080/10408440802291497 · Cited by 596
Review—Non-Invasive Monitoring of Human Health by Exhaled Breath Analysis: A Comprehensive Review
Das, S., & Pal, M. (2020) · Journal of The Electrochemical Society · doi:10.1149/1945-7111/ab67a6 · Cited by 466
Advances in Electronic-Nose Technologies Developed for Biomedical Applications
Wilson, A. D., & Baietto, M. (2011) · Sensors · doi:10.3390/s110101105 · Cited by 400
Shin, J., Choi, S., Lee, I., Youn, D., Park, C. O., Lee, J., Tuller, H. L., & Kim, I. (2013) · Advanced Functional Materials · doi:10.1002/adfm.201202729 · Cited by 391
Turner, C., Španěl, P., & Smith, D. (2006) · Physiological Measurement · doi:10.1088/0967-3334/27/4/001 · Cited by 379
Self-citationSolid-state gas sensors for breath analysis: A review
Di Natale, C., Paolesse, R., Martinelli, E., & Capuano, R. (2014) · Analytica Chimica Acta · doi:10.1016/j.aca.2014.03.014 · Cited by 365
Ferroelectric WO3 Nanoparticles for Acetone Selective Detection
Wang, L., Teleki, A., Pratsinis, S. E., & Gouma, P. I. (2008) · Chemistry of Materials · doi:10.1021/cm800761e · Cited by 357
Progress in SIFT‐MS: Breath analysis and other applications
Španěl, P., & Smith, D. (2011) · Mass Spectrometry Reviews · doi:10.1002/mas.20303 · Cited by 336
Self-citationBreath acetone monitoring by portable Si:WO3 gas sensors
Righettoni, M., Tricoli, A., Gass, S., Schmid, A., Amann, A., & Pratsinis, S. E. (2012) · Analytica Chimica Acta · doi:10.1016/j.aca.2012.06.002 · Cited by 317
Breath Analysis in Disease Diagnosis: Methodological Considerations and Applications
Lourenço, C., & Turner, C. (2014) · Metabolites · doi:10.3390/metabo4020465 · Cited by 314
Is breath acetone a biomarker of diabetes? A historical review on breath acetone measurements
Wang, Z., & Wang, C. (2013) · Journal of Breath Research · doi:10.1088/1752-7155/7/3/037109 · Cited by 309
Isoprene and acetone concentration profiles during exercise on an ergometer
King, J., Kupferthaler, A., Unterkofler, K., Koc, H., Teschl, S., Teschl, G., Miekisch, W., Schubert, J., Hinterhuber, H., & Amann, A. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/2/027006 · Cited by 278
On-Line Analysis of Exhaled Breath: Focus Review
Bruderer, T., Gaisl, T., Gaugg, M. T., Nowak, N., Streckenbach, B., Müller, S., Moeller, A., Kohler, M., & Zenobi, R. (2019) · Chemical Reviews · doi:10.1021/acs.chemrev.9b00005 · Cited by 278
Güntner, A. T., Koren, V., Chikkadi, K., Righettoni, M., & Pratsinis, S. E. (2016) · ACS Sensors · doi:10.1021/acssensors.6b00008 · Cited by 257
Wilson, A. (2015) · Metabolites · doi:10.3390/metabo5010140 · Cited by 242
“In addition to these major normal gases, other common endogenous VOCs include ammonia, acetone, ethanol, methanol, propanol, acetaldehyde and isoprene [15–20].”
BackgroundWang, C., Mbi, A., & Shepherd, M. (2010) · IEEE Sensors Journal · doi:10.1109/jsen.2009.2035730 · Cited by 236
Hunt, K. E., Moore, M. J., Rolland, R. M., Kellar, N. M., Hall, A. J., Kershaw, J., Raverty, S. A., Davis, C. E., Yeates, L. C., Fauquier, D. A., et al. (2013) · Conservation Physiology · doi:10.1093/conphys/cot006 · Cited by 231
“…(Baumbach, 2009), differential mobility spectrometry (Krebs et al., 2005; Molina et al., 2008), selected ion flow tube mass spectrometry (Diskin et al., 2003; Smith and Spanel, 2011a, b; Spanel and Smith, 2011), colorimetric sensors that indicate the presence of fingerprints of breath…”
BackgroundFilipiak, W., Ruzsanyi, V, Mochalski, P., Filipiak, A., Bajtarevic, A., Ager, C., Denz, H., Hilbe, W., Jamnig, H., Hackl, M., et al. (2012) · Journal of Breath Research · doi:10.1088/1752-7155/6/3/036008 · Cited by 218
ZnO–CuO Core-Hollow Cube Nanostructures for Highly Sensitive Acetone Gas Sensors at the ppb Level
Lee, J. E., Lim, C. K., Park, H. J., Song, H., Choi, S.-Y., & Lee, D.-S. (2020) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.0c08593 · Cited by 205
Current Status of Methods and Techniques for Breath Analysis
Cao, W., & Duan, Y. (2007) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408340600976499 · Cited by 191
“Inside the flow tube, precursor ions, usually H3O+, NO+, or O+• 2 (95), react with VOCs present in the sample.”
BackgroundXiao, T., Wang, X.-Y., Zhao, Z.-H., Li, L., Zhang, L., Yao, H.-C., Wang, J.-S., & Li, Z.-J. (2014) · Sensors and Actuators B: Chemical · doi:10.1016/j.snb.2014.04.015 · Cited by 181
Analysis of breath, exhaled via the mouth and nose, and the air in the oral cavity
Wang, T., Pysanenko, A., Dryahina, K., Španěl, P., & Smith, D. (2008) · Journal of Breath Research · doi:10.1088/1752-7155/2/3/037013 · Cited by 164
Self-citationDas, S., Pal, S., & Mitra, M. (2016) · Journal of Medical and Biological Engineering · doi:10.1007/s40846-016-0164-6 · Cited by 164
“10 Ethanol [2, 15, 16, 211–213, 215] 27 [217] to 216.”
Smith, D., Wang, T., Sulé‐Suso, J., Španěl, P., & Haj, A. E. (2003) · Rapid Communications in Mass Spectrometry · doi:10.1002/rcm.984 · Cited by 158
Self-citationDetermining concentration patterns of volatile compounds in exhaled breath by PTR-MS
Schwarz, K., Filipiak, W., & Amann, A. (2009) · Journal of Breath Research · doi:10.1088/1752-7155/3/2/027002 · Cited by 158
“Acetone 500 Diskin et al [49] Ethanol 100 Diskin et al [49] Isoprene 100 Diskin et al [49]; Kushch et al [50] ∼137 ppb; Kushch et al [34] ∼104 ppb Acetaldehyde 25 Turner et al [51] Acetonitrile 50 Abbott et al [52] ∼70 ppb; Kushch et al [17] ∼33 ppb Benzene 3 Jordan et al [53] ∼8 ppb; Kushch et al [17] ∼2 ppb Methanol…”
Human body-odor components and their determination
Pandey, S. K., & Kim, K.-H. (2011) · TrAC Trends in Analytical Chemistry · doi:10.1016/j.trac.2010.12.005 · Cited by 121
Metadata
- Authors
- Diskin, A. M., pan l, P., & Smith, D.
- Venue
- Physiological Measurement
- Publisher
- IOP Publishing
- Published
- 2003-01-13
- Volume
- 24
- Issue
- 1
- Pages
- 107-119
- ISSN
- 0967-3334 (ISSN-L)
- OpenAlex
- W1965904339
- Cited by
- 237
- References
- 29
- FWCI
- 8.20
- Type
- journal article
- Language
- en
- Open access
- bronze
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.